Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 55(4): 421-5, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11948884

RESUMO

AngioSeal (AS) and VasoSeal (VS) are collagen-based arterial closure devices utilized to achieve earlier hemostasis and ambulation in diagnostic and interventional percutaneous procedures. To our knowledge, there has been no randomized studies comparing these two devices as approved for use in the United States. One hundred fifty-seven patients were randomized to receive either the 8 Fr AS (n = 79) or VS (n = 78) closure device. Data on 95 patients who had coronary angiography (49 AS, 46 VS) and 55 patients who underwent angioplasty (28 AS, 27 VS) were completed. Heparin was not administered during the coronary angiogram procedure. The activated clotting time was kept at approximately 300 sec during angioplasty. Patients on coumadin or GP IIb/IIIa platelet inhibitors were not included in this study. The time unit interval to achieve hemostasis in this study was based on the time the AS tension spring was left over the common femoral artery following collagen deployment as per the manufacturer's instructions (20 min). Time to hemostasis, time to ambulation, and major and minor complications were prospectively recorded. Two-tailed t-test and chi-square analysis were performed on continuous and dichotomous variables, respectively. For the angiogram-only subgroup, time (min) to hemostasis (20.51 +/- 4.36 vs. 18.59 +/- 11.77; P = 0.30) and ambulation (145.71 +/- 124 vs. 109.89 +/- 60.37; P = 0.075) were not statistically different for the AS and VS, respectively. Similarly, for the angioplasty subgroup, time (min) to hemostasis (24.23 +/- 12.70 vs. 19.57 +/- 2.27; P = 0.077) and ambulation (607.32 +/- 344.22 vs. 486.48 +/- 200.37; P = 0.12) were not statistically different for both AS and VS, respectively. Furthermore, there were no statistical differences in deployment failure, major, minor, or total complication rates between the two devices. In the absence of GP IIb/IIIa inhibitors, VS and the 8 Fr AS devices have statistically similar time to hemostasis and ambulation as well as device failures and complication rates following coronary angiography and angioplasty.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Colágeno/efeitos adversos , Colágeno/uso terapêutico , Angiografia Coronária/efeitos adversos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/terapia , Hemostasia Cirúrgica/efeitos adversos , Suturas/efeitos adversos , Idoso , Deambulação Precoce , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA