RESUMO
Small molecule therapeutics represent the majority of the FDA-approved drugs. Yet, many attractive targets are poorly tractable by small molecules, generating a need for new therapeutic modalities. Due to their biocompatibility profile and structural versatility, peptide-based therapeutics are a possible solution. Additionally, in the past two decades, advances in peptide design, delivery, formulation, and devices have occurred, making therapeutic peptides an attractive modality. However, peptide manufacturing is often limited to solid-phase peptide synthesis (SPPS), liquid phase peptide synthesis (LPPS), and to a lesser extent hybrid SPPS/LPPS, with SPPS emerging as a predominant platform technology for peptide synthesis. SPPS involves the use of excess solvents and reagents which negatively impact the environment, thus highlighting the need for newer technologies to reduce the environmental footprint. Herein, fourteen American Chemical Society Green Chemistry Institute Pharmaceutical Roundtable (ACS GCIPR) member companies with peptide-based therapeutics in their portfolio have compiled Process Mass Intensity (PMI) metrics to help inform the sustainability efforts in peptide synthesis. This includes PMI assessment on 40 synthetic peptide processes at various development stages in pharma, classified according to the development phase. This is the most comprehensive assessment of synthetic peptide environmental metrics to date. The synthetic peptide manufacturing process was divided into stages (synthesis, purification, isolation) to determine their respective PMI. On average, solid-phase peptide synthesis (SPPS) (PMI ≈ 13,000) does not compare favorably with other modalities such as small molecules (PMI median 168-308) and biopharmaceuticals (PMI ≈ 8300). Thus, the high PMI for peptide synthesis warrants more environmentally friendly processes in peptide manufacturing.
Assuntos
Peptídeos , Técnicas de Síntese em Fase Sólida , Peptídeos/química , Técnicas de Química Sintética , SolventesRESUMO
BACKGROUND: Acute myocardial infarction complicated by cardiogenic shock (AMI-CS) is the most common cause of mortality following AMI, and treatment algorithms vary widely. We report the results of an analysis using time-sensitive, hemodynamic goals in the treatment of AMI-CS in a single center study. METHODS: Consecutive patients with AMI-CS from November 2016 through December 2021 were included in our retrospective analysis. Clinical characteristics and outcomes were analyzed using the electronic medical records. We identified 63 total patients who were admitted to our center with AMI-CS, and we excluded patients who did not have clear timing of AMI onset or CS onset. We evaluated the rate of survival to hospital discharge based on the quantity of certain time-sensitive hemodynamic goals were met. RESULTS: We identified 63 patients who met criteria for AMI-CS, 39 (62%) of whom survived to hospital discharge. Odds of survival were closely related to the achievement of four time-dependent goals: cardiac power output (CPO) >0.6 Watts (W), pulmonary artery pulsatility index (PAPi) >1, lactate <4 mmol/L, and <2 vasopressors required. Of the 63 total patients, 36 (57%) received intra-aortic balloon pump (IABP) and 18 (29%) received an Impella CP (Abiomed) as an initial mechanical circulatory support strategy. Six patients were escalated from IABP to Impella CP for additional hemodynamic support. Nine patients were treated with vasopressors/inotropes alone. Regarding the 39 patients who survived to hospital discharge, 75% of patients met 3 or 4 goals at 24 h, whereas only 16% of deceased patients met 3 or 4 goals at 24 h. Of the 24 patients who did not survive to hospital discharge, 18 (75%) met either 0-1 goal at 24 h. There was no effect of the initial treatment strategy on achieving 3-4 goals at 24 h. CONCLUSION: Our study evaluated the association of meeting 4 time-sensitive goals (CPO >0.6 W, PAPi >1, <2 vasopressors, and lactate <4 mmol/L) at 24 h after treatment for AMI-CS with in-hospital mortality. Our data show, in line with previous data, that the higher number of goals met at 24 h was associated with improved in-hospital mortality regardless of treatment strategy.
Assuntos
Coração Auxiliar , Infarto do Miocárdio , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Estudos Retrospectivos , Objetivos , Resultado do Tratamento , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Hemodinâmica , Balão Intra-Aórtico/efeitos adversos , Coração Auxiliar/efeitos adversos , LactatosRESUMO
We report for the first time to our knowledge on top-down percussion drilling of high-quality deep holes in different glasses with femtosecond laser pulses in GHz-burst mode. We reveal the dynamics of the percussion drilling process by pump-probe shadowgraphy and thermal camera imaging demonstrating that the drilling process in GHz-burst mode is fundamentally different from single-pulse processing and confirming the presence of thermal accumulation. Moreover, we show a comparison to drilling by femtosecond single-pulses containing an equal laser fluence in sodalime, alkali-free alumina-borosilicate, fused silica, and sapphire.
RESUMO
BACKGROUND: Before the development of transcatheter aortic valve replacement (TAVR), balloon aortic valvuloplasty (BAV) was the only potential nonsurgical intervention for patients with aortic stenosis complicated by cardiogenic shock. Emergent TAVR is now an option and has shown acceptable outcomes compared with elective TAVR. We explored how treatment patterns for aortic stenosis and cardiogenic shock among patients received invasive intervention have shifted since TAVR was introduced. METHODS: We used the Nationwide In patients Sample to identify nonelective hospitalizations for patient with aortic stenosis complicated by cardiogenic shock who received invasive treatment (TAVR, BAV, or surgical aortic valve replacement [SAVR]). We explored the proportion treated with each treatment modality over time, the patient characteristics and in-hospital mortality associated with each treatment, and used multivariable logistic regression to examine whether changes in in-hospital mortality over time differed by treatment. RESULTS: Between 2010 and 2019, we identified 9899 hospitalizations for decompensated aortic stenosis with cardiogenic shock during which patients received invasive treatment (TAVR 17.7%, BAV 20.2%, SAVR 62.1%). Use of both TAVR and BAV has increased over time compared with SAVR (TAVR 6.6% ≥ 33.8%, BAV 8.4% ≥ 23.2%, SAVR 91.6% ≥ 43.0%; p < 0.001 for trend). The overall in-hospital mortality rate was 21.0%, which decreased over time for all treatments (TAVR 20.0% ≥ 18.8%, BAV 66.0% ≥ 25.5%, SAVR 17.7% ≥ 11.8%; linear trend p < 0.001 for each), with lower mortality for TAVR versus BAV at all time points. Patients treated with TAVR (vs. BAV) were less likely to require mechanical ventilation (36.8% vs. 46.3%, p < 0.001) or mechanical circulatory support (22.5% vs. 29.9%, p < 0.001). In the multivariable analysis, the interaction between treatment and time was not significant (p = 0.245), indicating the reduction in in-hospital mortality over time did not differ among the treatments. CONCLUSIONS: Since the introduction of TAVR, there has been a shift toward increased use of nonsurgical invasive treatments (both BAV and TAVR) for aortic stenosis and cardiogenic shock. Although in-hospital mortality has declined, it remains high in all groups, but particularly among patients treated with BAV, where the severity of cardiogenic shock appears to be higher than in those treated with other modalities.
Assuntos
Estenose da Valva Aórtica , Choque Cardiogênico , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , HospitalizaçãoRESUMO
BACKGROUND: Optical coherence tomography (OCT) is an intravascular imaging modality for analysing coronary vessels. Image interpretation remains an obstacle for novice readers due to technical artefacts and uncertainty in tissue characterization. Despite an expanding clinical and research role for OCT, few training efforts exist, and there is an absence of a national standardized educational curriculum. We sought to determine whether an interactive, feedback-based OCT curriculum improved image interpretation among naive readers. METHODS: Naive OCT readers completed both a Standard curriculum, comprised of self-directed didactics and consensus statements, and an Augmented curriculum, which provided real-time digital feedback of feature identification and measurements. Modules were separated by a minimum one-week washout period. After each module, and blinded to the exam answers, subjects completed an identical expert-designed 413-item exam to assess technical knowledge and ability to identify and measure vessel features. Performances were compared using Exact Wilcoxon signed-rank tests. RESULTS: Among the 7 included subjects were 3 medical students, 3 internal medicine residents, and 1 cardiovascular medicine fellow with no prior OCT experience. The technical knowledge score (maximum 13) was significantly higher with the Augmented compared with the Standard curriculum (median 11 vs. 7, p = 0.03). After undergoing the Augmented curriculum, all 7 subjects were able to identify features of plaque rupture (Standard curriculum: 5/7 subjects, p = 0.5) and macrophages (Standard curriculum: 6/7 subjects, p = 0.99), differentiate the components between red and white thrombus (Standard curriculum: 6/7 subjects, p = 0.99), and characterize lipid plaque by attenuation, signal, homogeneity, and borders (Standard curriculum: 5/7 subjects, p = 0.5). Performances on the remaining exam portions did not differ between curricula. CONCLUSIONS: The need for standardized, effective training in OCT image interpretation is increasingly essential as the intravascular imaging modality becomes widely utilized among interventional cardiologists and trainees. A novel interactive OCT curriculum enhanced naive readers' technical knowledge and may supplement traditional self-learning in refining analytic skills.
Assuntos
Doença da Artéria Coronariana , Tomografia de Coerência Óptica , Currículo , Humanos , Lipídeos , Tomografia de Coerência Óptica/métodosRESUMO
BACKGROUND: Activation maps of scar-related atrial tachycardias (AT) can be challenging to interpret due to difficulty in inaccurate annotation of electrograms, and an arbitrarily predefined mapping window. A novel mapping software integrating vector data and applying an algorithmic solution taking into consideration global activation pattern has been recently described (Coherent™, Biosense Webster "Investigational"). OBJECTIVE: We aimed to assess the investigational algorithm to determine the mechanism of AT compared with the standard algorithm. METHODS: This study included patients who underwent ablation of scar-related AT using the Carto 3 and the standard activation algorithm. The mapping data were analyzed retrospectively using the investigational algorithm, and the mechanisms were evaluated by two independent electrophysiologists. RESULTS: A total of 77 scar-related AT activation maps were analyzed (89.6% left atrium, median tachycardia cycle length of 273 ms). Of those, 67 cases with a confirmed mechanism of arrhythmia were used to compare the activation software. The actual mechanism of the arrhythmia was more likely to be identified with the investigational algorithm (67.2% vs. 44.8%, p = .009). In five patients with dual-loop circuits, 3/5 (60%) were correctly identified by the investigational algorithm compared to 0/5 (0%) with the standard software. The reduced atrial voltage was prone to lead to less capable identification of mechanism (p for trend: .05). The investigational algorithm showed higher inter-reviewer agreement (Cohen's kappa .62 vs. .47). CONCLUSIONS: In patients with scar-related ATs, activation mapping algorithms integrating vector data and "best-fit" propagation solution may help in identifying the mechanism and the successful site of termination.
Assuntos
Ablação por Cateter , Cicatriz , Algoritmos , Cicatriz/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Humanos , Estudos Prospectivos , Estudos Retrospectivos , TaquicardiaRESUMO
The coronavirus pandemic has resulted in the need for rapid assessment of resource utilization within our hospital systems. Specifically, the overwhelming need for intensive care unit (ICU) beds within epicenters of the pandemic has created a need for consideration as to how acute coronary syndrome cases, and specifically ST-elevation myocardial infarction (STEMI) patients, are managed postprocedure. While most patients in the United States continue to be managed in coronary care units after primary percutaneous coronary intervention, there is a robust literature regarding the ability to triage STEMI patients safely and efficiently with low-risk features to non-ICU beds. We review the various risk scores for STEMI triage and the data supporting their usage. In summary, these findings support an approach to low-risk STEMI triage that does not come at the expense of quality patient care or outcomes, where up to two-thirds of patients with STEMI may be able to be safely managed without ICU-level care.
Assuntos
COVID-19/epidemiologia , Pandemias , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Triagem/métodos , Comorbidade , Humanos , Fatores de Risco , SARS-CoV-2 , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologiaRESUMO
Glass processing is a subject of high interest for many industrial fields such as optics manufacturing, smart electronics or medical devices. With respect to nanosecond technology, the use of femtosecond lasers allows to achieve high processing quality thanks to nonlinear absorption properties. Nevertheless, the throughput of femtosecond processing is still very low when compared to other laser technologies. Temporal and spatial pulse shaping is a smart and flexible solution to further increase the efficiency of femtosecond laser processing by driving efficiently both electron dynamics and absorption involved during laser irradiation. In the present work, the effect of temporal pulse shaping on fused silica ablation is investigated by single-wavelength (1030nm) double femtosecond pulses pump-pump experiment. Two sub-pulses are focused on the top surface of fused silica with two different polarization configurations: (i) orthogonally-crossed linear polarization or (ii) counter-rotating circular polarization. The investigated parameters are the pulse-to-pulse delay, set with a delay line, the total fluence and the polarization configuration. The results are discussed in term of optical transmission, modification and ablation thresholds, and ablated volume. A numerical model describing the electron dynamics and the absorbed energy density is also presented to support interpretation of experimental results. It is demonstrated that pulse-to-pulse delay has a major influence on ablated volume, modification and ablation threshold. Polarization state has also, to a lesser extent, a significant influence on ablated volume. Their cooperative effect on the ablation efficiency is discussed.
RESUMO
We report on crater formation, line scribing and cavity milling experiments on Silicon, Copper, Aluminum and stainless steel with GHz bursts of femtosecond pulses. The intra-burst repetition rate has been varied between 0.88 and 3.52â GHz, the number of pulses per burst between 50 and 3200, the burst fluence between 8 and 80â J/cm2. For these experiments, a 100-W femtosecond GHz-burst laser has been developed on an industrial laser basis, delivering a total burst energy up to 1 mJ at 100 kHz, with an adjustable number of pulses per burst. The results highlight the conditions to obtain high-ablation efficiency, show how to optimize the machining quality and point out the burst duration as the relevant parameter for femtosecond GHz machining.
RESUMO
INTRODUCTION: Anomalous origin of coronary arteries has been observed in about 0.35-2.10% of the population. Patients with anomalous right coronary artery (ARCA) may present with significant symptoms, arrhythmias or ACS, and at times sudden death. Traditionally, surgical correction has been the recommended treatment. However, these may be technically challenging, and bypass grafting for such anomalies has the potential for graft failure because of competitive flow. We sought to determine the intermediate and long-term outcomes of drug-eluting stent placement for patients with symptomatic ARCA. We also looked at angiographic findings suggestive of interarterial course as confirmed by subsequent computed tomography (CT) findings. METHODS: Between January 2005 and December 2012, we enrolled 11 patients for elective percutaneous coronary intervention (PCI) of ARCA in a single center, prospective, nonrandomized fashion. Patients were followed up in clinic at 1 week, 3 months, 6 months, and 1 year, and then annually or more frequently if needed. All patients underwent a cardiac CT, as well as functional stress testing when needed to assess for recurrence of disease. RESULTS: All 11 of our patients, who presented with significant symptomatic stenosis with an ARCA, were successfully treated with PCI. Mean follow-up duration was 8.5 years. The only two deaths during follow-up were related to noncardiac causes (sepsis), with a mortality rate of 18.2%. Two patients had a positive functional study and on subsequent coronary angiography, one of them had significant in-stent restenosis (target lesion revascularization of 9.1%) and one distal to the stent (target vessel revascularization 9.1%). We found the observation of a "slit-like lesion" on angiography to have a sensitivity of 100% and specificity of 86% for the diagnosis of interarterial course of the anomalous vessel seen on subsequent CT. CONCLUSIONS: Our study results suggest that PCI of ARCA is an effective and low-risk alternative to surgical correction, with good procedural success and long-term outcomes. It can provide symptomatic relief in such patients and may reduce the risk of sudden death in younger patients, without the inherent risks associated with surgical repair.
Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária/terapia , Anomalias dos Vasos Coronários/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Estenose Coronária/fisiopatologia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/mortalidade , Anomalias dos Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
A subset of high-risk pulmonary embolism (PE) patients requires advanced therapy beyond anticoagulation. Significant variation in delivery of care has led institutions to standardize their approach by developing Pulmonary Embolism Response Team (PERT). We sought to assess the impact of PERT implementation on house staff and faculty education. After implementation of PERT, we employed a targeted educational intervention aimed to improve PERT awareness, familiarity with treatment options, role of echocardiogram and Doppler ultrasound, and knowledge of acute PE risk stratification tools. We conducted an anonymous survey among the house staff and faculty before and after intervention to assess the impact of PERT implementation on educational objectives among clinicians. Initial and follow up samples included 115 and 109 responses. The samples were well represented across the subspecialties and all levels of training, as well as junior and senior faculty. Following the educational campaign, awareness of the program increased (72.2-92.6%, p < 0.01). Proportion of clinicians with reported comfort level of managing PE increased (82.4-90.8%, p = 0.07). Proportion of clinicians with self-reported comfort with explaining all available treatment modalities to patients increased (49.1-67.9%, p = 0.005). Proportions of responders who correctly identified the role of echocardiography in risk stratification of patients with known PE increased (73.9-84.4%, p = 0.07). Accurate clinical risk stratification of acute PE increased (60.2-73.8%, p = 0.03). The implementation of a targeted educational program at a tertiary care center increased awareness of PERT among house staff and faculty and improved physician's accuracy of clinical risk stratification and comfort level with management of acute PE.
Assuntos
Educação Médica Continuada , Docentes de Medicina , Internato e Residência , Equipe de Assistência ao Paciente , Embolia Pulmonar/terapia , Feminino , Humanos , MasculinoRESUMO
The protection of side-chain arginine in solid-phase peptide synthesis requires attention since current protecting groups have several drawbacks. Herein, the NO2 group, which is scarcely used, has been revisited. This work shows that it prevents the formation of δ-lactam, the most severe side-reaction during the incorporation of Arg. Moreover, it is stable in solution for long periods and can be removed in an easy-to-understand manner. Thus, this protecting group can be removed while the protected peptide is still anchored to the resin, with SnCl2 as reducing agent in mild acid conditions using 2-MeTHF as solvent at 55 °C. Furthermore, we demonstrate that sonochemistry can facilitate the removal of NO2 from multiple Arg-containing peptides.
Assuntos
Aminoácidos/química , Arginina/química , Dióxido de Nitrogênio/química , Peptídeos/síntese química , Técnicas de Síntese em Fase Sólida/métodosRESUMO
We report on silicon ablation with a 20 W GHz amplified femtosecond laser source. This novel laser delivers burst energies up to 400 µJ, providing flexible intra-pulse repetition rates of 0.88 or 3.52 GHz, up to 200 pulses with â¼350 fs pulse duration. High-efficiency, high-quality ablation can be achieved through optimally determining the number of pulses, intra-pulse repetition, and average pulse energy within a burst. Due to such optimization, we demonstrate a specific ablation rate of 2.5 mm3/min/W with a burst containing 200 pulses at 0.88 GHz, which is the highest one reported so far for fs laser ablation, to the best of our knowledge. GHz ablation is sensitive to the selection of laser parameters. We conceptually discuss the contributions of the pulses within a burst to heat-accumulation-based incubation and material ablation.
RESUMO
We show, for the first time to our knowledge, the role the heat accumulation plays on the evolution of ultra-short pulse laser-induced surface structures morphology when varying fluence, the number of scans and the repetition rate from 100 kHz up to 2 MHz. We demonstrate how to tailor the size of micro-spikes from nearly ten microns to several tens of microns by a systematic variation of both fluence and overlap. We believe our results will contribute to an in deep understanding of the mechanisms underlying laser surface structuration at high repetition rates.
RESUMO
BACKGROUND: Coronary atherosclerosis progresses faster in patients with diabetes mellitus (DM) and causes higher morbidity and mortality in such patients compared to non-diabetics ones (non-DM). We quantify changes in plaque volume and plaque phenotype during lipid-lowering therapy in DM versus non-DM patients using advanced intracoronary imaging. METHODS: We analyzed data from 61 patients with stable angina pectoris included to the PREDICT trial searching for prediction of plaque changes during intensive lipid-lowering therapy (40 mg rosuvastatin daily). Geometrically correct, fully 3-D representation of the vascular wall surfaces and intravascular ultrasound virtual histology (IVUS-VH) defined tissue characterization was obtained via fusion of two-plane angiography and IVUS-VH. Frame-based indices of plaque morphology and virtual histology analyses were computed and averaged in 5 mm long baseline/follow-up registered vessel segments covering the entire length of the two sequential pullbacks (baseline, 1-year). We analyzed 698 5-mm-long segments and calculated the Liverpool active plaque score (LAPS). RESULTS: Despite reaching similar levels of LDL cholesterol (DM 2.12 ± 0.91 mmol/l, non-DM 1.8 ± 0.66 mmol/l, p = 0.21), DM patients experienced, compared to non-DM ones, higher progression of mean plaque area (0.47 ± 1.15 mm2 vs. 0.21 ± 0.97, p = 0.001), percent atheroma volume (0.7 ± 2.8% vs. - 1.4 ± 2.5%, p = 0.007), increase of LAPS (0.23 ± 1.66 vs. 0.13 ± 1.79, p = 0.018), and exhibited more locations with TCFA (Thin-Cap Fibro-Atheroma) plaque phenotype in 5 mm vessel segments (20.3% vs. 12.5%, p = 0.01). However, only non-DM patients reached significant decrease of LDL cholesterol. Plaque changes were more pronounced in PIT (pathologic intimal thickening) compared to TCFA with increased plaque area in both phenotypes in DM patients. CONCLUSION: Based on detailed 3D analysis, we found advanced plaque phenotype and further atherosclerosis progression in DM patients despite the same reached levels of LDLc as in non-DM patients. Trial registration ClinicalTrials.gov identifier: NCT01773512.
Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/efeitos dos fármacos , Angiopatias Diabéticas/tratamento farmacológico , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Placa Aterosclerótica , Rosuvastatina Cálcica/uso terapêutico , Ultrassonografia de Intervenção , Idoso , Biomarcadores/sangue , LDL-Colesterol/sangue , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Angiopatias Diabéticas/diagnóstico por imagem , Angiopatias Diabéticas/patologia , Progressão da Doença , Feminino , Fibrose , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Rosuvastatina Cálcica/efeitos adversos , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Over the last decade, significant advances in ST-elevation myocardial infarction (STEMI) workflow have resulted in most hospitals reporting door-to-balloon (D2B) times within the 90 min standard. Few programs have been enacted to systematically attempt to achieve routine D2B within 60 min. We sought to determine whether 24-hr in-house catheterization laboratory coverage via an In-House Interventional Team Program (IHIT) could achieve D2B times below 60 min for STEMI and to compare the results to the standard primary percutaneous coronary intervention (PCI) approach. METHODS: An IHIT program was established consisting of an attending interventional cardiologist, and a catheterization laboratory team present in-hospital 24 hr/day. For all consecutive STEMI patients, we compared the standard primary PCI approach during the two years prior to the program (group A) to the initial 20 months of the IHIT program (group B), and repeated this analysis for only CMS-reportable patients. The D2B process was analyzed by calculating workflow intervals. The primary endpoint was D2B process times, and secondary endpoints included in-hospital and 6-month cardiovascular outcomes and resource utilization. RESULTS: An IHIT program for STEMI resulted in significant reductions across all treatment intervals with an overall 57% reduction in D2B time, and an absolute reduction in mean D2B time of 71 min. There were no differences pre- and post-program implementation in regard to individual or composite components of in-hospital cardiovascular outcomes; however at 6 months, there was a reduction in cardiovascular rehospitalization after program implementation (30 vs. 5%, P < 0.01). The IHIT program resulted in a significant reduction in length-of-stay (LOS) (90 ± 102 vs. 197 ± 303 hr, P = 0.02), and critical care time (54 ± 97 vs. 149 ± 299 hr, P = 0.02). CONCLUSIONS: Availability of an in-house 24-hr STEMI team significantly decreased reperfusion time and led to improved clinical outcomes and a shorter LOS for PCI-treated STEMI patients.
Assuntos
Cateterismo Cardíaco , Atenção à Saúde , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Avaliação de Processos em Cuidados de Saúde , Tempo para o Tratamento , Plantão Médico , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/estatística & dados numéricos , Feminino , Recursos em Saúde/estatística & dados numéricos , Humanos , Illinois , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Equipe de Assistência ao Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/estatística & dados numéricos , Avaliação de Programas e Projetos de Saúde , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Fluxo de TrabalhoRESUMO
BACKGROUND: The flexible-tip irrigated ablation catheter Cool Flex™ (St. Jude Medical, St. Paul, MN, USA) was introduced to enhance cooling of the catheter-tissue interface and to conform to endocardial surface with better contact. Little is known about the performance of such catheter design compared to the widely used rigid-tip catheters. METHODS: In a thigh muscle preparation, ablation using the flexible-tip and rigid-tip catheters was performed in seven pigs across a range of ablation settings and catheter orientation. Postprocedure, the thigh muscle was stained with 2,3,5-triphenyltetrazolium-chloride injected into the femoral artery. The muscle was excised, fixed with formalin, and examined grossly. RESULTS: A total of 196 lesions (95 flexible tip, 101 rigid tip) were evaluated. The flexible-tip catheter was associated with enhanced cooling of catheter-tissue interface (31.1 ± 3.3°C vs 36.3 ± 3.7°C, P = 0.0001) in both perpendicular and nonperpendicular catheter orientations. This allowed more energy delivery (37.3 ± 8.9 W vs 33.7 ± 8.1 W, P = 0.004) to targeted tissue and resulted in larger lesions (median 194.7 [interquartile range: 113.1-333.8] mm(3) vs 170.9 [88.7-261.6] mm(3) , P = 0.03) than the rigid-tip catheter with larger maximum diameter (11.1 ± 2.6 mm vs 10.3 ± 2.1 mm, P = 0.03) and larger diameter at tissue surface (10.3 ± 2.4 mm vs 9.6 ± 1.7 mm, P = 0.01). Catheter orientation during ablation affected the efficiency of rigid-tip but not the flexible-tip catheter. The use of the flexible-tip catheter was associated with significantly less char formation on tissue (none vs 5.1% with rigid tip, P = 0.009). CONCLUSION: The Cool Flex™ catheter performed better than a rigid-tip catheter with enhanced cooling, larger ablation lesions, and no charring of targeted tissue.
Assuntos
Cateteres Cardíacos , Ablação por Cateter/instrumentação , Hipotermia Induzida/instrumentação , Músculo Esquelético/patologia , Músculo Esquelético/cirurgia , Irrigação Terapêutica/instrumentação , Animais , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Suínos , Resultado do TratamentoRESUMO
Much has changed in the last two years at DGVa (http://www.ebi.ac.uk/dgva) and dbVar (http://www.ncbi.nlm.nih.gov/dbvar). We are now processing direct submissions rather than only curating data from the literature and our joint study catalog includes data from over 100 studies in 11 organisms. Studies from human dominate with data from control and case populations, tumor samples as well as three large curated studies derived from multiple sources. During the processing of these data, we have made improvements to our data model, submission process and data representation. Additionally, we have made significant improvements in providing access to these data via web and FTP interfaces.
Assuntos
Bases de Dados de Ácidos Nucleicos , Variação Estrutural do Genoma , Genótipo , Humanos , Internet , FenótipoRESUMO
In the rat oviduct, estradiol (E2) accelerates egg transport by a nongenomic action that requires previous conversion of E2 to methoxyestrogens via catechol-O-methyltranferase (COMT) and activation of estrogen receptor (ER) with subsequent production of cAMP and inositol triphosphate (IP3). However, the role of the different oviductal cellular phenotypes on this E2 nongenomic pathway remains undetermined. The aim of this study was to investigate the effect of E2 on the levels of cAMP and IP3 in primary cultures of secretory and smooth muscle cells from rat oviducts and determine the mechanism by which E2 increases cAMP in the secretory cells. In the secretory cells, E2 increased cAMP but not IP3, while in the smooth muscle cells E2 decreased cAMP and increased IP3. Suppression of protein synthesis by actinomycin D did not prevent the E2-induced cAMP increase, but this was blocked by the ER antagonist ICI 182â780 and the inhibitors of COMT OR 486, G protein-α inhibitory (Gαi) protein pertussis toxin and adenylyl cyclase (AC) SQ 22536. Expression of the mRNA for the enzymes that metabolizes estrogens, Comt, Cyp1a1, and Cyp1b1 was found in the secretory cells, but this was not affected by E2. Finally, confocal immunofluorescence analysis showed that E2 induced colocalization between ESR1 (ERα) and Gαi in extranuclear regions of the secretory cells. We conclude that E2 differentially regulates cAMP and IP3 in the secretory and smooth muscle cells of the rat oviduct. In the secretory cells, E2 increases cAMP via a nongenomic action that requires activation of COMT and ER, coupling between ESR1 and Gαi, and stimulation of AC.
Assuntos
AMP Cíclico/metabolismo , Estradiol/farmacologia , Oviductos/efeitos dos fármacos , Receptores de Estrogênio/metabolismo , Transdução de Sinais/efeitos dos fármacos , Animais , Catecol O-Metiltransferase/metabolismo , Dactinomicina/farmacologia , Estradiol/análogos & derivados , Antagonistas do Receptor de Estrogênio/farmacologia , Feminino , Fulvestranto , Miócitos de Músculo Liso/efeitos dos fármacos , Miócitos de Músculo Liso/metabolismo , Oviductos/metabolismo , Ratos , Transdução de Sinais/fisiologiaRESUMO
Mating shuts down a 2-methoxyestradiol (2ME)-dependent, non-genomic activity that is responsible for accelerating egg transport in the rat oviduct. The aims of this work were to investigate the role of TGFß1 in this 2ME-reduced activity and to determine the effect of mating on the expression and distribution of TGFß1 and its receptor TGFBR3 in the rat oviduct. We determined the level of TGFß1 in the plasma and oviductal fluid at 1, 3, or 6 hr during Day 1 of the oestrous cycle in unmated or mated animals. We then examined if 2ME accelerates oviductal egg transport in unmated rats that were previously treated with a neutralizing TGFß1 antibody. The expression of Tgfb1 and Tgfbr3 mRNA and the level and distribution of TGFBR3 protein in the oviduct were also determined at these time points. Mating decreased TGFß1 in the plasma, but not in the oviductal fluid, whereas antibody neutralization of circulating TGFß1 did not prevent the effect of 2ME on egg transport. Mating decreased Tgfb1 and hastened the increase in TGFBR3 abundance in the myosalpinx. These results indicate that mating decreased circulating levels of TGFß1 without shutting down the non-genomic 2ME response that normally accelerates egg transport. Levels of Tgfb1 transcript and TGFBR3 protein, however, changed in the myosalpinx of mated rats, suggesting a role for mating-associated factors in the autocrine and paracrine effects of TGFß in the oviduct.