Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biofouling ; 28(1): 99-109, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22257312

RESUMO

Recent studies evaluating bulk soap in public restroom soap dispensers have demonstrated up to 25% of open refillable bulk-soap dispensers were contaminated with ~ 6 log(10)(CFU ml(-1)) heterotrophic bacteria. In this study, plastic counter-mounted, plastic wall-mounted and stainless steel wall-mounted dispensers were analyzed for suspended and biofilm bacteria using total cell and viable plate counts. Independent of dispenser type or construction material, the bulk soap was contaminated with 4-7 log(10)(CFU ml(-1)) bacteria, while 4-6 log(10)(CFU cm(-2)) biofilm bacteria were isolated from the inside surfaces of the dispensers (n = 6). Dispenser remediation studies, including a 10 min soak with 5000 mg l(-1) sodium hypochlorite, were then conducted to determine the efficacy of cleaning and disinfectant procedures against established biofilms. The testing showed that contamination of the bulk soap returned to pre-test levels within 7-14 days. These results demonstrate biofilm is present in contaminated bulk-soap dispensers and remediation studies to clean and sanitize the dispensers are temporary.


Assuntos
Bactérias/isolamento & purificação , Biofilmes/efeitos dos fármacos , Recuperação e Remediação Ambiental/métodos , Fômites/microbiologia , Logradouros Públicos , Sabões/análise , Bactérias/efeitos dos fármacos , Bactérias/crescimento & desenvolvimento , Carga Bacteriana , Desinfetantes/farmacologia , Desinfecção/métodos , Microbiologia Ambiental , Contaminação de Equipamentos/prevenção & controle , Mãos , Desinfecção das Mãos/métodos , Humanos , Plásticos/análise , Hipoclorito de Sódio/farmacologia , Aço Inoxidável/análise , Fatores de Tempo
2.
J Microbiol Methods ; 174: 105963, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32454049

RESUMO

A standard method for growing Pseudomonas aeruginosa biofilm in the Drip Flow Biofilm Reactor was assessed in a 10-laboratory study. The mean log density was 9.29 Log10(CFU/cm2). The repeatability and reproducibility SDs were equal to 0.22 and 0.24, respectively, providing statistical confidence in data generated by the method.


Assuntos
Biofilmes/crescimento & desenvolvimento , Reatores Biológicos , Pseudomonas aeruginosa/crescimento & desenvolvimento , Fermentação , Reprodutibilidade dos Testes
3.
Nat Protoc ; 4(5): 783-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19528953

RESUMO

This protocol describes how to grow a Pseudomonas aeruginosa biofilm under low fluid shear close to the air-liquid interface using the drip flow reactor (DFR). The DFR can model environments such as food-processing conveyor belts, catheters, lungs with cystic fibrosis and the oral cavity. The biofilm is established by operating the reactor in batch mode for 6 h. A mature biofilm forms as the reactor operates for an additional 48 h with a continuous flow of nutrients. During continuous flow, the biofilm experiences a low shear as the media drips onto a surface set at a 10 degrees angle. At the end of 54 h, biofilm accumulation is quantified by removing coupons from the reactor channels, rinsing the coupons to remove planktonic cells, scraping the biofilm from the coupon surface, disaggregating the clumps, then diluting and plating for viable cell enumeration. The entire procedure takes 13 h of active time that is distributed over 5 d.


Assuntos
Técnicas Bacteriológicas , Biofilmes/crescimento & desenvolvimento , Reatores Biológicos , Pseudomonas aeruginosa/fisiologia , Técnicas Bacteriológicas/instrumentação , Fenômenos Biomecânicos , Propriedades de Superfície , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA