RESUMO
The phase state of respiratory aerosols and droplets has been linked to the humidity-dependent survival of pathogens such as SARS-CoV-2. To inform strategies to mitigate the spread of infectious disease, it is thus necessary to understand the humidity-dependent phase changes associated with the particles in which pathogens are suspended. Here, we study phase changes of levitated aerosols and droplets composed of model respiratory compounds (salt and protein) and growth media (organic-inorganic mixtures commonly used in studies of pathogen survival) with decreasing relative humidity (RH). Efflorescence was suppressed in many particle compositions and thus unlikely to fully account for the humidity-dependent survival of viruses. Rather, we identify organic-based, semisolid phase states that form under equilibrium conditions at intermediate RH (45 to 80%). A higher-protein content causes particles to exist in a semisolid state under a wider range of RH conditions. Diffusion and, thus, disinfection kinetics are expected to be inhibited in these semisolid states. These observations suggest that organic-based, semisolid states are an important consideration to account for the recovery of virus viability at low RH observed in previous studies. We propose a mechanism in which the semisolid phase shields pathogens from inactivation by hindering the diffusion of solutes. This suggests that the exogenous lifetime of pathogens will depend, in part, on the organic composition of the carrier respiratory particle and thus its origin in the respiratory tract. Furthermore, this work highlights the importance of accounting for spatial heterogeneities and time-dependent changes in the properties of aerosols and droplets undergoing evaporation in studies of pathogen viability.
Assuntos
Cloreto de Cálcio/química , Modelos Químicos , Aerossóis e Gotículas Respiratórios/química , SARS-CoV-2/química , Albumina Sérica/química , Cloreto de Sódio/química , COVID-19/virologia , Difusão , Desinfecção/métodos , Humanos , Umidade , Cinética , Viabilidade Microbiana , Transição de Fase , Propriedades de SuperfícieRESUMO
BACKGROUND: Quantifying the dose and distribution of tobacco smoke in the respiratory system is critical for understanding its toxicity, addiction potential, and health impacts. Epidemiologic studies indicate that the incidence of lung tumors varies across different lung regions, suggesting there may be a heterogeneous deposition of smoke particles leading to greater health risks in specific regions. Despite this, few studies have examined the lobar spatial distribution of inhaled particles from tobacco smoke. This gap in knowledge, coupled with the growing popularity of little cigars among youth, underscores the need for additional research with little cigars. RESULTS: In our study, we analyzed the lobar deposition in rat lungs of smoke particles from combusted regular and mentholated Swisher Sweets little cigars. Twelve-week-old male and female Sprague-Dawley rats were exposed to smoke particles at a concentration of 84 ± 5 mg/m3 for 2 h, after which individual lung lobes were examined. We utilized Inductively Coupled Plasma Mass Spectrometry to quantify lobar chromium concentrations, serving as a smoke particle tracer. Our findings demonstrated an overall higher particle deposition from regular little cigars than from the mentholated ones. Higher particle deposition fraction was observed in the left and caudal lobes than other lobes. We also observed sex-based differences in the normalized deposition fractions among lobes. Animal study results were compared with the multi-path particle dosimetry (MPPD) model predictions, which showed that the model overestimated particle deposition in certain lung regions. CONCLUSIONS: Our findings revealed that the particle deposition varied between different little cigar products. The results demonstrated a heterogenous deposition pattern, with higher particle deposition observed in the left and caudal lobes, especially with the mentholated little cigars. Additionally, we identified disparities between our measurements and the MPPD model. This discrepancy highlights the need to enhance the accuracy of models before extrapolating animal study results to human lung deposition. Overall, our study provides valuable insights for estimating the dose of little cigars during smoking for toxicity research.
Assuntos
Produtos do Tabaco , Poluição por Fumaça de Tabaco , Humanos , Ratos , Animais , Adolescente , Masculino , Feminino , Ratos Sprague-Dawley , Pulmão , Produtos do Tabaco/análise , CromoRESUMO
The transmission of some infectious diseases requires that pathogens can survive (i.e., remain infectious) in the environment, outside the host. Relative humidity (RH) is known to affect the survival of some microorganisms in the environment; however, the mechanism underlying the relationship has not been explained, particularly for viruses. We investigated the effects of RH on the viability of bacteria and viruses in both suspended aerosols and stationary droplets using traditional culture-based approaches. Results showed that viability of bacteria generally decreased with decreasing RH. Viruses survived well at RHs lower than 33% and at 100%, whereas their viability was reduced at intermediate RHs. We then explored the evaporation rate of droplets consisting of culture media and the resulting changes in solute concentrations over time; as water evaporates from the droplets, solutes such as sodium chloride in the media become more concentrated. Based on the results, we suggest that inactivation of bacteria is influenced by osmotic pressure resulting from elevated concentrations of salts as droplets evaporate. We propose that the inactivation of viruses is governed by the cumulative dose of solutes or the product of concentration and time, as in disinfection kinetics. These findings emphasize that evaporation kinetics play a role in modulating the survival of microorganisms in droplets.
Assuntos
Desinfecção , Vírus , Aerossóis , Bactérias , Umidade , CinéticaRESUMO
Pandemic and seasonal influenza viruses can be transmitted through aerosols and droplets, in which viruses must remain stable and infectious across a wide range of environmental conditions. Using humidity-controlled chambers, we studied the impact of relative humidity on the stability of 2009 pandemic influenza A(H1N1) virus in suspended aerosols and stationary droplets. Contrary to the prevailing paradigm that humidity modulates the stability of respiratory viruses in aerosols, we found that viruses supplemented with material from the apical surface of differentiated primary human airway epithelial cells remained equally infectious for 1 hour at all relative humidities tested. This sustained infectivity was observed in both fine aerosols and stationary droplets. Our data suggest, for the first time, that influenza viruses remain highly stable and infectious in aerosols across a wide range of relative humidities. These results have significant implications for understanding the mechanisms of transmission of influenza and its seasonality.
Assuntos
Aerossóis , Umidade , Vírus da Influenza A Subtipo H1N1/fisiologia , Viabilidade Microbiana , Células Cultivadas , Exposição Ambiental , Células Epiteliais/virologia , Humanos , Fatores de TempoRESUMO
Infectious diseases caused by enveloped viruses, such as influenza, severe acute respiratory syndrome (SARS), and Middle East respiratory syndrome (MERS), cause thousands of deaths and billions of dollars of economic losses per year. Studies have found a relationship among temperature, humidity, and influenza virus incidence, transmission, or survival; however, there are contradictory claims about whether absolute humidity (AH) or relative humidity (RH) is most important in mediating virus infectivity. Using the enveloped bacteriophage Phi6, which has been suggested as a surrogate for influenza viruses and coronaviruses, we designed a study to discern whether AH, RH, or temperature is a better predictor of virus survival in droplets. Our results show that Phi6 survived best at high (>85%) and low (<60%) RHs, with a significant decrease in infectivity at mid-range RHs (â¼60 to 85%). At an AH of less than 22 g · m-3, the loss in infectivity was less than 2 orders of magnitude; however, when the AH was greater than 22 g · m-3, the loss in infectivity was typically greater than 6 orders of magnitude. At a fixed RH of 75%, infectivity was very sensitive to temperature, decreasing two orders of magnitude between 19°C and 25°C. We used random forest modeling to identify the best environmental predictors for modulating virus infectivity. The model explained 83% of variation in Phi6 infectivity and suggested that RH is the most important factor in controlling virus infectivity in droplets. This research provides novel information about the complex interplay between temperature, humidity, and the survival of viruses in droplets.IMPORTANCE Enveloped viruses are responsible for a number of infectious diseases resulting in thousands of deaths and billions of dollars of economic losses per year in the United States. There has been a lively debate in the literature over whether absolute humidity (AH) or relative humidity (RH) modulates virus infectivity. We designed a controlled study and used advanced statistical modeling techniques specifically to address this question. By providing an improved understanding of the relationship between environmental conditions and virus infectivity, our work will ultimately lead to improved strategies for predicting and controlling disease transmission.
Assuntos
Bacteriófagos/fisiologia , Umidade , Gotículas Lipídicas/virologia , Temperatura , Inativação de Vírus , Fenômenos Fisiológicos ViraisRESUMO
Recent studies have shown that Ebola virus can persist in wastewater. We evaluated the potential for Ebola virus surrogates to be aerosolized from three types of wastewater systems: toilets, a lab-scale model of an aeration basin, and a lab-scale model of converging sewer pipes. We measured the aerosol size distribution generated by each system, spiked Ebola virus surrogates (MS2 and Phi6) into each system, and determined the emission rate of viruses into the air. The number of aerosols released ranged from 105 to 107 per flush from the toilets or per minute from the lab-scale models, and the total volume of aerosols generated by these systems was â¼10-9 to 10-7 mL per flush or per minute in all cases. MS2 and Phi6, spiked into toilets at an initial concentration of 107 plaque-forming units per milliliter (PFU mL-1), were not detected in air after flushing. Airborne concentrations of MS2 and Phi6 were â¼20 PFU L-1 and â¼0.1 PFU L-1, respectively, in the chambers enclosing the aeration basin and sewer models. The corresponding emission rates of MS2 and Phi6 were 547 PFU min-1 and 3.8 PFU min-1, respectively, for the aeration basin and 79 PFU min-1 and 0.3 PFU min-1 for the sewer pipes.
Assuntos
Ebolavirus , Águas Residuárias , Aerossóis , Doença pelo Vírus EbolaRESUMO
We conducted a critical review to establish what is known about the sources, characteristics, and dissemination of ARGs in the atmosphere. We identified 52 papers that reported direct measurements of bacterial ARGs in air samples and met other inclusion criteria. The settings of the studies fell into the following categories: urban, rural, hospital, industrial, wastewater treatment plants (WWTPs), composting and landfill sites, and indoor environments. Certain genes were commonly studied and generally abundant: sul1, intI1, ß-lactam ARGs, and tetracycline ARGs. Abundances of total ARGs varied by season and setting, with air in urban areas having higher ARG abundance than rural areas during the summer and vice versa during the winter. There was greater consistency in the types and abundances of ARGs throughout the seasons in urban areas. Human activity within indoor environments was also linked to increased ARG content (abundance, diversity, and concentration) in the air. Several studies found that human exposure to ARGs through inhalation was comparable to exposure through drinking water or ingesting soil. Detection of ARGs in air is a developing field, and differences in sampling and analysis methods reflect the many possible approaches to studying ARGs in air and make direct comparisons between studies difficult. Methodologies need to be standardized to facilitate identification of the dominant ARGs in the air, determine their major sources, and quantify the role of atmospheric transport in dissemination of ARGs in the environment. With such knowledge we can develop better policies and guidelines to limit the spread of antimicrobial resistance.
Assuntos
Antibacterianos , Genes Bacterianos , Antibacterianos/análise , Antibacterianos/farmacologia , Atmosfera , Bactérias/genética , Resistência Microbiana a Medicamentos/genética , Humanos , Águas Residuárias/análiseRESUMO
The survival of viruses in droplets is known to depend on droplets' chemical composition, which may vary in respiratory fluid between individuals and over the course of disease. This relationship is also important for understanding the persistence of viruses in droplets generated from wastewater, freshwater, and seawater. We investigated the effects of salt (0, 1, and 35 g/L), protein (0, 100, and 1000 µg/mL), surfactant (0, 1, and 10 µg/mL), and droplet pH (4.0, 7.0, and 10.0) on the viability of viruses in 1-µL droplets pipetted onto polystyrene surfaces and exposed to 20%, 50%, and 80% relative humidity (RH) using a culture-based approach. Results showed that viability of MS2, a non-enveloped virus, was generally higher than that of Φ6, an enveloped virus, in droplets after 1 hour. The chemical composition of droplets greatly influenced virus viability. Specifically, the survival of MS2 was similar in droplets at different pH values, but the viability of Φ6 was significantly reduced in acidic and basic droplets compared to neutral ones. The presence of bovine serum albumin protected both MS2 and Φ6 from inactivation in droplets. The effects of sodium chloride and the surfactant sodium dodecyl sulfate varied by virus type and RH. Meanwhile, RH affected the viability of viruses as shown previously: viability was lowest at intermediate to high RH. The results demonstrate that the viability of viruses is determined by the chemical composition of carrier droplets, especially pH and protein content, and environmental factors. These findings emphasize the importance of understanding the chemical composition of carrier droplets in order to predict the persistence of viruses contained in them.
Assuntos
Cystoviridae/fisiologia , Levivirus/fisiologia , Viabilidade Microbiana/efeitos dos fármacos , Cloreto de Sódio/farmacologia , Tensoativos/farmacologia , Umidade , Concentração de Íons de Hidrogênio , Poliestirenos/química , Proteínas/química , Proteínas/farmacologia , Tensoativos/químicaRESUMO
BACKGROUND: During a period of rapid growth in our understanding of the microbiology of the built environment in recent years, the majority of research has focused on bacteria and fungi. Viruses, while probably as numerous, have received less attention. In response, the Alfred P. Sloan Foundation supported a workshop entitled "Viruses in the Built Environment (VIBE)," at which experts in environmental engineering, environmental microbiology, epidemiology, infection prevention, fluid dynamics, occupational health, metagenomics, and virology convened to synthesize recent advances and identify key research questions and knowledge gaps regarding viruses in the built environment. RESULTS: Four primary research areas and funding priorities were identified. First, a better understanding of viral communities in the built environment is needed, specifically which viruses are present and their sources, spatial and temporal dynamics, and interactions with bacteria. Second, more information is needed about viruses and health, including viral transmission in the built environment, the relationship between virus detection and exposure, and the definition of a healthy virome. The third research priority is to identify and evaluate interventions for controlling viruses and the virome in the built environment. This encompasses interactions among viruses, buildings, and occupants. Finally, to overcome the challenge of working with viruses, workshop participants emphasized that improved sampling methods, laboratory techniques, and bioinformatics approaches are needed to advance understanding of viruses in the built environment. CONCLUSIONS: We hope that identifying these key questions and knowledge gaps will engage other investigators and funding agencies to spur future research on the highly interdisciplinary topic of viruses in the built environment. There are numerous opportunities to advance knowledge, as many topics remain underexplored compared to our understanding of bacteria and fungi. Video abstract.
Assuntos
Ambiente Construído , Congressos como Assunto , Viroses/transmissão , Fenômenos Fisiológicos Virais , Vírus/isolamento & purificação , Biologia Computacional , Humanos , Metagenômica , Vírus/genéticaRESUMO
Highly transmissible influenza viruses (IV) must remain stable and infectious under a wide range of environmental conditions following release from the respiratory tract into the air. Understanding how expelled IV persist in the environment is critical to limiting the spread of these viruses. Little is known about how the stability of different IV in expelled aerosols is impacted by exposure to environmental stressors, such as relative humidity (RH). Given that not all IV are equally capable of efficient airborne transmission in people, we anticipated that not all IV would respond uniformly to ambient RH. Therefore, we have examined the stability of human-pathogenic seasonal and avian IV in suspended aerosols and stationary droplets under a range of RH conditions. H3N2 and influenza B virus (IBV) isolates are resistant to RH-dependent decay in aerosols in the presence of human airway surface liquid, but we observed strain-dependent variations in the longevities of H1N1, H3N2, and IBV in droplets. Surprisingly, low-pathogenicity avian influenza H6N1 and H9N2 viruses, which cause sporadic infections in humans but are unable to transmit person to person, demonstrated a trend toward increased sensitivity at midrange to high-range RH. Taken together, our observations suggest that the levels of vulnerability to decay at midrange RH differ with virus type and host origin.IMPORTANCE The rapid spread of influenza viruses (IV) from person to person during seasonal epidemics causes acute respiratory infections that can lead to hospitalizations and life-threatening illness. Atmospheric conditions such as relative humidity (RH) can impact the viability of IV released into the air. To understand how different IV are affected by their environment, we compared the levels of stability of human-pathogenic seasonal and avian IV under a range of RH conditions and found that highly transmissible seasonal IV were less sensitive to decay under midrange RH conditions in droplets. We observed that certain RH conditions can support the persistence of infectious viruses on surfaces and in the air for extended periods of time. Together, our findings will facilitate understanding of factors affecting the persistence and spread of IV in our environment.
Assuntos
Microbiologia Ambiental , Interações Hospedeiro-Patógeno , Viabilidade Microbiana , Orthomyxoviridae/fisiologia , Aerossóis , Animais , Aves , Humanos , Umidade , Vírus da Influenza A Subtipo H1N1/fisiologia , Vírus da Influenza A Subtipo H3N2/fisiologia , Vírus da Influenza A Subtipo H9N2/fisiologia , Influenza Aviária/virologia , Influenza Humana/transmissão , Influenza Humana/virologia , Orthomyxoviridae/classificação , TemperaturaRESUMO
BACKGROUND: Systemic lupus erythematosus, characterized by persistent inflammation, is a complex autoimmune disorder with no known cure. Immunosuppressants used in treatment put patients at a higher risk of infections. New knowledge of disease modulators, such as symbiotic bacteria, can enable fine-tuning of parts of the immune system, rather than suppressing it altogether. RESULTS: Dysbiosis of gut microbiota promotes autoimmune disorders that damage extraintestinal organs. Here we report a role of gut microbiota in the pathogenesis of renal dysfunction in lupus. Using a classical model of lupus nephritis, MRL/lpr, we found a marked depletion of Lactobacillales in the gut microbiota. Increasing Lactobacillales in the gut improved renal function of these mice and prolonged their survival. We used a mixture of 5 Lactobacillus strains (Lactobacillus oris, Lactobacillus rhamnosus, Lactobacillus reuteri, Lactobacillus johnsonii, and Lactobacillus gasseri), but L. reuteri and an uncultured Lactobacillus sp. accounted for most of the observed effects. Further studies revealed that MRL/lpr mice possessed a "leaky" gut, which was reversed by increased Lactobacillus colonization. Lactobacillus treatment contributed to an anti-inflammatory environment by decreasing IL-6 and increasing IL-10 production in the gut. In the circulation, Lactobacillus treatment increased IL-10 and decreased IgG2a that is considered to be a major immune deposit in the kidney of MRL/lpr mice. Inside the kidney, Lactobacillus treatment also skewed the Treg-Th17 balance towards a Treg phenotype. These beneficial effects were present in female and castrated male mice, but not in intact males, suggesting that the gut microbiota controls lupus nephritis in a sex hormone-dependent manner. CONCLUSIONS: This work demonstrates essential mechanisms on how changes of the gut microbiota regulate lupus-associated immune responses in mice. Future studies are warranted to determine if these results can be replicated in human subjects.