Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Chem Phys ; 152(11): 114201, 2020 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-32199443

RESUMO

Singlet fission is one of the most promising routes to overcome the single-junction efficiency limit for solar cells. Singlet fission-enhanced silicon solar cells are the most desirable implementation, but transfer of triplet excitons, the product of singlet fission, into silicon solar cells has proved to be very challenging. Here, we report on an all optical measurement technique for the detection of triplet exciton quenching at semiconductor interfaces, a necessary requirement for triplet exciton or charge transfer. The method relies on the growth of individual, single-crystal islands of the singlet fission material on the silicon surface. The islands have different heights, and we correlate these heights to the quenching efficiency of triplet excitons. The quenching efficiency is measured by spatially resolved delayed fluorescence and compared to a diffusion-quenching model. Using silicon capped with a blocking thermal oxide and aromatic monolayers, we demonstrate that this technique can quickly screen different silicon surface treatments for triplet exciton quenching.

2.
Artigo em Inglês | MEDLINE | ID: mdl-20065513

RESUMO

Microscope mode mass spectrometric imaging is crucially dependent on the availability of a high- resolution, position-resolved time-of-flight detector. Here, a new detection method for microscope mode imaging mass spectrometry is presented. A delay-line detector has been used for the first time as a position-sensitive detector in imaging mass spectrometry. The method is implemented on a matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF), as well as a secondary ion mass spectrometry time-of-flight (SIMS-ToF) instrument. Trypsinogen and bovine serum albumin samples have been used with a metal mask to determine the spatial resolution of the new detector using the MALDI-ToF instrument. The new detector set-up was successfully employed to generate mass resolved SIMS images from biological structures on the surface of thin tissue sections. The biological samples studied were taken from tumor grown from xenografted breast cancer cell lines and chicken embryonal sections.


Assuntos
Neoplasias da Mama/patologia , Espectrometria de Massas/instrumentação , Microscopia/instrumentação , Microscopia/métodos , Animais , Bovinos , Linhagem Celular Tumoral , Embrião de Galinha , Desenho de Equipamento , Feminino , Humanos , Espectrometria de Massas/métodos , Camundongos , Soroalbumina Bovina/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massa de Íon Secundário/instrumentação , Espectrometria de Massa de Íon Secundário/métodos
3.
J Phys Chem Lett ; 11(20): 8703-8709, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32959663

RESUMO

Singlet fission in tetracene generates two triplet excitons per absorbed photon. If these triplet excitons can be effectively transferred into silicon (Si), then additional photocurrent can be generated from photons above the bandgap of Si. This could alleviate the thermalization loss and increase the efficiency of conventional Si solar cells. Here, we show that a change in the polymorphism of tetracene deposited on Si due to air exposure facilitates triplet transfer from tetracene into Si. Magnetic field-dependent photocurrent measurements confirm that triplet excitons contribute to the photocurrent. The decay of tetracene delayed photoluminescence was used to determine a transfer efficiency of ∼36% into Si. Our study suggests that control over the morphology of tetracene during the deposition will be of great importance to boost the triplet transfer yield further.

4.
Rev Sci Instrum ; 78(5): 053716, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17552834

RESUMO

Mass spectrometry based proteomics is one of the scientific domains in which experiments produce a large amount of data that need special environments to interpret the results. Without the use of suitable tools and strategies, the transformation of the large data sets into information is not easily achievable. Therefore, in the context of the virtual laboratory of enhanced science, software tools are developed to handle mass spectrometry data sets. Using different data processing strategies for visualization, it enables fast mass spectrometric imaging of large surfaces at high-spatial resolution and thus aids in the understanding of various diseases and disorders. This article describes how to optimize the handling and processing of the data sets, including the selection of the most optimal data formats and the use of parallel processing. It also describes the tools and solutions and their application in mass spectrometric imaging strategies, including new measurement principles, image enhancement, and image artifact suppression.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Microscopia Confocal/métodos , Microscopia/métodos , Proteoma/metabolismo , Software , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Interface Usuário-Computador , Gráficos por Computador , Bases de Dados Factuais , Armazenamento e Recuperação da Informação/métodos , Mapeamento de Peptídeos/métodos , Proteoma/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
5.
Sci Rep ; 6: 19566, 2016 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-26786062

RESUMO

One of the important obstacles on the way to application of Si nanocrystals for development of practical devices is their typically low emissivity. In this study we explore the limits of external quantum yield of photoluminescence of solid-state dispersions of Si nanocrystals in SiO2. By making use of a low-temperature hydrogen passivation treatment we demonstrate a maximum emission quantum efficiency of approximately 35%. This is the highest value ever reported for this type of material. By cross-correlating PL lifetime with EQE values, we obtain a comprehensive understanding of the efficiency limiting processes induced by Pb-defects. We establish that the observed record efficiency corresponds to an interface density of Pb-centers of 1.3 × 10(12) cm(12), which is 2 orders of magnitude higher than for the best Si/SiO2 interface. This result implies that Si nanocrystals with up to 100% emission efficiency are feasible.

6.
J Mass Spectrom ; 40(2): 160-8, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15706616

RESUMO

Imaging mass spectrometry provides both chemical information and the spatial distribution of each analyte detected. Here it is demonstrated how imaging mass spectrometry of tissue at subcellular resolution can be achieved by combining the high spatial resolution of secondary ion mass spectrometry (SIMS) with the sample preparation protocols of matrix-assisted laser desorption/ionization (MALDI). Despite mechanistic differences and sampling 10(5) times less material, matrix-enhanced (ME)-SIMS of tissue samples yields similar results to MALDI (up to m/z 2500), in agreement with previous studies on standard compounds. In this regard ME-SIMS represents an attractive alternative to polyatomic primary ions for increasing the molecular ion yield. ME-SIMS of whole organs and thin sections of the cerebral ganglia of Lymnaea stagnalis demonstrate the advantages of ME-SIMS for chemical imaging mass spectrometry. Subcellular distributions of cellular analytes are clearly obtained, and the matrix provides an in situ height map of the tissue, allowing the user to identify rapidly regions prone to topographical artifacts and to deconvolute topographical losses in mass resolution and signal-to-noise ratio.


Assuntos
Química Encefálica , Baratas/citologia , Lymnaea/citologia , Espectrometria de Massa de Íon Secundário/métodos , Animais , Encéfalo/citologia , Colesterol/análise , Baratas/química , Gentisatos , Lymnaea/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Espectrometria de Massa de Íon Secundário/instrumentação , Ácido Trifluoracético
7.
Nat Protoc ; 2(5): 1185-96, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17546014

RESUMO

Imaging mass spectrometry (IMS) allows the direct investigation of both the identity and the spatial distribution of the molecular content directly in tissue sections, single cells and many other biological surfaces. In this protocol, we present the steps required to retrieve the molecular information from tissue sections using matrix-enhanced (ME) and metal-assisted (MetA) secondary ion mass spectrometry (SIMS) as well as matrix-assisted laser desorption/ionization (MALDI) IMS. These techniques require specific sample preparation steps directed at optimal signal intensity with minimal redistribution or modification of the sample analytes. After careful sample preparation, different IMS methods offer a unique discovery tool in, for example, the investigation of (i) drug transport and uptake, (ii) biological processing steps and (iii) biomarker distributions. To extract the relevant information from the huge datasets produced by IMS, new bioinformatics approaches have been developed. The duration of the protocol is highly dependent on sample size and technique used, but on average takes approximately 5 h.


Assuntos
Biologia Computacional/métodos , Diagnóstico por Imagem/métodos , Proteínas/análise , Proteômica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massa de Íon Secundário/métodos , Diagnóstico por Imagem/instrumentação , Proteômica/instrumentação
8.
Rapid Commun Mass Spectrom ; 20(22): 3435-42, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17066367

RESUMO

The combination of microscope mode matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) with protein identification methodology: the molecular scanner, was explored. The molecular scanner approach provides improvement of sensitivity of detection and identification of high-mass proteins in microscope mode IMS. The methodology was tested on protein distributions obtained after separation by sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE). High-quality, high-spatial-resolution ion images were recorded on a TRIFT-II ion microscope after gold coating of the MALDI sample preparation on the poly(vinylidenedifluoride) capture membranes. The sensitivity of the combined method is estimated to be 5 pmol. The minimum amount of sample consumed, needed for identification, was estimated to be better than 100 fmol. Software tools were developed to analyze the spectral data and to generate broad mass range and single molecular component microscope mode ion images and single mass-to-charge ratio microprobe mode images.


Assuntos
Proteínas/análise , Proteínas/química , Análise de Sequência de Proteína/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massa de Íon Secundário/métodos , Animais , Biotecnologia , Bovinos , Galinhas , Eletroforese em Gel de Poliacrilamida , Proteômica/métodos , Coelhos , Espalhamento de Radiação , Sensibilidade e Especificidade , Análise de Sequência de Proteína/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
9.
J Proteome Res ; 4(3): 671-3, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15952713

RESUMO

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS)1 is an established technique for the analysis of biological macromolecules. Its relative insensitivity to pollutants makes MALDI-MS very suitable for the direct analysis of biological samples. As such, it has facilitated great advances in the field of biomolecular imaging mass spectrometry. Traditionally, MALDI-MS imaging is performed in a scanning microprobe methodology.(2-4) However, in a recent study we have demonstrated an alternative methodology; the so-called microscope mode,(5) where the requirement for a highly focused ionization beam is removed. Spatial details from within the desorption area are conserved during the flight of the ions through the mass analyzer, and a magnified ion image is projected onto a 2D-detector. In this paper, we demonstrate how imaging mass spectrometry benefits from the microscope mode approach. For the first time, high-lateral resolution ion images were recorded using infrared MALDI at 2.94 microm wavelength. The ion optical resolution achieved was well below the theoretical limit of (light-) diffraction for the setup used, which is impossible to achieve in the conventional scanning microprobe approach.


Assuntos
Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Raios Infravermelhos , Lasers , Microscopia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
10.
Anal Chem ; 76(18): 5339-44, 2004 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15362890

RESUMO

For the first time macromolecular ion microscope images have been recorded using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Single-shot, mass-resolved images of the spatial distributions of intact peptide and protein ions over an area of 200 microm in diameter were obtained in less than 1 ms at a repetition rate of 12 Hz. The magnifying ion optics of the ion microscope allowed ion images to be obtained with a lateral resolution of 4 microm. These results prove the concept of high-resolution MALDI-MS imaging in microscope mode without the need for a tight laser focus and the accompanying sensitivity losses. The ion microscopy approach offers an improvement of several orders of magnitude in speed of acquisition compared to the conventional (microprobe) approach to MALDI-MS imaging.


Assuntos
Peptídeos/análise , Peptídeos/química , Proteínas/análise , Proteínas/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Processamento de Imagem Assistida por Computador , Sensibilidade e Especificidade
11.
Anal Chem ; 75(10): 2333-41, 2003 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-12918974

RESUMO

Intense intact molecular ion signals have been obtained from phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, and phosphatidyiinositol using matrix-enhanced secondary ion mass spectrometry (ME-SIMS). It was found that the high-mass (m/z >500) regions of the ME-SIMS spectra closely resembled those obtained using matrix-assisted laser desorption/ionization (MALDI). Using high spatial resolution SIMS, a detailed investigation of dried-droplet samples was performed. Based on the detected Na+ and 2,5-DHB matrix signal intensities, different crystal types were distinguished, in addition to different sizes of crystals. Spatially mapping the pseudomolecular and fragment ions of the phospholipids revealed that the nature of the pseudomolecular ions formed, as well as the ratio of intact molecular to fragment ion, was dependent on the type and surface composition of the crystal. The observed chemical bias effects due to crystal heterogeneity and the resulting variation in desorption/ionization efficiency will complicate the interpretation of data obtained from matrix-assisted mass spectrometric (imaging) techniques and is an important factor in the "hot spot" phenomenon frequently encountered in MALDI experiments. In this respect, imaging SIMS was found to be a versatile tool to investigate the effects of the local physicochemical conditions on the detected molecular species.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Cristalização , Peso Molecular , Fosfolipídeos/análise , Fosfolipídeos/química
12.
Anal Chem ; 75(17): 4373-81, 2003 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-14632039

RESUMO

It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, in addition to increasing the yield of intact pseudomolecular ions, the matrix allows the user to semiquantitatively record the topography of a sample. Through mapping the topography-related mass shifts of the matrix (which leads to decreased mass resolution), the analogous mass shifts of higher mass ions can be deconvoluted and higher resolution and greater sensitivity obtained. Furthermore, the semiquantitative topographical map obtained can be compared with any chemical images obtained, allowing the user to quickly ascertain whether local intensity maximums are due to topological features or represent genuine features of interest.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA