Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Nat Methods ; 20(12): 2048-2057, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38012321

RESUMO

To increase granularity in human neuroimaging science, we designed and built a next-generation 7 Tesla magnetic resonance imaging scanner to reach ultra-high resolution by implementing several advances in hardware. To improve spatial encoding and increase the image signal-to-noise ratio, we developed a head-only asymmetric gradient coil (200 mT m-1, 900 T m-1s-1) with an additional third layer of windings. We integrated a 128-channel receiver system with 64- and 96-channel receiver coil arrays to boost signal in the cerebral cortex while reducing g-factor noise to enable higher accelerations. A 16-channel transmit system reduced power deposition and improved image uniformity. The scanner routinely performs functional imaging studies at 0.35-0.45 mm isotropic spatial resolution to reveal cortical layer functional activity, achieves high angular resolution in diffusion imaging and reduces acquisition time for both functional and structural imaging.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Cabeça , Neuroimagem , Razão Sinal-Ruído
2.
Neuroimage ; 286: 120504, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38216104

RESUMO

Small cerebral blood vessels are largely inaccessible to existing clinical in vivo imaging technologies. This study aims to present a novel analysis pipeline for vessel density mapping of small cerebral blood vessels from high-resolution 3D black-blood MRI at 3T. Twenty-eight subjects (10 under 35 years old, 18 over 60 years old) were imaged with the T1-weighted turbo spin-echo with variable flip angles (T1w TSE-VFA) sequence optimized for black-blood small vessel imaging with iso-0.5 mm spatial resolution (interpolated from 0.51×0.51×0.64 mm3) at 3T. Hessian-based vessel segmentation methods (Jerman, Frangi and Sato filter) were evaluated by vessel landmarks and manual annotation of lenticulostriate arteries (LSAs). Using optimized vessel segmentation, large vessel pruning and non-linear registration, a semiautomatic pipeline was proposed for quantification of small vessel density across brain regions and further for localized detection of small vessel changes across populations. Voxel-level statistics was performed to compare vessel density between two age groups. Additionally, local vessel density of aged subjects was correlated with their corresponding gross cognitive and executive function (EF) scores using Montreal Cognitive Assessment (MoCA) and EF composite scores compiled with Item Response Theory (IRT). Jerman filter showed better performance for vessel segmentation than Frangi and Sato filter which was employed in our pipeline. Small cerebral blood vessels including small artery, arterioles, small veins, and venules on the order of a few hundred microns can be delineated using the proposed analysis pipeline on 3D black-blood MRI at 3T. The mean vessel density across brain regions was significantly higher in young subjects compared to aged subjects. In the aged subjects, localized vessel density was positively correlated with MoCA and IRT EF scores. The proposed pipeline is able to segment, quantify, and detect localized differences in vessel density of small cerebral blood vessels based on 3D high-resolution black-blood MRI. This framework may serve as a tool for localized detection of small vessel density changes in normal aging and cerebral small vessel disease.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Idoso , Adulto , Pessoa de Meia-Idade , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/métodos , Artéria Cerebral Média , Encéfalo
3.
Magn Reson Med ; 92(5): 2261-2270, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39004827

RESUMO

PURPOSE: Driven by the Lorentz force, acoustic noise may arguably be the next physiological challenge associated with ultra-high field MRI scanners and powerful gradient coils. This work consisted of isolating and mitigating the main sound pathway in the NexGen 7 T scanner equipped with the investigational Impulse head gradient coil. METHODS: Sound pressure level (SPL) measurements were performed with and without the RF coil to assess its acoustic impact. Vibration measurements were carried out on the gradient coil, the RF coil, and on the patient table to distinguish the different vibration mechanisms and pathways. Vibrations of the RF coil were modified by either making contact with the patient bore liner with padding material or by changing directly the RF shield with phosphor bronze mesh material. RESULTS: SPL and vibration measurements demonstrated that eddy-currents induced in the RF shield were the primary cause of acoustic noise. Replacing the conventional solid copper shield with phosphor bronze mesh material altered the vibrations of the RF shield and decreased SPL by 6 to 8 dB at the highest frequencies in EPI, depending on the gradient axis, while boosting the transmit B1 + field by 15%. Padding led to slightly less sound reduction on the X and Z gradient axes, but with minimal impact for the Y axis. CONCLUSION: This study demonstrates the potential importance of eddy-current induced vibrations in the RF coil in terms of acoustic noise and opens new horizons for mitigation measures.


Assuntos
Acústica , Desenho de Equipamento , Imageamento por Ressonância Magnética , Ruído , Vibração , Imageamento por Ressonância Magnética/instrumentação , Humanos , Imagens de Fantasmas
4.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38440807

RESUMO

PURPOSE: Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T. METHODS: Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated. RESULTS: Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups. CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.


Assuntos
Artérias Cerebrais , Imageamento por Ressonância Magnética , Fluxo Pulsátil , Humanos , Feminino , Masculino , Adulto , Idoso , Reprodutibilidade dos Testes , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiologia , Fluxo Pulsátil/fisiologia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto Jovem , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
5.
Neuroimage ; 277: 120251, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37364741

RESUMO

Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (Gave = 0.4 mT/m, Gratio = 14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R = 2 × 2) and centric ordering was developed, and the number of segments (Nseg) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8°) and Nseg (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2 × 2 × 4 mm3 resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.


Assuntos
Encéfalo , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Encéfalo/diagnóstico por imagem , Marcadores de Spin , Artérias , Angiografia por Ressonância Magnética/métodos , Circulação Cerebrovascular , Córtex Cerebral
6.
Magn Reson Med ; 90(6): 2524-2538, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37466040

RESUMO

PURPOSE: To predict subject-specific local specific absorption rate (SAR) distributions of the human head for parallel transmission (pTx) systems at 7 T. THEORY AND METHODS: Electromagnetic energy deposition in tissues is nonuniform at 7 T, and interference patterns due to individual channels of pTx systems may result in increased local SAR values, which can only be estimated with very high safety margins. We proposed, designed, and demonstrated a multichannel 3D convolutional neural network (CNN) architecture to predict local SAR maps as well as peak-spatial SAR (ps-SAR) levels. We hypothesized that utilizing a three-channel 3D CNN, in which each channel is fed by a B 1 + $$ {B}_1^{+} $$ map, a phase-reversed B 1 + $$ {B}_1^{+} $$ map, and an MR image, would improve prediction accuracies and decrease uncertainties in the predictions. We generated 10 new head-neck body models, along with 389 3D pTx MRI data having different RF shim settings, with their B1 and local SAR maps to support efforts in this field. RESULTS: The proposed three-channel 3D CNN predicted ps-SAR10g levels with an average overestimation error of 20%, which was better than the virtual observation points-based estimation error (i.e., 152% average overestimation). The proposed method decreased prediction uncertainties over 20% (i.e., 22.5%-17.7%) compared to other methods. A safety factor of 1.20 would be enough to avoid underestimations for the dataset generated in this work. CONCLUSION: Multichannel 3D CNN networks can be promising in predicting local SAR values and perform predictions within a second, making them clinically useful as an alternative to virtual observation points-based methods.


Assuntos
Aprendizado Profundo , Humanos , Simulação por Computador , Cabeça/diagnóstico por imagem , Radiação Eletromagnética , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
7.
Magn Reson Med ; 87(1): 249-262, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34427341

RESUMO

PURPOSE: To optimize pseudo-continuous arterial spin labeling (pCASL) for 7 T, and to further improve the labeling efficiency with parallel RF transmission transmit B1 ( B1+ ) shimming. METHODS: pCASL parameters were optimized based on B1+/B0 field distributions at 7 T with simulation. To increase labeling efficiency, the B1+ amplitude at inflowing arteries was increased with parallel RF transmission B1+ shimming. The "indv-shim" with shimming weights calculated for each individual subject, and the "univ-shim" with universal weights calculated on a group of 12 subjects, were compared with circular polarized (CP) shim. The optimized pCASL sequences with three B1+ shimming modes (indv-shim, univ-shim, and CP-shim) were evaluated in 6 subjects who underwent two repeated scans 24 hours apart, along with a pulsed ASL sequence. Quantitative metrics including mean B1+ amplitude, perfusion, and intraclass correlation coefficient were calculated. The optimized 7T pCASL was compared with standard 3T pCASL on 5 subjects, using spatial SNR and temporal SNR. RESULTS: The optimal pCASL parameter set (RF duration/gap = 300/250 us, Gave=0.6mT/m,gRatio=10 ) achieved robust perfusion measurement in the presence of B1+/B0 inhomogeneities. Both indv-shim and univ-shim significantly increased B1+ amplitude compared with CP-shim in simulation and in vivo experiment (P < .01). Compared with CP-shim, perfusion signal was increased by 9.5% with indv-shim (P < .05) and by 5.3% with univ-shim (P = .35). All three pCASL sequences achieved fair to good repeatability (intraclass correlation coefficient ≥ 0.5). Compared with 3T pCASL, the optimized 7T pCASL achieved 78.3% higher spatial SNR and 200% higher temporal SNR. CONCLUSION: The optimized pCASL achieved robust perfusion imaging at 7 T, while both indv-shim and univ-shim further increased labeling efficiency.


Assuntos
Artérias , Encéfalo , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Simulação por Computador , Humanos , Imagem de Perfusão , Marcadores de Spin
8.
Magn Reson Med ; 85(6): 3227-3240, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33427349

RESUMO

PURPOSE: To optimize and evaluate adiabatic pulses for pulsed arterial spin labeling at ultrahigh field 7 tesla. METHODS: Four common adiabatic inversion pulses, including hyperbolic secant, wideband uniform rate smooth truncation, frequency offset corrected inversion, and time-resampled frequency offset corrected inversion pulses, were optimized based on a custom-defined loss function that included labeling efficiency and inversion band uniformity. The optimized pulses were implemented in flow-sensitive alternating inversion recovery sequences and tested on phantom and 11 healthy volunteers with 2 constraints: 1) specific absorption rate normalized; and 2) equal peak RF amplitude, respectively. A pseudo-continuous arterial spin labeling sequence was implemented for comparison. Quantitative metrics such as perfusion and relative labeling efficiency versus residual tissue signal were calculated. RESULTS: Among the 4 pulses, the wideband uniform rate smooth truncation pulse yielded the lowest loss in simulation and achieved a good balance between labeling efficiency and residual tissue signal from both phantom and in vivo experiments. Wideband uniform rate smooth truncation-pulsed arterial spin labeling showed significantly higher relative labeling efficiency compared to the other sequences (P < .01), whereas the perfusion signal was increased by 40% when the highest B1+ amplitude was used. The 4 pulsed arterial spin labeling sequences yielded comparable perfusion signals compared to pseudo-continuous arterial spin labeling but with less than half the specific absorption rate. CONCLUSION: Optimized wideband uniform rate smooth truncation pulse with the highest B1+ amplitude allowed was recommended for 7 tesla pulsed arterial spin labeling.


Assuntos
Artérias , Imageamento por Ressonância Magnética , Artérias/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Perfusão , Imagens de Fantasmas , Marcadores de Spin
9.
Magn Reson Med ; 85(5): 2735-2746, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33347641

RESUMO

PURPOSE: Characterizing vessel territories can provide crucial information for evaluation of cerebrovascular disorders. In this study, we present a novel postprocessing pipeline for vascular territorial imaging of cerebral arteries based on a noncontrast enhanced time-resolved 4D magnetic resonance angiography (MRA). METHODS: Eight healthy participants, 1 Moyamoya patient, and 1 arteriovenous malformations patient were recruited. Territorial segmentation and relative blood flow rate calculations of cerebral arteries including left and right middle cerebral arteries and left and right posterior cerebral arteries were carried out based on the 4D MRA-derived arterial arrival time maps of intracranial vessels. RESULTS: Among healthy young subjects, the average relative blood flow rate values corresponding to left and right middle cerebral arteries and left and right posterior cerebral arteries were 35.9 ± 5.9%, 32.9 ± 7.5%, 15.4 ± 3.8%, and 15.9 ± 2.5%, respectively. Excellent agreement was observed between relative blood flow rate values obtained from the proposed 4D MRA-based method and reference 2D phase contrast MRI. Abnormal cerebral circulations were visualized and quantified on both patients using the developed technique. CONCLUSION: The vascular territorial imaging technique developed in this study allowed for the generation of territorial maps with user-defined level of details within a clinically feasible scan time, and as such may provide useful information to assess cerebral circulation balance in different pathologies.


Assuntos
Angiografia por Ressonância Magnética , Doença de Moyamoya , Artérias Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Imageamento por Ressonância Magnética , Marcadores de Spin
10.
Acta Neuropathol ; 141(1): 1-24, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33098484

RESUMO

Brain arteriolosclerosis (B-ASC), characterized by pathologic arteriolar wall thickening, is a common finding at autopsy in aged persons and is associated with cognitive impairment. Hypertension and diabetes are widely recognized as risk factors for B-ASC. Recent research indicates other and more complex risk factors and pathogenetic mechanisms. Here, we describe aspects of the unique architecture of brain arterioles, histomorphologic features of B-ASC, relevant neuroimaging findings, epidemiology and association with aging, established genetic risk factors, and the co-occurrence of B-ASC with other neuropathologic conditions such as Alzheimer's disease and limbic-predominant age-related TDP-43 encephalopathy (LATE). There may also be complex physiologic interactions between metabolic syndrome (e.g., hypertension and inflammation) and brain arteriolar pathology. Although there is no universally applied diagnostic methodology, several classification schemes and neuroimaging techniques are used to diagnose and categorize cerebral small vessel disease pathologies that include B-ASC, microinfarcts, microbleeds, lacunar infarcts, and cerebral amyloid angiopathy (CAA). In clinical-pathologic studies that factored in comorbid diseases, B-ASC was independently associated with impairments of global cognition, episodic memory, working memory, and perceptual speed, and has been linked to autonomic dysfunction and motor symptoms including parkinsonism. We conclude by discussing critical knowledge gaps related to B-ASC and suggest that there are probably subcategories of B-ASC that differ in pathogenesis. Observed in over 80% of autopsied individuals beyond 80 years of age, B-ASC is a complex and under-studied contributor to neurologic disability.


Assuntos
Encéfalo/patologia , Arteriosclerose Intracraniana/patologia , Idoso , Idoso de 80 Anos ou mais , Animais , Arteríolas/patologia , Angiopatia Amiloide Cerebral , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/patologia , Transtornos Cognitivos/psicologia , Humanos , Arteriosclerose Intracraniana/psicologia , Neuroimagem
11.
Stroke ; 51(2): 489-497, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31884904

RESUMO

Background and Purpose- Selection of patients with acute ischemic stroke for endovascular treatment generally relies on dynamic susceptibility contrast magnetic resonance imaging or computed tomography perfusion. Dynamic susceptibility contrast magnetic resonance imaging requires injection of contrast, whereas computed tomography perfusion requires high doses of ionizing radiation. The purpose of this work was to develop and evaluate a deep learning (DL)-based algorithm for assisting the selection of suitable patients with acute ischemic stroke for endovascular treatment based on 3-dimensional pseudo-continuous arterial spin labeling (pCASL). Methods- A total of 167 image sets of 3-dimensional pCASL data from 137 patients with acute ischemic stroke scanned on 1.5T and 3.0T Siemens MR systems were included for neural network training. The concurrently acquired dynamic susceptibility contrast magnetic resonance imaging was used to produce labels of hypoperfused brain regions, analyzed using commercial software. The DL and 6 machine learning (ML) algorithms were trained with 10-fold cross-validation. The eligibility for endovascular treatment was determined retrospectively based on the criteria of perfusion/diffusion mismatch in the DEFUSE 3 trial (Endovascular Therapy Following Imaging Evaluation for Ischemic Stroke). The trained DL algorithm was further applied on twelve 3-dimensional pCASL data sets acquired on 1.5T and 3T General Electric MR systems, without fine-tuning of parameters. Results- The DL algorithm can predict the dynamic susceptibility contrast-defined hypoperfusion region in pCASL with a voxel-wise area under the curve of 0.958, while the 6 ML algorithms ranged from 0.897 to 0.933. For retrospective determination for subject-level endovascular treatment eligibility, the DL algorithm achieved an accuracy of 92%, with a sensitivity of 0.89 and specificity of 0.95. When applied to the GE pCASL data, the DL algorithm achieved a voxel-wise area under the curve of 0.94 and a subject-level accuracy of 92% for endovascular treatment eligibility. Conclusions- pCASL perfusion magnetic resonance imaging in conjunction with the DL algorithm provides a promising approach for assisting decision-making for endovascular treatment in patients with acute ischemic stroke.


Assuntos
Isquemia Encefálica/diagnóstico , Aprendizado Profundo , Imagem de Perfusão , Acidente Vascular Cerebral/diagnóstico , Circulação Cerebrovascular/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Estudos Retrospectivos , Marcadores de Spin
12.
Breast Cancer Res Treat ; 179(2): 377-385, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31612292

RESUMO

BACKGROUND: Breast cancer patients undergoing mastectomy with reconstruction (TM + R) often experience post-operative discomfort from surgical drains. Despite a variety of garment options for use in the post-operative period, high-quality data assessing the impact of specific garments on post-operative pain are lacking. We report the results of a prospective randomized trial assessing the impact of the Jacki Jacket (JJ), a long-sleeve jacket with inner drain receptacle pockets, on post-discharge pain and quality of life (QOL) after TM + R. METHODS: Breast cancer patients undergoing TM + R at a single institution were randomized post-operatively to receive a JJ or usual care (UC). Participant-reported demographics, pain intensity, and QOL were collected on post-operative day 1 (T1). Following discharge, participants completed a daily pain and medication dairy (T2); on day of drain(s) removal (T3), participants again completed pain and QOL questionnaires. Linear models were used to evaluate associations between JJ use, post-operative pain, and QOL. RESULTS: From 3/8/17 to 12/20/17, 139 women were randomized. All participants completed T1 measures, 102 returned the T2 diary, and 118 (84.9%) completed T3 questionnaires. There was no significant difference in pain scores between JJ and UC arms at any timepoint. Adjusting for surgery type, age, marital status, depression, and obesity, participants randomized to JJ reported significantly better body image scores (estimate = 12.94, p = 0.009). There were no adverse events. CONCLUSIONS: Although JJ garment use did not impact post-operative pain intensity scores, the significant impact of JJ use on body image supports consideration for inclusion of such garments in post-operative care for patients undergoing TM + R. CLINICAL TRIAL REGISTRATION INFORMATION: Registered with ClinicalTrials.gov, NCT number NCT02976103, November 18, 2016.


Assuntos
Neoplasias da Mama/cirurgia , Mamoplastia , Mastectomia , Adulto , Imagem Corporal , Neoplasias da Mama/diagnóstico , Feminino , Humanos , Mamoplastia/efeitos adversos , Mamoplastia/métodos , Mastectomia/efeitos adversos , Mastectomia/métodos , Estadiamento de Neoplasias , Manejo da Dor , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Projetos Piloto , Complicações Pós-Operatórias , Qualidade de Vida , Inquéritos e Questionários , Resultado do Tratamento
13.
Neuroimage ; 199: 184-193, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31158475

RESUMO

OBJECTIVES: The lenticulostriate arteries (LSAs) with small diameters of a few hundred microns take origin directly from the high flow middle cerebral artery (MCA), making them especially susceptible to damage (e.g. by hypertension). This study aims to present high resolution (isotropic ∼0.5 mm), black blood MRI for the visualization and characterization of LSAs at both 3 T and 7 T. MATERIALS AND METHODS: T1-weighted 3D turbo spin-echo with variable flip angles (T1w TSE-VFA) sequences were optimized for the visualization of LSAs by performing extended phase graph (EPG) simulations. Twenty healthy volunteers (15 under 35 years old, 5 over 60 years old) were imaged with the T1w TSE-VFA sequences at both 3 T and 7 T. Contrast-to-noise ratio (CNR) was quantified, and LSAs were manually segmented using ITK-SNAP. Automated Reeb graph shape analysis was performed to extract features including vessel length and tortuosity. All quantitative metrics were compared between the two field strengths and two age groups using ANOVA. RESULTS: LSAs can be clearly delineated using optimized 3D T1w TSE-VFA at 3 T and 7 T, and a greater number of LSA branches can be detected compared to those by time-of-flight MR angiography (TOF MRA) at 7 T. The CNR of LSAs was comparable between 7 T and 3 T. T1w TSE-VFA showed significantly higher CNR than TOF MRA at the stem portion of the LSAs branching off the medial middle cerebral artery. The mean vessel length and tortuosity were greater on TOF MRA compared to TSE-VFA. The number of detected LSAs by both TSE-VFA and TOF MRA was significantly reduced in aged subjects, while the mean vessel length measured on 7 T TSE-VFA showed significant difference between the two age groups. CONCLUSION: The high-resolution black-blood 3D T1w TSE-VFA sequence offers a new method for the visualization and quantification of LSAs at both 3 T and 7 T, which may be applied for a number of pathological conditions related to the damage of LSAs.


Assuntos
Imageamento por Ressonância Magnética/métodos , Artéria Cerebral Média/diagnóstico por imagem , Adulto , Idoso , Humanos , Angiografia por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto Jovem
14.
Magn Reson Med ; 81(5): 3065-3079, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30561821

RESUMO

PURPOSE: To present a novel MR pulse sequence and modeling algorithm to quantify the water exchange rate (kw ) across the blood-brain barrier (BBB) without contrast, and to evaluate its clinical utility in a cohort of elderly subjects at risk of cerebral small vessel disease (SVD). METHODS: A diffusion preparation module with spoiling of non-Carr-Purcell-Meiboom-Gill signals was integrated with pseudo-continuous arterial spin labeling (pCASL) and 3D gradient and spin echo (GRASE) readout. The tissue/capillary fraction of the arterial spin labeling (ASL) signal was separated by appropriate diffusion weighting (b = 50 s/mm2 ). kw was quantified using a single-pass approximation (SPA) model with total generalized variation (TGV) regularization. Nineteen elderly subjects were recruited and underwent 2 MRIs to evaluate the reproducibility of the proposed technique. Correlation analysis was performed between kw and vascular risk factors, Clinical Dementia Rating (CDR) scale, neurocognitive assessments, and white matter hyperintensity (WMH). RESULTS: The capillary/tissue fraction of ASL signal can be reliably differentiated with the diffusion weighting of b = 50 s/mm2 , given ~100-fold difference between the (pseudo-)diffusion coefficients of the 2 compartments. Good reproducibility of kw measurements (intraclass correlation coefficient = 0.75) was achieved. Average kw was 105.0 ± 20.6, 109.6 ± 18.9, and 94.1 ± 19.6 min-1 for whole brain, gray and white matter. kw was increased by 28.2%/19.5% in subjects with diabetes/hypercholesterolemia. Significant correlations between kw and vascular risk factors, CDR, executive/memory function, and the Fazekas scale of WMH were observed. CONCLUSION: A diffusion prepared 3D GRASE pCASL sequence with TGV regularized SPA modeling was proposed to measure BBB water permeability noninvasively with good reproducibility. kw may serve as an imaging marker of cerebral SVD and associated cognitive impairment.


Assuntos
Barreira Hematoencefálica/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Substância Branca/diagnóstico por imagem , Adulto , Idoso , Estudos de Coortes , Demência/diagnóstico por imagem , Difusão , Feminino , Voluntários Saudáveis , Humanos , Masculino , Testes de Estado Mental e Demência , Pessoa de Meia-Idade , Permeabilidade , Reprodutibilidade dos Testes , Fatores de Risco , Marcadores de Spin , Adulto Jovem
15.
JCO Oncol Pract ; 20(8): 1115-1122, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38608224

RESUMO

PURPOSE: Several allelic variants of the gene DPYD encoding dihydropyrimidine dehydrogenase (DPD) are associated with impaired metabolism of the systemic fluoropyrimidine fluorouracil (5FU) and its oral prodrug, capecitabine, which elevates the risk for severe toxicity. Following a patient death related to capecitabine toxicity in which DPD deficiency was suspected, a multidisciplinary advisory panel was convened to develop an institution-wide approach to future patients planned for a systemic fluoropyrimidine. METHODS: The panel selected an opt-out testing strategy which focused on developing reliable processes to collect and report test results and targeted education. An electronic health record-based automated reminder was designed to activate when a 5FU- or capecitabine-containing chemotherapy regimen was ordered for a patient without prior exposure to either agent and without a prior DPYD sequencing test result. DPYD testing was standardized across all sites of care, and a closed loop reporting system for abnormal test results was created. Before implementation, targeted education was provided to providers, pharmacists, and nurses, and a failure mode and effects analysis was performed. Program rollout was staged over a 6-month period. RESULTS: At 10 months, the rate of preemptive testing increased from a baseline of 26% to a sustained rate of >90%. In the six network sites, the testing rate increased from 9% to 96%. A total of 1,043 patients have been tested preemptively; allelic variants have been identified in 43 (4.1%). Among 25 evaluable patients, dose reduction or change to a non-fluoropyrimidine-based regimen was accomplished in 96%. CONCLUSION: Preemptive DPYD testing is feasible, and high rates of testing can be achieved using an opt-out, reminder-based program. We provide the details of the implementation and encourage others to emulate it.


Assuntos
Di-Hidrouracila Desidrogenase (NADP) , Humanos , Di-Hidrouracila Desidrogenase (NADP)/genética , Di-Hidrouracila Desidrogenase (NADP)/metabolismo , Fluoruracila/efeitos adversos , Capecitabina/efeitos adversos , Capecitabina/uso terapêutico , Masculino , Feminino , Antimetabólitos Antineoplásicos/efeitos adversos , Antimetabólitos Antineoplásicos/uso terapêutico
16.
NMR Biomed ; 26(9): 1089-95, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23417762

RESUMO

The amelioration of secondary neurological damage is among the most important therapeutic goals for patients with intracerebral hemorrhage (ICH). Secondary injury of the ipsilateral substantia nigra (SN) and pyramidal tract (PY) is common after cerebral stroke. Such injury has been characterized previously by anatomical or diffusion MRI, but not in a comprehensive manner, and the knowledge regarding the contralateral changes is relatively poor. This study examined longitudinally both contralateral and ipsilateral SN and PY changes following experimental ICH with diffusion tensor imaging (DTI) and histology. ICH was induced in 14 Sprague-Dawley rats by the infusion of collagenase into the right striatum. Four-shot, spin-echo, echo-planar DTI was performed at 7 T with a b value of 1000 s/mm(2) and 30 diffusion gradient directions at 3.5 h and days 1, 3, 7, 14, 42 and 120 after ICH. Fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (λ// ) and radial diffusivity (λ┴ ) were measured in SN and PY accordingly. Two to three rats were sacrificed at days 3, 7, 42 and 120 for histology. The contralateral SN showed an increase in λ// with perivascular enlargement during the first 3 days after ICH. The ipsilateral SN showed increases in FA, λ// , λ┴ and MD at day 1, dramatic decreases at day 3 with neuronal degeneration and neuropil vacuolation, and subsequent gradual normalization. The contralateral PY showed diffusivity decreases at day 1. The ipsilateral PY showed early decreases and then late increases in MD and λ┴, and continuously decreasing FA and λ// with progressive axonal loss and demyelination. In summary, DTI revealed early bilateral changes in SN and PY following ICH. The evolution of the ipsilateral parameters correlated with the histological findings. In the ipsilateral PY, λ// and λ┴ changes indicated evolving and complex pathological processes underlying the monotonic FA decrease. These results support the use of quantitative multiparametric DTI for the evaluation of SN and PY injuries in clinical and preclinical investigations of ICH.


Assuntos
Hemorragia Cerebral/patologia , Imagem de Tensor de Difusão , Tratos Piramidais/patologia , Substância Negra/patologia , Animais , Feminino , Hematoma/patologia , Proteínas de Neurofilamentos/metabolismo , Ratos , Ratos Sprague-Dawley
17.
bioRxiv ; 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36993509

RESUMO

Cerebral small vessels are largely inaccessible to existing clinical in vivo imaging technologies. This study aims to present a novel analysis pipeline for vessel density mapping of cerebral small vessels from high-resolution 3D black-blood MRI at 3T. Twenty-eight subjects (10 under 35 years old, 18 over 60 years old) were imaged with the T1-weighted turbo spin-echo with variable flip angles (T1w TSE-VFA) sequence optimized for black-blood small vessel imaging with iso-0.5mm spatial resolution at 3T. Hessian-based vessel segmentation methods (Jerman, Frangi and Sato filter) were evaluated by vessel landmarks and manual annotation of lenticulostriate arteries (LSAs). Using optimized vessel segmentation, large vessel pruning and non-linear registration, a semiautomatic pipeline was proposed for quantification of small vessel density across brain regions and further for localized detection of small vessel changes across populations. Voxel-level statistics was performed to compare vessel density between two age groups. Additionally, local vessel density of aged subjects was correlated with their corresponding gross cognitive and executive function (EF) scores using Montreal Cognitive Assessment (MoCA) and EF composite scores compiled with Item Response Theory (IRT). Jerman filter showed better performance for vessel segmentation than Frangi and Sato filter which was employed in our pipeline. Cerebral small vessels on the order of a few hundred microns can be delineated using the proposed analysis pipeline on 3D black-blood MRI at 3T. The mean vessel density across brain regions was significantly higher in young subjects compared to aged subjects. In the aged subjects, localized vessel density was positively correlated with MoCA and IRT EF scores. The proposed pipeline is able to segment, quantify, and detect localized differences in vessel density of cerebral small vessels based on 3D high-resolution black-blood MRI. This framework may serve as a tool for localized detection of small vessel density changes in normal aging and cerebral small vessel disease.

18.
medRxiv ; 2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37163115

RESUMO

Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (Gave=0.4mT/m, Gratio=14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R=2×2) and centric ordering was developed, and the number of segments (Nseg) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8 ° ) and Nseg (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2×2×4 mm 3 resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.

19.
JMIR Dermatol ; 5(2): e37034, 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37632874

RESUMO

BACKGROUND: Digital 3D total-body photography of the skin surface is an emerging imaging modality that can facilitate the identification of new and changing nevi. OBJECTIVE: We aimed to describe the experiences of study participants drawn from the general population who were provided 3D total-body photography and dermoscopy for the monitoring of nevi. METHODS: A population-based prospective study of adults aged 20-70 years from South East Queensland, Australia was conducted. Participants underwent 3D total-body photography and dermoscopy every 6 months over a 3-year period. Participants were asked to provide closed and open-ended feedback on their 3D total-body photography and dermoscopy experience (eg, comfort, trust, intended future use, and willingness to pay) at the halfway study time point (18 months) and final study time point (36 months). We assessed changes in participants' reported experience of 3D total-body photography, and patient characteristics associated with patient experience at the end of the study (36 months) were analyzed. RESULTS: A total of 149 participants completed the surveys at both the 18- and 36-month time points (median age 55, range 23-70 years; n=94, 63.1% were male). At the 18-month time point, most participants (n=103, 69.1%) stated they completely trusted 3D total-body imaging for the diagnosis and monitoring of their nevi, and this did not change at the 36-month (n=104, 69.8%) time point. The majority of participants reported that they were very comfortable or comfortable with the technology at both the 18- (n=138, 92.6%) and 36-month (n=140, 94%) time points, respectively; albeit, the number of participants reporting that they were very comfortable reduced significantly between the 18- and 36-month time points, from 71.1% (n=106) to 61.1% (n=91; P=.01). Almost all participants (n=140, 94%) would consider using this technology if it were to become commercially available, and this did not change during the two study time points. Half of the participants (n=74) cited barriers to participating in 3D total-body photography, including trust in the ability of this technology to detect and monitor suspicious lesions, digital privacy, cost, and travel requirements. CONCLUSIONS: The majority of participants expressed positive attitudes toward 3D total-body photography for the monitoring of their moles. Half of the participants identified potential barriers to uptake.

20.
Magn Reson Imaging Clin N Am ; 29(1): 53-65, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33237015

RESUMO

Ultrahigh field offers increased resolution and contrast for neurovascular imaging. Arterial spin labeling methods benefit from an increased intrinsic signal-to-noise ratio of MR imaging signal and a prolonged tracer half-life at ultrahigh field, allowing the visualization of layer-dependent microvascular perfusion. Arterial spin labeling-based time-resolved 4-dimensional MR angiography at 7T provides a detailed depiction of the vascular architecture and dynamic blood flow pattern with high spatial and temporal resolutions. High-resolution black blood MR imaging at 7T allows detailed characterization of small perforating arteries such as lenticulostriate arteries. All techniques benefit from advances in parallel radiofrequency transmission technologies at ultrahigh field.


Assuntos
Transtornos Cerebrovasculares/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Humanos , Angiografia por Ressonância Magnética/métodos , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA