Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Cardiol Young ; : 1-7, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622972

RESUMO

BACKGROUND: The study of psychological well-being and related resilient outcomes is of increasing focus in cardiovascular research. Despite the critical importance of psychological well-being and related resilient outcomes in promoting optimal cardiac health, there have been very few psychological interventions directed towards children with heart disease. This paper describes the development and theoretical framework of the WE BEAT Wellbeing Education Program, a group-based psychoeducation and coping skills training intervention designed to improve psychological well-being and resilience in adolescents with paediatric heart disease. METHODS: Program development was informed by patient and family needs and input gathered via large, international survey methods as well as qualitative investigation, a theoretical framework, and related resilience intervention research. RESULTS: An overview of the WE BEAT intervention components and structure of the programme is provided. CONCLUSIONS: The WE BEAT Wellbeing Education Program was developed as one of the first resiliency-focused interventions in paediatric heart disease with an overall objective to foster positive psychological well-being and resilient outcomes through a health promotion and prevention lens in an accessible format while providing access to safe, peer-to-peer community building. Feasibility pilot results are forthcoming. Future directions include mobile app-based delivery and larger-scale efficacy and implementation trials.

2.
Pediatr Cardiol ; 2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37725124

RESUMO

Augmented reality (AR) visualization of 3D rotational angiography (3DRA) provides 3D representations of cardiac structures with full visualization of the procedural environment. The purpose of this study was to evaluate the feasibility of converting 3DRAs of congenital heart disease patients to AR models, highlight the workflow for 3DRA optimization for AR visualization, and assess physicians' perceptions of their use. This single-center study prospectively evaluated 30 retrospectively-acquired 3DRAs that were converted to AR, compared to Computer Models (CM). Median patient age 6.5 years (0.24-38.8) and weight 20.6 kg (3.4-107.0). AR and CM quality were graded highly. RV pacing was associated with higher quality of both model types (p = 0.02). Visualization and identification of structures were graded as "very easy" in 81.1% (n = 73) and 67.8% (n = 61) of AR and CM, respectively. Fifty-nine (66%) grades 'Agreed' or 'Strongly Agreed' that AR models provided superior appreciation of 3D relationships; AR was found to be least beneficial in visualization of aortic arch obstruction. AR models were thought to be helpful in identifying pathology and assisting in interventional planning in 85 assessments (94.4%). There was significant potential seen in the opportunity for patient/family counseling and trainee/staff education with AR models. It is feasible to convert 3D models of 3DRAs into AR models, which are of similar image quality as compared to CM. AR models provided additional benefits to visualization of 3D relationships in most anatomies. Future directions include integration of interventional simulation, peri-procedural counseling of patients and families, and education of trainees and staff with AR models.

3.
Artigo em Inglês | MEDLINE | ID: mdl-34116781

RESUMO

Tracheobronchomalacia is a condition of dynamic collapse of the trachea and mainstem bronchi. The clinical significance of tracheobronchomalacia depends on its severity. Mild cases may be medically managed with limited symptomology, while severe cases require advanced therapies, lengthy hospital stays, and carry significant morbidity and mortality. Current therapies for severe tracheobronchomalacia include tracheostomy with prolonged mechanical ventilation, aortopexy, tracheobronchopexy, and intraluminal metallic, silicone, or bioresorbable stents. Three-dimensional (3D)-printed, patient-specific, bioresorbable airway splinting is a novel treatment option that is undergoing investigation in a cohort of critically ill children with severe tracheobronchomalacia. At the time of our last review of our data, 29 splints had been implanted in 15 children with intrathoracic tracheobronchomalacia. The median follow-up was 8.5 months. There were 12 long-term survivors, and all but one lived at home. This article discusses the details of our institution's development and use of 3D-printed, patient-specific, bioresorbable splints for treatment of severe tracheobronchomalacia in the pediatric population.


Assuntos
Contenções , Traqueobroncomalácia , Implantes Absorvíveis , Criança , Humanos , Impressão Tridimensional , Traqueia , Traqueobroncomalácia/terapia
4.
J Am Coll Cardiol ; 81(12): 1181-1188, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36948735

RESUMO

BACKGROUND: Studies have shown that diverse care teams optimize patient outcomes. Describing the current representation of women and minorities has been a critical step in improving diversity across several fields. OBJECTIVES: To address the lack of data specific to pediatric cardiology, the authors conducted a national survey. METHODS: U.S. academic pediatric cardiology programs with fellowship training programs were surveyed. Division directors were invited (July 2021 to September 2021) to complete an e-survey of program composition. Underrepresented minorities in medicine (URMM) were characterized using standard definitions. Descriptive analyses at the hospital, faculty, and fellow level were performed. RESULTS: Altogether, 52 of 61 programs (85%) completed the survey, representing 1,570 total faculty and 438 fellows, with a wide range in program size (7-109 faculty, 1-32 fellows). Although women comprise approximately 60% of faculty in pediatrics overall, they made up 55% of fellows and 45% of faculty in pediatric cardiology. Representation of women in leadership roles was notably less, including 39% of clinical subspecialty directors, 25% of endowed chairs, and 16% of division directors. URMM comprise approximately 35% of the U.S. population; however, they made up only 14% of pediatric cardiology fellows and 10% of faculty, with very few in leadership roles. CONCLUSIONS: These national data suggest a "leaky pipeline" for women in pediatric cardiology and very limited presence of URRM overall. Our findings can inform efforts to elucidate underlying mechanisms for persistent disparity and reduce barriers to improving diversity in the field.


Assuntos
Cardiologia , Educação de Pós-Graduação em Medicina , Humanos , Feminino , Criança , Estados Unidos , Docentes de Medicina , Bolsas de Estudo , Grupos Minoritários
5.
J Biomech Eng ; 133(4): 041003, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21428677

RESUMO

The purpose of this study is to validate numerical simulations of flow and pressure in an abdominal aortic aneurysm (AAA) using phase-contrast magnetic resonance imaging (PCMRI) and an in vitro phantom under physiological flow and pressure conditions. We constructed a two-outlet physical flow phantom based on patient imaging data of an AAA and developed a physical Windkessel model to use as outlet boundary conditions. We then acquired PCMRI data in the phantom while it operated under conditions mimicking a resting and a light exercise physiological state. Next, we performed in silico numerical simulations and compared experimentally measured velocities, flows, and pressures in the in vitro phantom to those computed in the in silico simulations. There was a high degree of agreement in all of the pressure and flow waveform shapes and magnitudes between the experimental measurements and simulated results. The average pressures and flow split difference between experiment and simulation were all within 2%. Velocity patterns showed good agreement between experimental measurements and simulated results, especially in the case of whole-cycle averaged comparisons. We demonstrated methods to perform in vitro phantom experiments with physiological flows and pressures, showing good agreement between numerically simulated and experimentally measured velocity fields and pressure waveforms in a complex patient-specific AAA geometry.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Análise de Elementos Finitos , Hemodinâmica , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/patologia , Pressão Sanguínea , Humanos , Imageamento por Ressonância Magnética , Modelos Anatômicos
6.
Laryngoscope ; 129(8): 1763-1771, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30794335

RESUMO

OBJECTIVES/HYPOTHESIS: To report the clinical safety and efficacy of three-dimensional (3D)-printed, patient-specific, bioresorbable airway splints in a cohort of critically ill children with severe tracheobronchomalacia. STUDY DESIGN: Case series. METHODS: From 2012 to 2018, 15 subjects received 29 splints on their trachea, right and/or left mainstem bronchi. The median age at implantation was 8 months (range, 3-25 months). Nine children were female. Five subjects had a history of extracorporeal membrane oxygenation (ECMO), and 11 required continuous sedation, six of whom required paralytics to maintain adequate ventilation. Thirteen were chronically hospitalized, unable to be discharged, and seven were hospitalized their entire lives. At the time of splint implantation, one subject required ECMO, one required positive airway pressure, and 13 subjects were tracheostomy and ventilator dependent, requiring a median positive end-expiratory pressure (PEEP) of 14 cm H2 O (range, 6-20 cm H2 0). Outcomes collected included level of respiratory support, disposition, and splint-related complications. RESULTS: At the time of discharge from our institution, at a median of 28 days postimplantation (range, 10-56 days), the subject on ECMO was weaned from extracorporeal support, and the subjects who were ventilated via tracheostomy had a median change in PEEP (discharge-baseline) of -2.5 cm H2 O (range, -15 to 2 cm H2 O, P = .022). At median follow-up of 8.5 months (range, 0.3-77 months), all but one of the 12 surviving subjects lives at home. Of the 11 survivors who were tracheostomy dependent preoperatively, one is decannulated, one uses a speaking valve, six use a ventilator exclusively at night, and three remain ventilator dependent. CONCLUSIONS: This case series demonstrates the initial clinical efficacy of the 3D-printed bioresorbable airway splint device in a cohort of critically ill children with severe tracheobronchomalacia. LEVEL OF EVIDENCE: 4 Laryngoscope, 129:1763-1771, 2019.


Assuntos
Implantes Absorvíveis , Manuseio das Vias Aéreas/instrumentação , Impressão Tridimensional , Contenções , Traqueobroncomalácia/cirurgia , Pré-Escolar , Estudos de Coortes , Oxigenação por Membrana Extracorpórea , Feminino , Humanos , Lactente , Masculino , Respiração com Pressão Positiva , Traqueia/cirurgia , Resultado do Tratamento
8.
Neurology ; 85(8): 692-700, 2015 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-26208959

RESUMO

OBJECTIVE: To evaluate the effects of bapineuzumab on brain ß-amyloid (Aß) burden using (11)C-Pittsburgh compound B ((11)C-PiB)-PET. METHODS: Two phase 3 clinical trials, 1 each in apolipoprotein APOE ε4 carriers and noncarriers, were conducted in patients with mild to moderate Alzheimer disease dementia. Bapineuzumab, an anti-Aß monoclonal antibody, or placebo, was administered by IV infusion every 13 weeks for 78 weeks. PET substudies assessed change in brain fibrillar Aß over 71 weeks using an (11)C-PiB-PET standardized uptake value ratio (SUVr) global cortical average (GCA) comprising the average SUVr from 5 cortical regions of interest with cerebellar gray matter as the reference region. RESULTS: A total of 115 carriers and 39 noncarriers were analyzed. The difference (δ) in mean baseline to 71 week change in (11)C-PiB-PET GCA between bapineuzumab and placebo was significant in carriers (0.5 mg/kg vs placebo δ = -0.101; p = 0.004) and in pooled analyses of both carriers and noncarriers (0.5 mg/kg vs placebo δ = -0.068; p = 0.027; 1.0 mg/kg vs placebo δ = -0.133; p = 0.028) but not in the noncarrier trial separately. Analyses by individual region of interest and in mild disease yielded findings similar to the main trial results. CONCLUSIONS: The (11)C-PiB-PET imaging results demonstrated reduction of fibrillar Aß accumulation in patients with Alzheimer disease treated with bapineuzumab; however, as no clinical benefit was observed, the findings are consistent with the hypotheses that bapineuzumab may not have been initiated early enough in the disease course, the doses were insufficient, or the most critical Aß species were inadequately targeted.


Assuntos
Doença de Alzheimer/tratamento farmacológico , Peptídeos beta-Amiloides/metabolismo , Anticorpos Monoclonais Humanizados/farmacologia , Benzotiazóis , Córtex Cerebral , Tomografia por Emissão de Pósitrons/métodos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/genética , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/efeitos dos fármacos , Compostos de Anilina , Anticorpos Monoclonais Humanizados/administração & dosagem , Apolipoproteína E4/genética , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/efeitos dos fármacos , Córtex Cerebral/metabolismo , Feminino , Heterozigoto , Humanos , Masculino , Pessoa de Meia-Idade , Tiazóis , Resultado do Tratamento
9.
Int J Numer Method Biomed Eng ; 30(2): 280-95, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24493404

RESUMO

Computational fluid dynamics modeling was used to investigate changes in blood transport topology between rest and exercise conditions in five patient-specific abdominal aortic aneurysm models. MRI was used to provide the vascular anatomy and necessary boundary conditions for simulating blood velocity and pressure fields inside each model. Finite-time Lyapunov exponent fields and associated Lagrangian coherent structures were computed from blood velocity data and were used to compare features of the transport topology between rest and exercise both mechanistically and qualitatively. A mix-norm and mix-variance measure based on fresh blood distribution throughout the aneurysm over time were implemented to quantitatively compare mixing between rest and exercise. Exercise conditions resulted in higher and more uniform mixing and reduced the overall residence time in all aneurysms. Separated regions of recirculating flow were commonly observed in rest, and these regions were either reduced or removed by attached and unidirectional flow during exercise, or replaced with regional chaotic and transiently turbulent mixing, or persisted and even extended during exercise. The main factor that dictated the change in flow topology from rest to exercise was the behavior of the jet of blood penetrating into the aneurysm during systole.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Exercício Físico/fisiologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea/fisiologia , Simulação por Computador , Estudos Transversais , Hemodinâmica , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Descanso/fisiologia
10.
Ann Biomed Eng ; 39(7): 1947-60, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21404126

RESUMO

The purpose of this article is to validate numerical simulations of flow and pressure incorporating deformable walls using in vitro flow phantoms under physiological flow and pressure conditions. We constructed two deformable flow phantoms mimicking a normal and a restricted thoracic aorta, and used a Windkessel model at the outlet boundary. We acquired flow and pressure data in the phantom while it operated under physiological conditions. Next, in silico numerical simulations were performed, and velocities, flows, and pressures in the in silico simulations were compared to those measured in the in vitro phantoms. The experimental measurements and simulated results of pressure and flow waveform shapes and magnitudes compared favorably at all of the different measurement locations in the two deformable phantoms. The average difference between measured and simulated flow and pressure was approximately 3.5 cc/s (13% of mean) and 1.5 mmHg (1.8% of mean), respectively. Velocity patterns also showed good qualitative agreement between experiment and simulation especially in regions with less complex flow patterns. We demonstrated the capabilities of numerical simulations incorporating deformable walls to capture both the vessel wall motion and wave propagation by accurately predicting the changes in the flow and pressure waveforms at various locations down the length of the deformable flow phantoms.


Assuntos
Artérias/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Análise de Elementos Finitos , Modelos Cardiovasculares , Animais , Simulação por Computador , Módulo de Elasticidade/fisiologia , Humanos , Resistência ao Cisalhamento/fisiologia
11.
Ann Biomed Eng ; 39(2): 864-83, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21103933

RESUMO

Hemodynamic conditions are hypothesized to affect the initiation, growth, and rupture of abdominal aortic aneurysms (AAAs), a vascular disease characterized by progressive wall degradation and enlargement of the abdominal aorta. This study aims to use magnetic resonance imaging (MRI) and computational fluid dynamics (CFD) to quantify flow stagnation and recirculation in eight AAAs by computing particle residence time (PRT). Specifically, we used gadolinium-enhanced MR angiography to obtain images of the vessel lumens, which were used to generate subject-specific models. We also used phase-contrast MRI to measure blood flow at supraceliac and infrarenal locations to prescribe physiologic boundary conditions. CFD was used to simulate pulsatile flow, and PRT, particle residence index, and particle half-life of PRT in the aneurysms were computed. We observed significant regional differences of PRT in the aneurysms with localized patterns that differed depending on aneurysm geometry and infrarenal flow. A bulbous aneurysm with the lowest mean infrarenal flow demonstrated the slowest particle clearance. In addition, improvements in particle clearance were observed with increase of mean infrarenal flow. We postulate that augmentation of mean infrarenal flow during exercise may reduce chronic flow stasis that may influence mural thrombus burden, degradation of the vessel wall, and aneurysm growth.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Modelos Cardiovasculares , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho da Partícula
12.
Ann Biomed Eng ; 39(8): 2186-202, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21509633

RESUMO

Abdominal aortic aneurysm (AAA) is a vascular disease resulting in a permanent, localized enlargement of the abdominal aorta. We previously hypothesized that the progression of AAA may be slowed by altering the hemodynamics in the abdominal aorta through exercise [Dalman, R. L., M. M. Tedesco, J. Myers, and C. A. Taylor. Ann. N.Y. Acad. Sci. 1085:92-109, 2006]. To quantify the effect of exercise intensity on hemodynamic conditions in 10 AAA subjects at rest and during mild and moderate intensities of lower-limb exercise (defined as 33 ± 10% and 63 ± 18% increase above resting heart rate, respectively), we used magnetic resonance imaging and computational fluid dynamics techniques. Subject-specific models were constructed from magnetic resonance angiography data and physiologic boundary conditions were derived from measurements made during dynamic exercise. We measured the abdominal aortic blood flow at rest and during exercise, and quantified mean wall shear stress (MWSS), oscillatory shear index (OSI), and particle residence time (PRT). We observed that an increase in the level of activity correlated with an increase of MWSS and a decrease of OSI at three locations in the abdominal aorta, and these changes were most significant below the renal arteries. As the level of activity increased, PRT in the aneurysm was significantly decreased: 50% of particles were cleared out of AAAs within 1.36 ± 0.43, 0.34 ± 0.10, and 0.22 ± 0.06 s at rest, mild exercise, and moderate exercise levels, respectively. Most of the reduction of PRT occurred from rest to the mild exercise level, suggesting that mild exercise may be sufficient to reduce flow stasis in AAAs.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Simulação por Computador , Hemodinâmica , Angiografia por Ressonância Magnética , Modelos Cardiovasculares , Esforço Físico , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
13.
Cardiovasc Eng Technol ; 1(1)2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24324530

RESUMO

PURPOSE: Hemodynamic forces are thought to play a critical role in abdominal aortic aneurysm (AAA) growth. In silico and in vitro simulations can be used to study these forces, but require accurate aortic geometries and boundary conditions. Many AAA simulations use patient-specific geometries, but utilize inlet boundary conditions taken from a single, unrelated, healthy young adult. METHODS: In this study, we imaged 43 AAA patients using a 1.5 T MR scanner. A 24-frame cardiac-gated one-component phase-contrast magnetic resonance imaging sequence was used to measure volumetric flow at the supraceliac (SC) and infrarenal (IR) aorta, where flow information is typically needed for simulation. For the first 36 patients, individual waveforms were interpolated to a 12-mode Fourier curve, peak-aligned, and averaged. Allometric scaling equations were derived from log-log plots of mean SC and IR flow vs. body mass, height, body surface area (BSA), and fat-free body mass. The data from the last seven patients were used to validate our model. RESULTS: Both the SC and IR averaged waveforms had the biphasic shapes characteristic of older adults, and mean SC and IR flows over the cardiac cycle were 51.2 ± 10.3 and 17.5 ± 5.44 mL/s, respectively. Linear regression of the log-log plots revealed that BSA was most strongly predictive of mean SC (R2 = 0.29) and IR flow (R2 = 0.19), with the highest combined R2. When averaged, the measured and predicted waveforms for the last seven patients agreed well. CONCLUSIONS: We present a method to estimate SC and IR mean flows and waveforms for AAA simulation.

14.
Ann Biomed Eng ; 38(4): 1288-313, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20143263

RESUMO

Abdominal aortic aneurysms (AAAs) affect 5-7% of older Americans. We hypothesize that exercise may slow AAA growth by decreasing inflammatory burden, peripheral resistance, and adverse hemodynamic conditions such as low, oscillatory shear stress. In this study, we use magnetic resonance imaging and computational fluid dynamics to describe hemodynamics in eight AAAs during rest and exercise using patient-specific geometric models, flow waveforms, and pressures as well as appropriately resolved finite-element meshes. We report mean wall shear stress (MWSS) and oscillatory shear index (OSI) at four aortic locations (supraceliac, infrarenal, mid-aneurysm, and suprabifurcation) and turbulent kinetic energy over the entire computational domain on meshes containing more than an order of magnitude more elements than previously reported results (mean: 9.0-million elements; SD: 2.3 M; range: 5.7-12.0 M). MWSS was lowest in the aneurysm during rest 2.5 dyn/cm(2) (SD: 2.1; range: 0.9-6.5), and MWSS increased and OSI decreased at all four locations during exercise. Mild turbulence existed at rest, while moderate aneurysmal turbulence was present during exercise. During both rest and exercise, aortic turbulence was virtually zero superior to the AAA for seven out of eight patients. We postulate that the increased MWSS, decreased OSI, and moderate turbulence present during exercise may attenuate AAA growth.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/reabilitação , Terapia por Exercício/métodos , Angiografia por Ressonância Magnética/métodos , Modelos Cardiovasculares , Esforço Físico , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Descanso
15.
Am J Physiol Heart Circ Physiol ; 291(4): H1700-8, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16714362

RESUMO

Allometric scaling laws relate structure or function between species of vastly different sizes. They have rarely been derived for hemodynamic parameters known to affect the cardiovascular system, e.g., wall shear stress (WSS). This work describes noninvasive methods to quantify and determine a scaling law for WSS. Geometry and blood flow velocities in the infrarenal aorta of mice and rats under isoflurane anesthesia were quantified using two-dimensional magnetic resonance angiography and phase-contrast magnetic resonance imaging at 4.7 tesla. Three-dimensional models constructed from anatomic data were discretized and used for computational fluid dynamic simulations using phase-contrast velocity imaging data as inlet boundary conditions. WSS was calculated along the infrarenal aorta and compared between species to formulate an allometric equation for WSS. Mean WSS along the infrarenal aorta was significantly greater in mice and rats compared with humans (87.6, 70.5, and 4.8 dyn/cm(2), P < 0.01), and a scaling exponent of -0.38 (R(2) = 0.92) was determined. Manipulation of the murine genome has made small animal models standard surrogates for better understanding the healthy and diseased human cardiovascular system. It has therefore become increasingly important to understand how results scale from mouse to human. This noninvasive methodology provides the opportunity to serially quantify changes in WSS during disease progression and/or therapeutic intervention.


Assuntos
Aorta/fisiologia , Fenômenos Fisiológicos Cardiovasculares , Imagem Cinética por Ressonância Magnética/métodos , Modelos Teóricos , Animais , Aorta/patologia , Aorta/fisiopatologia , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo/fisiologia , Índice de Massa Corporal , Tamanho Corporal , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Humanos , Angiografia por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Ratos , Ratos Sprague-Dawley , Especificidade da Espécie
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA