Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Methods ; 45(4): 255-61, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18554522

RESUMO

Brain mapping in the freely moving animal is useful for studying motor circuits, not only because it avoids the potential confound of sedation or restraints, but because activated brain states may serve to accentuate differences that only manifest partially while a subject is in the resting state. Perfusion or metabolic mapping using autoradiography allows one to examine changes in brain function at the circuit level across the entire brain with a spatial resolution (approximately 100 micro) appropriate for the rat or mouse brain, and a temporal resolution (seconds-minutes) sufficient for capturing acute brain changes. Here we summarize the application of these methods to the functional brain mapping of behaviors involving locomotion of small animals, methods for the three-dimensional reconstruction of the brain from autoradiographic sections, voxel based analysis of the whole brain, and generation of maps of the flattened rat cortex. Application of these methods in animal models promises utility in improving our understanding of motor function in the normal brain, and of the effects of neuropathology and treatment interventions such as exercise have on the reorganization of motor circuits.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Atividade Motora/fisiologia , Animais , Mapeamento Encefálico/instrumentação , Camundongos , Modelos Animais , Ratos
2.
Brain Res ; 1234: 32-43, 2008 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-18687316

RESUMO

A dilemma in behavioral brain mapping is that conventional techniques immobilize the subject, extinguishing all but the simplest behaviors. This is avoided if brain activation is imaged after completion of the behavior and tissue capture of the tracer. A single-pass flow tracer proposed for positron emission tomography (PET) is a radiolabeled copper(II) complex of pyruvaldehyde bis(N(4)-methylthiosemicarbazone), [Cu(64)]-PTSM. [Cu(64)]-PTSM reaches steady-state cerebral distribution more rapidly than the metabolic tracer [(18)F]-fluorodeoxyglucose, allowing imaging with substantially greater temporal resolution. Using dual-label autoradiography, this study compares the relative regional cerebral blood flow tracer distribution (CBF-TR) of [(64)Cu]-PTSM to that of the classic perfusion tracer [(14)C]-iodoantipyrine in a rat model during treadmill walking. Rats were exposed to continuous walking on a treadmill and compared to quiescent controls. [(64)Cu]-PTSM was bolus injected (iv) after 1 min, followed by a 5-minute uptake and subsequent bolus injection of [(14)C]-iodoantipyrine. CBF-TR was quantified by autoradiography and analyzed in the three-dimensionally reconstructed brain by statistical parametric mapping, as well as by region-of-interest analysis. A high homology was found between the [(64)Cu]-PTSM and [(14)C]-iodoantipyrine patterns of cerebral activation in cortical and subcortical regions. For white matter, however, [(64)Cu]-PTSM showed lower perfusion than [(14)Cu]-iodoantipyrine. [(64)Cu]-PTSM is a useful tracer for functional brain mapping in freely-moving subjects. Its application in conjunction with PET promises to increase our understanding of the neural circuitry of behaviors dependent on locomotion.


Assuntos
Antipirina/análogos & derivados , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Compostos Organometálicos , Compostos Radiofarmacêuticos , Tiossemicarbazonas , Animais , Autorradiografia , Mapeamento Encefálico , Córtex Cerebral/irrigação sanguínea , Processamento de Imagem Assistida por Computador , Masculino , Atividade Motora/fisiologia , Tomografia por Emissão de Pósitrons , Ratos , Ratos Sprague-Dawley , Caminhada/fisiologia
3.
Neurosci Lett ; 434(2): 179-84, 2008 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-18325664

RESUMO

We describe a method for the measurement, analysis and display of cerebral cortical data obtained from coronal brain sections of the adult rat. In this method, regions-of-interest (ROI) are selected in the cortical mantle in a semiautomated fashion using a radial grid overlay, spaced in 15 degrees intervals from the midline. ROI measurements of intensity are mapped on a flattened two-dimensional surface. Topographic maps of statistical significance at each ROI allow for the rapid viewing of group differences. Cortical z-scores are displayed with the boundaries of brain regions defined according to a standard atlas of the rat brain. This method and accompanying software implementation (Matlab, Labview) allow for compact data display in a variety of autoradiographic and histologic studies of the structure and function of the rat brain.


Assuntos
Mapeamento Encefálico/instrumentação , Mapeamento Encefálico/métodos , Córtex Cerebral/fisiologia , Software , Animais , Antipirina/análogos & derivados , Antipirina/farmacocinética , Autorradiografia , Radioisótopos de Carbono , Córtex Cerebral/diagnóstico por imagem , Cintilografia , Ratos
4.
Brain Res ; 1184: 96-107, 2007 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-17964551

RESUMO

Exercise training (ET) causes functional and morphologic changes in normal and injured brain. While studies have examined effects of short-term (same day) training on functional brain activation, less work has evaluated effects of long-term training, in particular treadmill running. An improved understanding is relevant as changes in neural reorganization typically require days to weeks, and treadmill training is a component of many neurorehabilitation programs. Adult, male rats (n=10) trained to run for 40 min/day, 5 days/week on a Rotarod treadmill at 11.5 cm/s, while control animals (n=10) walked for 1 min/day at 1.2 cm/s. Six weeks later, [(14)C]-iodoantipyrine was injected intravenously during treadmill walking. Regional cerebral blood flow-related tissue radioactivity was quantified by autoradiography and analyzed in the three-dimensionally reconstructed brain by statistical parametric mapping. Exercised compared to nonexercised rats demonstrated increased influence of the cerebellar-thalamic-cortical (CbTC) circuit, with relative increases in perfusion in deep cerebellar nuclei (medial, interposed, lateral), thalamus (ventrolateral, midline, intralaminar), and paravermis, but with decreases in the vermis. In the basal ganglia-thalamic-cortical circuit, significant decreases were noted in sensorimotor cortex and striatum, with associated increases in the globus pallidus. Additional significant changes were noted in the ventral pallidum, superior colliculus, dentate gyrus (increases), and red nucleus (decreases). Following ET, the new dynamic equilibrium of the brain is characterized by increases in the efficiency of neural processing (sensorimotor cortex, striatum, vermis) and an increased influence of the CbTC circuit. Cerebral regions demonstrating changes in neural activation may point to alternate circuits, which may be mobilized during neurorehabilitation.


Assuntos
Mapeamento Encefálico , Cerebelo/fisiologia , Córtex Cerebral/fisiologia , Plasticidade Neuronal/fisiologia , Condicionamento Físico Animal , Tálamo/fisiologia , Animais , Antipirina/análogos & derivados , Antipirina/metabolismo , Autorradiografia , Comportamento Animal , Circulação Cerebrovascular , Processamento de Imagem Assistida por Computador , Masculino , Modelos Biológicos , Vias Neurais/fisiologia , Ratos , Ratos Sprague-Dawley , Trítio/metabolismo
5.
Arterioscler Thromb Vasc Biol ; 21(7): 1244-50, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11451759

RESUMO

Lesion composition plays a significant role in atherosclerotic lesion instability and rupture. Current clinical techniques cannot fully characterize lesion composition or accurately identify unstable lesions. This study investigates the use of time-resolved fluorescence spectroscopy for unstable atherosclerotic lesion diagnosis. The fluorescence of human coronary artery samples was induced with nitrogen laser and detected in the 360- to 510-nm wavelength range. The samples were sorted into 7 groups according to the AHA classification: normal wall and types I, II(a) (fatty streaks), III (preatheroma), IV (atheroma), V(a) (fibrous), and V(b) (calcified) lesions. Spectral intensities and time-dependent parameters [average lifetime tau(f); decay constants: tau(1) (fast-term), tau(2) (slow-term), A(1) (fast-term amplitude contribution)] derived from the time-resolved spectra of coronary samples were used for tissue characterization. We determined that a few intensity values at longer wavelengths (>430 nm) and time-dependent parameters at peak emission region (390 nm) discriminate between all types of arterial samples except between normal wall and type I lesions. The lipid-rich lesions (more unstable) can be discriminated from fibrous lesions (more stable) on the basis of time-dependent parameters (lifetime and fast-term decay). We inferred that features of lipid fluorescence are reflected on lipid-rich lesion emission. Our results demonstrate that analysis of the time-resolved spectra may be used to enhance the discrimination between different grades of atherosclerotic lesions and provide a means of discrimination between lipid-rich and fibrous lesions.


Assuntos
Doença da Artéria Coronariana/patologia , Lasers , Metabolismo dos Lipídeos , Espectrometria de Fluorescência/métodos , Adolescente , Adulto , Idoso , Aorta/patologia , Criança , Vasos Coronários/patologia , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
6.
J Perinatol ; 35(6): 424-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25590219

RESUMO

OBJECTIVE: To evaluate the cardiovascular response to short-term prone positioning in neonates. STUDY DESIGN: In this prospective study, we continuously monitored heart rate (HR), stroke volume (SV) and cardiac output (CO) by electrical velocimetry in hemodynamically stable neonates in each of the following positions for 10 min: supine, prone and back-to-supine position. Skin blood flow (SBF) was also continuously assessed on the forehead or foot using Laser Doppler technology. Systemic vascular resistance (SVR) index was calculated as mean blood pressure (BP)/CO. Data were analyzed using repeated measures analysis of variance. RESULTS: Thirty neonates (gestational age: 35±4 weeks; postmenstrual age: 36±3 weeks) were enrolled. HR did not change in response to positioning. However, in prone position, SV, CO and SBF decreased and SVR index increased from 1.5±0.3 to 1.3±0.3 ml kg(-1) (mean ±s.d., P<0.01), 206±44 to 180±41 ml kg(-1) min(-1) (P<0.01), 0.54±0.30 to 0.44±0.29 perfusion units (P<0.01) and 0.25±0.06 to 0.30±0.07 mm Hg ml(-1) kg(-1) min(-1) (P<0.01), respectively. After placing the infants back-to-supine position, SV, CO, SBF and SVR index returned to baseline. The above pattern of cardiovascular changes was consistent in vast majority of the studied neonates. CONCLUSIONS: Short-term prone positioning is associated with decreased SV, CO and SBF and increased calculated SVR index.


Assuntos
Débito Cardíaco/fisiologia , Recém-Nascido/fisiologia , Decúbito Ventral/fisiologia , Resistência Vascular/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Fluxometria por Laser-Doppler , Masculino , Estudos Prospectivos , Pele/irrigação sanguínea , Volume Sistólico/fisiologia , Decúbito Dorsal/fisiologia
7.
J Cereb Blood Flow Metab ; 23(8): 925-32, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12902836

RESUMO

A dilemma in functional neuroimaging is that immobilization of the subject, necessary to avoid movement artifact, extinguishes all but the simplest behaviors. Recently, we developed an implantable microbolus infusion pump (MIP) that allows bolus injection of radiotracers by remote activation in freely moving, nontethered animals. The MIP is examined as a tool for brain mapping in rats during a locomotor task. Cerebral blood flow-related tissue radioactivity (CBF-TR) was measured using [14C]-iodoantipyrine with an indicator-fractionation method, followed by autoradiography. Rats exposed to walking on a treadmill, compared to quiescent controls, showed increases in CBF-TR in motor circuits (primary motor cortex, dorsolateral striatum, ventrolateral thalamus, midline cerebellum, copula pyramis, paramedian lobule), in primary somatosensory cortex mapping the forelimbs, hindlimbs and trunk, as well as in secondary visual cortex. These results support the use of implantable pumps as adjunct tools for functional neuroimaging of behaviors that cannot be elicited in restrained or tethered animals.


Assuntos
Antipirina/análogos & derivados , Mapeamento Encefálico/métodos , Teste de Esforço , Animais , Radioisótopos de Carbono , Bombas de Infusão Implantáveis , Masculino , Ratos , Ratos Sprague-Dawley
8.
J Appl Physiol (1985) ; 70(3): 998-1005, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2033015

RESUMO

The periodic variations of the pulmonary microvascular pressure during pulsatile perfusion were studied in isolated left lower lobes of canine lungs by the arterial occlusion (AO) and double occlusion (DO) techniques. Sixteen AO and eight DO maneuvers evenly distributed within the pump cycle were performed for each of four frequencies: 36, 54, 72, and 90 beats/min. Nearly identical microvascular pressure contours were reconstructed from the AO and DO maneuvers by relocating the measured occlusion pressures in time. These contours lagged behind the pulmonary arterial pressure waveform. Their amplitude decreased from 25 to 14% of the arterial pulse pressure as the pump frequency was increased from 36 to 90 beats/min. The modulus of the pressure transfer function at the site of arterial occlusion decreased as the frequency increased. The phase was negative for all frequencies and it approached -90 degrees for the higher frequencies. Vasoconstriction induced by serotonin resulted in an increase of the magnitude of the AO pressure contour that was nearly proportional to the increase of the pulmonary arterial pulse pressure. In contrast, elevation of the lobar venous pressure to 10 mmHg increased the amplitude of the AO pressure contour, whereas it slightly decreased the pulmonary arterial pulse pressure. These experiments demonstrate that the AO and DO pressures fluctuate markedly during pulsatile perfusion. Their oscillations would be indicative of the pulsatility in the pulmonary microvascular bed.


Assuntos
Circulação Pulmonar/fisiologia , Animais , Pressão Sanguínea/fisiologia , Cães , Técnicas In Vitro , Microcirculação/fisiologia , Fluxo Pulsátil/fisiologia , Resistência Vascular/fisiologia , Vasoconstrição/fisiologia
9.
J Appl Physiol (1985) ; 68(2): 761-9, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2318783

RESUMO

In isolated canine lung lobes perfused with a pulsatile pump, arterial occlusions were performed and the postocclusion arterial pressure profiles were analyzed to estimate the pulmonary capillary pressure. A solenoid valve interposed between the pump and the lobar artery was used to perform arterial occlusions at several instants equally distributed within a pressure cycle. Double occlusions were also accomplished by simultaneously activating the solenoid valve and clamping the venous outflow of the lung lobe. To analyze an arterial occlusion pressure profile, we computed the best monoexponential fit of the pressure decay over a short period of time after the occlusion maneuvers. Two estimates of the capillary pressure were derived from this analysis: 1) the extrapolation of the exponential fit to the instant of occlusion, and 2) the point at which the recorded pressure decay curve merges with the exponential fit. The pressures thus determined were compared with the double occlusion pressure that provided an independent estimate of the pulmonary capillary pressure. Our results show that, under a wide range of conditions, the estimates of the capillary pressure obtained from the arterial occlusion data are nearly equal to the double occlusion pressures. Additionally, we estimated the capillary pressure variations within a pressure cycle by examining the occlusion pressures sampled at different instants of the cycle. The pulsatility of the pulmonary microvascular pressure varied with the pump frequency as well as the state of arterial and venous vasoaction. These variations are consistent with the representation of the lung vasculature as a low-pass filter.


Assuntos
Pressão Sanguínea/fisiologia , Artéria Pulmonar/fisiologia , Circulação Pulmonar/fisiologia , Animais , Capilares/fisiologia , Constrição , Cães , Feminino , Masculino
10.
J Appl Physiol (1985) ; 63(3): 1142-6, 1987 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3654460

RESUMO

In eight tracheotomized adult rabbits placed in the supine position, we employed a catheter-tip piezoresistive pressure transducer to measure esophageal pressure (Pes) and assessed the validity of taking the changes in Pes to be the changes in pleural pressure (Ppl). We applied an occlusion test in which the tracheal cannula was occluded during either spontaneous inspiratory efforts or body surface oscillations ranging from 3 to 50 Hz. The relationship between Pes and airway opening pressure (Pao) was recorded. In all instances, the changes in Pes and Pao were virtually identical in both amplitude and phase. We conclude that, as evaluated by the occlusion test, a catheter-tip pressure transducer placed in the esophagus of rabbits can give adequate estimation of local pleural changes up to at least 50 Hz.


Assuntos
Esôfago/fisiologia , Pulmão/fisiologia , Pleura/fisiologia , Animais , Cateterismo , Oscilometria , Pressão , Coelhos
11.
J Appl Physiol (1985) ; 79(2): 389-97, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7592193

RESUMO

Diaphragm and latissimus dorsi muscle functions, histochemistries, and morphometries were studied in anesthetized male Yucatan minipigs with congestive heart failure (CHF) induced by supraventricular tachycardia (n = 5). Sham-operated animals served as a control group (n = 5). In CHF animals, transdiaphragmatic pressure measured during supramaximal phrenic stimulation was reduced by 40% at low frequencies (< or = 20 Hz) and by 60% at higher frequencies. Twitch amplitude and half-relaxation time were also decreased. The cross-sectional areas of type I, IIa, and IIb fibers were reduced in the diaphragm. The proportion of type I fibers increased, whereas type IIa fibers decreased. Succinate dehydrogenase activity was elevated in type IIa and IIb fibers, but diaphragmatic fatigability was not altered. CHF reduced latissimus dorsi isometric force by 40% for stimulation frequencies > or = 30 Hz. The cross-sectional area of latissimus dorsi type IIb fibers was decreased, but twitch characteristics, fiber type composition, succinate dehydrogenase activity, and fatigability were unchanged. Experimental CHF appears to cause greater intrinsic adaptive changes in the diaphragm compared with those in the latissimus dorsi in the minipig. For both muscles, reduced contractile function was associated with atrophy. Impaired performance of the diaphragm may also be attributed to an increase in the relative contribution of type I fibers to the total tension-generating capacity of the muscle and to the pathophysiological mechanisms underlying the shortened relaxation time of the twitch response.


Assuntos
Diafragma/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Músculo Esquelético/fisiopatologia , Adaptação Fisiológica , Animais , Diafragma/enzimologia , Diafragma/patologia , Eletrocardiografia , Insuficiência Cardíaca/enzimologia , Insuficiência Cardíaca/patologia , Hemodinâmica/fisiologia , Masculino , Contração Muscular/fisiologia , Fadiga Muscular/fisiologia , Fibras Musculares Esqueléticas/fisiologia , Músculo Esquelético/enzimologia , Músculo Esquelético/patologia , Tamanho do Órgão/fisiologia , Suínos , Porco Miniatura , Taquicardia Supraventricular/enzimologia , Taquicardia Supraventricular/patologia , Taquicardia Supraventricular/fisiopatologia
12.
J Appl Physiol (1985) ; 68(4): 1722-6, 1990 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2347810

RESUMO

In eight anesthetized and tracheotomized rabbits, we studied the transfer impedances of the respiratory system during normocapnic ventilation by high-frequency body-surface oscillation from 3 to 15 Hz. The total respiratory impedance was partitioned into pulmonary and chest wall impedances to characterize the oscillatory mechanical properties of each component. The pulmonary and chest wall resistances were not frequency dependent in the 3- to 15-Hz range. The mean pulmonary resistance was 13.8 +/- 3.2 (SD) cmH2O.l-1.s, although the mean chest wall resistance was 8.6 +/- 2.0 cmH2O.l-1.s. The pulmonary elastance and inertance were 0.247 +/- 0.095 cmH2O/ml and 0.103 +/- 0.033 cmH2O.l-1.s2, respectively. The chest wall elastance and inertance were 0.533 +/- 0.136 cmH2O/ml and 0.041 +/- 0.063 cmH2O.l-1.s2, respectively. With a linear mechanical behavior, the transpulmonary pressure oscillations required to ventilate these tracheotomized animals were at their minimal value at 3 Hz. As the ventilatory frequency was increased beyond 6-9 Hz, both the minute ventilation necessary to maintain normocapnia and the pulmonary impedance increased. These data suggest that ventilation by body-surface oscillation is better suited for relatively moderate frequencies in rabbits with normal lungs.


Assuntos
Ventilação de Alta Frequência , Pulmão/fisiologia , Mecânica Respiratória , Tórax/fisiologia , Resistência das Vias Respiratórias , Animais , Pletismografia , Coelhos , Transdutores de Pressão
13.
J Appl Physiol (1985) ; 67(3): 1032-40, 1989 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2793697

RESUMO

The thoracic trachea and the proximal portion of the major bronchi were imaged in five normal volunteers during a forced expiration maneuver using a cine-computer-tomography system. Sixteen images of two contiguous slices were obtained in less than 1 is while expiratory flow was recorded at the mouth. The area of the thoracic trachea decreased rapidly as flow rate rose to its maximum and the wave of collapse propagated distally. The compressive narrowing of both the pars membranacea and the ventrolateral wall was asymmetric. A contact area appeared between the posterior and the left lateral walls. In one subject the trachea was imaged during the entire maneuver with a lower scan frequency. By 725 ms after the beginning of the forced expiration, the area had first decreased to 15% of its initial value and then reincreased to 46% of its initial value. It stayed constant for the remainder of the maneuver. The measured maximum air velocity was greater than the estimated local wave velocity.


Assuntos
Traqueia/diagnóstico por imagem , Adulto , Brônquios/anatomia & histologia , Brônquios/fisiologia , Broncografia , Fluxo Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Respiração , Tomografia Computadorizada por Raios X , Traqueia/anatomia & histologia , Traqueia/fisiologia
14.
Neurosci Lett ; 354(1): 74-8, 2004 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-14698485

RESUMO

Most brain mapping techniques require immobilization of the subject, which extinguishes all but the simplest behaviors. We applied in freely moving rats an implantable microbolus infusion pump (MIP) which can be triggered by remote activation for the injection of the cerebral blood flow tracer [(14)C]iodoantipyrine during behavioral activation. Consistent with previous electrophysiological, metabolic and brain anatomic studies, CBF-related tissue radioactivity (CBF-TR) increased in acoustic cortex during a 1000 Hz/8000 Hz alternating tone. In response to an acute foot-shock, CBF-TR increased in visual cortex, parietal association cortex, and extended into primary motor cortex, and primary somatosensory cortex mapping the trunk. These results support the utility of implantable pumps as adjunct tools for studying cerebral activation during behavioral challenges in nontethered, nonrestrained animals.


Assuntos
Antipirina/análogos & derivados , Córtex Auditivo/fisiologia , Mapeamento Encefálico/métodos , Circulação Cerebrovascular , Estresse Fisiológico/fisiopatologia , Estimulação Acústica , Animais , Antipirina/farmacocinética , Córtex Auditivo/irrigação sanguínea , Córtex Auditivo/diagnóstico por imagem , Autorradiografia , Radioisótopos de Carbono , Eletrochoque , Masculino , Atividade Motora , Cintilografia , Ratos , Ratos Sprague-Dawley , Estresse Fisiológico/diagnóstico por imagem
15.
Photochem Photobiol ; 69(6): 713-21, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10378012

RESUMO

To study the photobleaching of the main fluorescent compounds of the arterial wall, we repeatedly measured the time-resolved fluorescence of elastin, collagen and cholesterol during 560 s of excitation with nitrogen laser pulses. Three fluence rate levels were used: 0.72, 7.25 and 21.75 microW/mm2. The irradiation-related changes of the fluorescence intensity and of the time-resolved fluorescence decay constants were characterized for the emission at 390, 430 and 470 nm. The fluorescence intensity at 390 nm decreased by 25-35% when the fluence delivered was 4 mJ/mm2, a common value in fluorescence studies of the arterial wall. Cholesterol fluorescence photobleached the most, and elastin fluorescence photobleached the least. Photobleaching was most intense at 390 nm and least intense at 470 nm such that the emission spectra of the three compounds were markedly distorted by photobleaching. The time-resolved decay constants and the fluorescence lifetime were not altered by irradiation when the fluence was below 4 mJ/mm2. The spectral distortions associated with photobleaching complicate the interpretation of arterial wall fluorescence in terms of tissue content in elastin, collagen and cholesterol. Use of the time-dependent features of the emission that are not altered by photobleaching should increase the accuracy of arterial wall analysis by fluorescence spectroscopy.


Assuntos
Artérias/química , Colesterol/efeitos da radiação , Colágeno/efeitos da radiação , Elastina/efeitos da radiação , Animais , Arteriosclerose/diagnóstico , Bovinos , Colesterol/química , Colágeno/química , Elastina/química , Corantes Fluorescentes , Técnicas In Vitro , Fotoquímica , Espectrometria de Fluorescência/instrumentação , Raios Ultravioleta
16.
Photochem Photobiol ; 71(2): 178-87, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10687392

RESUMO

The time-resolved fluorescence spectra of the main arterial fluorescent compounds were retrieved using a new algorithm based on the Laguerre expansion of kernels technique. Samples of elastin, collagen and cholesterol were excited with a pulsed nitrogen laser and the emission was measured at 29 discrete wavelengths between 370 and 510 nm. The expansion of the fluorescence impulse response function on the Laguerre basis of functions was optimized to reproduce the observed fluorescence emission. Collagen lifetime (5.3 ns at 390 nm) was substantially larger than that of elastin (2.3 ns) and cholesterol (1.3 ns). Two decay components were identified in the emission decay of the compounds. For collagen, the decay components were markedly wavelength dependent and hydration dependent such that the emission decay became shorter at higher emission wavelengths and with hydration. The decay characteristics of elastin and cholesterol were relatively unchanged with wavelength and with hydration. The observed variations in the time-resolved spectra of elastin, collagen and cholesterol were consistent with the existence of several fluorophores with different emission characteristics. Because the compounds are present in different proportions in healthy and atherosclerotic arterial walls, characteristic differences in their time-resolved emission spectra could be exploited to assess optically the severity of atherosclerotic lesions.


Assuntos
Artérias/química , Arteriosclerose/metabolismo , Colesterol/química , Colágeno/química , Elastina/química , Processamento de Imagem Assistida por Computador/métodos , Artérias/patologia , Humanos , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos , Fatores de Tempo
17.
J Photochem Photobiol B ; 65(2-3): 157-64, 2001 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-11809374

RESUMO

Indocyanine green (ICG) has been widely used in cardiovascular, hepatic, and ophthalmologic studies. Application of this fluorescent dye has been handicapped by its poor stability in solution and by the complex dependence of its fluorescence intensity on concentration. Noncovalent interactions between ICG and sodium polyaspartate (PASP) stabilize ICG fluorescence in aqueous solution, but the effect of PASP on ICG fluorescence in blood has not been described. The current study had two main goals: first, to characterize in vitro in blood the relationship between fluorescence intensity and concentration of ICG-PASP (ICG) and the stability of this relationship over time; second, to test a new phenomenological model describing the dependence of ICG fluorescence on concentration. Freshly-prepared ICG and ICG-PASP solutions produced the same fluorescence intensity over a wide range of concentrations (0.0005-0.1271 mg/ml). The peak fluorescence of ICG was reduced by 11% after 10 h and by 72% at 7 days. In contrast, the peak fluorescence intensity of ICG-PASP solutions was nearly unchanged for up to 14 days. The dependence of the fluorescence intensity on concentration was accurately represented by our model that accounted for the generation of fluorescence following light absorption, and for the reabsorption of the emitted fluorescence by ICG.


Assuntos
Corantes Fluorescentes/química , Verde de Indocianina/química , Peptídeos/química , Fluorescência , Modelos Químicos , Soluções
18.
J Perinatol ; 16(1): 31-4, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8869537

RESUMO

The reliability of pulse oximetry in neonates receiving inotropic drugs because of hypotension and microcirculatory perfusion failure has not been well documented. Signal loss of the pulse oximeter in adult patients receiving dopamine infusions has been reported. To evaluate the relationship between pulse oximeter oxygen saturation (SaO2) and co-oximeter directly measured oxygen saturation, we studied 30 infants in the first 4 days of life (birth weight 620 to 4285 gm, gestational age 26 to 43 weeks) receiving dopamine (30 patients) and dobutamine (10 infants). Infants had normal blood pressures at the time of the study. To minimize motion artifact a Nellcor N-200 (Nellcor Incorporated, Hayward, Calif.) oximeter with electrocardiographic synchronization was used. We compared pulse oximeter values with simultaneous arterial samples analyzed for oxygen saturation with an IL 282 co-oximeter (Instrumentation Laboratory, Inc., Lexington, Mass.). The values were corrected for spuriously elevated carboxyhemoglobin levels and fetal hemoglobin level was quantitatively measured. The partial pressure of oxygen at 90% hemoglobin saturation for each patient was calculated. The dosage of dopamine ranged from 4 to 28 micrograms/kg per minute and the dosage of dobutamine varied from 4 to 24 micrograms/kg per minute. Over a wide range of values for mean blood pressure (23 to 66 mm Hg), partial pressure of oxygen at 90% hemoglobin saturation (43.1 to 70.2 mm Hg), and oxygen saturation (SaO2 80% to 100%), linear regression analysis revealed a close correlation between pulse oximeter SaO2 and co-oximeter SaO2 values (r = 0.83, standard error of the estimate 2.2%, p < 0.0001). Our findings indicate that pulse oximetry can be used reliably for continuous oxygen monitoring in normotensive neonates with an SaO2 of 80% to 100% who are receiving dopamine and dobutamine.


Assuntos
Peso ao Nascer , Doenças Cardiovasculares/tratamento farmacológico , Dobutamina/uso terapêutico , Dopamina/uso terapêutico , Recém-Nascido , Oximetria , Doenças Cardiovasculares/sangue , Humanos , Oxigênio/sangue , Estudos Prospectivos
20.
Neuroimage ; 36(3): 755-73, 2007 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-17481921

RESUMO

To evaluate functional neuronal compensation after partial damage to the nigrostriatal system, we lesioned rats unilaterally in the striatum with 6-hydroxydopamine. Five weeks later, cerebral perfusion was mapped at rest or during treadmill walking using [(14)C]-iodoantipyrine. Regional CBF-related tissue radioactivity (CBF-TR) was quantified by autoradiography and analyzed by statistical parametric mapping and region-of- interest analysis. Lesions were confirmed by tyrosine hydroxylase immunohistochemistry and changes in rotational locomotor activity. Functional compensations were bilateral and differed at rest and during treadmill walking. Consistent with the classic view of striatopallidal connections, CBF-TR of lesioned compared to sham-lesioned rats increased in the ipsilateral subthalamic nucleus (STN) and internal globus pallidus, and decreased in the striatum and external globus pallidus. Contrary to the classic view, CBF-TR increased in the ipsilateral ventral lateral, ventral anterior thalamus and motor cortex, as well as in the central medial thalamus, midline cerebellum, and contralateral STN. During walking, perfusion decreased in lesioned compared to sham-lesioned rats across the ipsilateral striato-pallidal-thalamic-cortical motor circuit. Compensatory increases were seen bilaterally in the ventromedial thalamus and red nucleus, in the contralateral STN, anterior substantia nigra, subiculum, motor cortex, and in midline cerebellum. Enhanced recruitment of associative sensory areas was noted cortically and subcortically. Future models of compensatory changes after nigrostriatal damage need to address the effects of increased neural activity by residual dopaminergic neurons, interhemispheric interactions and differences between resting and locomotor states. Identification of sites at which functional compensation occurs may define useful future targets for neurorehabilitative or neurorestorative interventions in Parkinson's disease.


Assuntos
Dano Encefálico Crônico/fisiopatologia , Encéfalo/fisiopatologia , Lateralidade Funcional/fisiologia , Locomoção/fisiologia , Descanso/fisiologia , Anfetamina/farmacologia , Animais , Autorradiografia , Dano Encefálico Crônico/líquido cefalorraquidiano , Dano Encefálico Crônico/induzido quimicamente , Mapeamento Encefálico , Estimulantes do Sistema Nervoso Central/farmacologia , Cerebelo/fisiopatologia , Globo Pálido/fisiopatologia , Processamento de Imagem Assistida por Computador , Masculino , Modelos Neurológicos , Neostriado/fisiopatologia , Oxidopamina , Ratos , Ratos Sprague-Dawley , Núcleo Subtalâmico/fisiopatologia , Tirosina 3-Mono-Oxigenase/metabolismo , Caminhada/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA