Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Rhinology ; 62(1): 55-62, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37772802

RESUMO

BACKGROUND: Although the COVID-19 pandemic has increased the prevalence of cases with olfactory loss, other respiratory viruses can also cause this condition. We aimed to compare the prevalence of acute SARS-CoV-2 infection and other respiratory viruses in patients with sudden smell loss, and to assess the impact of SARS-CoV-2 viral load and co-infection on olfactory symptoms. METHODS: Patients with sudden smell loss were recruited in a multicenter prospective cohort study in 15 hospitals in Brazil. Clinical questionnaire, Connecticut Chemosensory Clinical Research Center (CCCRC) olfactory test and nasopharyngeal swab to perform a PCR-based respiratory viral panel were collected at first visit (day 0) and 30 and 60 days after recruitment. RESULTS: 188 of 213 patients presented positive test result for SARS-CoV-2, among which 65 were co-infected with other respiratory viruses (e.g., rhinovirus, enterovirus, and parainfluenza). 25 had negative test results for SARS-CoV-2. Patients in both SARSCoV-2 and non-SARS-CoV-2 groups had objective anosmia (less than 2 points according to the psychophysical olfactory CCCRC) at day 0, with no significant difference between them. Both groups had significant smell scores improvement after 30 and 60 days, with no difference between them. Co-infection with other respiratory viruses, and SARS-CoV-2 viral load did not impact olfactory scores. CONCLUSION: Patients with sudden smell loss associated with SARS-CoV-2 and other respiratory viruses had similar presentation, with most participants initiating with anosmia, and total or near total recovery after 60 days. SARS-CoV-2 viral load and co-infections with other respiratory viruses were not associated with poorer olfactory outcomes.


Assuntos
COVID-19 , Coinfecção , Transtornos do Olfato , Humanos , SARS-CoV-2 , COVID-19/complicações , Anosmia/complicações , Anosmia/epidemiologia , Estudos Prospectivos , Pandemias , Coinfecção/complicações , Coinfecção/epidemiologia , Transtornos do Olfato/diagnóstico , Transtornos do Olfato/epidemiologia , Transtornos do Olfato/etiologia , Olfato
2.
Eur J Radiol Open ; 7: 100294, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33283031

RESUMO

INTRODUCTION: The outbreak of a highly infectious respiratory disease - COVID-19 - has spread globally and a novel type of coronavirus (SARS-CoV-2) was identified as its cause. Chest CT findings have been described as an aid for COVID-19 diagnosis and management. We aimed to describe the CT imaging characteristics in a group of COVID-19 patients while we also intended to assess if any of these radiological features were associated with short-term prognosis. MATERIALS AND METHODS: CT examinations from 164 consecutive patients with at least one positive RT-PCR nucleic acid assay for SARS-CoV-2 were retrospectively analyzed. Numerous CT imaging features were recorded independently by two radiologists. Patients were grouped according to their status 14 days after the initial CT scan in either discharged/hospitalized in a non-ICU ward (favorable prognosis group) versus deceased/admitted to an intensive care unit (unfavorable prognosis group). RESULTS: Ground-glass opacities (89.0 %) and consolidations (73.2 %) with multilobar involvement were the predominant imaging findings, while a nodular pattern (3.7 %) and cavitation (1.2 %) were uncommon. Mean age was higher in the mortality/ICU group. Ground-glass opacities and consolidations were dominant in both groups, but distribution pattern of abnormalities was different, being more often diffuse in the mortality/ICU group. Linear opacities and opacities that were rounded in shape were more frequently observed in the favorable prognosis group. CT severity index was significantly higher in the mortality/ICU group. For assessing unfavorable prognosis, the best cut-off for CT severity index was 24 (sensitivity 78 %; specificity 59 %). Interobserver agreement for all CT findings was excellent. CONCLUSION: COVID-19 pneumonia in Porto, Portugal, manifests as multilobar ground-glass opacities and consolidations. Older age, diffuse distribution and increasing CT severity index are associated with worse short-term prognosis while linear opacities resembling organizing pneumonia and rounded opacities herald a more favorable prognosis.

3.
Ars Vet. ; 37(1): 35-38, 2021. tab
Artigo em Inglês | VETINDEX | ID: vti-30651

RESUMO

With a view to reducing stress and discomfort and improving the practicality of making temperature measurements on cats, the aim of this study was to evaluate the use of a tympanic infrared thermometer (TIT), which is an easy-to-use device for measuring temperatures quickly, comfortably and more hygienically. For this, were selected 120 domestic cats living in Sousa, Paraíba, northeastern Brazil. Among them, 100 were normothermic, ten were hypothermic and ten were hyperthermic. None of them had any clinical signs of external or internal otitis. The measurements using the digital thermometer were higher than those using the TIT (P < 0.05), in the normothermic and hyperthermic cats. In the hypothermic cats, there was no difference (P ≥ 0.05) in mean values from the three types of thermometer. The values obtained using the mercury thermometer did not differ (P ≥ 0.05) from the values obtained using the other thermometers. There was a strong positive correlation in almost all the evaluations between the three thermometers, except for digital versus TIT for hyperthermic cats (r < 0.75). Because of the discrepancy between the values obtained by the TIT and the digital rectal thermometer, we suggest that further studies should be carried out in order to establish a temperature correction table for the TIT, so that it can be better used in veterinary medicine.(AU)


Com o objetivo de reduzir o estresse, desconforto e melhorar a praticidade da medição da temperatura em gatos, o objetivo deste estudo foi avaliar o uso de um termômetro timpânico infravermelho (TTI), que é um dispositivo de fácil utilização para medição de temperatura de forma rápida, confortável e higiênica. Para isso, foram selecionados 120 gatos domésticos criados no município de Sousa, Paraíba, Nordeste do Brasil. Dentre eles, 100 eram normotérmicos, dez hipotérmicos e dez hipertérmicos. Nenhum deles apresentava sinais clínicos de otite externa ou interna.(AU)


Assuntos
Animais , Gatos , Gatos/anatomia & histologia , Gatos/fisiologia , Termômetros/veterinária , Raios Infravermelhos
4.
Ars vet ; 37(1): 35-38, 2021. tab
Artigo em Inglês | VETINDEX | ID: biblio-1463566

RESUMO

With a view to reducing stress and discomfort and improving the practicality of making temperature measurements on cats, the aim of this study was to evaluate the use of a tympanic infrared thermometer (TIT), which is an easy-to-use device for measuring temperatures quickly, comfortably and more hygienically. For this, were selected 120 domestic cats living in Sousa, Paraíba, northeastern Brazil. Among them, 100 were normothermic, ten were hypothermic and ten were hyperthermic. None of them had any clinical signs of external or internal otitis. The measurements using the digital thermometer were higher than those using the TIT (P < 0.05), in the normothermic and hyperthermic cats. In the hypothermic cats, there was no difference (P ≥ 0.05) in mean values from the three types of thermometer. The values obtained using the mercury thermometer did not differ (P ≥ 0.05) from the values obtained using the other thermometers. There was a strong positive correlation in almost all the evaluations between the three thermometers, except for digital versus TIT for hyperthermic cats (r < 0.75). Because of the discrepancy between the values obtained by the TIT and the digital rectal thermometer, we suggest that further studies should be carried out in order to establish a temperature correction table for the TIT, so that it can be better used in veterinary medicine.


Com o objetivo de reduzir o estresse, desconforto e melhorar a praticidade da medição da temperatura em gatos, o objetivo deste estudo foi avaliar o uso de um termômetro timpânico infravermelho (TTI), que é um dispositivo de fácil utilização para medição de temperatura de forma rápida, confortável e higiênica. Para isso, foram selecionados 120 gatos domésticos criados no município de Sousa, Paraíba, Nordeste do Brasil. Dentre eles, 100 eram normotérmicos, dez hipotérmicos e dez hipertérmicos. Nenhum deles apresentava sinais clínicos de otite externa ou interna.


Assuntos
Animais , Gatos , Gatos/anatomia & histologia , Gatos/fisiologia , Raios Infravermelhos , Termômetros/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA