Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Radiol ; 51(7): 1253-1258, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33544192

RESUMO

BACKGROUND: Ultrasonography may reliably visualize both appropriately positioned and malpositioned femoral-approach catheter tips. Radiography may be used to confirm catheter tip position after placement, but its utility following intraprocedural ultrasound (US) catheter tip verification is unclear. OBJECTIVES: To report the utility of confirmatory radiographs after US-guided tunneled femoral central venous catheter (CVC) placements by interventional radiology in pediatric patients. MATERIALS AND METHODS: A total of 484 pediatric patients underwent bedside US-guided tunneled femoral CVC placements in an intensive care setting at a single tertiary children's hospital between Jan. 1, 2016, and April 20, 2020. Technical success, adverse events, post-procedure radiographic practices and inter-modality catheter tip concordance were recorded. All radiographs were performed within 12 h of catheter placement. RESULTS: The mean patient age was 175±508 days (range: 1 day to 19 years), including 257 (53.1%) males and 227 (46.9%) females. Of the 484 attempted placements, 472 (97.5%) were primary placements. Four hundred eighty-one (99.4%) placements were technically successful. There were three (0.6%) technical failures due to previously undiagnosed iliofemoral venous occlusive disease. Five (1.0%) adverse events occurred. Radiographs were obtained within 12 h of CVC placement in 171 (35.3%) patients, in 120 (70.2%) of whom the indication was recent catheter placement. All 171 (100%) post-placement radiographs showed catheter tip location concordance with the intra-procedural US. In one (0.2%) patient, in whom there was nonvisualization of a guidewire and clinical concern for malposition during US-guided placement, post-procedure radiographs, coupled with multiplanar venography, demonstrated inadvertent paravertebral venous plexus catheter placement. CONCLUSION: The concordance between intra-procedural US and confirmatory post-procedure radiographs of CVC placements by interventional radiology obviates the need for routine radiographs. Radiographs may be obtained in instances of proceduralist uncertainty or clinical concern.


Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Cateterismo Venoso Central/efeitos adversos , Criança , Feminino , Humanos , Lactente , Masculino , Radiografia , Radiologia Intervencionista , Ultrassonografia , Ultrassonografia de Intervenção
2.
Curr Probl Diagn Radiol ; 49(1): 42-47, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30655113

RESUMO

PURPOSE: To quantify cost drivers for thoracic duct embolization based on time-driven activity-based costing methods. MATERIALS AND METHODS: This was an Institutional Review Board-approved (HUM00141114) and Health Insurance Portability and Accountability Act-compliant study performed at a quaternary care institution over a 14-month period. After process maps for thoracic duct embolization were prepared, staff practical capacity rates and consumable equipment costs were analyzed via a time-driven activity-based costing methodology. Sensitivity analyses were performed to identify primary cost drivers. RESULTS: Mean procedure duration was 4.29 hours (range: 2.15-7.16 hours). Base case cost, per case, for thoracic duct embolization was $7466.67. Multivariate sensitivity analyses performed with all minimum and maximum values for cost input variables yielded a cost range of $1001.95 (minimum) to $89,503.50 (maximum). Using local salary information and negotiated prices for materials as cost parameters, the true cost per case of thoracic duct embolization at the study institution was $8038.94. Univariate analysis demonstrated that the primary driver of staffing costs was the length of time the attending anesthesiologist was present. The predominant modifiable cost drivers included cyanoacrylate glue volume used (minimum $4467; maximum $12,467), cost of glue utilized (minimum $5217; maximum $10,467), and cost of coils utilized (minimum $7377; maximum $10,917). Univariate analysis predicted that the use of Histoacryl glue in place of TRUFILL cyanoacrylate glue resulted in a cost savings of $2947.50 per case. CONCLUSIONS: The base cost per case for thoracic duct embolization was $7466.67. Costs, namely anesthesia staffing costs, cyanoacrylate glue, and coils were large, potentially modifiable drivers of overall cost for thoracic duct embolization.


Assuntos
Embolização Terapêutica/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Doenças Torácicas/economia , Doenças Torácicas/terapia , Humanos , Ducto Torácico , Fatores de Tempo
3.
CVIR Endovasc ; 3(1): 75, 2020 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-33025347

RESUMO

BACKGROUND: Isolated persistent left superior vena cava (PLSVC) is a rare vascular anatomic variant, which can be an incidental finding at the time of an endovascular procedure. CASE PRESENTATION: This report describes the technical success, adverse events, and clinical outcomes of transjugular intrahepatic portosystemic shunt (TIPS) creation via isolated PLSVC. Three adult patients with cirrhosis and isolated PLSVC underwent TIPS placement successfully with one major adverse event. Two patients required TIPS revision within 90 days. There were no deaths within 90 days. CONCLUSIONS: TIPS creation via isolated PLSVC is feasible using standard techniques with a left jugular vein approach. Caution is warranted during the procedure to assess for any aberrant drainage pattern to the left atrium and to prepare for potentially challenging instrument navigation through the coronary sinus.

4.
Radiol Case Rep ; 13(3): 596-598, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30073042

RESUMO

Hematochezia may be a result of anatomic, vascular, inflammatory, infectious, or neoplastic diseases. Colonoscopic evaluation and therapy may be limited because of intermittent bleeding in the setting of numerous diverticula. This report describes a patient with diverticulosis who presented with hematochezia and hemodynamic instability with failed colonoscopic and arteriographic evaluations, and was treated with percutaneous transcolonic diverticular cyanoacrylate and epinephrine injection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA