Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Wien Med Wochenschr ; 174(5-6): 123-125, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37079176

RESUMO

Acute bilateral vision loss (ABVL) is a rare and challenging diagnostic issue that is most often caused by a neurological disorder. Since it can be the presenting symptom of potentially life-threatening diseases, priority should be given to excluding such diagnoses. Special caution is required if ABVL symptoms result after an intracranial intervention. This article reports on a diagnostic approach for a patient suffering from ABVL due to vitreous hemorrhage related to a subarachnoid hemorrhage (SAH) after endovascular intracranial aneurysm treatment. This case study highlights the importance of imaging interpretation and its consequences.


Assuntos
Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/cirurgia , Hemorragia Vítrea/complicações , Hemorragia Vítrea/diagnóstico
2.
Neurol Sci ; 42(6): 2391-2396, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33052575

RESUMO

BACKGROUND: Tandem occlusions can complicate medical and endovascular stroke treatment. To identify these occlusions, computed tomography angiography (CTA) represents the best imaging modality. However, CTA is still not initially performed in some patients not admitted directly to stroke centers. Early identification of an additional occlusion of the proximal extracranial internal carotid artery may improve the best suitable treatment strategy. The purpose of this study was to find a valuable threshold of thrombus attenuation in a non-contrast head CT (NCCT) scan to facilitate a safe diagnosis of tandem occlusions. MATERIALS AND METHODS: Consecutive patients with acute middle cerebral artery (MCA) occlusions who underwent endovascular treatment were identified from our registry of neuroendovascular interventions. Thrombus attenuations of the affected MCA and contralateral vessel were measured by NCCT. To compare individual baseline blood attenuations, the difference between the thrombus attenuation and the contralateral MCA attenuation (referred to as ΔTM) was calculated. RESULTS: Three hundred and twenty-five patients were included. There was a highly significant difference between mean thrombus attenuation with isolated MCA occlusion and additional extracranial internal carotid artery (ICA) occlusion (49.9 ± 8 vs. 56.2 ± 10 Hounsfield units (HU); P < 0.001). The area under the receiver operating characteristic curve of ΔTM was 0.72. The optimal threshold value was 13.5 HU, with a sensitivity of 67.5% and a specificity of 68.6%. CONCLUSION: Despite a significant difference in thrombus attenuation in MCA occlusions with an additional extracranial ICA occlusion compared with isolated MCA occlusions, a relevant threshold of thrombus attenuation was not found.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Artéria Carótida Interna/diagnóstico por imagem , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Infarto da Artéria Cerebral Média/terapia , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Resultado do Tratamento
3.
Stroke ; 51(10): 2895-2900, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32967576

RESUMO

BACKGROUND AND PURPOSE: This randomized study aimed to evaluate whether the use of a stroke clock demanding active feedback from the stroke physician accelerates acute stroke management. METHODS: For this randomized controlled study, a large-display alarm clock was installed in the computed tomography room, where admission, diagnostic work-up, and intravenous thrombolysis occurred. Alarms were set at the following target times after admission: (1) 15 minutes (neurological examination completed); (2) 25 minutes (computed tomography scanning and international normalized ratio determination by point-of-care laboratory completed); and (3) 30 minutes (intravenous thrombolysis started). The responsible stroke physician had to actively provide feedback by pressing a buzzer button. The alarm could be avoided by pressing the button before time out. Times to therapy decision (primary end point, defined as the end of all diagnostic work-up required for decision for or against recanalizing treatment), neurological examination, imaging, point-of-care laboratory, needle, and groin puncture were assessed by a neutral observer. Functional outcome (modified Rankin Scale) was assessed at day 90. RESULTS: Of 107 participants, 51 stroke clock patients exhibited better stroke-management metrics than 56 control patients. Times from door to (1) end of all indicated diagnostic work-up (treatment decision time; 16.73 versus 26.00 minutes, P<0.001), (2) end of neurological examination (7.28 versus 10.00 minutes, P<0.001), (3) end of computed tomography (11.17 versus 14.00 minutes, P=0.002), (4) end of computed tomography angiography (14.00 versus 17.17 minutes, P=0.001), (5) end of point-of-care laboratory testing (12.14 versus 20.00 minutes, P<0.001), and (6) needle times (18.83 versus 47.00 minutes, P=0.016) were improved. In contrast, door-to-groin puncture times and functional outcomes at day 90 were not significantly different. CONCLUSIONS: This study showed that the use of a stroke clock demanding active feedback significantly improves acute stroke-management metrics and, thus, represents a potential low-cost strategy for streamlining time-sensitive stroke treatment.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/tratamento farmacológico , Terapia Trombolítica/métodos , Ativador de Plasminogênio Tecidual/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Gerenciamento Clínico , Retroalimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia Computadorizada por Raios X
4.
Neurol Sci ; 41(6): 1547-1555, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31974796

RESUMO

PURPOSE: Mechanical thrombectomy (MT) is an effective treatment for patients suffering from acute ischemic stroke. However, recanalization fails in about 16.5% of interventions. We report our experience with unsuccessful MT and analyze technical reasons plus patient-related parameters for failure. METHODS: Five hundred ninety-six patients with acute ischemic stroke in the anterior circulation and intention to perform MT with an aspiration catheter and/or stent retriever were analyzed. Failure was defined as 0, 1, or 2a on the mTICI scale. Patients with failing MT were analyzed for interventional progress and compared to patients with successful intervention, whereby parameters included demographics, medical history, stroke presentation, and treatment. RESULTS: One hundred of the 596 (16.8%) interventions failed. In 20 cases, thrombus could not be accessed or passed with the device. Peripheral arterial occlusive disease is common in those patients. In 80 patients, true stent retriever failure occurred. In this group, coagulation disorders are associated with poor results, whereas atrial fibrillation is associated with success. The administration of intravenous thrombolysis and intake of nitric oxide donors are associated with recanalization success. Intervention duration was significantly longer in the failing group. CONCLUSION: In 20% of failing MT, thrombus cannot be reached/passed. Direct carotid puncture or surgical arterial access could be considered in these cases. In 80% of failing interventions, thrombus can be passed with the device, but the occluded vessel cannot be recanalized. Rescue techniques can be an option. Development of new devices and techniques is necessary to improve recanalization rates. Assessment of pre-existing illness could sensitize for occurring complications.


Assuntos
Doenças das Artérias Carótidas/terapia , Infarto da Artéria Cerebral Média/terapia , AVC Isquêmico/terapia , Trombólise Mecânica , Avaliação de Resultados em Cuidados de Saúde , Avaliação de Processos em Cuidados de Saúde , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Humanos , Masculino , Trombólise Mecânica/estatística & dados numéricos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Avaliação de Processos em Cuidados de Saúde/estatística & dados numéricos , Estudos Retrospectivos , Stents/estatística & dados numéricos , Terapia Trombolítica/estatística & dados numéricos , Falha de Tratamento
5.
J Mater Sci Mater Med ; 31(12): 131, 2020 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-33270156

RESUMO

This study aimed to investigate in vivo two stent technologies, with particular emphasis on thrombogenicity and inflammatory vessel remodeling processes. The micro-stents tested in this study were developed for intracranial aneurysm treatment. In our study twelve, New Zealand white rabbits were divided into two groups: 18 laser-cut stents (LCS) and 18 braided stents (BS) were impanated without admiration of antiplatelet medication. Three stents were implanted into each animal in the common carotid artery, subclavian artery, and abdominal aorta. Digital subtraction angiography was performed before and after stent implantation and at follow-up for the visualization of occurring In-stent thromboembolism or stenosis. The Stents were explanted for histopathological examination at two different timepoints, after 3 and 28 days. Angiographically neither in-stent thrombosis nor stenosis for both groups was seen. There was a progressive increase in the vessel diameter, which was more pronounced for BS than for LCS. We detected a higher number of thrombi adherent to the foreign material on day 3 for BS. On day 3, the neointima was absent, whereas the complete formation observed was on day 28. There was no significant difference between both groups regarding the thickness of the neointima. The in vivo model of our study enabled the evaluation of blood and vessel reactions for two different stent technologies. Differences in vessel dimension and tissue around the stents were observed on day 28. Histological analysis on day 3 enabled the assessment of thrombotic reactions, representing an important complementary result in long-term studies.


Assuntos
Prótese Vascular , Aneurisma Intracraniano/fisiopatologia , Stents Metálicos Autoexpansíveis , Stents , Angiografia , Animais , Aorta/fisiopatologia , Aorta Abdominal , Artéria Carótida Primitiva , Circulação Cerebrovascular , Constrição Patológica , Lasers , Teste de Materiais , Modelos Animais , Neointima , Inibidores da Agregação Plaquetária/farmacologia , Desenho de Prótese , Coelhos , Artéria Subclávia , Trombose
6.
Radiologe ; 60(4): 317-320, 2020 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-32152651

RESUMO

The development of microstents for aneurysm treatment has greatly expanded endovascular aneurysm therapy. Due to the increased amount of foreign material, the use of such stents is associated with an increased risk of thrombus formation and therewith the associated risk of ischemic stroke. For this reason, various surface coatings have recently been developed. The primary aim of these coatings is to reduce the foreign matter-mediated platelet adhesion to the stent surfaces. The potential reduction of dual antiplatelet therapy when using coated stents was recently discussed. But currently, no neurointerventional guidelines or recommendations endorse the stent implantation under single antiplatelet therapy. This article describes the different coatings in the field of neurointervention and their mode of action.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Stents , Humanos , Inibidores da Agregação Plaquetária
7.
Radiologe ; 60(12): 1172-1176, 2020 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-32821966

RESUMO

BACKGROUND: The therapy strategy of patients with acute stroke of the middle cerebral artery (MCA) is influenced by the location of the occlusion. The purpose of this study was to analyze the clinical outcome in patients with acute ischemic MCA occlusion according to the location of occlusion who underwent endovascular treatment (EVT). METHODS: A total of 54 patients (age 73 ± 15 years; 59% female) with acute ACM occlusion treated with EVT were included. In coronary reformatted CT angiography images, the distance to the thrombus (DT), i.e. the distance from the carotid T to the beginning of the thrombus, was measured. Correlations between DT, clinical symptoms, and clinical outcome of patients who underwent EVT were analyzed. RESULTS: DT correlated with clinical symptoms measured by the National Institutes of Health Stroke Scale (NIHSS; p = 0.017; R = -0.324) at baseline. DT also correlated with the modified Rankin scale after 90 days (90-day mRS; p = 0.014; R = -0.333). DT was a predictor for a good clinical outcome (mRS after 90 days) after EVT; odds ratio 1.113 (P = 0.02; 95% confidence interval [CI] 1.017-1.219). A DT >10 mm correlated significantly (p = 0.036) with a good clinical outcome (90-day mRS ≤2). CONCLUSION: DT correlates with the clinical symptoms of patients with acute MCA occlusion. In addition, DT is an independent predictor of the clinical outcome of patients suffering from acute stroke due to MCA occlusion.


Assuntos
Procedimentos Endovasculares , Infarto da Artéria Cerebral Média , Acidente Vascular Cerebral , Trombose , Angiografia Cerebral , Feminino , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Infarto da Artéria Cerebral Média/tratamento farmacológico , Masculino , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Terapia Trombolítica , Trombose/diagnóstico por imagem , Resultado do Tratamento
8.
Stroke ; 48(8): 2171-2175, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28679854

RESUMO

BACKGROUND AND PURPOSE: A new generation of carotid artery stents that uses a second micromesh layer to reduce embolic events during carotid artery stenting has recently been introduced. The purpose of this study was to compare acute occlusion rates of these new dual-layer stents with those of single-layer stents in the setting of emergency carotid artery stenting with intracranial mechanical thrombectomy in acute ischemic stroke. METHODS: Consecutive patients with acute tandem (intra- and extracranial) lesions of the anterior circulation who were endovascularly treated at our institution were identified from our registry of neuroendovascular interventions. Clinical, angiographic, and neuroimaging data were analyzed. End points included acute occlusions of the carotid stents (within 72 hours after stenting) and symptomatic intracerebral hemorrhage. RESULTS: Forty-seven patients were included. Dual-layer stents (n=20) had a significantly higher rate of acute occlusions than single-layer stents (n=27; 45% versus 3.7%; P=0.001; odds ratio, 21.3; 95% confidence interval, 2.4-188.4). There were no significant differences in the rates of patients who had any antiplatelet or dual antiplatelet medication before admission, in the rates of postinterventional symptomatic intracerebral hemorrhage, the mean National Institutes of Health Stroke Scale scores at admission, or the modified Rankin Scale scores at discharge. CONCLUSIONS: The recently introduced dual-layer stents have a higher risk of acute occlusion compared with single-layer stents in the treatment of acute stroke.


Assuntos
Isquemia Encefálica/cirurgia , Estenose das Carótidas/diagnóstico , Tratamento de Emergência/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Stents/efeitos adversos , Acidente Vascular Cerebral/cirurgia , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico , Estenose das Carótidas/etiologia , Tratamento de Emergência/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico , Trombectomia/efeitos adversos , Trombectomia/métodos , Resultado do Tratamento
9.
Wien Med Wochenschr ; 167(11-12): 282-284, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28755020

RESUMO

Spinal perimedullary arteriovenous fistulas (PMAVFs) are rare entities among vascular malformations of the spinal cord. Due to progressive myelopathy, spastic paresis, sensory disturbance, and bowl and bladder dysfunction can be the presenting symptoms. Cervical spinal arteriovenous fistulas (AVFs) are even rarer. These lesions differ from the ones in the thoracolumbar region and have an even wider mode of presentation. We report on a 9-year-old boy with a cervical PMAVF manifesting with headache and vertigo.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Cefaleia/etiologia , Medula Espinal/irrigação sanguínea , Vertigem/etiologia , Angiografia Digital , Malformações Arteriovenosas/terapia , Angiografia Cerebral , Criança , Embolização Terapêutica , Seguimentos , Cefaleia/terapia , Humanos , Hemorragias Intracranianas/diagnóstico por imagem , Hemorragias Intracranianas/terapia , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Exame Neurológico , Medula Espinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Vertigem/terapia
10.
Neuroradiology ; 58(10): 987-996, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27457491

RESUMO

INTRODUCTION: Flow diverters are increasingly being used to treat intracranial aneurysms. This study evaluates occurring complications of flow-diverting devices in the treatment of experimental aneurysms, involving the use of micro-CT and small animal MRI at 9.4 T, in correlation to angiographic and histological findings. METHODS: We previously published two preclinical studies, in which we assessed two different flow diverters in the treatment of elastase-induced aneurysms. Devices have been implanted across the aneurysm neck as well as in the abdominal aorta. From these studies, a total of 65 devices (prototype FD (n = 30) and Derivo embolization device (n = 35)) additionally underwent micro-CT and MRI after angiographic follow-up and before being histologically examined. RESULTS: The different architectures of both devices were precisely comparable due to high-resolution micro-CT imaging. Micro-CT revealed wire fractures in nine cases (30 %) only with the prototype FD. In three cases (10 %), severe wire fractures correlated with an in-stent stenosis due to intimal hyperplasia. Other complications, like distal stent occlusions and post-stent stenosis, were seen in both groups and verified with both imaging techniques. Osseous metaplasia were correlated to calcifications seen with micro-CT. MRI enabled visualization of the position of the implanted devices relative to the aneurysm and revealed incomplete aneurysm neck coverage with the prototype FD in two cases (6.7 %). CONCLUSION: Micro-CT and 9.4-T MRI are valid to discover and understand occurring complications of flow diverters in the preclinical phase and can serve as evaluation tools to minimize complication rates of endovascular devices in the future.


Assuntos
Revascularização Cerebral/efeitos adversos , Revascularização Cerebral/instrumentação , Oclusão de Enxerto Vascular/etiologia , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética/métodos , Microtomografia por Raio-X/métodos , Animais , Angiografia Cerebral/métodos , Revascularização Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Aneurisma Intracraniano/induzido quimicamente , Elastase Pancreática , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
13.
Neuroradiology ; 56(2): 129-37, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24496551

RESUMO

INTRODUCTION: In this study, we analyzed angiographic and histologic aneurysm occlusion of a newly designed flow diverting device. Visibility and flexibility, as well as occlusions of side branches and neointimal proliferation were also evaluated. METHODS: Aneurysms were induced in 18 New Zealand white rabbits and treated with a braided, "closed-loop-designed" device of nitinol. Additional devices were implanted in the abdominal aorta to cover the origin of branch arteries.Angiographic follow-ups were performed immediately after placement of the device, after 3 months (n=9) and 6 months(n =9). The status of aneurysm occlusion (using a five-point scale) and the patency of branch arteries were assessed. RESULTS: Aneurysm occlusion rates were noted as grade 0 in 2 (11 %), grade I in 1 (6 %), grade II in 1 (6 %), grade III in 9(50 %), and grade IV in 5 (28 %) of 18 aneurysms, respectively, indicating a complete or near-complete occlusion of 78 % under double antiplatelet therapy. Aneurysm occlusion was significantly higher at 6 months follow-up (P =0.025). Radiopaque markers provided excellent visibility. Limited device flexibility led to incomplete aneurysm neck coverage and grade 0 occlusion rates in two cases. Distal device occlusions were found in three cases, most likely due to an extremely undersized vessel diameter in the subclavian artery.No case of branch artery occlusion was seen. Intimal proliferation and diameter stenosis were moderate. CONCLUSION: The tested flow diverter achieved near-complete and complete aneurysm occlusion under double antiplatelet therapy of elastase-induced aneurysms in 78 %, while preserving branch arteries.


Assuntos
Prótese Vascular , Revascularização Cerebral/instrumentação , Modelos Animais de Doenças , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/cirurgia , Stents , Animais , Revascularização Cerebral/métodos , Análise de Falha de Equipamento , Feminino , Humanos , Aneurisma Intracraniano/induzido quimicamente , Angiografia por Ressonância Magnética/métodos , Elastase Pancreática , Desenho de Prótese , Coelhos , Resultado do Tratamento
14.
Arch Toxicol ; 88(1): 89-96, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23877120

RESUMO

Darbepoetin (DPO), an erythropoietin (EPO) derivative, was licensed in 2002 to treat patients with solid tumors suffering from chemotherapy-dependent anemia, although various tumors express EPO to improve vascularization, thus favoring tumor growth and spreading. Therefore, we wanted to investigate direct effects of DPO on the liver tumor cell lines HepG2, SkHep1, Huh-7, AKN1, HCC-T and HCC-M, as well as on primary human hepatocytes (hHeps). DPO (0-40 ng/ml) did not affect viability of hHeps, HepG2, SkHep1, AKN1, HCC-T and HCC-M cells, as determined by Resazurin conversion. However, Huh-7 cells' viability dose-dependently decreased from 5 ng/ml DPO on. Lack of LDH release into culture medium and negative DNA laddering excluded apoptosis or necrosis as the cause for the reduced Resazurin conversion. In Huh-7 cells, DPO increased the expression of p53. Interestingly, Huh-7 cells showed the highest basal TGF-ß1 expression as compared to the other cell lines. Upon inhibition of TGF-ß1 signaling, DPO no longer reduced viability in Huh-7 cells. On the contrary, co-incubation with TGF-ß1 made the other cell lines responsive to DPO. Summarizing our data, we show that DPO reduces the growth of Huh-7 cells by up-regulation of the tumor-suppressor gene p53. This mechanism seems to be dependent on a strong TGF-ß expression and corresponding signaling in these cells, as other cell lines became responsive to DPO with TGF-ß1 supplementation. The knowledge of this mechanism offers great perspectives for the understanding and treatment of solid liver tumors.


Assuntos
Eritropoetina/análogos & derivados , Neoplasias Hepáticas/tratamento farmacológico , Fator de Crescimento Transformador beta/metabolismo , Apoptose/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Darbepoetina alfa , Relação Dose-Resposta a Droga , Eritropoetina/farmacologia , Hepatócitos/efeitos dos fármacos , Humanos , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/patologia , Fosforilação/efeitos dos fármacos , Transdução de Sinais/efeitos dos fármacos , Fator de Crescimento Transformador beta1/farmacologia , Proteína Supressora de Tumor p53/metabolismo , Regulação para Cima/efeitos dos fármacos
15.
Radiologie (Heidelb) ; 64(3): 215-218, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38321288

RESUMO

Endocrine orbitopathy (EO), also known as Graves' orbitopathy or thyroid-associated orbitopathy, is a self-limiting, immunologically induced co-reaction of the retrobulbar tissue of the eye triggered by an autoimmune disease of the thyroid gland. It is particularly associated with Graves' disease and is its most common extrathyroidal manifestation. In addition to typical anamnestic data, characteristic local findings and laboratory changes in immunothyroidism, orbital imaging plays a central role in the diagnosis and management of this disease. This review article provides comprehensive insight into various imaging modalities used to assess morphologic changes associated with EO. A detailed presentation of imaging findings provides a better understanding of orbital physiology.


Assuntos
Doenças Autoimunes , Doença de Graves , Oftalmopatia de Graves , Humanos , Oftalmopatia de Graves/diagnóstico , Oftalmopatia de Graves/terapia , Doença de Graves/diagnóstico , Órbita/diagnóstico por imagem
16.
Neuroradiol J ; 37(1): 31-38, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37586720

RESUMO

BACKGROUND AND PURPOSE: The results of the preclinical study of a novel polymer coil in treatment of elastase induced aneurysms will be presented in this paper. MATERIAL AND METHODS: We induced 16 aneurysms in 16 New Zealand white rabbits at the origin of the right common carotid artery at the brachiocephalic trunk. Newly developed polymer coils in both groups for six aneurysms each and platinum coils for two aneurysms each were used. Control angiographies followed in both groups immediately after coiling as well as in the first eight animals 30 days after intervention (30 days group) and in the other eight animals 90 days after (90 days group). An explanation and histological evaluation of the treated aneurysms followed. RESULTS: The 12 animals in which the aneurysms were treated with polymer coils showed a complete occlusion (grade IV) in only 6 out of 12 aneurysms (50%), an almost complete occlusion (grade III) in 5 out of 12 (42%) and an incomplete occlusion in the treatment of one aneurysm (8%). Histologically, we observed a significantly more pronounced inflammatory response and neoangiogenesis in aneurysms treated with polymer coils only in the 30 days group. CONCLUSION: Most difficulties and concerns with the polymer coils were related to the flexibility and detachment behaviour. Therefore, and due to the technical challenges of delivery, the novel polymer coil cannot be considered an alternative to the current platinum coils.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Coelhos , Animais , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/patologia , Platina , Polímeros , Embolização Terapêutica/métodos , Resultado do Tratamento
17.
J Neurointerv Surg ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760168

RESUMO

BACKGROUND: Neurointerventional devices, particularly laser-cut thin-strut stents made of self-expanding nickel-titanium alloy, are increasingly utilized for endovascular applications in intracranial arteries and dural venous sinuses. Preventing thrombosis and stroke necessitates systemic anticoagulant and antiplatelet therapies with the risk of bleeding complications. Antithrombotic coatings present a promising solution. METHODS: In this study, we investigated the potential of hydrogels composed of four-armed poly(ethylene glycol) (starPEG) and heparin, with or without coagulation-responsive heparin release, as coatings for neurovascular devices to mitigate blood clot formation. We evaluated the feasibility and efficacy of these coatings on neurovascular devices through in vitro Chandler-Loop assays and implantation experiments in the supra-aortic arteries of rabbits. RESULTS: Stable and coagulation-responsive starPEG-heparin hydrogel coatings exhibited antithrombotic efficacy in vitro, although with a slightly reduced thromboprotection observed in vivo. Furthermore, the hydrogel coatings demonstrated robustness against shear forces encountered during deployment and elicited only marginal humoral and cellular inflammatory responses compared with the reference standards. CONCLUSION: Heparin hydrogel coatings offer promising benefits for enhancing the hemocompatibility of neurointerventional devices made of self-expanding nickel-titanium alloy. The variance in performance between in vitro and in vivo settings may be attributed to differences in low- and high-shear blood flow conditions inherent to these models. These models may represent the differences in venous and arterial systems. Further optimization is warranted to tailor the hydrogel coatings for improved efficacy in arterial applications.

18.
Artigo em Inglês | MEDLINE | ID: mdl-39217007

RESUMO

BACKGROUND: Intima proliferation and in-stent restenosis is a challenging situation in interventional treatment of small vessel obstruction. Al/Al2O3 nanowires have been shown to accelerate vascular endothelial cell proliferation and migration in vitro, while suppressing vascular smooth muscle cell growth. Moreover, surface modification of Al/Al2O3 nanowires with poly[bis(2,2,2-trifluoromethoxy)phosphazene (PTFEP) coating enables further advantages such as reduced platelet adhesion. Therefore, the study's goal was to compare the biocompatibility of novel Al/Al2O3 + PTFEP coated nanowire bare-metal stents to uncoated control stents in vivo using optical coherence tomography (OCT), quantitative angiography and histomorphometric assessment. METHODS: 15 Al/Al2O3 + PTFEP coated and 19 control stents were implanted in the cervical arteries of 9 Aachen minipigs. After 90 days, in-stent stenosis, thrombogenicity, and inflammatory response were assessed. Scanning electron microscopy was used to analyse the stent surface. RESULTS: OCT analysis revealed that neointimal proliferation in Al/Al2O3 + PTFEP coated stents was significantly reduced compared to control stents. The neointimal area was 1.16 ± 0.77 mm2 in Al/Al2O3 + PTFEP coated stents vs. 1.98 ± 1.04 mm2 in control stents (p = 0.004), and the neointimal thickness was 0.28 ± 0.20 vs. 0.47 ± 0.10 (p = 0.003). Quantitative angiography showed a tendency to less neointimal growth in coated stents. Histomorphometry showed no significant difference between the two groups and revealed an apparent inflammatory reaction surrounding the stent struts. CONCLUSIONS: At long-term follow-up, Al/Al2O3 + PTFEP coated stents placed in peripheral arteries demonstrated good tolerance with no treatment-associated vascular obstruction and reduced in-stent restenosis in OCT. These preliminary in vivo findings indicate that Al/Al2O3 + PTFEP coated nanowire stents may have translational potential to be used for the prevention of in-stent restenosis.

19.
J Am Heart Assoc ; 13(9): e031816, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639365

RESUMO

BACKGROUND: Data on impact of COVID-19 vaccination and outcomes of patients with COVID-19 and acute ischemic stroke undergoing mechanical thrombectomy are scarce. Addressing this subject, we report our multicenter experience. METHODS AND RESULTS: This was a retrospective analysis of patients with COVID-19 and known vaccination status treated with mechanical thrombectomy for acute ischemic stroke at 20 tertiary care centers between January 2020 and January 2023. Baseline demographics, angiographic outcome, and clinical outcome evaluated by the modified Rankin Scale score at discharge were noted. A multivariate analysis was conducted to test whether these variables were associated with an unfavorable outcome, defined as modified Rankin Scale score >3. A total of 137 patients with acute ischemic stroke (48 vaccinated and 89 unvaccinated) with acute or subsided COVID-19 infection who underwent mechanical thrombectomy attributable to vessel occlusion were included in the study. Angiographic outcomes between vaccinated and unvaccinated patients were similar (modified Thrombolysis in Cerebral Infarction ≥2b: 85.4% in vaccinated patients versus 86.5% in unvaccinated patients; P=0.859). The rate of functional independence (modified Rankin Scale score, ≤2) was 23.3% in the vaccinated group and 20.9% in the unvaccinated group (P=0.763). The mortality rate was 30% in both groups. In the multivariable analysis, vaccination status was not a significant predictor for an unfavorable outcome (P=0.957). However, acute COVID-19 infection remained significant (odds ratio, 1.197 [95% CI, 1.007-1.417]; P=0.041). CONCLUSIONS: Our study demonstrated no impact of COVID-19 vaccination on angiographic or clinical outcome of COVID-19-positive patients with acute ischemic stroke undergoing mechanical thrombectomy, whereas worsening attributable to COVID-19 was confirmed.


Assuntos
Vacinas contra COVID-19 , COVID-19 , AVC Isquêmico , Trombectomia , Vacinação , Humanos , COVID-19/complicações , COVID-19/terapia , COVID-19/mortalidade , Masculino , Feminino , AVC Isquêmico/mortalidade , AVC Isquêmico/cirurgia , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Vacinas contra COVID-19/efeitos adversos , SARS-CoV-2 , Idoso de 80 Anos ou mais
20.
Neuroradiology ; 2013 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-24233131

RESUMO

INTRODUCTION: In this study, we analyzed angiographic and histologic aneurysm occlusion of a newly designed flow-diverting device. Visibility and flexibility, as well as occlusions of side branches and neointimal proliferation were also evaluated. METHODS: Aneurysms were induced in 18 New Zealand white rabbits and treated with a braided, "closed-loop-designed" device of nitinol. Additional devices were implanted in the abdominal aorta to cover the origin of branch arteries. Angiographic follow-ups were performed immediately after placement of the device, after 3 months (n = 9) and 6 months (n = 9). The status of aneurysm occlusion (using a five-point scale) and the patency of branch arteries were assessed. RESULTS: Aneurysm occlusion rates were noted as grade 0 in 2 (11 %), grade I in 1 (6 %), grade II in 1 (6 %), grade III in 9 (50 %), and grade IV in 5 (28 %) of 18 aneurysms, respectively, indicating a complete or near-complete occlusion of 78 % under double antiplatelet therapy. Aneurysm occlusion was significantly higher at 6 months follow-up (P = 0.025). Radiopaque markers provided excellent visibility. Limited device flexibility led to incomplete aneurysm neck coverage and grade 0 occlusion rates in two cases. Distal device occlusions were found in three cases, most likely due to an extremely undersized vessel diameter in the subclavian artery. No case of branch artery occlusion was seen. Intimal proliferation and diameter stenosis were moderate. CONCLUSION: The tested flow diverter achieved near-complete and complete aneurysm occlusion under double antiplatelet therapy of elastase-induced aneurysms in 78 %, while preserving branch arteries.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA