Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Malays J Med Sci ; 26(5): 132-138, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31728125

RESUMO

BACKGROUND: Endotracheal tube cuff (ETTc) inflation pressure is usually not regarded as an important aspect during intubation. In this study, we compared measuring ETTc pressure and pilot balloon palpation method in causing post-operative airway complications. METHODS: Two hundred and ninety-two surgical patients requiring intubation were recruited into this prospective, double-blind, randomised controlled study. Group A patients had their ETTc initially inflated, checked by a cuff pressure gauge, recorded and then set to 25 cmH2O. Group B patients had their ETTc inflated using the pilot balloon palpation method. Patients were then followed up for post-operative sore throat, hoarseness and cough. RESULTS: The overall incidence of post-operative sore throat was 39.0% versus 75.3% (P < 0.001), hoarseness 6.2% versus 15.1% (P < 0.05) and cough 7.5% versus 21.9% (P < 0.05) in Group A and B, respectively. Group A patients experienced a significant reduction in the incidence and severity of sore throat up to 24 h post-operatively (P < 0.001), hoarseness at the first hour (P = 0.004) and cough at first and 12 h post-operatively (P = 0.002). CONCLUSION: Adjusting the ETTc pressure to 25 cmH2O reduces post-operative sore throat, hoarseness and cough compared to pilot balloon palpation method.

3.
J Synchrotron Radiat ; 22(2): 458-60, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25723948

RESUMO

A method to pre-shape mirror substrates through etching with a broad-beam ion source and a contoured mask is presented. A 100 mm-long elliptical cylinder substrate was obtained from a super-polished flat Si substrate with a 48 nm root-mean-square (r.m.s.) figure error and a 1.5 Šr.m.s. roughness after one profile-etching process at a beam voltage of 600 V without iteration. A follow-up profile coating can be used to achieve a final mirror. Profile etching and profile coating combined provide an economic way to make X-ray optics, such as nested Kirkpatrick-Baez mirrors.

4.
Sensors (Basel) ; 14(7): 13046-69, 2014 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-25051031

RESUMO

This paper presents a comparison between the electroencephalogram (EEG) channels during scoliosis correction surgeries. Surgeons use many hand tools and electronic devices that directly affect the EEG channels. These noises do not affect the EEG channels uniformly. This research provides a complete system to find the least affected channel by the noise. The presented system consists of five stages: filtering, wavelet decomposing (Level 4), processing the signal bands using four different criteria (mean, energy, entropy and standard deviation), finding the useful channel according to the criteria's value and, finally, generating a combinational signal from Channels 1 and 2. Experimentally, two channels of EEG data were recorded from six patients who underwent scoliosis correction surgeries in the Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM) (the Medical center of National University of Malaysia). The combinational signal was tested by power spectral density, cross-correlation function and wavelet coherence. The experimental results show that the system-outputted EEG signals are neatly switched without any substantial changes in the consistency of EEG components. This paper provides an efficient procedure for analyzing EEG signals in order to avoid averaging the channels that lead to redistribution of the noise on both channels, reducing the dimensionality of the EEG features and preparing the best EEG stream for the classification and monitoring stage.


Assuntos
Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Escoliose/cirurgia , Adolescente , Encéfalo/cirurgia , Humanos , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Adulto Jovem
5.
Blood ; 117(25): 6866-75, 2011 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-21531978

RESUMO

The activating mutations in JAK2 (including JAK2V617F) that have been described in patients with myeloproliferative neoplasms (MPNs) are linked directly to MPN pathogenesis. We developed R723, an orally bioavailable small molecule that inhibits JAK2 activity in vitro by 50% at a concentration of 2nM, while having minimal effects on JAK3, TYK2, and JAK1 activity. R723 inhibited cytokine-independent CFU-E growth and constitutive activation of STAT5 in primary hematopoietic cells expressing JAK2V617F. In an anemia mouse model induced by phenylhydrazine, R723 inhibited erythropoiesis. In a leukemia mouse model using Ba/F3 cells expressing JAK2V617F, R723 treatment prolonged survival and decreased tumor burden. In V617F-transgenic mice that closely mimic human primary myelofibrosis, R723 treatment improved survival, hepatosplenomegaly, leukocytosis, and thrombocytosis. R723 preferentially targeted the JAK2-dependent pathway rather than the JAK1- and JAK3-dependent pathways in vivo, and its effects on T and B lymphocytes were mild compared with its effects on myeloid cells. Our preclinical data indicate that R723 has a favorable safety profile and the potential to become an efficacious treatment for patients with JAK2V617F-positive MPNs.


Assuntos
Antineoplásicos/uso terapêutico , Inibidores Enzimáticos/uso terapêutico , Janus Quinase 2/antagonistas & inibidores , Transtornos Mieloproliferativos/tratamento farmacológico , Transtornos Mieloproliferativos/genética , Anemia Hemolítica/induzido quimicamente , Animais , Linhagem Celular , Células Cultivadas , Eritropoese/efeitos dos fármacos , Feminino , Humanos , Janus Quinase 2/genética , Leucemia/tratamento farmacológico , Leucemia/genética , Leucocitose/tratamento farmacológico , Camundongos , Camundongos Endogâmicos BALB C , Camundongos SCID , Mutação/efeitos dos fármacos
6.
Front Oncol ; 13: 1095147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37564939

RESUMO

Sebaceous carcinoma (SC) is a rare malignant skin neoplasm derived from the meibomian gland of adnexal epithelium, which is frequently confused with basal cell carcinoma (BCC), exhibiting sebaceous differentiation and commonly found in the head and neck regions. We report a case of penile sebaceous carcinoma, an extremely rare anatomical site for SC. A 68-year-old man presented with a 4-month history of painless, non-healing ulcerated nodules over the left side of the penile shaft. Wedge biopsy showed adenocarcinoma with signet ring differentiation. We proceeded with wide local excision (WLE) of the lesion with the inclusion of the indurated skin and 5 mm of normal margin, followed by primary closure of the scrotal defect and split skin grafting of the penile shaft by using a thigh skin donor. The final histopathological examination revealed sebaceous carcinoma with pagetoid spread. The patient achieved recurrence-free survival without any form of adjuvant therapy after 4 years of follow-up.

7.
Sci Total Environ ; 867: 161471, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36634778

RESUMO

Satellite aerosol optical depth (AOD) provides an alternative way to depict the spatial distribution of near-surface PM2.5. In this study, a mathematical formulation of how PM2.5 is related to AOD is presented. When simplified to a linear equation, a functional dependence of the slope on the aerosol type, scattering enhancement factor f(RH), and boundary layer height is revealed, while the influence of the vertical aerosol profile is embedded in the intercept. Specifically, we focus on the effects of aerosol properties and employ a new aerosol index (Normalized Gradient Aerosol Index, NGAI) for classifying aerosol subtypes. The combination of AOD difference at shorter wavelengths over longer-wavelength AOD from AERONET data could distinguish and subclassify aerosol types previously indistinguishable by AE (i.e., urban-industrial pollution, U/I, and biomass burning, BB). AOD-PM2.5 regressions are performed on these aerosol subtypes at various relative humidity (RH) levels. The results suggest that BB aerosols are nearly hydrophobic until the RH exceeds 80 %, while the AOD-PM2.5 regressions for U/I depend on RH levels. Moreover, the scattering enhancement factor f(RH) can be calculated by taking the ratio of intercepts between dry and humidity conditions, which is proposed and tested for the first time in this study. Our results show an f(RH ≥ 80 %) of ∼2.6 for U/I-dominated aerosols, whereas the value is not over 1.5 for BB aerosols. The f(RH) can be further used to derive the optical hygroscopicity parameter (κsca), demonstrating that the NGAI can be used to exploit differences in aerosol hygroscopicity and improve the AOD-PM2.5 relationship.

8.
Diagnostics (Basel) ; 13(16)2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37627936

RESUMO

BACKGROUND: A feeding tube (FT) is routinely placed in critically ill patients, and its correct placement is confirmed with a chest X-ray (CXR), which is considered the gold standard. This study evaluated the diagnostic accuracy of ultrasonography (USG) in verifying FT placement compared to a CXR in an intensive care unit (ICU). METHOD: This was a prospective single-blind study conducted on patients admitted to the ICU of a tertiary hospital in Malaysia. The FT placements were verified through a fogging test and USG at the neck and subxiphoid points. The results of confirmation of FT placement through USG were compared with those obtained using CXRs. RESULTS: A total of 80 patients were included in this study. The FT positions were accurately confirmed by overall USG assessments in 71 patients. The percentage of FT placements correctly identified by neck USG was 97.5%, while the percentage of those identified by epigastric USG was 75%. The corresponding patients' CXRs confirmed correct FT placement in 76 patients. The overall USG assessment had a sensitivity of 92.11% and specificity of 75%, a positive predictive value of 98.59%, and a negative predictive value of 33.33%. The USG findings also showed a significant association between FT size and BMI. FTs with a size of 14Fr were better visualized (p = 0.008), and negative USG findings had a significantly higher BMI (p < 0.001). CONCLUSION: USG is a simple, safe, and reliable bedside assessment that offers relatively high sensitivity in confirming correct FT placement in critically ill patients.

9.
J Synchrotron Radiat ; 19(Pt 3): 425-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22514179

RESUMO

X-ray optics called multilayer Laue lenses (MLLs) provide a promising path to focusing hard X-rays with high focusing efficiency at a resolution between 5 nm and 20 nm. MLLs consist of thousands of depth-graded thin layers. The thickness of each layer obeys the linear zone plate law. X-ray beamline tests have been performed on magnetron sputter-deposited WSi(2)/Si MLLs at the Advanced Photon Source/Center for Nanoscale Materials 26-ID nanoprobe beamline. However, it is still very challenging to accurately grow each layer at the designed thickness during deposition; errors introduced during thickness measurements of thousands of layers lead to inaccurate MLL structures. Here, a new metrology approach that can accurately measure thickness by introducing regular marks on the cross section of thousands of layers using a focused ion beam is reported. This new measurement method is compared with a previous method. More accurate results are obtained using the new measurement approach.

10.
Cureus ; 14(3): e23176, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35308185

RESUMO

Introduction The advancement of supraglottic airways (SGAs) has eased airway management, especially for anesthetists. There were functional improvements implemented to the newer SGA. We aim to assess the clinical performance of laryngeal mask airway (LMA) Protector™ Cuff Pilot™ (Teleflex Inc., Wayne, Pennsylvania, USA) against LMA Supreme™ (Teleflex Inc., Wayne, Pennsylvania, USA), in terms of oropharyngeal leak pressure (OLP), successful insertion attempts, mean insertion time, ease of gastric tube insertion, laryngeal view, and incidence of sore throat among anesthetized, non-paralyzed patients undergoing general anesthesia. Methods In this prospective single-blinded study, 60 patients were randomized to use either LMA Protector™ Cuff Pilot™ or LMA Supreme™. Both groups received standard monitoring and induction regimes. Post-insertion, a bronchoscope was used to verify its position. A gastric tube was inserted and OLP was measured. Patients were assessed during the post-operative period for sore throats. Results LMA Protector™ Cuff Pilot™ was comparable to LMA Supreme™ in terms of mean OLP (30.72±8.60 vs 27.23±8.09 cmH2O, P = 0.114), first successful attempt (P = 0.312), mean insertion time (27.72±9.45 vs 24.37±6.46 seconds, P = 0.116), and grade 1 laryngeal view (51.7% vs 36.7%, P = 0.244). At first attempt, LMA Protector™ Cuff Pilot™ had a lower success rate of gastric tube insertion than LMA Supreme™ (55.17% vs 96.67%, P <0.001). The incidence of the blood-stained device and sore throat post-operatively were comparable between the two groups. Conclusion LMA Protector™ Cuff Pilot™ was comparable to LMA Supreme™ in terms of overall clinical performance, except for the first successful gastric tube insertion. Improvements should be made to the gastric channel for easier gastric tube insertion in the LMA Protector™ Cuff Pilot™.

11.
J Thorac Dis ; 14(11): 4246-4255, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36524091

RESUMO

Background: Molecular hydrogen, with its antioxidant and anti-inflammatory properties, may be suitable for the prevention and treatment of chronic obstructive pulmonary disease (COPD). This study aims to investigate the therapeutic efficacy of hydrogen-oxygen (H2/O2) treatment in cigarette smoke solution (CSS)-induced COPD-like injury in a female BALB/c mouse model. Methods: Thirty mice were randomly assigned to three groups: Control (n=8), COPD (n=10), and COPD + H2/O2 (n=12). CSS was administered by intraperitoneal (IP) injection twice weekly for 6 weeks during the COPD induction phase. Simultaneously, the COPD + H2/O2 group started received 75 minutes of inhalation therapy (42% H2) delivered by the Oxy-Hydrogen Generator twice daily for 9 weeks. Mice body weights and survival were measured throughout the study period. Neutrophil elastase (NE) activity and lung histopathological changes were also evaluated. Results: The results showed a higher survival rate in the COPD + H2/O2 group compared to the COPD group (100% vs. 80%) during the induction phase. Slight decreases in body weight gains were observed in the COPD and COPD + H2/O2 groups during the first 15 days of the induction phase, but there was no significant difference in mean body weights among the three groups throughout the study period. NE activity was numerically lower in the COPD + H2/O2 group compared to the COPD group. The histopathological evaluation showed significant improvements in the H2/O2-treated mice with respect to mean linear intercept (MLI) and lesion (inflammation and emphysema) scores. Improvements in goblet cell hypertrophy and hyperplasia of airway epithelium were not significant. Conclusions: A 9-week H2/O2 inhalation therapy delivered by the Oxy-Hydrogen Generator to CSS-induced COPD-like injury in mice showed improvement in survival rate, alveolar structural changes, and histopathological lesion scores of the lung.

12.
Front Med (Lausanne) ; 9: 979275, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36203774

RESUMO

Insertion of the laryngeal mask airway (LMA) without muscle relaxant requires adequate obtundation of airway reflexes, which may otherwise lead to incorrect or failed LMA placement. This study compared topical lignocaine spray vs. intravenous (IV) fentanyl, during propofol induction for insertion of the ProSeal™ LMA (PLMA). This was a prospective, randomized, double blind study, in ASA I or II patients, for elective or emergency surgery. Seventy patients (n = 70) who fulfilled the inclusion criteria were randomly assigned to receive IV fentanyl 2 mcg/kg or topical lignocaine spray 40 mg, prior to anesthesia induction with IV propofol (2-2.5 mg/kg). ProSeal™ LMA insertion condition was regarded optimal in the absence of adverse responses (gag, cough, laryngospasm and body movements), and successful LMA placement at the first attempt. Hemodynamic parameters were recorded and patients were assessed for sore throat and hoarseness post operatively. Seventy patients were analyzed. The number of patients with optimal PLMA insertion conditions were comparable between the groups (60% vs. 57%, P = 0.808). All hemodynamic parameters were comparable between groups with the exception of heart rate. Sympathetic obtundation of heart rate was greater with IV fentanyl than topical lignocaine (P < 0.05). The proportion of patients with postoperative sore throat significantly increased with the number of insertion attempts (P < 0.05). Topical lignocaine spray to the pharynx is as effective, and may be an alternative to IV fentanyl, during propofol induction for PLMA insertion. Success rate and optimal insertion condition at the first attempt, propofol requirement, blood pressure, adverse events and airway complications were comparable. Heart rate obtundation was less with topical lignocaine spray but remained within clinically acceptable values.

13.
J Hand Surg Glob Online ; 4(6): 414-420, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36425368

RESUMO

Purpose: Excision of wrist ganglions is a common procedure in hand surgery. Our objective was to determine whether the type of anesthesia (general anesthesia [GA] vs wide-awake local anesthesia no tourniquet [WALANT] technique) would affect patient satisfaction regarding intraoperative pain control, postoperative pain management, and anxiety. Methods: This was a prospective study with patients divided into either the WALANT or GA cohort. The waiting time for surgery, Amsterdam Preoperative Anxiety and Information Scale, blood pressure, and heart rate were measured. Postsurgical questionnaires with the visual analog scale were completed. The surgeon's feedback on the ease of ganglion stalk visibility and usage of diathermy as a measure of a bloodless field was recorded. Patients reported the amount of analgesia consumed and overall satisfaction with the operation via the Surgical Satisfaction-8 questionnaire. Results: A total of 42 patients underwent wrist ganglion excision in 2 orthopedic centers over a period of 2 years, with 21 undergoing GA and 22 undergoing WALANT. The GA group was more anxious about anesthetic use with a higher demand for information about GA (P = .04). The duration of surgery was significantly shorter in the WALANT group and with a lower diathermy usage (P < .001). There was no difference in terms of surgical difficulty and stalk visualization. The visual analog scale pain score was significantly lower in the WALANT group than in the GA group immediately after surgery (P = .04) and on discharge (P = .004). While at home for 2 weeks, the WALANT group (mean = 2.91 tablets) consumed significantly fewer analgesic tablets than the GA group (mean = 6.25 tablets). However, both groups were satisfied with their experience. Conclusions: Wide-awake local anesthesia no tourniquet technique in the excision of ganglions provides another option of anesthesia with painless experiences, and no pain rebound after surgery. Patients were less anxious about WALANT than GA. Excision can be performed without diathermy usage with similar visualization of the stalk. Type of study/level of evidence: Therapeutic II.

14.
Artigo em Inglês | MEDLINE | ID: mdl-35270494

RESUMO

Depression is ranked as the second-leading cause for years lived with disability worldwide. Objective monitoring with a standardized scale for depressive symptoms can improve treatment outcomes. This study evaluates the construct and concurrent validity of the Malay Self-Report Quick Inventory of Depressive Symptomatology (QIDS-SR16) among Malaysian clinical and community samples. This cross-sectional study was based on 277 participants, i.e., patients with current major depressive episode (MDE), n = 104, and participants without current MDE, n = 173. Participants answered the Malay QIDS-SR16 and were administered the validated Malay Mini-International Neuropsychiatric Interview (MINI) for DSM-IV-TR. Factor analysis was used to determine construct validity, alpha statistic for internal consistency, and receiver operating characteristic (ROC) analysis for concurrent validity with MINI to determine the optimal threshold to identify MDE. Data analysis provided evidence for the unidimensionality of the Malay QIDS-SR16 with good internal consistency (Cronbach's α = 0.88). Based on ROC analysis, the questionnaire demonstrated good validity with a robust area under the curve of 0.916 (p < 0.000, 95% CI 0.884−0.948). A cut-off score of nine provided the best balance between sensitivity (88.5%) and specificity (83.2%). The Malay QIDS-SR16 is a reliable and valid instrument for identifying MDE in unipolar or bipolar depression.


Assuntos
Transtorno Depressivo Maior , Estudos Transversais , Transtorno Depressivo Maior/diagnóstico , Humanos , Malásia , Escalas de Graduação Psiquiátrica , Psicometria , Reprodutibilidade dos Testes , Autorrelato
15.
J Synchrotron Radiat ; 18(Pt 4): 575-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21685674

RESUMO

The first test of nanoscale-focusing Kirkpatrick-Baez (KB) mirrors in the nested (or Montel) configuration used at a hard X-ray synchrotron beamline is reported. The two mirrors are both 40 mm long and coated with Pt to produce a focal length of 60 mm at 3 mrad incident angle, and collect up to a 120 µm by 120 µm incident X-ray beam with maximum angular acceptance of 2 mrad and a broad bandwidth of energies up to 30 keV. In an initial test a focal spot of about 150 nm in both horizontal and vertical directions was achieved with either polychromatic or monochromatic beam. The nested mirror geometry, with two mirrors mounted side-by-side and perpendicular to each other, is significantly more compact and provides higher demagnification than the traditional sequential KB mirror arrangement. Ultimately, nested mirrors can focus larger divergence to improve the diffraction limit of achromatic optics. A major challenge with the fabrication of the required mirrors is the need for near-perfect mirror surfaces near the edge of at least one of the mirrors. Special polishing procedures and surface profile coating were used to preserve the mirror surface quality at the reflecting edge. Further developments aimed at achieving diffraction-limited focusing below 50 nm are underway.

16.
Opt Express ; 19(16): 15069-76, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21934868

RESUMO

Hard x-ray microscopy with nanometer resolution will open frontiers in the study of materials and devices, environmental sciences, and life sciences by utilizing the unique characterization capabilities of x-rays. Here we report two-dimensional nanofocusing by multilayer Laue lenses (MLLs), a type of diffractive optics that is in principle capable of focusing x-rays to 1 nm. We demonstrate focusing to a 25 × 27 nm(2) FWHM spot with an efficiency of 2% at a photon energy of 12 keV, and to a 25 × 40 nm(2) FWHM spot with an efficiency of 17% at a photon energy of 19.5 keV.


Assuntos
Microscopia/métodos , Nanotecnologia/métodos , Animais , Desenho de Equipamento , Humanos , Lentes , Microscopia Eletrônica de Varredura/métodos , Microscopia de Fluorescência/métodos , Óptica e Fotônica/métodos , Fótons , Raios X
17.
Cureus ; 13(1): e12876, 2021 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-33633905

RESUMO

INTRODUCTION: Distal end radius fractures are common fractures commonly treated with an option of open reduction and plating. Traditionally, plating is performed under general anesthesia (GA) or regional block. Recently, a new technique of plating under wide-awake local anesthesia with no tourniquet (WALANT) has been introduced. We aim to compare the preoperative anxiety level, intraoperative pain scores, post-operative pain scores, operating time, blood loss and clinical outcome of distal end radius plating with WALANT versus GA with tourniquet. METHODS: We conducted a randomized controlled study on patients with closed fracture of the distal end of the radius requiring open reduction and plating from January 2019 till April 2020. We recruited 65 patients (33 patients in the WALANT group and 32 patients in the GA group). Randomization was done via block randomization. Data were collected to evaluate preoperative anxiety using the Amsterdam Preoperative Anxiety and Information Scale (APAIS) score, intraoperative pain score during injection (baseline) (V1), 10 minutes after injection (V2), during incision (V3), during gentle manipulation (V4), during aggressive manipulation (V5) and during first drilling of screw (V6), blood loss, duration of surgery and post-operative pain score. Additionally, intraoperative visual analog scale (VAS) score was obtained in the WALANT group. At three weeks, six weeks, three months and six months after operation, the Quick Disabilities of Arm, Shoulder and Hand (QuickDASH) scores and range of motion (ROM) of the wrists were obtained. RESULTS: The average age in the WALANT group was 47.19 (range, 36-64) years and GA group was 49.48 (range, 38-60) years. The mean APAIS score obtained was 7.78 (WALANT group) and 7.36 (GA group) with no statistical difference. For intraoperative VAS, only during V4 and V5 were the scores 1/10; otherwise at all other phases, the VAS score was 0. The average time for surgery was statistically longer in the WALANT group (61.22 minutes) compared to the GA group (55.33 minutes) (p = 0.003). There was no statistical difference in mean blood loss in both groups. The average post-operative VAS showed statistical significance only at 1 hour and 12 hours post-operation with no statistical difference at 2 and 24 hours post-operation. There was no difference in the post-operative ROM including wrist flexion, extension, supination and pronation for both groups up to six months' follow-up. CONCLUSION: There was no statistically significant difference in terms of preoperative anxiety level, intraoperative and post-operative VAS score, amount of blood loss and clinical outcome in both groups for plating of the distal end radius. However, the operating time was slightly longer in the WALANT group. We conclude that distal radius plating under WALANT has similar outcomes to GA. In centres with limited resources, WALANT offers a safe, reliable and cheaper option, reserving GA time for head, abdominal and thoracic surgery.

18.
Opt Express ; 18(22): 23420-7, 2010 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-21164684

RESUMO

We have used coherent X-ray diffraction experiments to characterize both the 1-D and 2-D foci produced by nanofocusing Kirkpatrick-Baez (K-B) mirrors, and we find agreement. Algorithms related to ptychography were used to obtain a 3-D reconstruction of a focused hard X-ray beam waist, using data measured when the mirrors were not optimally aligned. Considerable astigmatism was evident in the reconstructed complex wavefield. Comparing the reconstructed wavefield for a single mirror with a geometrical projection of the wavefront errors expected from optical metrology data allowed us to diagnose a 40 µrad misalignment in the incident angle of the first mirror, which had occurred during the experiment. Good agreement between the reconstructed wavefront obtained from the X-ray data and off-line metrology data obtained with visible light demonstrates the usefulness of the technique as a metrology and alignment tool for nanofocusing X-ray optics.

19.
Opt Express ; 18(24): 24975-82, 2010 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-21164842

RESUMO

We demonstrated the Talbot effect using a broadband hard x-ray beam (Δλ/λ ~1). The exit wave-field of the x-ray beam passing through a grating with a sub micro-meter scale period was successfully replicated and recorded at effective Talbot distance, Z(T). The period was reduced to half at Z(T)/4 and 3/4Z(T), and the phase reversal was observed at Z(T)/2. The propagating wave-field recorded on photoresists was consistent with a simulated result.

20.
Rev Sci Instrum ; 79(5): 053104, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18513058

RESUMO

A multilayer Laue lens (MLL) is an x-ray focusing optic fabricated from a multilayer structure consisting of thousands of layers of two different materials produced by thin-film deposition. The sequence of layer thicknesses is controlled to satisfy the Fresnel zone plate law and the multilayer is sectioned to form the optic. An improved MLL geometry can be created by growing each layer with an in-plane thickness gradient to form a wedge, so that every interface makes the correct angle with the incident beam for symmetric Bragg diffraction. The ultimate hard x-ray focusing performance of a wedged MLL has been predicted to be significantly better than that of a nonwedged MLL, giving subnanometer resolution with high efficiency. Here, we describe a method to deposit the multilayer structure needed for an ideal wedged MLL and report our initial deposition results to produce these structures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA