Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 242
Filtrar
1.
Neuroimage ; 296: 120666, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38830440

RESUMO

Direct imaging of semi-solid lipids, such as myelin, is of great interest as a noninvasive biomarker of neurodegenerative diseases. Yet, the short T2 relaxation times of semi-solid lipid protons hamper direct detection through conventional magnetic resonance imaging (MRI) pulse sequences. In this study, we examined whether a three-dimensional ultrashort echo time (3D UTE) sequence can directly acquire signals from membrane lipids. Membrane lipids from red blood cells (RBC) were collected from commercially available blood as a general model of the myelin lipid bilayer and subjected to D2O exchange and freeze-drying for complete water removal. Sufficiently high MR signals were detected with the 3D UTE sequence, which showed an ultrashort T2* of ∼77-271 µs and a short T1 of ∼189 ms for semi-solid RBC membrane lipids. These measurements can guide designing UTE-based sequences for direct in vivo imaging of membrane lipids.


Assuntos
Membrana Eritrocítica , Imageamento por Ressonância Magnética , Lipídeos de Membrana , Bainha de Mielina , Humanos , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina/química , Membrana Eritrocítica/química , Membrana Eritrocítica/metabolismo , Lipídeos de Membrana/química , Liofilização , Eritrócitos/metabolismo
2.
Neuroimage ; 298: 120800, 2024 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-39159704

RESUMO

In this study, we describe a comprehensive 3D magnetic resonance imaging (MRI) protocol designed to assess major tissue and fluid components in the brain. The protocol comprises four different sequences: 1) magnetization transfer prepared Cones (MT-Cones) for two-pool MT modeling to quantify macromolecular content; 2) short-TR adiabatic inversion-recovery prepared Cones (STAIR-Cones) for myelin water imaging; 3) proton-density weighted Cones (PDw-Cones) for total water imaging; and 4) highly T2 weighted Cones (T2w-Cones) for free water imaging. By integrating these techniques, we successfully mapped key brain components-namely macromolecules, myelin water, intra/extracellular water, and free water-in ten healthy volunteers and five patients with multiple sclerosis (MS) using a 3T clinical scanner. Brain macromolecular proton fraction (MMPF), myelin water proton fraction (MWPF), intra/extracellular water proton fraction (IEWPF), and free water proton fraction (FWPF) values were generated in white matter (WM), grey matter (GM), and MS lesions. Excellent repeatability of the protocol was demonstrated with high intra-class correlation coefficient (ICC) values. In MS patients, the MMPF and MWPF values of the lesions and normal-appearing WM (NAWM) were significantly lower than those in normal WM (NWM) in healthy volunteers. Moreover, we observed significantly higher FWPF values in MS lesions compared to those in NWM and NAWM regions. This study demonstrates the capability of our technique to volumetrically map major brain components. The technique may have particular value in providing a comprehensive assessment of neuroinflammatory and neurodegenerative diseases of the brain.

3.
Magn Reson Med ; 91(3): 896-910, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37755319

RESUMO

PURPOSE: To develop a 3D phase modulated UTE adiabatic T1ρ (PM-UTE-AdiabT1ρ ) sequence for whole knee joint mapping on a clinical 3 T scanner. METHODS: This new sequence includes six major features: (1) a magnetization reset module, (2) a train of adiabatic full passage pulses for spin locking, (3) a phase modulation scheme (i.e., RF cycling pair), (4) a fat saturation module, (5) a variable flip angle scheme, and (6) a 3D UTE Cones sequence for data acquisition. A simple exponential fitting was used for T1ρ quantification. Phantom studies were performed to investigate PM-UTE-AdiabT1ρ 's sensitivity to compositional changes and reproducibility as well as its correlation with continuous wave-T1ρ measurement. The PM-UTE-AdiabT1ρ technique was then applied to five ex vivo and five in vivo normal knees to measure T1ρ values of femoral cartilage, meniscus, posterior cruciate ligament, anterior cruciate ligament, patellar tendon, and muscle. RESULTS: The phantom study demonstrated PM-UTE-AdiabT1ρ 's high sensitivity to compositional changes, its high reproducibility, and its strong linear correlation with continuous wave-T1ρ measurement. The ex vivo and in vivo knee studies demonstrated average T1ρ values of 105.6 ± 8.4 and 77.9 ± 3.9 ms for the femoral cartilage, 39.2 ± 5.1 and 30.1 ± 2.2 ms for the meniscus, 51.6 ± 5.3 and 29.2 ± 2.4 ms for the posterior cruciate ligament, 79.0 ± 9.3 and 52.0 ± 3.1 ms for the anterior cruciate ligament, 19.8 ± 4.5 and 17.0 ± 1.8 ms for the patellar tendon, and 91.1 ± 8.8 and 57.6 ± 2.8 ms for the muscle, respectively. CONCLUSION: The 3D PM-UTE-AdiabT1ρ sequence allows volumetric T1ρ assessment for both short and long T2 tissues in the knee joint on a clinical 3 T scanner.


Assuntos
Menisco , Ligamento Patelar , Reprodutibilidade dos Testes , Articulação do Joelho/diagnóstico por imagem , Ligamento Cruzado Anterior/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
4.
Magn Reson Med ; 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39119819

RESUMO

PURPOSE: The semisolid myelin sheath has very fast transverse relaxation and is invisible to conventional MRI sequences. UTE sequences can detect signal from myelin. The major challenge is the concurrent detection of various water components. METHODS: The inversion recovery (IR)-based UTE (IR-UTE) sequence employs an adiabatic inversion pulse to invert and suppress water magnetizations. TI plays a key role in water suppression, with negative water magnetizations (negative phase) before the null point and positive water magnetizations (positive phase) after the null point. A series of dual-echo IR-UTE images were acquired with different TIs to detect water phase transition. The effects of TR in phase transition and water suppression were also investigated using a relatively long TR of 500 ms and a short TR of 106 ms. The water phase transition in dual-echo IR-UTE imaging of myelin was investigated in five ex vivo and five in vivo human brains. RESULTS: An apparent phase transition was observed in the second echo at the water signal null point, where the myelin signal was selectively detected by the UTE data acquisition at the optimal TI. The water phase transition point varied significantly across the brain when the long TR of 500 ms was used, whereas the convergence of TIs was observed when the short TR of 106 ms was used. CONCLUSION: The results suggest that the IR-UTE sequence with a short TR allows uniform inversion and nulling of water magnetizations, thereby providing volumetric imaging of myelin.

5.
NMR Biomed ; 37(2): e5058, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37828713

RESUMO

Muscle degeneration following rotator cuff tendon tearing is characterized by fatty infiltration and fibrosis. While tools exist for the characterization of fat, the ability to noninvasively assess muscle fibrosis is limited. The purpose of this study was to evaluate the capability of quantitative ultrashort echo time T1 (UTE-T1) and UTE magnetization transfer (UTE-MT) mapping with and without fat suppression (FS) for the differentiation of injured and control rotator cuff muscles and for the detection of fibrosis. A rat model of chronic massive rotator cuff tearing (n = 12) was used with tenotomy of the right supraspinatus and infraspinatus tendons and silicone implants to prevent healing. Imaging was performed on a 3-T scanner, and UTE-T1 mapping with and without FS and UTE-MT with and without FS for macromolecular fraction (MMF) mapping was performed. At 20 weeks postinjury, T1 and MMF were measured in the supraspinatus and infraspinatus muscles of the injured and contralateral, internal control sides. Histology was performed and connective tissue fraction (CTF) was measured, defined as the area of collagen-rich extracellular matrix divided by the total muscle area. Paired t-tests and correlation analyses were performed. Significant differences between injured and control sides were found for CTF in the supraspinatus (mean ± SD, 14.5% ± 3.9% vs. 11.3% ± 3.7%, p = 0.01) and infraspinatus (17.0% ± 5.4% vs. 12.5% ± 4.6%, p < 0.01) muscles, as well as for MMF using UTE-MT FS in the supraspinatus (9.7% ± 0.3% vs. 9.5% ± 0.2%, p = 0.04) and infraspinatus (10.9% ± 0.8% vs. 10.1% ± 0.5%, p < 0.01) muscles. No significant differences between sides were evident for T1 without or with FS or for MMF using UTE-MT. Only MMF using UTE-MT FS was significantly correlated with CTF for both supraspinatus (r = 0.46, p = 0.03) and infraspinatus (r = 0.51, p = 0.01) muscles. Fibrosis occurs in rotator cuff muscle degeneration, and the UTE-MT FS technique may be helpful to evaluate the fibrosis component, independent from the fatty infiltration process.


Assuntos
Manguito Rotador , Tendões , Animais , Ratos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Atrofia Muscular , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/patologia
6.
NMR Biomed ; 37(1): e5040, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37740595

RESUMO

The purpose of this study is to investigate the use of ultrashort echo time (UTE) magnetic resonance imaging (MRI) techniques (T1 and magnetization transfer [MT] modeling) for imaging of the Achilles tendons and entheses in patients with psoriatic arthritis (PsA) compared with asymptomatic volunteers. The heels of twenty-six PsA patients (age 59 ± 15 years, 41% female) and twenty-seven asymptomatic volunteers (age 33 ± 11 years, 47% female) were scanned in the sagittal plane with UTE-T1 and UTE-MT modeling sequences on a 3-T clinical scanner. UTE-T1 and macromolecular proton fraction (MMF; the main outcome of MT modeling) were calculated in the tensile portions of the Achilles tendon and at the enthesis (close to the calcaneus bone). Mann-Whitney-U tests were used to examine statistically significant differences between the two cohorts. UTE-T1 in the entheses was significantly higher for the PsA group compared with the asymptomatic group (967 ± 145 vs. 872 ± 133 ms, p < 0.01). UTE-T1 in the tendons was also significantly higher for the PsA group (950 ± 145 vs. 850 ± 138 ms, p < 0.01). MMF in the entheses was significantly lower in the PsA group compared with the asymptomatic group (15% ± 3% vs. 18% ± 3%, p < 0.01). MMF in the tendons was also significantly lower in the PsA group compared with the asymptomatic group (17% ± 4% vs. 20% ± 5%, p < 0.01). Percentage differences in MMF between the asymptomatic and PsA groups (-16.6% and -15.0% for the enthesis and tendon, respectively) were higher than the T1 differences (10.8% and 11.7% for the enthesis and tendon, respectively). The results suggest higher T1 and lower MMF in the Achilles tendons and entheses in PsA patients compared with the asymptomatic group. This study highlights the potential of UTE-T1 and UTE-MT modeling for quantitative evaluation of entheses and tendons in PsA patients.


Assuntos
Tendão do Calcâneo , Artrite Psoriásica , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Masculino , Tendão do Calcâneo/diagnóstico por imagem , Artrite Psoriásica/diagnóstico por imagem , Artrite Psoriásica/patologia , Imageamento por Ressonância Magnética/métodos , Prótons
7.
J Magn Reson Imaging ; 59(4): 1285-1298, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37470693

RESUMO

BACKGROUND: Bone collagen-matrix contributes to the mechanical properties of bone by imparting tensile strength and elasticity, which can be indirectly quantified by ultrashort echo time magnetization transfer ratio (UTE-MTR) to assess osteoporosis. PURPOSE: To evaluate osteoporosis at the human lumbar spine using UTE-MTR. STUDY TYPE: Prospective. POPULATION: One hundred forty-eight-volunteers (age-range, 50-85; females, N = 90), including 81-normal bone density, 35-osteopenic, and 32-osteoporotic subjects. Ten additional healthy volunteers were recruited to study the intrasession reproducibility of the UTE-MT. FIELD STRENGTH/SEQUENCE: 3T/UTE-MT, short repetition-time adiabatic inversion recovery prepared UTE (STAIR-UTE), and iterative decomposition of water-and-fat with echo-asymmetry and least-squares estimation (IDEAL-IQ). ASSESSMENT: Fracture risk was calculated using Fracture-Risk-Assessment-Tool (FRAX). Region-of-interests (ROIs) were delineated on the trabecular area in the maps of bone-mineral-density, UTE-MTR, collagen-bound water proton-fraction (CBWPF), and bone-marrow fat fraction (BMFF). STATISTICAL TESTS: Linear-regression and Bland-Altman analysis were performed to assess the reproducibility of UTE-MTR measurements in the different scans. UTE-MTR and BMFF were correlated with bone-mineral-density using Pearson's regression and with FRAX scores using nonlinear regression. The abilities of UTE-MTR, CBWPF, and BMFF to discriminate between the three patient subgroups were evaluated using receiver-operator-characteristic (ROC) analysis and area-under-the-curve (AUC). Decision-curve-analysis (DCA) and clinical-impact curves were used to evaluate the value of UTE-MTR in clinical diagnosis. The DeLong test was used to compare the ROC curves. P-value <0.05 was considered statistically significant. RESULTS: Excellent reproducibility was obtained for the UTE-MT measurements. UTE-MTR strongly correlated with bone-mineral-density (r = 0.76) and FRAX scores (r = -0.77). UTE-MTR exhibited higher AUCs (≥0.723) than BMFF, indicating its superior ability to distinguish between the three patient subgroups. The DCA and clinical-impact curves confirmed the diagnostic value of UTE-MTR. UTE-MTR and CBWPF showed similar performance in correlation with bone-mineral-density and cohort classification. DATA CONCLUSION: UTE-MTR strongly correlates with bone-mineral-density and FRAX and shows great potential in distinguishing between normal, osteopenic, and osteoporotic subjects. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imageamento por Ressonância Magnética , Osteoporose , Feminino , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Osteoporose/diagnóstico por imagem , Colágeno , Prótons , Água , Minerais
8.
J Magn Reson Imaging ; 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39165086

RESUMO

The cartilaginous endplate (CEP) plays a pivotal role in facilitating the supply of nutrients and, transport of metabolic waste, as well as providing mechanical support for the intervertebral disc (IVD). Recent technological advances have led to a surge in MR imaging studies focused on the CEP. This article describes the anatomy and functions of the CEP as well as MRI techniques for both qualitative and quantitative assessment of the CEP. Effective CEP MR imaging sequences require two key features: high spatial resolution and relatively short echo time. High spatial resolution spoiled gradient echo (SPGR) and ultrashort echo time (UTE) sequences, fulfilling these requirements, are the basis for most of the sequences employed in CEP imaging. This article reviews existing sequences for qualitative CEP imaging, such as the fat-suppressed SPGR and UTE, dual-echo subtraction UTE, inversion recovery prepared and fat-suppressed UTE, and dual inversion recovery prepared UTE sequences. These sequences are employed together with other techniques for quantitative CEP imaging, including measurements of T2*, T2, T1, T1ρ, magnetization transfer, perfusion, and diffusion tensor parameters. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

9.
Langmuir ; 40(20): 10663-10675, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38718299

RESUMO

Electrocatalytic reduction (ECR) of CO2 to chemical products is an important carbon emission reduction method. This work uses DFT to study the stability of N-doped graphene-supported four metal single-atom catalysts (M-N-C) and the effects of the coordination environment and metal centers on the selectivity of CO2 ECR to C1 products. The results show that Fe, Co, Ni, and Cu have good stability. The coordination environment has a significant modulating effect on product selectivity, and the change of the number of ligand nitrogen atoms will affect the size of the potential-limiting step of each product. When the number of nitrogen ligands is the same, the different metal centers of the M-N-C catalyst have a significant effect on the selectivity of different products. In addition, the introduction of nitrogen atom ligands can adjust the electronic structure of the graphene-supported metal center, increase the d-band center of most metals, and improve the reaction activity.

10.
MAGMA ; 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39126439

RESUMO

OBJECTIVE: To assess and improve the reliability of the ultrashort echo time quantitative magnetization transfer (UTE-qMT) modeling of the cortical bone. MATERIALS AND METHODS: Simulation-based digital phantoms were created that mimic the UTE-qMT properties of cortical bones. A wide range of SNR from 25 to 200 was simulated by adding different levels of noise to the synthesized MT-weighted images to assess the effect of SNR on UTE-qMT fitting results. Tensor-based denoising algorithm was applied to improve the fitting results. These results from digital phantom studies were validated via ex vivo rat leg bone scans. RESULTS: The selection of initial points for nonlinear fitting and the number of data points tested for qMT analysis have minimal effect on the fitting result. Magnetization exchange rate measurements are highly dependent on the SNR of raw images, which can be substantially improved with an appropriate denoising algorithm that gives similar fitting results from the raw images with an 8-fold higher SNR. DISCUSSION: The digital phantom approach enables the assessment of the reliability of bone UTE-qMT fitting by providing the known ground truth. These findings can be utilized for optimizing the data acquisition and analysis pipeline for UTE-qMT imaging of cortical bones.

11.
BMC Geriatr ; 24(1): 331, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605326

RESUMO

BACKGROUND: Motor cognitive risk syndrome (MCR) represents a critical pre-dementia and disability state characterized by a combination of objectively measured slow walking speed and subjective memory complaints (SMCs). This study aims to identify risk factors for MCR and investigate the relationship between plasma levels of 8-hydroxy-2'-deoxyguanosine (8-OHdG) and MCR among Chinese community-dwelling elderly populations. METHODS: A total of 1312 participants were involved in this study based on the data of the Rugao Longevity and Aging Study (RuLAS). The MCR was characterized by SMCs and slow walking speed. The SCCs were defined as a positive answer to the question 'Do you feel you have more problems with memory than most?' in a 15-item Geriatric Depression Scale. Slow walking speed was determined by one standard deviation or more below the mean value of the patient's age and gender group. The plasma of 8-OHdG were measured by a technician in the biochemistry laboratory of the Rugao People's Hospital during the morning of the survey. RESULTS: The prevalence of MCR was found to be 7.9%. After adjusting for covariates, significant associations with MCR were observed in older age (OR 1.057; p = 0.018), history of cerebrovascular disease (OR 2.155; p = 0.010), and elevated 8-OHdG levels (OR 1.007; p = 0.003). CONCLUSIONS: This study indicated the elevated plasma 8-OHdG is significantly associated with increased MCR risk in the elderly, suggesting its potential as a biomarker for early detection and intervention in MCR. This finding underscores the importance of monitoring oxidative DNA damage markers in predicting cognitive and motor function declines, offering new avenues for research and preventive strategies in aging populations.


Assuntos
Transtornos Cognitivos , Disfunção Cognitiva , População do Leste Asiático , Humanos , Idoso , Transtornos Cognitivos/diagnóstico , Estudos Transversais , 8-Hidroxi-2'-Desoxiguanosina , Longevidade , Envelhecimento/psicologia , Fatores de Risco , Cognição , Disfunção Cognitiva/epidemiologia
12.
Skeletal Radiol ; 53(5): 881-890, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37935923

RESUMO

PURPOSE: To investigate the feasibility and application of a novel imaging technique, a three-dimensional dual adiabatic inversion recovery prepared ultrashort echo time (3D DIR-UTE) sequence, for high contrast assessment of cartilaginous endplate (CEP) imaging with head-to-head comparisons between other UTE imaging techniques. METHOD: The DIR-UTE sequence employs two narrow-band adiabatic full passage (AFP) pulses to suppress signals from long T2 water (e.g., nucleus pulposus (NP)) and bone marrow fat (BMF) independently, followed by multispoke UTE acquisition to detect signals from the CEP with short T2 relaxation times. The DIR-UTE sequence, in addition to three other UTE sequences namely, an IR-prepared and fat-saturated UTE (IR-FS-UTE), a T1-weighted and fat-saturated UTE sequence (T1w-FS-UTE), and a fat-saturated UTE (FS-UTE) was used for MR imaging on a 3 T scanner to image six asymptomatic volunteers, six patients with low back pain, as well as a human cadaveric specimen. The contrast-to-noise ratio of the CEP relative to the adjacent structures-specifically the NP and BMF-was then compared from the acquired images across the different UTE sequences. RESULTS: For asymptomatic volunteers, the DIR-UTE sequence showed significantly higher contrast-to-noise ratio values between the CEP and BMF (CNRCEP-BMF) (19.9 ± 3.0) and between the CEP and NP (CNRCEP-NP) (23.1 ± 1.7) compared to IR-FS-UTE (CNRCEP-BMF: 17.3 ± 1.2 and CNRCEP-NP: 19.1 ± 1.8), T1w-FS-UTE (CNRCEP-BMF: 9.0 ± 2.7 and CNRCEP-NP: 10.4 ± 3.5), and FS-UTE (CNRCEP-BMF: 7.7 ± 2.2 and CNRCEP-NP: 5.8 ± 2.4) for asymptomatic volunteers (all P-values < 0.001). For the spine sample and patients with low back pain, the DIR-UTE technique detected abnormalities such as irregularities and focal defects in the CEP regions. CONCLUSION: The 3D DIR-UTE sequence is able to provide high-contrast volumetric CEP imaging for human spines on a clinical 3 T scanner.


Assuntos
Dor Lombar , Humanos , Osso e Ossos , Imageamento por Ressonância Magnética/métodos , Cartilagem , Imagens de Fantasmas , Imageamento Tridimensional/métodos
13.
Luminescence ; 39(3): e4712, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481369

RESUMO

In this study, a novel fluorescent chemosensor 1 based on chromone-3-carboxaldehyde Schiff base was synthesized and featured through nuclear magnetic resonance (NMR) and mass spectra. Spectroscopic investigation indicated that the fluorescent sensor showed high selectivity toward Zn2+ over other metal ions and that the detection limit of 1 could reach 10-7  M. These indicated that 1 acted as a highly selective and sensitive fluorescence chemosensor for Zn2+ .


Assuntos
Corantes Fluorescentes , Bases de Schiff , Espectrometria de Fluorescência/métodos , Corantes Fluorescentes/química , Bases de Schiff/química , Cromonas , Zinco
14.
Int J Mol Sci ; 25(12)2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38928308

RESUMO

Hepatic ischemia/reperfusion injury (IRI) is an important factor affecting liver regeneration and functional recovery postoperatively. Many studies have suggested that mesenchymal stem cells (MSCs) contribute to hepatic tissue repair and functional recovery through paracrine mechanisms mediated by exosomes. Minipigs exhibit much more similar characteristics of the liver to those of humans than rodents. This study aimed to explore whether exosomes from adipose-derived MSCs (ADSCs-exo) could actively promote liver regeneration after hepatectomy combined with HIRI in minipigs and the role they play in the cell proliferation process. This study also compared the effects and differences in the role of ADSCs and ADSCs-exo in the inflammatory response and liver regeneration. The results showed that ADSCs-exo suppressed histopathological changes and reduced inflammatory infiltration in the liver; significantly decreased levels of ALT, TBIL, HA, and the pro-inflammatory cytokines TNF-α, IL-6, and CRP; increased levels of the anti-inflammatory cytokine IL-10 and the pro-regeneration factors Ki67, PCNA, CyclinD1, HGF, STAT3, VEGF, ANG1, ANG2; and decreased levels of the anti-regeneration factors SOCS3 and TGF-ß. These indicators above showed similar changes with the ADSCs intervention group. Indicating that ADSCs-exo can exert the same role as ADSCs in regulating inflammatory responses and promoting liver regeneration. Our findings provide experimental evidence for the possibility that ADSCs-exo could be considered a safe and effective cell-free therapy to promote regeneration of injured livers.


Assuntos
Tecido Adiposo , Exossomos , Regeneração Hepática , Fígado , Células-Tronco Mesenquimais , Porco Miniatura , Animais , Suínos , Células-Tronco Mesenquimais/metabolismo , Células-Tronco Mesenquimais/citologia , Exossomos/metabolismo , Exossomos/transplante , Tecido Adiposo/citologia , Tecido Adiposo/metabolismo , Fígado/metabolismo , Fígado/patologia , Proliferação de Células , Traumatismo por Reperfusão/terapia , Traumatismo por Reperfusão/metabolismo , Hepatectomia , Citocinas/metabolismo , Masculino
15.
J Neurochem ; 166(2): 215-232, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37284938

RESUMO

Abnormal activation of the extrasynaptic N-methyl-d-aspartate receptor (NMDAR) contributes to the pathogenesis of Alzheimer's disease (AD). Ceftriaxone (Cef) can improve cognitive impairment by upregulating glutamate transporter-1 and promoting the glutamate-glutamine cycle in an AD mouse model. This study aimed to investigate the effects of Cef on synaptic plasticity and cognitive-behavioral impairment and to unravel the associated underlying mechanisms. We used an APPswe/PS1dE9 (APP/PS1) mouse model of AD in this study. Extrasynaptic components from hippocampal tissue homogenates were isolated using density gradient centrifugation. Western blot was performed to evaluate the expressions of extrasynaptic NMDAR and its downstream elements. Intracerebroventricular injections of adeno-associated virus (AAV)-striatal enriched tyrosine phosphatase 61 (STEP61 ) and AAV-STEP61 -shRNA were used to modulate the expressions of STEP61 and extrasynaptic NMDAR. Long-term potentiation (LTP) and Morris water maze (MWM) tests were performed to evaluate the synaptic plasticity and cognitive function. The results showed that the expressions of GluN2B and GluN2BTyr1472 in the extrasynaptic fraction were upregulated in AD mice. Cef treatment effectively prevented the upregulation of GluN2B and GluN2BTyr1472 expressions. It also prevented changes in the downstream signals of extrasynaptic NMDAR, including increased expressions of m-calpain and phosphorylated p38 MAPK in AD mice. Furthermore, STEP61 upregulation enhanced, whereas STEP61 downregulation reduced the Cef-induced inhibition of the expressions of GluN2B, GluN2BTyr1472 , and p38 MAPK in the AD mice. Similarly, STEP61 modulation affected Cef-induced improvements in induction of LTP and performance in MWM tests. In conclusion, Cef improved synaptic plasticity and cognitive behavioral impairment in APP/PS1 AD mice by inhibiting the overactivation of extrasynaptic NMDAR and STEP61 cleavage due to extrasynaptic NMDAR activation.


Assuntos
Doença de Alzheimer , Camundongos , Animais , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/metabolismo , Ceftriaxona/farmacologia , Ceftriaxona/uso terapêutico , Modelos Animais de Doenças , Plasticidade Neuronal/fisiologia , Cognição , Camundongos Transgênicos , Receptores de N-Metil-D-Aspartato/metabolismo
16.
NMR Biomed ; 36(2): e4843, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36264245

RESUMO

Osteoarthritis is a common chronic degenerative disease that causes pain and disability with increasing incidence worldwide. The osteochondral junction is a dynamic region of the joint that is associated with the early development and progression of osteoarthritis. Despite the substantial advances achieved in the imaging of cartilage and application to osteoarthritis in recent years, the osteochondral junction has received limited attention. This is primarily related to technical limitations encountered with conventional MR sequences that are relatively insensitive to short T2 tissues and the rapid signal decay that characterizes these tissues. MR sequences with ultrashort echo time (UTE) are of great interest because they can provide images of high resolution and contrast in this region. Here, we briefly review the anatomy and function of cartilage, focusing on the osteochondral junction. We also review basic concepts and recent applications of UTE MR sequences focusing on the osteochondral junction.


Assuntos
Imageamento por Ressonância Magnética , Osteoartrite , Humanos , Imageamento por Ressonância Magnética/métodos , Osteoartrite/diagnóstico por imagem , Fatores de Tempo , Imageamento Tridimensional/métodos
17.
NMR Biomed ; : e4939, 2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-36965076

RESUMO

The purpose of the current study was to investigate the effects of B0 and linear eddy currents on ultrashort echo time double echo steady state (UTE-DESS) imaging and to determine whether eddy current correction (ECC) effectively resolves imaging artifacts caused by eddy currents. 3D UTE-DESS sequences based on either projection radial or spiral cones trajectories were implemented on a 3-T clinical MR scanner. An off-isocentered thin-slice excitation approach was used to measure eddy currents. The measurements were repeated four times using two sets of tested gradient waveforms with opposite polarities and two different slice locations to measure B0 and linear eddy currents simultaneously. Computer simulation was performed to investigate the eddy current effect. Finally, a phantom experiment, an ex vivo experiment with human synovium and ankle samples, and an in vivo experiment with human knee joints, were performed to demonstrate the effects of eddy currents and ECC in UTE-DESS imaging. In a computer simulation, the two echoes (S+ and S-) in UTE-DESS imaging exhibited strong distortion at different orientations in the presence of B0 and linear eddy currents, resulting in both image degradation as well as misalignment of pixel location between the two echoes. The same phenomenon was observed in the phantom, ex vivo, and in vivo experiments, where the presence of eddy currents degraded S+, S-, echo subtraction images, and T2 maps. The implementation of ECC dramatically improved both the image quality and image registration between the S+ and S- echoes. It was concluded that ECC is crucial for reliable morphological and quantitative UTE-DESS imaging.

18.
Eur Radiol ; 33(7): 4842-4854, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36814033

RESUMO

OBJECTIVE: To assess the detection of changes in knee cartilage and meniscus of amateur marathon runners before and after long-distance running using a 3D ultrashort echo time MRI sequence with magnetization transfer preparation (UTE-MT). METHODS: We recruited 23 amateur marathon runners (46 knees) in this prospective cohort study. MRI scans using UTE-MT and UTE-T2* sequences were performed pre-race, 2 days post-race, and 4 weeks post-race. UTE-MT ratio (UTE-MTR) and UTE-T2* were measured for knee cartilage (eight subregions) and meniscus (four subregions). The sequence reproducibility and inter-rater reliability were also investigated. RESULTS: Both the UTE-MTR and UTE-T2* measurements showed good reproducibility and inter-rater reliability. For most subregions of cartilage and meniscus, the UTE-MTR values decreased 2 days post-race and increased after 4 weeks of rest. Conversely, the UTE-T2* values increased 2 days post-race and decreased after 4 weeks. The UTE-MTR values in lateral tibial plateau, central medial femoral condyle, and medial tibial plateau showed a significant decrease at 2 days post-race compared to the other two time points (p < 0.05). By comparison, no significant UTE-T2* changes were found for any cartilage subregions. For meniscus, the UTE-MTR values in medial posterior horn and lateral posterior horn regions at 2 days post-race were significantly lower than those at pre-race and 4 weeks post-race (p < 0.05). By comparison, only the UTE-T2* values in medial posterior horn showed a significant difference. CONCLUSIONS: UTE-MTR is a promising method for the detection of dynamic changes in knee cartilage and meniscus after long-distance running. KEY POINTS: • Long-distance running causes changes in the knee cartilage and meniscus. • UTE-MT monitors dynamic changes of knee cartilage and meniscal non-invasively. • UTE-MT is superior to UTE-T2* in monitoring dynamic changes in knee cartilage and meniscus.


Assuntos
Cartilagem Articular , Menisco , Corrida , Humanos , Reprodutibilidade dos Testes , Estudos Prospectivos , Articulação do Joelho/diagnóstico por imagem , Menisco/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cartilagem Articular/diagnóstico por imagem
19.
Eur Radiol ; 33(6): 3995-4006, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36571604

RESUMO

OBJECTIVES: To comprehensively assess osteoporosis in the lumbar spine, a compositional MR imaging technique is proposed to quantify proton fractions for all the water components as well as fat in lumbar vertebrae measured by a combination of a 3D short repetition time adiabatic inversion recovery prepared ultrashort echo time (STAIR-UTE) MRI and IDEAL-IQ. METHODS: A total of 182 participants underwent MRI, quantitative CT, and DXA. Lumbar collagen-bound water proton fraction (CBWPF), free water proton fraction (FWPF), total water proton fraction (TWPF), bone mineral density (BMD), and T-score were calculated in three vertebrae (L2-L4) for each subject. The correlations of the CBWPF, FWPF, and TWPF with BMD and T-score were investigated respectively. A comprehensive diagnostic model combining all the water components and clinical characteristics was established. The performances of all the water components and the comprehensive diagnostic model to discriminate between normal, osteopenia, and osteoporosis cohorts were also evaluated using receiver operator characteristic (ROC). RESULTS: The CBWPF showed strong correlations with BMD (r = 0.85, p < 0.001) and T-score (r = 0.72, p < 0.001), while the FWPF and TWPF showed moderate correlations with BMD (r = 0.65 and 0.68, p < 0.001) and T-score (r = 0.47 and 0.49, p < 0.001). The high area under the curve values obtained from ROC analysis demonstrated that CBWPF, FWPF, and TWPF have the potential to differentiate the normal, osteopenia, and osteoporosis cohorts. At the same time, the comprehensive diagnostic model shows the best performance. CONCLUSIONS: The compositional MRI technique, which quantifies CBWPF, FWPF, and TWPF in trabecular bone, is promising in the assessment of bone quality. KEY POINTS: • Compositional MR imaging technique is able to quantify proton fractions for all the water components (i.e., collagen-bound water proton fraction (CBWPF), free water proton fraction (FWPF), and total water proton fraction (TWPF)) in the human lumbar spine. • The biomarkers derived from the compositional MR imaging technique showed moderate to high correlations with bone mineral density (BMD) and T-score and showed good performance in distinguishing people with different bone mass. • The comprehensive diagnostic model incorporating CBWPF, FWPF, TWPF, and clinical characteristics showed the highest clinical diagnostic capability for the assessment of osteoporosis.


Assuntos
Doenças Ósseas Metabólicas , Osteoporose , Humanos , Vértebras Lombares/diagnóstico por imagem , Osso Esponjoso/diagnóstico por imagem , Prótons , Osteoporose/diagnóstico por imagem , Densidade Óssea , Imageamento por Ressonância Magnética/métodos , Água , Colágeno , Absorciometria de Fóton/métodos
20.
Skeletal Radiol ; 52(11): 2149-2157, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36607355

RESUMO

Novel compositional magnetic resonance (MR) imaging techniques have allowed for both the qualitative and quantitative assessments of tissue changes in osteoarthritis, many of which are difficult to characterize on conventional MR imaging. Ultrashort echo time (UTE) and zero echo time (ZTE) MR imaging have not been broadly implemented clinically but have several applications that leverage contrast mechanisms for morphologic evaluation of bone and soft tissue, as well as biochemical assessment in various stages of osteoarthritis progression. Many of the musculoskeletal tissues implicated in the initiation and progression of osteoarthritis are short T2 in nature, appearing dark as signal has already decayed to its minimum when image sampling starts. UTE and ZTE MR imaging allow for the qualitative and quantitative assessments of these short T2 tissues (bone, tendon, calcified cartilage, meniscus, and ligament) with both structural and functional reference standards described in the literature [1-3]. This review will describe applications of UTE and ZTE MR imaging in musculoskeletal tissues focusing on its role in knee osteoarthritis. While the review will address tissue-specific applications of these sequences, it is understood that osteoarthritis is a whole joint process with involvement and interdependence of all tissues. KEY POINTS: • UTE MR imaging allows for the qualitative and quantitative evaluation of short T2 tissues (bone, calcified cartilage, and meniscus), enabling identification of both early degenerative changes and subclinical injuries that may predispose to osteoarthritis. • ZTE MR imaging allows for the detection of signal from bone, which has some of the shortest T2 values, and generates tissue contrast similar to CT, potentially obviating the need for CT in the assessment of osseous features of osteoarthritis.


Assuntos
Interpretação de Imagem Assistida por Computador , Osteoartrite do Joelho , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA