Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Clin Chem ; 66(3): 434-444, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32109298

RESUMO

BACKGROUND: How to select healthy reference subjects in deriving 99th percentiles for cardiac troponin assays still needs to be clarified. To assist with global implementation of high sensitivity (hs)-cardiac troponin (cTn) I and hs-cTnT assays in clinical practice, we determined overall and sex-specific 99th percentiles in 9 hs-cTnI and 3 hs-cTnT assays using a universal sample bank (USB). METHODS: The Universal Sample Bank (USB) comprised healthy subjects, 426 men and 417 women, screened using a health questionnaire. Hemoglobin A1c (>URL 6.5%), NT-proBNP (>URL 125 ng/L) and eGFR (<60 mL/min), were used as surrogate biomarker exclusion criteria along with statin use. 99th percentiles were determined by nonparametric, Harrell--Davis bootstrap, and robust methods. RESULTS: Subjects were ages 19 to 91 years, Caucasian 58%, African American 27%, Pacific Islander/Asian 11%, other 4%, Hispanic 8%, and non-Hispanic 92%. The overall and sex-specific 99th percentiles for all assays, before and after exclusions (n = 694), were influenced by the statistical method used, with substantial differences noted between and within both hs-cTnI and hs-cTnT assays. Men had higher 99th percentiles (ng/L) than women. The Roche cTnT and Beckman and Abbott cTnI assays (after exclusions) did not measure cTn values at ≥ the limit of detection in ≥50% women. CONCLUSIONS: Our findings have important clinical implications in that sex-specific 99th percentiles varied according to the statistical method and hs-cTn assay used, not all assays provided a high enough percentage of measurable concentrations in women to qualify as a hs-assay, and the surrogate exclusion criteria used to define normality tended to lower the 99th percentiles.


Assuntos
Bioensaio/métodos , Troponina I/sangue , Troponina T/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioensaio/normas , Bancos de Espécimes Biológicos , Biomarcadores/sangue , Feminino , Humanos , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Kit de Reagentes para Diagnóstico , Valores de Referência , Fatores Sexuais , Troponina I/normas , Troponina T/normas , Adulto Jovem
3.
Clin Chem ; 63(1): 369-376, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27811203

RESUMO

BACKGROUND: Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. METHODS: Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration

Assuntos
Isquemia Miocárdica/sangue , Troponina I/sangue , Doença Aguda , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico
4.
Clin Chem ; 63(10): 1594-1604, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28701316

RESUMO

BACKGROUND: We examined the diagnostic performance of high-sensitivity cardiac troponin I (hs-cTnI) vs contemporary cTnI with use of the 99th percentile alone and with a normal electrocardiogram (ECG) to rule out acute myocardial infarction (MI) and serial changes (deltas) to rule in MI. METHODS: We included consecutive patients presenting to a US emergency department with serial cTnI onclinical indication. Diagnostic performance for acute MI, including MI subtypes, and 30-day outcomes were examined. RESULTS: Among 1631 patients, MI was diagnosed in 12.9% using the contemporary cTnI assay and in 10.4% using the hs-cTnI assay. For ruling out MI, contemporary cTnI ≤99th percentile at 0, 3, and 6 h and a normal ECG had a negative predictive value (NPV) of 99.5% (95% CI, 98.6-100) and a sensitivity of 99.1% (95% CI, 97.4-100) for diagnostic and safety outcomes. Serial hs-cTnI measurements ≤99th percentile at 0 and 3 h and a normal ECG had an NPV and sensitivity of 100% (95% CI, 100-100) for diagnostic and safety outcomes. For ruling in MI, contemporary cTnI measurements had specificities of 84.4% (95% CI, 82.5-86.3) at presentation and 78.7% (95% CI, 75.4-82.0) with serial testing at 0, 3, and 6 h, improving to 89.2% (95% CI, 87.1-91.3) by using serial cTnI changes (delta, 0 and 6 h) >150%. hs-cTnI had specificities of 86.9% (95% CI, 85.1-88.6) at presentation and 85.7% (95% CI, 83.5-87.9) with serial testing at 0 and 3 h, improving to 89.3% (95% CI, 87.3-91.2) using a delta hs-cTnI (0 and 3 h) >5 ng/L. CONCLUSIONS: hs-cTnI and contemporary cTnI assays are excellent in ruling out MI following recommendations predicated on serial testing and the 99th percentile with a normal ECG. For ruling in MI, deltas improve the specificity. ClinicalTrials.gov Identifier: NCT02060760.


Assuntos
Infarto do Miocárdio/diagnóstico , Troponina I/análise , Biomarcadores/análise , Técnicas de Laboratório Clínico , Feminino , Humanos , Masculino , Prognóstico , Sensibilidade e Especificidade
5.
Clin Chem ; 62(8): 1115-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27324737

RESUMO

INTRODUCTION: We compared the incidence of undetectable [below the limit of detection (LoD)], measurable (LoD to 99th percentile), and increased cardiac troponin I (cTnI) concentrations above the 99th percentile between Abbott high-sensitivity cTnI (hs-cTnI) and contemporary cTnI assays in a US emergency department population. METHODS: Patients (n = 2100) presenting to the emergency department who had serial cTnI (0, 3, 6, 9 h) measurements ordered on clinical indication were enrolled. Contemporary cTnI [Abbott Architect used clinically; 99th percentile: 0.030 µg/L (30 ng/L)] and hs-cTnI [Abbott investigational; sex-specific 99th percentiles: female (F) 16 ng/L, male (M) 34 ng/L] assays simultaneously measured fresh EDTA plasma. RESULTS: The hs-cTnI assay measured fewer undetectable cTnI concentrations compared to the contemporary cTnI assay across baseline (F: 31% vs 47%, M: 22% vs 40%) and serial (F: 21% vs 46%; M: 19% vs 54%) measurements. Conversely, the proportion of measurable cTnI concentrations was higher using hs-cTnI compared to contemporary cTnI assay across both baseline (F: 46% vs 31%; M: 60% vs 33%) and serial (F: 48% vs 28%; M: 83% vs 40%) measurements. The overall proportion of patients with increased cTnI concentrations above the 99th percentile was not significantly different between the contemporary (31%) and hs-cTnI (26%) assays (P = 0.09). CONCLUSIONS: In patients presenting to the emergency department, the use of the Abbott hs-cTnI assay provides clinicians with more numeric cTnI concentrations. This occurs via a shift from results below the LoD to those between the LoD and the 99th percentile and does not increase in the number of cTnI concentrations above the 99th percentile.


Assuntos
Análise Química do Sangue , Serviço Hospitalar de Emergência , Troponina I/sangue , Idoso , Análise Química do Sangue/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Sensibilidade e Especificidade
6.
Clin Chem ; 62(4): 631-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26847217

RESUMO

INTRODUCTION: Serial changes in cardiac troponin in hemodialysis (HD) patients have uncertain clinical implications. We evaluated associations of adverse outcomes in HD patients with reference change value (RCV) data and tertile concentrations for cardiac troponin I (cTnI) and cTnT measured by high-sensitivity (hs) assays. METHODS: RCV data and tertiles for hs-cTnI and hs-cTnT were determined from plasma samples collected 3 months apart in 677 stable outpatient HD patients and assessed for their associations with adverse outcomes using adjusted Cox models. Primary outcomes were all-cause mortality and sudden cardiac death (SCD). RESULTS: During a median follow-up of 23 months, 18.6% of patients died. RCVs were: hs-cTnI +37% and -30%; hs-cTnT +25% and -20%. Patients with serial hs-cTnI and hs-cTnT changes >RCV (increase or decrease) had all-cause mortality of 25.2% and 23.8% respectively, compared to 15.0% and 16.5% with changes ≤RCV [adjusted hazard ratios (aHRs): 1.9, P = 0.0003 and 1.7, P = 0.0066), respectively]. Only hs-cTnI changes >RCV were predictive of SCD (aHR 2.6, P = 0.005). hs-Cardiac troponin changes >RCV improved all-cause mortality prognostication compared to changes ≤RCV in tertile 2: hs-cTnI aHR, 2.70 (P = 0.003); hs-cTnT aHR, 1.98 (P = 0.043). The aHR of changes in hs-cTnI in tertile 2 >RCV for SCD was 5.62 (P = 0.039). CONCLUSIONS: Changes over 3 months in hs-cTnI and hs-cTnT of >RCV identified patients at greater risk of all-cause mortality, and for hs-cTnI were also predictive of SCD. Among patients with middle tertile cardiac troponin concentrations, hs-cTnI changes >RCV provided additive prognostic value for both SCD and all-cause mortality, whereas those for hs-cTnT provided additive prognostic value only for all-cause mortality.


Assuntos
Causas de Morte/tendências , Morte Súbita Cardíaca/epidemiologia , Falência Renal Crônica/mortalidade , Diálise Renal , Troponina I/sangue , Troponina T/sangue , Feminino , Humanos , Estimativa de Kaplan-Meier , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Limite de Detecção , Masculino , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Valores de Referência , Diálise Renal/estatística & dados numéricos
7.
Clin Chem ; 61(4): 657-63, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25672334

RESUMO

BACKGROUND: The frequency and characteristics of myocardial infarction (MI) subtypes per the Third Universal Definition of MI (TUDMI) classification system using high-sensitivity (hs) cardiac troponin assays with sex-specific cutoffs is not well known. We sought to describe the diagnostic characteristics of type 1 (T1MI) and type 2 (T2MI) MI using an hs-cardiac troponin I (hs-cTnI) assay with sex-specific cutoffs. METHODS: A total of 310 consecutive patients with serial cTnI measurements obtained on clinical indication were studied with contemporary and hs-cTnI assays. Ninety-ninth percentile sex-specific upper reference limits (URLs) for the hs-cTnI assay were 16 ng/L for females and 34 ng/L for males. The TUDMI consensus recommendations were used to define and adjudicate MI based on each URL. RESULTS: A total of 127 (41%) patients had at least 1 hs-cTnI exceeding the sex-specific 99th percentiles, whereas 183 (59%) had hs-cTnI within the reference interval. Females had more myocardial injury related to supply/demand ischemia than males (39% vs 18%, P = 0.01), whereas males had more multifactorial or indeterminate injury (52% vs 33%, P = 0.05). By hs-cTnI, there were 32 (10%) acute MIs, among which 10 (3%) were T1MI and 22 (7%) were T2MI. T2MI represented 69% (22 out of 32) of all acute MIs, whereas T1MI represented 31% (10 out of 32). Ninety-five patients (31%) had an increased hs-cTnI above the 99th percentile but did not meet criteria for acute MI. The most common triggers for T2MI were tachyarrhythmias, hypotension/shock, and hypertension. By contemporary cTnI, more MIs (14 T1MI and 29 T2MI) were diagnosed. By contemporary cTnI, there were 43 MIs, 14 T1MI, and 29 T2MI. CONCLUSIONS: Fewer MI diagnoses were found with the hs-cTnI assay, contrary to the commonly accepted idea that hs-cTnI will lead to excessive false-positive diagnoses.


Assuntos
Infarto do Miocárdio/sangue , Troponina I/sangue , Idoso , Algoritmos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/classificação , Projetos Piloto , Valores de Referência , Estudos Retrospectivos , Fatores Sexuais , Estados Unidos
8.
Clin Chem ; 61(3): 498-504, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25538265

RESUMO

BACKGROUND: We assessed the utilization rationale behind provider ordering of cardiac troponin I (cTnI) testing for the diagnosis of myocardial infarction after implementation of a hospital-wide serial order protocol. METHODS: During 2 months in 2013, any request for additional cTnI testing within 30 days of the initial serial cTnI order prompted an electronic health record best practice alert (BPA), which included clinical decision support that could be bypassed by giving a clinical indication. cTnI orders were not limited (timing, number), and upon BPA, trigger data was collected for clinical indications and actions, patient stay (duration, location), International Classification of Diseases, Revision 9 diagnosis, cTnI orders, and timing of cTnI measurements. RESULTS: The BPA was triggered 1477 times by 423 providers who cared for 702 patients. There were a mean of 3.6 cTnI results per patient, 2.1 BPAs per patient, and 1.2 visits per patient. Providers (42% of whom were residents) acknowledged and overrode the BPA 97% of the time. In response to the BPA, 65% of providers selected a prepared rationale: 64% acute coronary syndrome/ST-elevation myocardial infarction/non-ST-elevation myocardial infarction; 30% demand ischemia; and 6% non-ACS myocardial necrosis. Of the remaining 35% of providers, 71% listed no rationale for their additional cTnI orders. Of patients with a BPA, 93% had non-ACS-related primary International Classification of Diseases, Revision 9 diagnosis, and 58% of the time, patients' cTnI results never increased during their stay. In 53% of cases, BPAs were generated by a request for an additional cTnI series when <2 results were available. CONCLUSIONS: Providers largely ignored the BPA that warned of potential overutilization of cTnI testing independent of diagnosis, including ACS.


Assuntos
Registros Eletrônicos de Saúde , Infarto do Miocárdio/diagnóstico , Troponina I/sangue , Procedimentos Desnecessários/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Sistemas de Registro de Ordens Médicas , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Adulto Jovem
9.
Am J Clin Pathol ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39066575

RESUMO

OBJECTIVES: Urine drug testing (UDT) is a critical tool used in medical, forensic, and occupational settings, but interpreting results can be challenging. We performed a study to assess the ability of health care professionals to interpret UDT results accurately. METHODS: In total, 911 clinical and laboratory professionals in the United States and Canada responded to a survey with questions gauging expertise in UDT interpretation. Responses were analyzed to identify knowledge gaps. RESULTS: Toxicologists and laboratory PhD scientists performed well, with means of 4.82 and 4.63 questions answered correctly (out of 6 possible), respectively. Physicians specializing in pathology, emergency medicine, primary care, and internal medicine, however, displayed concerning knowledge gaps, as did laboratorians with nondoctoral degrees. Experience and training correlated with interpretation accuracy. Identification of simulated compliance as well as understanding opioid exposure, metabolism, and immunoassay cross-reactivity were among the most clinically significant knowledge gaps. More than 30% of survey respondents indicated that they would seek UDT information from the internet or peers rather than clinical or laboratory experts. CONCLUSIONS: The study highlighted the need for targeted education and better collaboration between clinical and laboratory experts and other health care professionals to ensure that when physicians order UDT, they can accurately interpret results and reduce harm.

10.
Analyst ; 137(13): 3004-10, 2012 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-22382603

RESUMO

As nanoparticles enjoy increasingly widespread use in commercial applications, the potential for unintentional exposure has become much more likely during any given day. Researchers in the field of nanotoxicity are working to determine the physicochemical nanoparticle properties that lead to toxicity in an effort to establish safe design rules. This work explores the effects of noble metal nanoparticle exposure in murine chromaffin cells, focusing on examining the effects of size and surface functionality (coating) in silver and gold, respectively. Carbon-fibre microelectrode amperometry was utilized to examine the effect of exposure on exocytosis function, at the single cell level, and provided new insights into the compromised functions of cells. Silver nanoparticles of varied size, between 15 and 60 nm diameter, were exposed to cells and found to alter the release kinetics of exocytosis for those cells exposed to the smallest examined size. Effects of gold were examined after modification with two commonly used 'bio-friendly' polymers, either heparin or poly (ethylene glycol), and gold nanoparticles were found to induce altered cellular adhesion or the number of chemical messenger molecules released, respectively. These results support the body of work suggesting that noble metal nanoparticles perturb exocytosis, typically altering the number of molecules and kinetics of release, and supports a direct disruption of the vesicle matrix by the nanoparticle. Overall, it is clear that various nanoparticle physicochemical properties, including size and surface coating, do modulate changes in cellular communication via exocytosis.


Assuntos
Comunicação Celular , Nanopartículas Metálicas , Células Neuroendócrinas/citologia
11.
Anal Bioanal Chem ; 400(9): 2963-71, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21523329

RESUMO

Cell-cell communication is often achieved via granular exocytosis, as in neurons during synaptic transmission or neuroendocrine cells during blood hormone control. Owing to its critical role in membrane properties and SNARE function, cholesterol is expected to play an important role in the highly conserved process of exocytosis. In this work, membrane cholesterol concentration is systematically varied in primary culture mouse chromaffin cells, and the change in secretion behavior of distinct vesicle pools as well as pool recovery following stimulation is measured using carbon-fiber microelectrode amperometry. Amperometric traces obtained from activation of the younger readily releasable and slowly releasable pool (RRP/SRP) vesicles at depleted cholesterol levels showed fewer sustained fusion pore features (6.1 ± 1.1% of spikes compared with 11.2 ± 1.0% for control), revealing that cholesterol content influences fusion pore formation and stability during exocytosis. Moreover, subsequent stimulation of RRP/SRP vesicles showed that cellular cholesterol level influences both the quantal recovery and kinetics of the later release events. Finally, diverging effects of cholesterol on RRP and the older reserve pool vesicle release suggest two different mechanisms for the release of these two vesicular pools.


Assuntos
Colesterol/metabolismo , Células Cromafins/citologia , Técnicas Eletroquímicas/métodos , Exocitose , Animais , Membrana Celular/metabolismo , Células Cultivadas , Células Cromafins/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Microeletrodos , Vesículas Secretórias
13.
Anal Bioanal Chem ; 398(2): 677-88, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20428848

RESUMO

Using two of the most commonly synthesized noble metal nanoparticle preparations, citrate-reduced Au and Ag, the impacts of short-term accidental nanoparticle exposure are examined in primary culture murine adrenal medullary chromaffin cells. Transmission electron microscopy (TEM), inductively coupled plasma atomic emission spectroscopy (ICP-AES) and Alamar Blue viability studies revealed that nanoparticles are taken up by cells but do not decrease cell viability within 48 hours of exposure. Carbon-fiber microelectrode amperometry (CFMA) examination of exocytosis in nanoparticle-exposed cells revealed that nanoparticle exposure does lead to decreased secretion of chemical messenger molecules, of up to 32.5% at 48 hours of Au exposure. The kinetics of intravesicular species liberation also slows after nanoparticle exposure, between 30 and 50% for Au and Ag, respectively. Repeated stimulation of exocytosis demonstrated that these effects persisted during subsequent stimulations, meaning that nanoparticles do not interfere directly with the vesicle recycling machinery but also that cellular function is unable to recover following vesicle content expulsion. By comparing these trends with parallel studies done using mast cells, it is clear that similar exocytosis perturbations occur across cell types following noble metal nanoparticle exposure, supporting a generalizable effect of nanoparticle-vesicle interactions.


Assuntos
Células Cromafins/citologia , Ouro/efeitos adversos , Nanopartículas Metálicas/efeitos adversos , Células Neuroendócrinas/citologia , Prata/efeitos adversos , Animais , Permeabilidade da Membrana Celular , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Células Cromafins/metabolismo , Exocitose/efeitos dos fármacos , Ouro/química , Ouro/farmacocinética , Masculino , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Camundongos , Camundongos Endogâmicos C57BL , Microeletrodos , Microscopia Eletrônica de Transmissão , Células Neuroendócrinas/metabolismo , Prata/química , Prata/farmacocinética , Espectrofotometria Atômica
14.
Analyst ; 134(3): 425-39, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19238274

RESUMO

During the past 20 years, improvements in nanoscale materials synthesis and characterization have given scientists great control over the fabrication of materials with features between 1 and 100 nm, unlocking many unique size-dependent properties and, thus, promising many new and/or improved technologies. Recent years have found the integration of such materials into commercial goods; a current estimate suggests there are over 800 nanoparticle-containing consumer products (The Project on Emerging Nanotechnologies Consumer Products Inventory, , accessed Oct. 2008), accounting for 147 billion USD in products in 2007 (Nanomaterials state of the market Q3 2008: stealth success, broad impact, Lux Research Inc., New York, NY, 2008). Despite this increase in the prevalence of engineered nanomaterials, there is little known about their potential impacts on environmental health and safety. The field of nanotoxicology has formed in response to this lack of information and resulted in a flurry of research studies. Nanotoxicology relies on many analytical methods for the characterization of nanomaterials as well as their impacts on in vitro and in vivo function. This review provides a critical overview of these techniques from the perspective of an analytical chemist, and is intended to be used as a reference for scientists interested in conducting nanotoxicological research as well as those interested in nanotoxicological assay development.


Assuntos
Nanopartículas/toxicidade , Animais , Técnicas de Química Analítica/métodos , Modelos Animais de Doenças , Saúde Ambiental/métodos , Humanos , Teste de Materiais/métodos , Camundongos , Microscopia Eletrônica , Nanopartículas/química , Nanotecnologia/métodos , Ratos
15.
J Appl Lab Med ; 4(2): 180-192, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31639663

RESUMO

BACKGROUND: GEM Premier ChemSTAT™ is a point-of-care (POC) system that measures Na+, K+, Ca++, Cl-, glucose, hematocrit, creatinine, blood urea nitrogen (BUN), tCO2, pH, pCO2, and lactate from a single whole blood specimen, providing rapid results in POC settings such as the emergency department (ED). Accurate measurements of creatinine in whole blood and reporting of estimated glomerular filtration rate (eGFR) can minimize adverse effects of contrast-induced nephropathy. METHODS: Heparinized whole blood specimens from the ED were analyzed on the ChemSTAT by POC staff. Method comparison was performed against the cobas Integra c501 for creatinine, BUN, and tCO2, and against the GEM Premier 4000 for all other analytes. Precision was conducted with whole blood specimens assayed in triplicate over 6 days. Creatinine results from whole blood and plasma were used for eGFR, by isotope dilution mass spectrometry-traceable Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration equations, and eGFR concordance was assessed. RESULTS: Creatinine, BUN, and tCO2 correlated well with plasma samples on the cobas, and all other analytes correlated well with whole blood specimens on the GEM Premier 4000 across the tested sample ranges. The regression slope was 0.951 to 1.047, along with a correlation coefficient (r) of ≥0.982 for all analytes. The pooled within-sample precision was 0% to 2.5% for all analytes. CONCLUSIONS: ChemSTAT demonstrated a strong correlation with the comparative methods and excellent precision. The system's analytical performance and continuous quality management make it suitable for use in the ED to provide rapid reliable test results, which could minimize the time to treatment and improve ED efficiency.


Assuntos
Creatinina/sangue , Testes Diagnósticos de Rotina/instrumentação , Nefropatias/diagnóstico , Rim/fisiologia , Testes Imediatos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Nitrogênio da Ureia Sanguínea , Dióxido de Carbono/sangue , Criança , Meios de Contraste/efeitos adversos , Serviço Hospitalar de Emergência , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Rim/diagnóstico por imagem , Nefropatias/sangue , Nefropatias/induzido quimicamente , Nefropatias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
16.
Am J Med ; 132(7): 869-874, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30849383

RESUMO

OBJECTIVE: Our objective was to examine the appropriateness of cardiac troponin (cTn) testing among patients with cTn increases. METHODS: This is a planned secondary analysis of the Use of TROPonin In Acute coronary syndromes (UTROPIA, NCT02060760) observational cohort study. Appropriateness of cTn testing was adjudicated for emergency department patients with cTn increases >99th percentile and analyzed using both contemporary and high-sensitivity (hs) cTnI assays according to sub-specialty, diagnoses, and symptoms. RESULTS: Appropriateness was determined from 1272 and 1078 adjudication forms completed for 497 and 422 patients with contemporary and hs-cTnI increases, respectively. Appropriateness of cTnI testing across adjudication forms was 71.5% and 72.0% for cTnI and hs-cTnI, respectively. Compared with emergency physicians, cardiologists were less likely to classify cTnI orders as appropriate (cTnI: 79% vs 56%, P < .0001; hs-cTnI: 82% vs 51%, P < .0001). For contemporary cTnI, appropriateness of 95%, 70%, and 39% was observed among adjudication forms completed by cardiologists for type 1 myocardial infarction, type 2 myocardial infarction, and myocardial injury, respectively; compared with 90%, 86%, and 71%, respectively, among emergency physicians. Similar findings were observed using hs-cTnI. Discordance in appropriateness adjudication forms occurred most frequently in cases of myocardial injury (62% both assays) or type 2 myocardial infarction (cTnI 31%; hs-cTnI 23%). CONCLUSIONS: Marked differences exist in the perception of what constitutes appropriate clinical use of cTn testing between cardiologists and emergency physicians, with emergency physicians more likely to see testing as appropriate across a range of clinical scenarios. Discordance derives most often from cases classified as myocardial injury or type 2 myocardial infarction.


Assuntos
Síndrome Coronariana Aguda/sangue , Troponina C/sangue , Adulto , Biomarcadores/sangue , Cardiologia/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Masculino , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Padrões de Prática Médica/estatística & dados numéricos
17.
J Forensic Sci ; 63(1): 191-194, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28422290

RESUMO

Over the past two decades, prescription and illicit opioid use has led to changes in public health policy to address the increasing number of opioid-related deaths. The purpose of this study was to review cases from Hennepin County Medical Examiner's Office between 2004 through 2015 where heroin was listed as a significant contributor or as the cause of death. We identified 322 heroin-related deaths, which were predominantly male (255; 79%). 6-Monoacetylmorphine (6-MAM) median (range) concentrations were as follows: blood (n = 7), 0.010 (0.006-0.078) mg/L; urine (n = 30), 0.359 (0.009-1.75) mg/L; and vitreous humor (n = 31), 0.034 (0.004-0.24) mg/L. Free morphine was measurable in 273 cases and the percent free morphine (range), when grouped by COD, was opioid (n = 124), 28% (2.2%-92%), and mixed drug toxicity (n = 135), 35.3% (1.5%-100%); (p < 0.01). Quantitation of 6-MAM in blood and vitreous humor, along with a free to total morphine ratio >26%, was useful in establishing heroin-related deaths.


Assuntos
Dependência de Heroína/mortalidade , Acidentes/estatística & dados numéricos , Adulto , Médicos Legistas , Overdose de Drogas/mortalidade , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Dependência de Heroína/sangue , Dependência de Heroína/urina , Homicídio/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Morfina/análise , Derivados da Morfina/análise , Estudos Retrospectivos , Distribuição por Sexo , Suicídio/estatística & dados numéricos , Corpo Vítreo/química
18.
Acad Forensic Pathol ; 8(3): 729-737, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31240067

RESUMO

Over a three-month period in early 2017, the Hennepin County Medical Examiner's Office investigated nine apparent opioid toxicity deaths that occurred in three separate urban, suburban, and rural counties in our jurisdiction. All decedents were known substance abusers and had reportedly recently used heroin; most were found with drug paraphernalia. Complete autopsies variably showed classic stigmata of opioid overdose with no significant injury or natural disease to explain death. Initial toxicology screens failed to identify heroin or other narcotic substances. Several cases were presumptively positive for fentanyl by immunoassay, yet failed to confirm positive for fentanyl. Following American Board of Forensic Toxicology reporting standards, these cases were reported as negative for fentanyl by the laboratory. Due to the discrepant scene and toxicology findings suggestive of an opioid toxicity death, further discussion between the medical examiners and toxicologists prompted additional testing at a referral laboratory. This resulted in quantifiable blood carfentanil in all cases (mean 0.26 ng/mL, range 0.12 - 0.64 ng/mL). Cointoxicants included ethanol (n=2), methamphetamine (n=3), benzodiazepines (n=3), and cocaine (n=1). No case had definitive evidence of acute heroin intoxication, but two cases had low concentrations of morphine present (0.03 and 0.06 ng/mL), and two others had 6-monoacetyl morphine in the urine without morphine in the blood, suggesting recent use. All deaths were certified as accidental acute or mixed carfentanil toxicity. These cases present additional information about carfentanil-related deaths and highlight the importance of collaboration between forensic pathologists and toxicologists.

19.
Am J Clin Pathol ; 149(1): 82-86, 2017 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-29228083

RESUMO

OBJECTIVES: The present study addressed the accuracy of calculated oxygen saturation (sO2) using point-of-care (POC) testing compared with measured values on a blood gas analyzer. METHODS: In total, 3,323 sO2 values were measured in 1,180 patients using a CO-oximeter (ABL 800 Flex; Radiometer, Copenhagen, Denmark). Measured parameters were then used to calculate an expected sO2 for the POC method (Abbott i-STAT; Abbott POC, Princeton, NJ). Cases in which calculated sO2 differed from measured sO2 by 10% or more were analyzed. RESULTS: Of the 3,323 comparisons performed, 260 (8%) showed discrepancies (± ≥10%) between measured and calculated sO2 values. Ninety-four of discrepant measurements (245 of 260) occurred when pO2 was less than 50 mm Hg. pH and bicarbonate distributions shifted to lower values in discrepant vs nondiscrepant cases. CONCLUSIONS: Our results suggest that the likelihood of discrepant sO2 is 27% among patients with pO2 less than 50 mm Hg. Direct measurement of sO2 by CO-oximetry is strongly suggested in this clinical scenario.


Assuntos
Gasometria/normas , Hipóxia/sangue , Oxigênio/sangue , Testes Imediatos/normas , Gasometria/instrumentação , Feminino , Humanos , Masculino , Oximetria , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Am J Med ; 130(9): 1076-1083.e1, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28344141

RESUMO

BACKGROUND: This study examined the performance of single high-sensitivity cardiac troponin I (hs-cTnI) measurement strategies to rule out acute myocardial infarction. METHODS: This was a prospective, observational study of consecutive patients presenting to the emergency department (n = 1631) in whom cTnI measurements were obtained using an investigational hs-cTnI assay. The goals of the study were to determine 1) negative predictive value (NPV) and sensitivity for the diagnosis of acute myocardial infarction, type 1 myocardial infarction, and type 2 myocardial infarction; and 2) safety outcome of acute myocardial infarction or cardiac death at 30 days using hs-cTnI less than the limit of detection (LoD) (<1.9 ng/L) or the High-STEACS threshold (<5 ng/L) alone and in combination with normal electrocardiogram (ECG). RESULTS: Acute myocardial infarction occurred in 170 patients (10.4%), including 68 (4.2%) type 1 myocardial infarction and 102 (6.3%) type 2 myocardial infarction. For hs-cTnI

Assuntos
Infarto do Miocárdio/sangue , Troponina I/sangue , Doença Aguda , Bioensaio/métodos , Biomarcadores/sangue , Eletrocardiografia , Serviço Hospitalar de Emergência/estatística & dados numéricos , Humanos , Infarto do Miocárdio/diagnóstico , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA