Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Int Orthop ; 48(3): 667-674, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37723316

RESUMO

PURPOSE: Unlike periprosthetic femoral fractures, periprosthetic acetabular fractures during total hip arthroplasty (THA) have not been evaluated in detail. We prospectively evaluated the incidence, patterns, risk factors, and clinical outcomes of intraoperative periprosthetic acetabular fractures using pre- and postoperative computer tomography (CT). METHODS: In this prospective single-centre study, we evaluated 234 consecutive patients (250 hips) who underwent THA and three-dimensional CT before and after the surgery. We assessed the incidence, pattern of fractures, outcomes for each fracture pattern, reoperation and revision rates, Harris hip score, and visual analog scale (VAS) for pain. Multivariate regression models were used to identify risk factors for periprosthetic acetabular fractures. RESULTS: In total, 43 periprosthetic acetabular fractures (17.2%) were identified via CT. Fractures occurred most frequently at the superolateral wall. Early cup migration occurred in three hips. None of the patients underwent revision surgery for acetabular loosening. Regression modeling showed that rheumatoid arthritis was a significant predictor of periprosthetic acetabular fractures. CONCLUSIONS: Periprosthetic acetabular fractures are not infrequent during cementless THA and are more common in patients with rheumatoid arthritis.


Assuntos
Artrite Reumatoide , Artroplastia de Quadril , Fraturas do Quadril , Prótese de Quadril , Fraturas Periprotéticas , Fraturas da Coluna Vertebral , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Incidência , Estudos Prospectivos , Prótese de Quadril/efeitos adversos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/lesões , Fraturas do Quadril/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Reoperação/efeitos adversos , Tomografia/efeitos adversos , Artrite Reumatoide/cirurgia , Estudos Retrospectivos
2.
Int J Environ Health Res ; : 1-12, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627937

RESUMO

This study aimed to investigate the airborne exposure to aerosols according to the particle size distribution of three different spray types (nano-nozzled spray gun, low-temperature steam spray, and fogger) and compare the concentrations of inhaled aerosols between children and adults. Airborne aerosols released from three products were observed using size-segregated particle measurements, and particle concentrations deposited in the respiratory tracts of adults and children were estimated using multi-path particle dosimetry lung deposition models. All types of sprayers generated the most nanoparticles (~100 nm). Due to their higher respiratory rate than adults, a larger number of particles <1.0 µm deposited in the children's respiratory tracts was higher. The sequences of the total number of particles in the respiratory regions after spraying nano-nozzled spray gun and fogger were alveolar (AL)>tracheobronchial (TB)>head airway (HA) in adults and AL>HA>TB in children. Meanwhile, the trend of low-temperature steam spray was AL>TB>HA in adults and AL>TB>HA in children.

3.
Eur J Orthop Surg Traumatol ; 33(6): 2347-2352, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36404340

RESUMO

PURPOSE: Total hip arthroplasty (THA) after vascularized fibular grafting (VFG) is technically demanding with poorer outcomes compared to primary THA in patients with osteonecrosis of the femoral head (ONFH). The purpose of this study was to compare the outcomes of THA after VFG after removal of the graft with that of primary THA. METHODS: ONFH patients treated by VFG at a single institution were studied retrospectively. THAs after VFG performed by single arthroplasty surgeon with a single type of THA prosthesis were enrolled in the study. A control cohort of patients was created by 1:1 matching with the THA after VFG cohort according to age, gender, and American Society of Anesthesiology (ASA) score from ONFH patients treated by primary THA. Early and long-term outcomes were compared between the two groups. RESULTS: A total of 24 hips were included in the THA after VFG group and compared with 24 primary THA hips. No significant difference was noted in stem position. The THA after VFG group had increased blood loss and longer duration of operation time. There were two cases of intraoperative femur fractures in the THA after VFG group. The femoral stem of both groups were stable, with no cases of revision, and similar HHS scores at the last follow-up. CONCLUSION: THA after VFG may have similar short to midterm outcomes with primary THA after removal of the residual abutting bone graft and correct positioning of the femoral stem.


Assuntos
Artroplastia de Quadril , Necrose da Cabeça do Fêmur , Humanos , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Necrose da Cabeça do Fêmur/cirurgia , Necrose da Cabeça do Fêmur/etiologia , Seguimentos
4.
Biomarkers ; 26(8): 691-702, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34530669

RESUMO

INTRODUCTION: Understanding interactions of smoking topography with biomarkers of exposure to tobacco is essential for accurate smoking risk assessments. METHODS: In this study, the smoking topography and the levels of tobacco smoke exposure urinary biomarkers of a sample of active Korean smokers were quantified and measured. The results were used to investigate the effect of daily activities and smoking time on the smoking topography. Moreover, correlations between the smoking topography parameters and biomarkers were assessed. RESULTS: No significant effect of either the daily activities or time on the smoking topography of the subjects were observed. Synchronic correlations of the cigarette consumption per day (CPD) and the average flow per puff with both urinary cotinine and trans-3'-hydroxycotinine were significant. For the urinary nicotine metabolites, the peak levels appeared when the CPD was over 19 cigarettes per day and the average puff velocity was between 35 and 45 ml/s. Nevertheless, when the average flow was over 60 ml/s, the levels of cotinine and trans-3'-hydroxycotinine significantly dropped. CONCLUSIONS: The findings of this study may be beneficial for further smoking risk assessments with contributions of both the smoking topography and biomarkers to provide current smokers with applicable cession programs.Clinical significanceSmoking habits and levels of urinary biomarkers of Korean smokers are investigated.People with a higher dependency on nicotine smoke cigarettes with slower puffs.Effects of daily activities or time on smoking topography were not significant.Correlations between smoking topography and urinary biomarkers were significant.Peak biomarker levels were observed under certain smoking topography conditions.


Assuntos
Biomarcadores/urina , Exposição por Inalação/análise , Fumaça/análise , Fumantes/estatística & dados numéricos , Fumar/urina , Adulto , Idoso , Povo Asiático/estatística & dados numéricos , Cromatografia Líquida de Alta Pressão/métodos , Cotinina/análogos & derivados , Cotinina/urina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nicotina/metabolismo , Nicotina/urina , República da Coreia , Fumar/etnologia , Espectrometria de Massas em Tandem/métodos , Adulto Jovem
5.
BMC Musculoskelet Disord ; 22(1): 892, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34670523

RESUMO

BACKGROUND: Acetabular prosthesis positioning in total hip arthroplasty (THA) is crucial in reducing the risk of dislocation. There has been minimal research on the proper way to put the acetabular components into the safe zone intraoperatively. Assessment of version by intraoperative imaging intensifier is very valuable. The value of Widmer's method, using the intraoperative C-arm available to determine cup anteversion was assessed. METHODS: One hundred one hips in 91 patients who underwent primary THA were eligible for inclusion. Utilizing intraoperative C-arm images, measurement was performed using the technique described by Widmer. The values obtained using 3D computed tomography postoperatively, which determined the anteversion of the acetabular component, were regarded as the reference standard. RESULTS: The method of Widmer obtained values similar to those obtained using 3D computed tomography and was considered accurate (n.s.). All 101 hips were positioned in the set target zone. Among the 101 hips, the cup position in nine hips (8.9%) was changed. The dislocation rate in our study was 1.0% with all dislocations occurring in hips placed in the target zone. The mean Harris hip score after THA in 1 year was 94.2 (82-98). CONCLUSIONS: The method of Widmer was accurate using intraoperative imaging intensifier for the measurement of the anteversion of the acetabular component during THA, with reference to the anteversion obtained from the 3D computed tomography. Also, utilizing intraoperative C-arm imaging was very useful because it allowed for correction of the position of the acetabular cup.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Humanos , Intensificação de Imagem Radiográfica
6.
J Arthroplasty ; 36(3): 1049-1054, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33036842

RESUMO

BACKGROUND: The number of young patients with hematological disease requiring total hip arthroplasty (THA) is expected to increase. We aimed to investigate the long-term THA outcomes in patients with osteonecrosis of the femoral head (ONFH) following allogeneic bone marrow transplantation (BMT) for hematological disease. METHODS: All patients who underwent THA for osteonecrosis after BMT from 1997 to 2012 were identified at 2 institutions. Using propensity scores, 75 THAs in 45 patients were matched for age, gender, body mass index, American Society of Anesthesiologists score, and year of surgery with 75 THAs in 58 patients with idiopathic ONFH without a history of hematological disease (1:1 ratio). The mean age at surgery was 36.7 years and 52% were men. Clinical and radiographic evaluations were performed and clinical scores were obtained at last follow-up. Kaplan-Meier analyses were used to compare survivorship. RESULTS: At a mean follow-up of 10.6 ± 3.5 years, clinical, radiographic, and survivorship outcomes, and the Harris hip scores were similar between both groups. The 13-year survivorship for all-cause revision was 93.4% for the BMT group and 95% for the control group (P = .928). No significant differences were observed between groups in the rates of reoperation (4% vs 5.3%, P = 1.000), 90-day readmission (all 5.3%), or overall mortality (4.4% vs 1.7%, P = .681). No hips had periprosthetic joint infection or septic loosening in either group. Osteolysis occurred in none of the BMT patients and in 2 hips (2.7%) of the control patients (P = .497). CONCLUSION: This large cohort multicenter survey at 11-year follow-up shows that contemporary cementless THA in young hematological disease patients after allogeneic BMT is not associated with a higher risk for surgical complications, revision, reoperation, readmission, and mortality compared to a matched cohort of idiopathic ONFH.


Assuntos
Artroplastia de Quadril , Doenças Hematológicas , Transplante de Células-Tronco Hematopoéticas , Prótese de Quadril , Osteonecrose , Artroplastia de Quadril/efeitos adversos , Transplante de Medula Óssea/efeitos adversos , Estudos de Coortes , Feminino , Seguimentos , Doenças Hematológicas/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Osteonecrose/epidemiologia , Osteonecrose/etiologia , Osteonecrose/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
7.
Biomarkers ; 25(8): 659-669, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32912026

RESUMO

OBJECTIVES: The aim of the study was to investigate the correlations within the levels of biomarkers in different biological matrices, along with smoking topography variables, among active male smokers in Korea. Accordingly, we defined a transformation factor to convert level of tobacco smoke exposure and impact biomarkers from different biometrics. METHODS: We examined smoking topography of recruited volunteers using a self-reporting survey. The level of tobacco smoke exposure and impact biomarkers in subjects' urine and blood were analysed. Results were used to assess the correlations between the topography survey items with biomarkers in biological matrices. The relationship between the biomarkers in urine and blood was analysed. Accordingly, we defined a transformation factor as the ratio of different biomarkers in urine and blood matrices. RESULTS: Significant correlations among smoking topography variables and biomarkers were found. Besides, a strong significant association was found among urine and blood cotinine (ρ = 0.817) and NMR (ρ = 0.905). Urine vs blood cotinine and NMR transformation factors were calculated to be 6.17 L-Blood/g-Creatinine and 10.2, respectively. CONCLUSIONS: The validated transformation factor connects epidemiological cohort studies with tobacco smoking exposure risk assessment. Hence, this study might be beneficial for further habit-based smoking risk assessments to obtain successful regional cession policies.


Assuntos
Cotinina/sangue , Cotinina/urina , Hábitos , Fumantes , Fumar/sangue , Fumar/urina , Adulto , Biomarcadores/sangue , Biomarcadores/urina , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Seul/epidemiologia , Fumar/efeitos adversos , Fumar/epidemiologia , Adulto Jovem
8.
Nano Lett ; 19(10): 7449-7456, 2019 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-31478378

RESUMO

The surface hydrophobicity of a microbial cell is known to be one of the important factors in its adhesion to an interface. To date, such property has been altered by either genetic modification or external pH, temperature, and nutrient control. Here we report a new strategy to engineer a microbial cell surface and discover the unique dynamic trapping of hydrophilic cells at an air/water interface via hydrophobicity switching. We demonstrate the surface transformation and hydrophobicity switching of Escherichia coli (E. coli) by metal nanoparticles. By employing real-time dark-field imaging, we directly observe that hydrophobic gold nanoparticle-coated E. coli, unlike its naked counterpart, is irreversibly trapped at the air/water interface because of elevated hydrophobicity. We show that our surface transformation method and resulting dynamic interfacial trapping can be generally extended to Gram-positive bateria, Gram-negative bacteria, and fungi. As the dynamic interfacial trapping allows the preconcentration of microbial cells, high intensity of scattering light, in-plane focusing, and near-field enhancement, we are able to directly quantify E. coli as low as 1.0 × 103 cells/ml by using a smartphone with an image analyzer. We also establish the identification of different microbial cells by the characteristic Raman transitions directly measured from the interfacially trapped cells.


Assuntos
Contagem de Células/métodos , Escherichia coli/isolamento & purificação , Ouro/química , Nanopartículas Metálicas/química , Saccharomyces cerevisiae/citologia , Infecções por Escherichia coli/microbiologia , Humanos , Interações Hidrofóbicas e Hidrofílicas , Imagem Óptica/métodos , Análise Espectral Raman/métodos , Propriedades de Superfície
9.
BMC Musculoskelet Disord ; 20(1): 263, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31142296

RESUMO

BACKGROUND: Using data from the Korean Hip Registry, we aimed to investigate mid-term clinical and radiographic outcomes, including the prevalence of periprosthetic joint infection (PJI), osteolysis, and component loosening or dislocation, and to analyze the incidence of bearing-related complications following modern ceramic-on-ceramic (COC) total hip arthroplasty (THA) using a single cementless hip system. METHODS: Four hundred eighty-two patients (602 hips) who underwent Forte or Delta COC THAs with a single hip system and had a minimum 5-year follow-up were identified. The sample included 243 (50.4%) women and 239 (49.6%) men with a mean age of 50.6 years (range: 18-83 years). The Forte group comprised 310 hips, and the Delta group comprised 292 hips. The mean follow-up was 6.1 years (range: 5-10.2 years). RESULTS: Cup orientation did not differ between groups. No hip had a PJI or osteolysis in either group. All acetabular components and all but two femoral components (in the Delta group) were well fixed. Dislocations occurred in six (1.9%) hips in the Forte group and one (0.3%) hip in the Delta group (p = 0.124). A total of nine (1.5%) revisions were performed. The 5-year survival rates for all-cause revisions were 98.4 and 98.6%, respectively. One (0.3%) ceramic head fracture occurred in the Forte group. Sixteen (5%) hips exhibited clicking and 6 (2%) hips had squeaking in the Forte group; 16 (6%) hips exhibited clicking and 5 (2%) hips had squeaking in the Delta group. Multiple regression analysis revealed that noise generation was unassociated with any factor. CONCLUSIONS: From the Korean Hip Registry data, THA with modern ceramic bearings showed encouraging results, with lower risks of PJI, osteolysis, and component loosening. In particular, Delta COC THA resulted in no PJI or ceramic fracture and had a reduced dislocation risk. However, associated noise remains a concern.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cerâmica/efeitos adversos , Prótese de Quadril/efeitos adversos , Ruído , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/epidemiologia , Osteólise/etiologia , Prevalência , Falha de Prótese , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Sistema de Registros/estatística & dados numéricos , Reprodutibilidade dos Testes , República da Coreia/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
10.
BMC Musculoskelet Disord ; 18(1): 266, 2017 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-28623889

RESUMO

BACKGROUND: The optimal surgical option for patients requiring bilateral hip replacement remains controversial. The purpose of this study was to compare surgical accuracy; functional outcome and health-related quality of life; and prosthetic-related complications and revision surgery of a simultaneous bilateral total hip arthroplasty (THA) with those of a staged bilateral THA with an interval between procedures <12 months. METHODS: A total of 123 unselected consecutive patients (mean age, 43.3 years) who underwent bilateral THAs for osteonecrosis of the femoral head (ONFH) with a minimum follow-up of two years (mean, 60.2 months) were studied retrospectively; 63 simultaneous procedures served as a test group and 60 staged procedures served as a control group. RESULTS: The mean postoperative leg-length discrepancy (LLD) and the percentage of patients who had an LLD >3 mm were significantly lower in the simultaneous group (P < 0.001 and P = 0.001, respectively). A higher number of cups within the safe zones, a higher correction rate, and a lower failure rate for the cup placement in the second-operated hip were also identified in the simultaneous group. The mean Harris hip score, EuroQol-5D index, and EuroQol-visual analogue scale score were all better in the simultaneous group at the latest follow-up (P < 0.001, in all comparisons). We found that the simultaneous procedure was associated with a lower incidence of postoperative prosthetic-related complications and revision surgery. CONCLUSIONS: We suggest that bilateral ONFH could be treated with a simultaneous THA rather than a staged THA to achieve a better surgical outcome.


Assuntos
Artroplastia de Quadril/normas , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Desenho de Prótese/normas , Qualidade de Vida , Recuperação de Função Fisiológica , Adolescente , Adulto , Idoso , Artroplastia de Quadril/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
11.
Environ Health Prev Med ; 22(1): 34, 2017 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-29165122

RESUMO

BACKGROUND: Carbon monoxide (CO) is one of the primary components of emissions from light-duty vehicles, and reportedly comprises 77% of all pollutants emitted in terms of concentration. Exposure to CO aggravates cardiovascular disease and causes other health disorders. The study was aimed to assess the negative effects by injecting different amounts of CO concentration directly to human volunteers boarding in the car. METHODS: Human volunteers were exposed to CO concentrations of 0, 33.2, and 72.4 ppm, respectively during the first test and 0, 30.3, and 48.8 ppm respectively during the second test while seated in the car. The volunteers were exposed to each concentration for approximately 45 min. After exposure, blood pressure measurement, blood collection (carboxyhemoglobin [COHb] analysis), medical interview, echocardiography test, and cognitive reaction test were performed. RESULT: In patients who were exposed to a mean concentration of CO for 72.4 ± 1.4 ppm during the first exposure test and 48.8 ± 3.7 ppm during the second exposure test, the COHb level exceeded 2%. Moreover, the diastolic blood pressure was decreased while increasing in CO concentration after exposure. The medical interview findings showed that the degree of fatigue was increased and the degree of concentration was reduced when the exposed concentration of CO was increased. CONCLUSION: Although the study had a limited sample size, we found that even a low concentration of CO flowing into a car could have a negative influence on human health, such as change of blood pressure and degree of fatigue.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Monóxido de Carbono/efeitos adversos , Carboxihemoglobina/análise , Adulto , Análise de Variância , Monóxido de Carbono/administração & dosagem , Monóxido de Carbono/análise , Cognição , Ecocardiografia , Monitoramento Ambiental , Feminino , Humanos , Hipotensão/induzido quimicamente , Masculino , Pessoa de Meia-Idade , República da Coreia , Emissões de Veículos/toxicidade , Voluntários
12.
J Arthroplasty ; 31(11): 2597-2602, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27267227

RESUMO

BACKGROUND: A contralateral normal hip joint has been often used as a reference standard in preoperative planning and intraoperative assessment of hip arthroplasty, with the assumption that bilateral hip joint geometries have no significant differences. However, one previous study using analog measurements on hardcopy films reported significant bilateral variation in hip joint geometry. We therefore investigated the level of agreement between the right and left hips for each measurement and determined index values and the range of normal bilateral variations. METHODS: We assessed 100 standard anteroposterior radiographs of the pelvis in this study. Two independent observers measured the actual value of femoral head diameter, location of the femoral head center, acetabular offset, femoral offset, hip offset, greater trochanteric height, neck-shaft angle, medullary canal diameter, and proximal femoral diameter. Intraclass correlation coefficients (ICCs) and values of mean difference were calculated for each measurement. RESULTS: The results demonstrated perfect agreement (ICC >0.8) between the right and left hips for most parameters and substantial agreement for greater trochanteric height (ICC = 0.735) and femoral offset (ICC = 0.773). The mean difference and standard deviation in the measurement between the right and left hips for the location of the femoral head center and the acetabular offset were 0.60 ± 0.48 mm and 0.42 ± 0.30 mm, respectively. CONCLUSION: Hip joint geometry is not influenced by side. In hip arthroplasty, a contralateral normal hip can be reliably used as a guide for preoperative planning using measurement tools on a picture archiving and communication system.


Assuntos
Cabeça do Fêmur/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Radiografia/métodos , Acetábulo/diagnóstico por imagem , Adulto , Feminino , Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistemas de Informação em Radiologia , Valores de Referência , República da Coreia , Adulto Jovem
13.
Environ Geochem Health ; 37(2): 321-32, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25255774

RESUMO

The objective of this study is to find the Cd levels in agricultural crops compared to soil, to evaluate the relationship between daily intake dose through the multimedia/multi-pathway of human exposure and biomarker levels of the residents in mine vicinity area. We collected and cited the data of four out of ten health impact assessments for the residents of abandoned mine areas undertaken by the Korea Ministry of Environment in 2008. The Cd levels in soil were significantly decreased by the separation distance from the mines. The Cd levels in blood were significantly different between residents in mine areas and in comparative areas, but urinary Cd levels did not differ. The Cd levels in blood were related to the age; the separation distance from mine to residence; the daily intake dose via ingestion of drinking water, crops, and surface soil; and inhalation of ambient air of Cd, but urinary Cd levels were not relevant with various sociodemographic characteristics and exposure factors. The average hazard quotient (HQ) value of Cd in the mining site was below 1.0, but the maximum HQ was closed to 1.0. The results indicated that the ingestion of Cd-contaminated soil and agricultural crops by local inhabitants could pose potential adverse health effects to long-term residents consuming rice grown near to the mining areas.


Assuntos
Poluentes Atmosféricos/análise , Cádmio/análise , Poluição Ambiental/análise , Poluentes do Solo/análise , Poluentes Químicos da Água/análise , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Poluentes Atmosféricos/sangue , Poluentes Atmosféricos/urina , Cádmio/sangue , Cádmio/urina , Criança , Monitoramento Ambiental , Feminino , Contaminação de Alimentos/análise , Humanos , Masculino , Pessoa de Meia-Idade , Mineração , Oryza/química , República da Coreia , Medição de Risco , Poluentes do Solo/sangue , Poluentes do Solo/urina , Poluentes Químicos da Água/sangue , Poluentes Químicos da Água/urina , Zea mays/química
14.
ACS Nano ; 18(14): 10045-10053, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38527965

RESUMO

Hybridization of microbial cells with inorganic nanoparticles that could dramatically improve cellular functions such as electron transfer has been realized by the random attachment or stochastic entry of the nanoparticles. Clearly, the selective growth of inorganic nanoparticles on target functional organelles is ideal for such hybridization. Here, we report the selective growth of gold nanocrystals in the intermembrane space (IMS) of Escherichia coli by exploiting the electron transport chain (ETC). We systematically show that gold ions are permeated through porins in the outer membrane of E. coli and further reduced to gold nanocrystals by the ETC in live E. coli. We directly observe that the resulting gold nanocrystals exist only in the IMS by transmission electron microscopy measurements of cross-sectioned E. coli. Molecular dynamics simulations suggest that once gold ions are reduced to small nuclei by the ETC, the nuclei can be stably physisorbed onto ETC complexes, further supporting the ETC-mediated growth. Finally, we show that the ATP synthesis of E. coli where gold nanocrystals are formed in the IMS is up to 9 times higher than that of E. coli alone. We believe that our work can significantly contribute to not only improving microbial metabolic functions for biological energy conversion but also restoring physiological dysfunctions of microbial cells for biomedicine.


Assuntos
Escherichia coli , Nanopartículas , Ouro/química , Elétrons , Íons
15.
Hip Pelvis ; 36(1): 47-54, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38420737

RESUMO

Purpose: Venous thromboembolism (VTE) is a major complication for hip fracture patients, and may exist preoperatively. This study aimed to examine the prevalence of VTE after immediate screening in hip fracture patients. Materials and Methods: Hip fracture patients with an elevated level of D-dimer underwent screening for VTE using computed tomography (CT) angiography. Anticoagulation treatments were administered preoperatively to patients diagnosed with VTE, followed by administration of additional anticoagulation postoperatively. Medical records were reviewed to identify risk factors for preoperative VTE and determine the prognosis of the patients. Results: Among 524 hip fracture patients, 66 patients (12.6%) were diagnosed with VTE, including 42 patients with deep vein thrombosis (DVT), 17 patients with pulmonary thromboembolism (PTE), and 7 patients with both DVT and PTE. Of the patients with VTE, 68.2% were diagnosed within 24 hours of injury, and 33.3% of these patients had PTE. VTE patients showed a tendency toward being overweight (P<0.01) and not on anticoagulant medication (P=0.02) compared to patients without VTE. The risk of VTE was higher for femur shaft fractures (odds ratio [OR] 4.83, 95% confidence interval [CI] 2.18-10.69) and overweight patients (OR 2.12, 95% CI 1.17-3.85), and lower for patients who were previously on anticoagulants (OR 0.36, 95% CI 0.18-0.74). Patients with preoperatively diagnosed VTE were asymptomatic before and after surgery. Conclusion: Clinicians should be aware that VTE may be present within 24 hours of injury, and screening for VTE or prophylactic measures should be considered for high-risk patients.

16.
Orthop Surg ; 15(10): 2591-2601, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37526171

RESUMO

OBJECTIVE: This is a rare study comparing the radiological and functional outcomes of fixation after reduction with in situ fixation group using Femoral Neck System (FNS). The aim of this study was to introduce a simple, innovative, minimally invasive method to reduce valgus-impacted and tilted femoral neck fractures without soft tissue or cartilage injury. METHODS: A retrospective comparative analysis of 46 patients between May 2020 and February 2022 was performed. In the control group, 23 patients underwent in situ fixation without reduction. In the study group, another 23 patients were managed by fixation after reduction using a percutaneous pull-out technique with a full threaded Steinmann pin. Caput-collum-diaphysis (CCD) angle, tilt, and femoral neck shortenings were compared between the two groups. In addition, Harris Hip Score (HHS) was evaluated and compared at 1 year after surgery. Basically, independent samples t-test was used to compare radiological and functional results. RESULTS: Patients' initial valgus and tilt angles were not significantly different between the groups (n.s.). However, the CCD and tilt angles measured immediately and at one year postoperatively were significantly different between the groups (p < 0.05). Regarding femoral neck shortening, shortening in the three directions, the x, y, and z vectors, was significantly less in the reduction group immediately postoperatively and at 1 year post-surgery (p < 0.05). The mean HHS at 1 year postoperatively was 79.7 ± 8.4 in the in situ fixation group and 87.9 ± 6.6 in the reduction groups, and there was a significant difference (p < 0.05). CONCLUSION: The pull-out method with a threaded Steinmann pin to reduce valgus-impacted and tilted femoral neck fracture is safe and effective for accomplishing anatomical restoration. This may achieve successful bone union and maintain the femoral neck length and original tilt without nearby soft tissue or cartilage injury.

17.
Eur J Trauma Emerg Surg ; 49(2): 991-1000, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36446946

RESUMO

PURPOSE: Osteonecrosis of the femoral head (ONFH) and subsequent head collapse is a major concern after internal fixation of femoral neck fracture (FNF). Previous studies focused on ONFH incidence using plain radiography; postoperative magnetic resonance imaging (MRI) was rarely performed. We performed a multicenter retrospective study to investigate the incidence of ONFH and the need for conversion hip arthroplasty after FNF screw fixation. METHODS: We reviewed 195 patients who underwent screw fixation during closed FNF reduction between 2012 and 2017 at three institutions. Except for patients who did not consent to MRI, all patients underwent postoperative MRI either 1-3 years after screw fixation. The occurrence of ONFH was investigated through plain radiography and MRI. RESULTS: Thirty patients were diagnosed with ONFH through plain radiography, and an additional 33 patients were diagnosed with MRI, resulting in a total of 63 patients (32.3%) diagnosed with ONFH. The mean time to ONFH diagnosis was 18.9 months and the conversion rate to hip arthroplasty was 10.2%. Of the 33 patients who were normal on hip radiography but exhibited ONFH on MRI, all had small focal lesions not associated with head collapse at the last follow-up. The ONFH group diagnosed through plain radiography had more unstable FNFs than the group diagnosed through MRI. CONCLUSION: Although postoperative MRI revealed a higher incidence of ONFH after FNF screw fixation than reported previously, the small focal MRI lesions were not associated with increased risks of femoral head collapse or conversion to arthroplasty.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Necrose da Cabeça do Fêmur , Humanos , Cabeça do Fêmur/diagnóstico por imagem , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Incidência , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/epidemiologia , Fraturas do Colo Femoral/cirurgia , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/epidemiologia , Necrose da Cabeça do Fêmur/etiologia , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Parafusos Ósseos/efeitos adversos , Estudos Multicêntricos como Assunto
18.
J Orthop Surg Res ; 18(1): 354, 2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37173688

RESUMO

BACKGROUND: In revision surgery with significant segmental acetabular defects, adequate implant selection and fixation methods are critical in determining successful bony ingrowth. Commercially available total hip prosthesis manufacturers generally offer additional multi-hole options of acetabular shells with identical designs for use in revision THAs where screw holes configurations vary from product to product. This study aims to compare the mechanical stability of the two types of acetabular screw constructs for the fixation of acetabular components: spread-out and pelvic brim-focused configurations. METHODS: We prepared 40 synthetic bone models of the male pelvis. In half of the samples with acetabular defects, identical curvilinear bone defects were manually created using an oscillating electrical saw. On the right side, multi-hole-cups in which the direction of the screw holes are centered on the pelvic brim (brim-focused) and, on the left side, multi-hole-cups with the direction of the screw hole spread throughout the acetabulum (spread-out) were implanted into the pelvic synthetic bones. Coronal lever-out and axial torsion tests were performed with a testing machine, measuring load versus displacement. RESULTS: The average torsional strengths were significantly higher in the spread-out group over the brim-focused group regardless of the presence of the segmental defect of the acetabulum (p < 0.001). But for the lever-out strength, the spread-out group exhibited significantly higher average strength over the brim-focused group for the intact acetabulum (p = 0.004), whereas the results were reversed in the brim-focused group when the defects were generated (p < 0.001). The presence of acetabular defects reduced the average torsional strengths of the two groups by 68.66% versus 70.86%. In comparison, the decrease in the average lever-out strength was less significant for the brim-focused group than the spread-out group (19.87% vs. 34.25%) (p < 0.001). CONCLUSION: Constructs of multi-hole acetabular cups with the spread-out screw holes configuration exhibited statistically better axial torsional strength and coronal lever-out strength. With the presence of posterior segmental bone defects, the spread-out constructs demonstrated significantly better tolerance to axial torsional strength. Still, they exhibited inverted results of higher lever-out strength in the pelvic brim-focused constructs.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Masculino , Humanos , Acetábulo/cirurgia , Reoperação , Parafusos Ósseos , Desenho de Prótese
19.
Sci Rep ; 13(1): 14792, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37684351

RESUMO

Most medical implants are made of titanium. When titanium is exposed to air for a long time, hydrocarbons are deposited and the surface becomes hydrophobic. Cell attachment is important for bone ingrowth to occur on the implant surface, and hydrophilicity can enhance this. We examined whether non-thermal atmospheric pressure plasma treatment could increase the hydrophilicity of the titanium surface. Samples coated with four widely used coating types [grit blasting, micro arc oxidation (MAO), titanium plasma spray (TPS), and direct metal fabrication (DMF)] were treated with plasma. Each of the four surface-treated samples was divided into groups with and without plasma treatment. We analysed wettability by surface analysis and evaluation of contact angles, cell proliferation, and adhesion using scanning electron microscopy (SEM), confocal laser scanning microscopy, absorbance tests, and alkaline phosphatase (ALP) activity assay; four different Ti6Al4V surface types were compared. After plasma treatment, the contact angle was reduced on all surfaces, and the carbon content was reduced on all surfaces based on X-ray photoelectron spectroscopy (XPS) surface analysis. Under confocal laser scanning, the cell layer was thicker on the plasma-treated samples, especially in groups TPS and DMF. Cell proliferation was 41.8%, 17.7%, 54.9%, and 83.8% greater for the plasma- than non-plasma-treated grit blasting, MAO, TPS, and DMF samples, respectively. Hydrophilicity increased significantly under plasma treatment, and biological responsivity was also improved.


Assuntos
Ligas , Gases em Plasma , Titânio/farmacologia , Gases em Plasma/farmacologia , Molhabilidade , Proliferação de Células
20.
Biosens Bioelectron ; 237: 115489, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37402347

RESUMO

Polymerase chain reaction (PCR) in small fluidic systems not only improves speed and sensitivity of deoxyribonucleic acid (DNA) amplification but also achieves high-throughput quantitative analyses. However, air bubble trapping and growth during PCR has been considered as a critical problem since it causes the failure of DNA amplification. Here we report bubble-free diatom PCR by exploiting a hierarchically porous silica structure of single-celled algae. We show that femtoliters of PCR solution can be spontaneously loaded into the diatom interior without air bubble trapping due to the surface hydrophilicity and pore structure of the diatom. We discover that a large pressure gradient between air bubbles and nanopores rapidly removes residual air bubbles through the periodically arrayed nanopores during thermal cycling. We demonstrate the DNA amplification by diatom PCR without air bubble trapping and growth. Finally, we successfully detect DNA fragments of SARS-CoV-2 with as low as 10 copies/µl by devising a microfluidic device integrated with diatoms assembly. We believe that our work can be applied to many PCR applications for innovative molecular diagnostics and provides new opportunities for naturally abundant diatoms to create innovative biomaterials in real-world applications.


Assuntos
Técnicas Biossensoriais , COVID-19 , Diatomáceas , Humanos , Diatomáceas/genética , Diatomáceas/química , SARS-CoV-2/genética , Reação em Cadeia da Polimerase , DNA/genética , Teste para COVID-19
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA