Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 31(5): 967-974, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27778208

RESUMO

The Near-infrared spectroscopy (NIRS) has not been adopted as a mainstream monitoring modality in acute neurosurgical care due to concerns about its reliability and consistency. However, improvements in NIRS parameter recovery techniques are now available that may improve the quantitative accuracy of NIRS for this clinical context. Therefore, the aim of this study was to compare the abilities of a continuous-wave (CW) NIRS device with a similarly clinically viable NIRS device utilising a frequency-domain (FD) parameter recovery technique in detecting changes in cerebral tissue saturation during stepwise increases of experimentally induced hypoxia. Nine healthy individuals (6M/3F) underwent a dynamic end-tidal forced manipulation of their expiratory gases to induce a stepwise induced hypoxia. The minimum end-tidal oxygen partial pressure (EtO2) achieved was 40 mm Hg. Simultaneous neurological and extra-cranial tissue NIRS reading were obtained during this protocol by both tested devices. Both devices detected significant changes in cerebral tissue saturation during the induction of hypoxia (CW 9.8 ± 2.3 %; FD 7.0 ± 3.4 %; Wilcoxon signed rank test P < 0.01 for both devices). No significant difference was observed between the saturation changes observed by either device (P = 0.625). An observably greater degree of noise was noticed in parameters recovered by the FD device, and both demonstrated equally variable baseline readings (Coefficient of variance 8.4 and 9.7 % for the CW and FD devices, respectively) between individuals tested. No advantageous difference was observed in parameters recovered from the FD device compared with those detected by CW.


Assuntos
Encéfalo/diagnóstico por imagem , Hipóxia , Consumo de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Computadores , Feminino , Voluntários Saudáveis , Humanos , Masculino , Oxigênio , Pressão Parcial , Estudos Prospectivos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
2.
J Biomed Opt ; 24(6): 1-12, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31222990

RESUMO

A clinical need exists for low-cost and noninvasive imaging tools capable of detecting inflammation in the joints of inflammatory arthritis patients. Previous studies have reported an optical contrast between inflamed and noninflamed joints resulting from distinct absorption and scattering properties. Accurate classification using nonocclusion-based continuous wave, transillumination imaging was limited to patient-specific changes during follow-up examination as opposed to single time-point examination, which was attributed to high intersubject variability. In distinction from previous work, optical images were acquired from the dorsal side with illumination on the palmar side and features about the spatial distribution of transmitted light along the joint were assessed using a normalized Fourier transform method. Results using this approach demonstrated an area under receiver operator curve of up to 0.888 for detecting inflammation in a pilot study involving single time-point examination of 144 joints from 21 rheumatology patients. This workflow may enable future development of clinically viable, low-cost devices for assessing inflammation in arthritis patients, without the need for cuff occlusion or comparison to baseline.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Análise de Fourier , Imagem Óptica/métodos , Adulto , Idoso , Área Sob a Curva , Feminino , Humanos , Inflamação/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Projetos Piloto
3.
Biomed Opt Express ; 9(4): 1423-1444, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29675293

RESUMO

Spectrally constrained diffuse optical tomography (SCDOT) is known to improve reconstruction in diffuse optical imaging; constraining the reconstruction by coupling the optical properties across multiple wavelengths suppresses artefacts in the resulting reconstructed images. In other work, L1-norm regularization has been shown to improve certain types of image reconstruction problems as its sparsity-promoting properties render it robust against noise and enable the preservation of edges in images, but because the L1-norm is non-differentiable, it is not always simple to implement. In this work, we show how to incorporate L1 regularization into SCDOT. Three popular algorithms for L1 regularization are assessed for application in SCDOT: iteratively reweighted least square algorithm (IRLS), alternating directional method of multipliers (ADMM), and fast iterative shrinkage-thresholding algorithm (FISTA). We introduce an objective procedure for determining the regularization parameter in these algorithms and compare their performance in simulated experiments, and in real data acquired from a tissue phantom. Our results show that L1 regularization consistently outperforms Tikhonov regularization in this application, particularly in the presence of noise.

4.
Biomed Opt Express ; 9(4): 1445-1460, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29675294

RESUMO

Rheumatoid arthritis (RA) is an inflammatory joint disease often affecting the hands, which if untreated causes disability. Diffuse optical tomography (DOT) provides information about the underlying functional properties of biological tissue. To detect pathophysiological changes in inflamed RA joints, a good understanding of the baseline values for healthy subjects is first required. Finger joints from healthy subjects were imaged using a non-contact, multispectral, continuous wave DOT system, recovering physiological parameters of oxygen saturation, total haemoglobin, water concentration and scatter amplitude. Reconstructed values across the cohort demonstrated good consistency between finger joints from the same participant, with greater variation seen between subjects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA