Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
AJR Am J Roentgenol ; 220(4): 524-538, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36321987

RESUMO

BACKGROUND. Prior small single-center studies have yielded conflicting results regarding the prognostic significance of myocardial strain parameters derived from feature tracking (FT) on cardiac MRI in patients with dilated cardiomyopathy (DCM). OBJECTIVE. The purpose of this study was to evaluate the prognostic utility of FT parameters on cardiac MRI in patients with ischemic and nonischemic DCM and to determine the optimal strain parameter for outcome prediction. METHODS. This retrospective study included 471 patients (median age, 61 years; 365 men, 106 women) with ischemic (n = 233) or nonischemic (n = 238) DCM and left ventricular (LV) ejection fraction (EF) less than 50% who underwent cardiac MRI at any of four centers from January 2011 to December 2019. Cardiac MRI parameters were determined by manual contouring. In addition, software-based FT was used to calculate six myocardial strain parameters (LV and right ventricular [RV] global radial strain, global circumferential strain, and global longitudinal strain [GLS]). Late gadolinium enhancement (LGE) was also evaluated. Patients were assessed for a composite outcome of all-cause mortality and/or heart-failure hospitalization. Cox regression models were used to determine associations between strain parameters and the composite outcome. RESULTS. Mean LV EF was 27.5% and mean LV GLS was -6.9%. The median follow-up period was 1328 days. The composite outcome occurred in 220 patients (125 deaths, 95 heart-failure hospitalizations). All six myocardial strain parameters were significant independent predictors of the composite outcome (hazard ratio [HR] = 0.92-1.16; all p < .05). In multivariable models that included age, corrected LV and RV end-diastolic volume, LV and RV EF, and presence of LGE, the only strain parameter that was a significant independent predictor of the composite outcome was LV GLS (HR = 1.13, p = .006); LV EF and presence of LGE were not independent predictors of the composite outcome in the models (p > .05). A LV GLS threshold of -6.8% had sensitivity of 62.6% and specificity of 62.6% in predicting the composite outcome rate at 4.0 years. CONCLUSION. LV GLS, derived from FT on cardiac MRI, is a significant independent predictor of adverse outcomes in patients with DCM. CLINICAL IMPACT. This study strengthens the body of evidence supporting the clinical implementation of FT when performing cardiac MRI in patients with DCM.


Assuntos
Cardiomiopatia Dilatada , Insuficiência Cardíaca , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/complicações , Prognóstico , Estudos Retrospectivos , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/efeitos adversos , Volume Sistólico , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes
2.
Acta Neurochir (Wien) ; 161(8): 1623-1632, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31222516

RESUMO

BACKGROUND: External ventricular drainage (EVD) is the commonest neurosurgical procedure performed in daily neurosurgical practice, but relatively few studies have investigated the incidence and risk factors of its related hemorrhagic complications. METHODS: This was a multicenter retrospective review of consecutive EVD procedures. Patients 18 years or older who underwent EVD and had a routine postoperative computed tomography (CT) scan performed within 24 hours were included. EVD-related hemorrhage was defined as new intracranial hemorrhage immediately adjacent or within the ventricular catheter trajectory. The volume of hemorrhage and the position of the catheter tip were assessed. A review of patient-, disease-, and surgery-related factors including the ventricular catheter design utilized was conducted. The Bonferroni correction was applied to the alpha level of significance (0.05) for multivariable analysis. RESULTS: Nine hundred sixty-two patients underwent 1002 EVD performed by neurosurgeons in the operating theater. Sixteen percent (154) of patients were on aspirin before the procedure. Thirty-four percent (333) of patients had intracerebral hemorrhage, 25% (251) had aneurysmal subarachnoid hemorrhage and 16% (158) had traumatic brain injury. The mean duration from EVD to the first postoperative CT scan was 20 ± 4 h. EVD-related hematomas were detected after 81 procedures with a per-catheter risk of 8.1%. Mean hematoma volume was 1.2 ± 3.3 ml. Most were less than 1 ml (grade I, 79%, 64), 1 to 15 ml (grade II) in 20% (16) and a single clot larger than 15 ml (grade III, 1%) were detected. Clinically significant hemorrhage that resulted in catheter occlusion occurred in 1.7% (17) of procedures. Most catheters (62%, 625) were optimally placed, i.e., its tip being within the ipsilateral frontal horn or third ventricle. Three non-antibiotic-impregnated ventricular catheter designs were used with 55% (550) being the 2.2-mm Integra™ catheter, 14% (137) being the 2.8-mm Medtronic™ catheter, and 31% (315) being the 3.1-mm Codman™ catheter. Independent significant predictors for EVD-related hemorrhage were the preoperative prescription of aspirin (adjusted OR 1.94; 95% CI 1.10-3.44), catheter malposition (aOR 1.99; 95% CI 1.22-3.23), and use of the 2.8-mm Medtronic™ catheter (aOR 4.22; 95% CI 2.39-7.41). CONCLUSIONS: The per-catheter risk of hemorrhage was 8.1%, but the incidence of symptomatic hemorrhage was low. The only patient risk factor was aspirin intake. This is the first study to evaluate and establish an association between catheter malposition and catheter design with EVD-related hemorrhage.


Assuntos
Aspirina/efeitos adversos , Cateterismo/métodos , Catéteres/efeitos adversos , Drenagem/métodos , Hemorragias Intracranianas/etiologia , Procedimentos Neurocirúrgicos/métodos , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Aspirina/administração & dosagem , Cateterismo/efeitos adversos , Cateterismo/instrumentação , Catéteres/normas , Drenagem/efeitos adversos , Drenagem/instrumentação , Feminino , Humanos , Hemorragias Intracranianas/epidemiologia , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/instrumentação , Complicações Pós-Operatórias/epidemiologia , Terceiro Ventrículo/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA