1.
Strahlenther Onkol ; 198(5): 484-496, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34888732

RESUMO

PURPOSE: In stereotactic radiosurgery (SRS), prescription isodoses and resulting dose homogeneities vary widely across different platforms and clinical entities. Our goal was to investigate the physical limitations of generating dose distributions with an intended level of homogeneity in robotic SRS. METHODS: Treatment plans for non-isocentric irradiation of 4 spherical phantom targets (volume 0.27-7.70 ml) and 4 clinical targets (volume 0.50-5.70 ml) were calculated using Sequential (phantom) or VOLOTM (clinical) optimizers (Accuray, Sunnyvale, CA, USA). Dose conformity, volume of 12 Gy isodose (V12Gy) as a measure for dose gradient, and treatment time were recorded for different prescribed isodose levels (PILs) and collimator settings. In addition, isocentric irradiation of phantom targets was examined, with dose homogeneity modified by using different collimator sizes. RESULTS: Dose conformity was generally high (nCI ≤ 1.25) and varied little with PIL. For all targets and collimator sets, V12Gy was highest for PIL ≥ 80% and lowest for PIL ≤ 65%. The impact of PIL on V12Gy was highest for isocentric irradiation and lowest for clinical targets (VOLOTM optimization). The variability of V12Gy as a function of collimator selection was significantly higher than that of PIL. V12Gy and treatment time were negatively correlated. Plans utilizing a single collimator with a diameter in the range of 70-80% of the target diameter were fastest, but showed the strongest dependence on PIL. CONCLUSION: Inhomogeneous dose distributions with PIL ≤ 70% can be used to minimize dose to normal tissue. PIL ≥ 90% is associated with a marked and significant increase in off-target dose exposure. Careful selection of collimators during planning is even more important.


Assuntos
Radiocirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Prescrições , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Stereotact Funct Neurosurg ; 96(5): 335-341, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30481772

RESUMO

BACKGROUND: Directional deep brain stimulation (DBS) allows steering the stimulation in an axial direction which offers greater flexibility in programming. However, accurate anatomical visualization of the lead orientation is required for interpreting the observed stimulation effects and to guide programming. OBJECTIVES: In this study we aimed to develop and test an accurate and robust algorithm for determining the orientation of segmented electrodes based on standard postoperative CT imaging used in DBS. METHODS: Orientation angles of directional leads (CartesiaTM; Boston Scientific, Marlborough, MA, USA) were determined using CT imaging. Therefore, a sequential algorithm was developed that quantitatively compares the similarity of the observed CT artifacts with calculated artifact patterns based on the lead's orientation marker and a geometric model of the segmented electrodes. Measurements of seven ground truth phantoms and three leads with 60 different configurations of lead implantation and orientation angles were analyzed for validation. RESULTS: The accuracy of the determined electrode orientation angles was -0.6 ± 1.5° (range: -5.4 to 4.2°). This accuracy proved to be sufficiently high to resolve even subtle differences between individual leads. CONCLUSIONS: The presented algorithm is user independent and provides highly accurate results for the orientation of the segmented electrodes for all angular constellations that typically occur in clinical cases.


Assuntos
Algoritmos , Estimulação Encefálica Profunda/instrumentação , Eletrodos Implantados , Tomografia Computadorizada por Raios X/instrumentação , Artefatos , Estimulação Encefálica Profunda/métodos , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
3.
Strahlenther Onkol ; 191(6): 470-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25416146

RESUMO

BACKGROUND AND PURPOSE: Stereotactic radiosurgery with an adapted linear accelerator (linac-SRS) is an established therapy option for brain metastases, benign brain tumors, and arteriovenous malformations. We intended to investigate whether the dosimetric quality of treatment plans achieved with a CyberKnife (CK) is at least equivalent to that for linac-SRS with circular or micromultileaf collimators (microMLC). PATIENTS AND METHODS: A random sample of 16 patients with 23 target volumes, previously treated with linac-SRS, was replanned with CK. Planning constraints were identical dose prescription and clinical applicability. In all cases uniform optimization scripts and inverse planning objectives were used. Plans were compared with respect to coverage, minimal dose within target volume, conformity index, and volume of brain tissue irradiated with ≥ 10 Gy. RESULTS: Generating the CK plan was unproblematic with simple optimization scripts in all cases. With the CK plans, coverage, minimal target volume dosage, and conformity index were significantly better, while no significant improvement could be shown regarding the 10 Gy volume. Multiobjective comparison for the irradiated target volumes was superior in the CK plan in 20 out of 23 cases and equivalent in 3 out of 23 cases. Multiobjective comparison for the treated patients was superior in the CK plan in all 16 cases. CONCLUSION: The results clearly demonstrate the superiority of the irradiation plan for CK compared to classical linac-SRS with circular collimators and microMLC. In particular, the average minimal target volume dose per patient, increased by 1.9 Gy, and at the same time a 14% better conformation index seems to be an improvement with clinical relevance.


Assuntos
Neoplasias Encefálicas/cirurgia , Aceleradores de Partículas/instrumentação , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Robótica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Irradiação Craniana , Humanos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
4.
Z Med Phys ; 2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36717311

RESUMO

PURPOSE: In robotic stereotactic radiosurgery (SRS), optimal selection of collimators from a set of fixed cones must be determined manually by trial and error. A unique and uniformly scaled metric to characterize plan quality could help identify Pareto-efficient treatment plans. METHODS: The concept of dose-area product (DAP) was used to define a measure (DAPratio) of the targeting efficiency of a set of beams by relating the integral DAP of the beams to the mean dose achieved in the target volume. In a retrospective study of five clinical cases of brain metastases with representative target volumes (range: 0.5-5.68 ml) and 121 treatment plans with all possible collimator choices, the DAPratio was determined along with other plan metrics (conformity index CI, gradient index R50%, treatment time, total number of monitor units TotalMU, radiotoxicity index f12, and energy efficiency index η50%), and the respective Spearman's rank correlation coefficients were calculated. The ability of DAPratio to determine Pareto efficiency for collimator selection at DAPratio < 1 and DAPratio < 0.9 was tested using scatter plots. RESULTS: The DAPratio for all plans was on average 0.95 ±â€¯0.13 (range: 0.61-1.31). Only the variance of the DAPratio was strongly dependent on the number of collimators. For each target, there was a strong or very strong correlation of DAPratio with all other metrics of plan quality. Only for R50% and η50% was there a moderate correlation with DAPratio for the plans of all targets combined, as R50% and η50% strongly depended on target size. Optimal treatment plans with CI, R50%, f12, and η50% close to 1 were clearly associated with DAPratio < 1, and plans with DAPratio < 0.9 were even superior, but at the cost of longer treatment times and higher total monitor units. CONCLUSIONS: The newly defined DAPratio has been demonstrated to be a metric that characterizes the target efficiency of a set of beams in robotic SRS in one single and uniformly scaled number. A DAPratio < 1 indicates Pareto efficiency. The trade-off between plan quality on the one hand and short treatment time or low total monitor units on the other hand is also represented by DAPratio.

5.
J Neurooncol ; 109(2): 365-74, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22717668

RESUMO

This paper summarizes outcomes of a single-center study of intracavitary brachytherapy (IBT) with stereotactically applied phosphorus-32 ((32)P) colloid for treatment of cystic craniopharyngiomas. We assessed its efficacy and safety, on the basis of clinical and radiological outcomes in one of the largest reported patient series. Between 1992 and 2011, 53 patients were treated with IBT, 14 without previous treatment and 39 who had previously been treated for recurrent cysts. Intervention was performed by applying 200 Gy to the internal cyst wall (median volume 6.1 ml). Median clinical and radiological follow-up were 60.2 and 53.0 months, respectively. Actuarial tumor cyst control was 86.0 ± 5.3 % at 12, 24, and 60 months. Actuarial out-of-field control (development of new cysts or progression of solid tumor parts) was 90.9 ± 4.3, 84.0 ± 5.6, and 54.5 ± 8.8 % after 12, 24, and 60 months, respectively. Corresponding actuarial overall progression-free survival was 79.4 ± 6.1, 72.4 ± 6.8, and 45.6 ± 8.7 % at 12, 24, and 60 months, respectively. Visual function improved for 12 patients (23.5 %), remained unchanged for 34 patients (66.7 %), and worsened for five patients (9.8 %), correlating with tumor progression in each case. Endocrinological deterioration occurred for ten patients (19.6 %); for nine patients this was a result of tumor progression or after tumor resection and for one it was attributed to irradiation. Within six months of IBT seven patients (13.7 %) experienced transient neurological deficits and two patients (3.9 %) deteriorated permanently (hemiparesis and third nerve palsy). Stereotactically applied (32)P is highly efficacious for control of cystic components of craniopharyngiomas and is associated with a low risk of permanent morbidity. The procedure does not, however affect the development of new cysts or the progression of solid tumor parts.


Assuntos
Braquiterapia/métodos , Craniofaringioma/tratamento farmacológico , Neoplasias Hipofisárias/tratamento farmacológico , Adolescente , Hormônio Adrenocorticotrópico/metabolismo , Adulto , Idoso , Criança , Coloides/uso terapêutico , Intervalo Livre de Doença , Feminino , Hormônio Foliculoestimulante , Seguimentos , Hormônio do Crescimento , Humanos , Hormônio Luteinizante , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Isótopos de Fósforo/uso terapêutico , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento , Adulto Jovem
6.
Front Neurorobot ; 16: 762317, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35515711

RESUMO

Background: The development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell stereotactic frame by reducing clinical and procedural factors to a minimum. Methods: To precisely compare mechanical accuracy, a stereotactic system was chosen as reference for both methods. A thin layer CT scan with an acrylic phantom fixed to the frame and a localizer enabling the software to recognize the coordinate system was performed. For each of the five phantom targets, two different trajectories were planned, resulting in 10 trajectories. A series of five repetitions was performed, each time based on a new CT scan. Hence, 50 trajectories were analyzed for each method. X-rays of the final cannula position were fused with the planning data. The coordinates of the target point and the endpoint of the robot- or frame-guided probe were visually determined using the robotic software. The target point error (TPE) was calculated applying the Euclidian distance. The depth deviation along the trajectory and the lateral deviation were separately calculated. Results: Robotics was significantly more accurate, with an arithmetic TPE mean of 0.53 mm (95% CI 0.41-0.55 mm) compared to 0.72 mm (95% CI 0.63-0.8 mm) in stereotaxy (p < 0.05). In robotics, the mean depth deviation along the trajectory was -0.22 mm (95% CI -0.25 to -0.14 mm). The mean lateral deviation was 0.43 mm (95% CI 0.32-0.49 mm). In frame-based stereotaxy, the mean depth deviation amounted to -0.20 mm (95% CI -0.26 to -0.14 mm), the mean lateral deviation to 0.65 mm (95% CI 0.55-0.74 mm). Conclusion: Both the robotic and frame-based approach proved accurate. The robotic procedure showed significantly higher accuracy. For both methods, procedural factors occurring during surgery might have a more relevant impact on overall accuracy.

8.
Radiat Oncol ; 12(1): 136, 2017 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-28818094

RESUMO

BACKGROUND: As irradiated brain volume at 12 Gy (V12) is a predictor for radionecrosis, the purpose of the study was to develop a model for Cyberknife (CK) plans that is able to predict the lowest achievable V12 at a given tumor size and prescription dose (PD), and to suggest a new quality index regarding V12 for optimizing the treatment planning of brain metastases. METHOD: In our model V12 was approximated as a spherical shell around the tumor volume. The radial distance between tumor surface and the 12 Gy isodose line was calculated using an approximation of the mean dose gradient in that area. Assuming a radially symmetrical irradiation from the upper half space, the dose distribution is given by the superposition of single fields. The dose profiles of a single field were derived by the measured off-center ratios (OCR) of the CK system. Using the calculated gradients of the sum dose profiles, minimal-V12 was estimated for different tumor sizes. The model calculation was tested using a phantom dataset and retrospectively applied on clinical cases. RESULTS: Our model allows the prediction of a best-case scenario for V12 at a given tumor size and PD which was confirmed by the results of the isocentric phantom plans. The results of the non-isocentric phantom plans showed that an optimization of coverage caused an increase in V12. This was in accordance with the results of the retrospective analysis. V12 s of the clinical cases were on average twice that of the predicted model calculation. A good agreement was achieved for plans with an optimal conformity index (nCI). Re-planning of cases with high V12 showed that lower values could be reached by selecting smaller collimators and by allowing a larger number of total MU and more MU per beam. CONCLUSIONS: V12 is a main parameter for assessing plan quality in terms of radiotoxicity. The index f12 defined as the ratio of V12 from the actual plan with the evaluated V12 from our model describes the conformity of an optimally possible V12 and thus can be used as a new quality index for optimizing treatment plans.


Assuntos
Neoplasias Encefálicas/radioterapia , Metástase Neoplásica/radioterapia , Radiometria/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Modelos Teóricos , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Procedimentos Cirúrgicos Robóticos/métodos
9.
Med Phys ; 44(9): 4463-4473, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28639387

RESUMO

PURPOSE: Orientating the angle of directional leads for deep brain stimulation (DBS) in an axial plane introduces a new degree of freedom that is indicated by embedded anisotropic directional markers. Our aim was to develop algorithms to determine lead orientation angles from computed tomography (CT) and stereotactic x-ray imaging using standard clinical protocols, and subsequently assess the accuracy of both methods. METHODS: In CT the anisotropic marker artifact was taken as a signature of the lead orientation angle and analyzed using discrete Fourier transform of circular intensity profiles. The orientation angle was determined from phase angles at a frequency 2/360° and corrected for aberrations at oblique leads. In x-ray imaging, frontal and lateral images were registered to stereotactic space and sub-images containing directional markers were extracted. These images were compared with projection images of an identically located virtual marker at different orientation angles. A similarity index was calculated and used to determine the lead orientation angle. Both methods were tested using epoxy phantoms containing directional leads (Cartesia™, Boston Scientific, Marlborough, USA) with known orientation. Anthropomorphic phantoms were used to compare both methods for DBS cases. RESULTS: Mean deviation between CT and x-ray was 1.5° ± 3.6° (range: -2.3° to 7.9°) for epoxy phantoms and 3.6° ± 7.1° (range: -5.6° to 14.6°) for anthropomorphic phantoms. After correction for imperfections in the epoxy phantoms, the mean deviation from ground truth was 0.0° ± 5.0° (range: -12° to 14°) for x-ray. For CT the results depended on the polar angle of the lead in the scanner. Mean deviation was -0.3° ± 1.9° (range: -4.6° to 6.6°) or 1.6° ± 8.9° (range: -23° to 34°) for polar angles ≤ 40° or > 40°. CONCLUSIONS: The results show that both imaging modalities can be used to determine lead orientation angles with high accuracy. CT is superior to x-ray imaging, but oblique leads (polar angle > 40°) show limited precision due to the current design of the directional marker.


Assuntos
Estimulação Encefálica Profunda , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X , Boston , Humanos , Chumbo , Imagens de Fantasmas , Raios X
10.
Radiother Oncol ; 81(1): 25-32, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17005278

RESUMO

OBJECTIVE: Determination of the impact of inaccuracies in the determination and setup of the target point in stereotactic radiosurgery (SRS) on the expectable complication and control probabilities. METHODS: Two randomized samples of patients with arteriovenous malformation (AVM) (n=20) and with brain metastases (n=20) treated with SRS were formed, and the probability for complete obliteration (COP) or complete remission (CRP), the size of the 10 Gy-volume in the brain tissue (VOI10), and the probability for radiation necrosis (NTCP) were calculated. The dose-effect relations for COP and CRP were fitted to clinical data. Target point deviations were simulated through random vectors and the resulting probabilities and volumes were calculated and compared with the values of the treatment plan. RESULTS: The decrease of the relative value of the control probabilities at 1mm target point deviation was up to 4% for AVMs and up to 10% for metastases. At 2 mm the median decrease was 5% for AVMs and 9% for metastases. The value for the target point deviation, at which COP and CRP decreased about 0.05 in 90% of the cases, was 1.3 mm. The increase of NTCP was maximally 0.0025 per mm target point deviation for AVMs and 0.0035/mm for metastases. The maximal increase of VOI10 was 0.7 cm(3)/mm target point deviation in both patient groups. CONCLUSIONS: The upper limit for tolerable target point deviations is at 1.3mm. If this value cannot be achieved during the system test, a supplementary safety margin should be applied for the definition of the target volume. A better accuracy level is desirable, in order to ensure optimal chances for the success of the treatment. The target point precision is less important for the minimization of the probability of radiation necroses.


Assuntos
Neoplasias Encefálicas/cirurgia , Malformações Arteriovenosas Intracranianas/cirurgia , Erros Médicos/efeitos adversos , Radiocirurgia/efeitos adversos , Encéfalo/patologia , Neoplasias Encefálicas/secundário , Relação Dose-Resposta à Radiação , Humanos , Necrose/etiologia , Probabilidade , Indução de Remissão , Estudos Retrospectivos , Resultado do Tratamento