Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Gastroenterology ; 146(1): 291-304.e1, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24355035

RESUMO

Pancreatic ductal adenocarcinoma is an aggressive malignancy with a high mortality rate. Proper determination of the extent of disease on imaging studies at the time of staging is one of the most important steps in optimal patient management. Given the variability in expertise and definition of disease extent among different practitioners as well as frequent lack of complete reporting of pertinent imaging findings at radiologic examinations, adoption of a standardized template for radiology reporting, using universally accepted and agreed on terminology for solid pancreatic neoplasms, is needed. A consensus statement describing a standardized reporting template authored by a multi-institutional group of experts in pancreatic ductal adenocarcinoma that included radiologists, gastroenterologists, and hepatopancreatobiliary surgeons was developed under the joint sponsorship of the Society of Abdominal Radiologists and the American Pancreatic Association. Adoption of this standardized imaging reporting template should improve the decision-making process for the management of patients with pancreatic ductal adenocarcinoma by providing a complete, pertinent, and accurate reporting of disease staging to optimize treatment recommendations that can be offered to the patient. Standardization can also help to facilitate research and clinical trial design by using appropriate and consistent staging by means of resectability status, thus allowing for comparison of results among different institutions.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Documentação/normas , Neoplasias Pancreáticas/diagnóstico por imagem , Radiologia/normas , Humanos , Tomografia Computadorizada por Raios X
2.
J Clin Ultrasound ; 43(8): 463-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25704133

RESUMO

OBJECTIVE: Our aim in this study was to evaluate the effect of the radiologist, technologist, and other examination-related factors on the frequency of recommendations for additional imaging (RAI) during sonographic (US) interpretation. METHODS: We retrospectively reviewed 719 US reports from a single academic medical center for the presence of RAI. All studies had been interpreted by one of three abdominal radiologists. Examinations were performed at an outpatient radiology facility with no onsite radiologist (n = 299) or at an inpatient emergency department or hospital-based outpatient setting that had an onsite radiologist (n = 420). Possible associations between the frequency of RAI and the presence of an onsite radiologist, location of the examination, body part or region imaged, patient age, technologist performing the exam, and radiologist reading the exam were evaluated. RESULTS: There were significant differences between each pair of radiologists in terms of overall frequency of RAI (p < 0.001) (radiologist 1: 12.0% [22/184]; radiologist 2: 21.6% [78/361]; and radiologist 3: 45.5% [79/174]). In addition, there were statistically significant differences in the frequency of RAI among studies scanned by the 10 different US technologists (13.6%-40.0%, p = 0.03). However, other factors such as patient age, patient sex, US unit, patient location, and radiologist location were not associated with the frequency of RAI (p = 0.15-0.93). CONCLUSIONS: The individual radiologist and technologist influenced the frequency of RAI for US examinations, whereas other examination-related factors did not. The observed substantial variability in RAI between radiologists and technologists warrants further study, with consideration of strategies to optimize RAI within US reports.


Assuntos
Diagnóstico por Imagem/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Ultrassonografia/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Radiology ; 270(1): 248-60, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24354378

RESUMO

Pancreatic ductal adenocarcinoma is an aggressive malignancy with a high mortality rate. Proper determination of the extent of disease on imaging studies at the time of staging is one of the most important steps in optimal patient management. Given the variability in expertise and definition of disease extent among different practitioners as well as frequent lack of complete reporting of pertinent imaging findings at radiologic examinations, adoption of a standardized template for radiology reporting, using universally accepted and agreed on terminology for solid pancreatic neoplasms, is needed. A consensus statement describing a standardized reporting template authored by a multi-institutional group of experts in pancreatic ductal adenocarcinoma that included radiologists, gastroenterologists, and hepatopancreatobiliary surgeons was developed under the joint sponsorship of the Society of Abdominal Radiologists and the American Pancreatic Association. Adoption of this standardized imaging reporting template should improve the decision-making process for the management of patients with pancreatic ductal adenocarcinoma by providing a complete, pertinent, and accurate reporting of disease staging to optimize treatment recommendations that can be offered to the patient. Standardization can also help to facilitate research and clinical trial design by using appropriate and consistent staging by means of resectability status, thus allowing for comparison of results among different institutions.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/normas , Adenocarcinoma/patologia , Carcinoma Ductal Pancreático/patologia , Consenso , Meios de Contraste , Humanos , Neoplasias Pancreáticas/patologia , Sociedades Médicas , Estados Unidos
4.
AJR Am J Roentgenol ; 200(2): 343-54, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23345356

RESUMO

OBJECTIVE: The purpose of this review is to outline the management guidelines for the care of patients with cystic pancreatic lesions. CONCLUSION: The guidelines are as follows: Annual imaging surveillance is generally sufficient for benign serous cystadenomas smaller than 4 cm and for asymptomatic lesions. Asymptomatic thin-walled unilocular cystic lesions smaller than 3 cm or side-branch intraductal papillary mucinous neoplasms should be followed up with CT or MRI at 6 and 12 months interval after detection. Cystic lesions with more complex features or with growth rates greater than 1 cm/year should be followed more closely or recommended for resection if the patient's condition allows surgery. Symptomatic cystic lesions, neoplasms with high malignant potential, and lesions larger than 3 cm should be referred for surgical evaluation. Endoscopic ultrasound with fine-needle aspiration (FNA) biopsy can be used preoperatively to assess the risk of malignancy.


Assuntos
Diagnóstico por Imagem , Cisto Pancreático/diagnóstico , Cisto Pancreático/terapia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/terapia , Guias de Prática Clínica como Assunto , Diagnóstico Diferencial , Humanos
5.
Curr Urol Rep ; 13(1): 55-62, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22068585

RESUMO

The introduction of dual-energy computed tomography systems (ie, scanners that can simultaneously acquire images at different energies) has significant and unique applications for urologists. Imaging data from these scanners can be used to evaluate composition of urinary calculi and, by "removing" iodine from an image, significantly decrease radiation dose to patients referred for hematuria. Further, the ability to create a virtual noncontrast image obviates the need for repeated scanning in patients with incidentally detected renal and adrenal masses. Finally, the ability to quantify the regional concentration of iodine in a renal neoplasm may provide a method to monitor effectiveness of therapy before size changes become apparent.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X/métodos , Doenças Urológicas/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
6.
Radiology ; 259(3): 767-74, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21467252

RESUMO

PURPOSE: To retrospectively evaluate the frequency of recommendations for additional imaging (RAIs) for important extracolonic findings and polyp prevalence among a cohort of seniors (age ≥ 65 years) and nonseniors (age < 65 years) undergoing low-dose computed tomographic (CT) colonography. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Four hundred fifty-four patients (204 nonseniors: mean age, 52 years; 250 seniors: mean age, 69 years) underwent CT colonography at an outpatient facility. Cases were prospectively reported by one of four abdominal radiologists with expertise in CT colonography. The dictated reports were reviewed to determine the frequency of polyps (≥6 mm), the number of extracolonic findings, and the number of RAIs generated. The Fisher exact test was used to compare the percentage of seniors and nonseniors with at least one reported polyp, with at least one extracolonic finding, as well as the frequency of RAIs. RESULTS: The percentage of patients with at least one reported polyp was 14.2% (29 of 204) for the nonsenior group and 13.2% (33 of 250) for seniors, which was not significantly different (P = .772). The percentage of patients with at least one extracolonic finding was 55.4% (113 of 204) for nonseniors and 74.0% (185 of 250) for seniors (P < .0001). The percentage of patients in which an RAI was suggested was 4.4% (nine of 204) for nonseniors and 6.0% (15 of 250) for seniors, which was not significantly different (P = .450). CONCLUSION: Extracolonic findings were more frequent in seniors than in nonseniors; however, there was no significant difference in the frequency of RAIs between the two groups. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11102144/-/DC1.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/estatística & dados numéricos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Pólipos do Colo/epidemiologia , Meios de Contraste , Diatrizoato de Meglumina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Retratamento/estatística & dados numéricos , Estudos Retrospectivos
7.
AJR Am J Roentgenol ; 196(6): W693-700, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606256

RESUMO

OBJECTIVE: The purpose of this study was to validate the utility of dual-source dual-energy MDCT in quantifying iodine concentration in a phantom and in renal masses. MATERIALS AND METHODS: A series of tubes containing solutions of varying iodine concentration were imaged with dual-source dual-energy MDCT. Iodine concentration was calculated and compared with known iodine concentration. Single-phase contrast-enhanced dual-source dual-energy MDCT data on 15 patients with renal lesions then were assessed independently by two readers. Dual-energy postprocessing was used to generate iodine-only images. Regions of interest were placed on the iodine image over the lesion and, as a reference, over the aorta, for recording of iodine concentration in the lesion and in the aorta. Another radiologist determined lesion enhancement by comparing truly unenhanced with contrast-enhanced images. Mixed-model analysis of variance based on ranks was used to compare lesion types (simple cyst, hemorrhagic cyst, enhancing mass) in terms of lesion iodine concentration and lesion-to-aorta iodine ratio. RESULTS: In the phantom study, there was excellent correlation between calculated and true iodine concentration (R(2) = 0.998, p < 0.0001). In the patient study, 13 nonenhancing (10 simple and three hyperdense cysts) and eight enhancing renal masses were evaluated in 15 patients. The lesion iodine concentration and lesion-to-aorta iodine ratio in enhancing masses were significantly higher than in hyperdense and simple cysts (p < 0.0001). CONCLUSION: Iodine quantification with dual-source dual-energy MDCT is accurate in a phantom and can be used to determine the presence and concentration of iodine in a renal lesion. Characterization of renal masses may be possible with a single dual-source dual-energy MDCT acquisition without unenhanced images or reliance on a change in attenuation measurements.


Assuntos
Iodo , Nefropatias/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
8.
Emerg Radiol ; 18(6): 539-44, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21887533

RESUMO

The purpose of this study is to investigate the clinical and CT findings in patients with symptomatic colonoscopy-induced splenic rupture, and to assess for common features among this cohort. Multi-center search yielded 11 adults with symptomatic splenic injury related to colonoscopy. Workup included abdominal CT in 10 (91%) cases and abdominal radiography in two patients (one patient had both). Colonoscopy findings, post-procedural course, and CT findings were systematically reviewed. Mean patient age was 62.2 years (range, 51-84 years); 8 (73%) of 11 were female. The majority (64%) of colonoscopies were for screening. No immediate complications were reported at optical colonoscopy; tortuosity/redundancy was noted in five cases. Except for a small (8 mm) polyp in one case and a large (10 mm) polyp in another, the remaining nine patients had either diminutive or no polyps. Only one patient presented with hemodynamic instability during post-colonoscopy recovery; the other ten had a delayed presentation ranging from 8 h to 8 days (mean, 2.1 days). All 11 patients presented with abdominal pain. CT was diagnostic for splenic injury with subcaspular and/or perisplenic hematoma in all ten CT cases. Hemoperitoneum was present in eight, visible splenic laceration in three cases, and splenic artery pseudoaneurysm in one case. Five patients underwent splenectomy (four emergent) and six patients were treated conservatively. Average hospital stay was 5.5 days (range, 3-10 days). Colonoscopy-induced splenic rupture characteristically presents as a delayed and often serious complication. In cases of apparent non-traumatic splenic hematoma or rupture at CT, eliciting a history of recent colonoscopy may identify the etiology.


Assuntos
Colonoscopia/efeitos adversos , Ruptura Esplênica/diagnóstico por imagem , Ruptura Esplênica/etiologia , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
9.
Pancreatology ; 10(6): 734-41, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21252588

RESUMO

PURPOSE: To determine the frequency of intraductal papillary mucinous neoplasm (IPMN) in patients with and without invasive ductal adenocarcinoma (IDAC). METHODS: 82 patients underwent pancreatectomy for pancreas adenocarcinoma. 68/82 subjects underwent at least one preoperative imaging study including CT (n = 43), MRI (n = 25), or both (n = 12). Imaging studies were retrospectively evaluated to determine if IPMN was present in the gland at a location distant from IDAC. In 183 different adult patients undergoing MRI for renal mass, images were evaluated to determine the frequency of IPMN. Fisher's exact test was used to test whether the prevalence of IPMN was greater among patients with pancreas cancer than those without. RESULTS: Five of 68 (7.3%) patients who underwent pancreatic resection for IDAC had IPMN at a site distant from the cancer. Two of 182 (1.1%) patients undergoing MRI for renal cancer had imaging evidence of IPMN. There was a significant difference (p = 0.017) in the prevalence of IPMN between patients with and without IDAC. The odds ratio for IPMN as a predictor of pancreas cancer was estimated as 7.18. CONCLUSION: IPMN occurs with increased frequency in patients with pancreas cancer as opposed to those without pancreas cancer. and IAP.


Assuntos
Adenocarcinoma Mucinoso/patologia , Adenocarcinoma Papilar/patologia , Carcinoma Ductal Pancreático/patologia , Neoplasias Primárias Múltiplas/patologia , Pâncreas/patologia , Adenocarcinoma Mucinoso/epidemiologia , Adenocarcinoma Mucinoso/cirurgia , Adenocarcinoma Papilar/epidemiologia , Adenocarcinoma Papilar/cirurgia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/epidemiologia , Carcinoma Ductal Pancreático/cirurgia , Comorbidade , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Neoplasias Primárias Múltiplas/epidemiologia , Neoplasias Primárias Múltiplas/cirurgia , New York/epidemiologia , Neoplasias Pancreáticas , Estudos Retrospectivos
10.
AJR Am J Roentgenol ; 194(1): W27-32, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20028887

RESUMO

OBJECTIVE: The purpose of this study was to determine whether the conspicuity of malignant tumors of the pancreas at dual-source dual-energy CT is better with 80-kVp acquisition than with 120-kVp acquisition simulated with a weighted average. MATERIALS AND METHODS: Fifteen patients with pancreatic adenocarcinoma underwent contrast-enhanced dual-source dual-energy CT. The abdominal diameter of all patients was 35 cm or less. Data were reconstructed as a weighted average of the 140- and 80-kVp acquisitions, simulating 120 kVp, and as a pure 80-kVp data set. A region-of-interest cursor was placed within the tumor and the adjacent normal parenchyma, and attenuation differences and contrast-to-noise ratios were calculated for pancreatic tumors at 80 kVp and with the weighted-average acquisition. The 80-kVp and weighted-average images were subjectively compared in terms of lesion conspicuity, image quality, and duct visualization. An exact Wilcoxon's matched pairs signed rank test was used to test whether differences in attenuation, contrast-to-noise ratio, and subjective assessment were greater at 80 kVp. RESULTS: The mean difference in attenuation for each pancreatic tumor and adjacent portion of normal pancreas was 83.27+/-29.56 (SD) HU at 80 kVp and 49.40+/-23.00 HU at weighted-average 120 kVp. Adenocarcinoma attenuation differences were significantly greater at 80 kVp than at 120 kVp (p=0.00006). Contrast-to-noise ratio was significantly higher at 80 kVp than at 120 kVp (p=0.00147). Subjective analysis showed lesion conspicuity (p=0.001) and duct visualization (p=0.0156) were significantly better on the 80-kVp images. CONCLUSION: At portal venous phase dual-source dual-energy CT, the conspicuity of malignant tumors of the pancreas is greater at 80 kVp than with weighted-average acquisition.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Abdominal , Estudos Retrospectivos , Estatísticas não Paramétricas
11.
Semin Ultrasound CT MR ; 31(4): 292-300, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20691929

RESUMO

Endovascular repair is increasingly considered a less-invasive alternative to open repair of abdominal aortic aneurysm. However, there are still many potential complications of endovascular repair, including endoleaks, graft migration, thrombosis, and fistula formation. Endoleak is the most common complication for which these patients undergo long-term imaging surveillance. Most centers acquire computed tomographic (CT) data before contrast administration and during an arterial and delayed phase of aortic enhancement after the administration of intravenous contrast material to optimize detection of endoleaks. Although this technique works well, the downside is significant patient radiation exposure. Although the carcinogenic risk of ionizing radiation because of CT exposure is low, it has been linked to an increase in the lifelong risk of developing fatal cancers. Furthermore, this risk is cumulative and increases with multiple radiation exposure, as is true in surveillance after endovascular repair. As a result, considerable research is being performed to optimize CT protocols in an effort to decrease radiation dose. One such approach is to image these patients with recently introduced dual source dual-energy CT system. Using this technique, virtual noncontrast data may be generated from a postcontrast acquisition which may obviate the routine acquisition of noncontrast acquisition, thus decreasing radiation dose. In this article, we discuss the role of dual energy CT imaging in evaluation of patients after endovascular repair of abdominal aortic aneurysm.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Doses de Radiação , Risco , Tomografia Computadorizada por Raios X/instrumentação
12.
Radiology ; 251(1): 77-84, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19332847

RESUMO

PURPOSE: To retrospectively evaluate the sensitivity and specificity of several morphologic findings that may be seen with cystic pancreatic lesions, in the diagnosis of pseudocyst at magnetic resonance (MR) imaging. MATERIALS AND METHODS: This study was institutional review board approved and HIPAA compliant. From January 1, 2005, to December 31, 2007, electronic radiology and pathology databases were searched to identify patients with pancreatic cystic neoplasms or pseudocysts who underwent pancreatic MR imaging. Twenty-two patients with cystic pancreatic neoplasms that were confirmed at surgical resection (n = 12) or endoscopic ultrasonography (US) with cystic fluid analysis (n = 10) were identified. Of 20 patients with pancreatic pseudocysts, seven had pseudocysts that were identified at pathologic resection and 13 had a clinical history of pancreatitis, with initial computed tomography (CT) revealing no pancreatic cyst and subsequent follow-up MR imaging depicting cystic lesions. Two abdominal radiologists independently and randomly evaluated each case for presence or absence of septa and internal dependent debris and for external cyst morphology on axial and coronal T2-weighted images and three-dimensional gradient-echo T1-weighted images obtained before and after intravenous contrast agent administration. Logistic regression for correlated data was used to assess the usefulness of internal debris, external morphology, and septa for differentiating cystic neoplasms from pseudocysts. RESULTS: The readers' assessments of the presence or absence of cystic debris were concordant for 40 (95%) of the 42 patients, with a kappa coefficient of 0.889, which indicated nearly perfect agreement. Thirteen (93%) of 14 lesions found to have debris by either or both readers were pseudocysts, and only one (4%) of the 22 cystic neoplasms had debris. Both readers were more likely to identify septa within cystic neoplasms than within pseudocysts; however, the difference was not significant for either reader. The readers were more likely to observe microlobulated morphology in cystic neoplasms than in pseudocysts, with the difference between these lesion types, in terms of prevalence of microlobulated morphology, exhibiting a trend toward-but not reaching-statistical significance (P = .0627). CONCLUSION: Presence of internal dependent debris appears to be a highly specific MR finding for the diagnosis of pancreatic pseudocyst.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Cisto Pancreático/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Pancreatite , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Radiology ; 252(2): 433-40, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19487466

RESUMO

PURPOSE: To qualitatively and quantitatively compare virtual nonenhanced (VNE) data sets derived from dual-energy (DE) computed tomography (CT) with true nonenhanced (TNE) data sets in the same patients and to calculate potential radiation dose reductions for a dual-phase renal multidetector CT compared with a standard triple-phase protocol. MATERIALS AND METHODS: This prospective study was approved by the institutional review board; all patients provided written informed consent. Seventy one men (age range, 30-88 years) and 39 women (age range, 22-87 years) underwent preoperative DE CT that included unenhanced, DE nephrographic, and delayed phases. DE CT parameters were 80 and 140 kV, 96 mAs (effective). Collimation was 14 x 1.2 mm. CT numbers were measured in renal parenchyma and tumor, liver, aorta, and psoas muscle. Image noise was measured on TNE and VNE images. Exclusion of relevant anatomy with the 26-cm field of view detector was quantified with a five-point scale (0 = none, 4 = >75%). Image quality and noise (1 = none, 5 = severe) and acceptability for VNE and TNE images were rated. Effective radiation doses for DE CT and TNE images were calculated. Differences were tested with a Student t test for paired samples. RESULTS: Mean CT numbers (+/- standard deviation) on TNE and VNE images, respectively, for renal parenchyma were 30.8 HU +/- 4.0 and 31.6 HU +/- 7.1, P = .29; liver, 55.8 HU +/- 8.6 and 57.8 HU +/- 10.1, P = .11; aorta, 42.1 HU +/- 4.1 and 43.0 HU +/- 8.8, P = .16; psoas, 47.3 HU +/- 5.6 and 48.1 HU +/- 9.3 HU, P = .38. No exclusion of the contralateral kidney was seen in 50 patients, less than 25% was seen in 43, 25%-50% was seen in 13, and 50%-75% was seen in four. Mean image noise was 1.71 +/- 0.71 for VNE and 1.22 +/- 0.45 for TNE (P < .001); image quality was 1.70 HU +/- 0.72 for VNE and 1.15 HU +/- 0.36 for TNE (P < .0001). In all but three patients radiologists accepted VNE images as replacement for TNE images. Mean effective dose for DE CT scans of the abdomen was 5.21 mSv +/- 1.86 and that for nonenhanced scans was 4.97 mSv +/- 1.43. Mean dose reduction by omitting the TNE scan was 35.05%. CONCLUSION: In patients with renal masses, DE CT can provide high-quality VNE data sets, which are a reasonable approximation of TNE data sets. Integration of DE scanning into a renal mass protocol will lower radiation exposure by 35%.


Assuntos
Carga Corporal (Radioterapia) , Neoplasias Renais/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
14.
Eur Radiol ; 19(1): 13-23, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18677487

RESUMO

Dual energy CT (DECT) is a new technique that allows differentiation of materials and tissues based on CT density values derived from two synchronous CT acquisitions at different tube potentials. With the introduction of a new dual source CT system, this technique can now be used routinely in abdominal imaging. Potential clinical applications include evaluation of renal masses, liver lesions, urinary calculi, small bowel, pancreas, and adrenal glands. In CT angiography of abdominal aortic aneurysms, dual energy CT techniques can be used to remove bones from the datasets, and virtual unenhanced images allow differentiation of contrast agent from calcifying thrombus in patients with endovascular stents. This review describes potential applications, practical guidelines, and limitations of dual energy CT in the abdomen.


Assuntos
Absorciometria de Fóton/métodos , Absorciometria de Fóton/tendências , Radiografia Abdominal/métodos , Radiografia Abdominal/tendências , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências , Europa (Continente) , Humanos , Projetos Piloto , Padrões de Prática Médica/tendências
15.
AJR Am J Roentgenol ; 192(3): W103-10, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19234237

RESUMO

OBJECTIVE: The purpose of this study was to identify the CT features of mucocele of the appendix coexisting with acute appendicitis and to determine whether this entity can be differentiated from acute appendicitis without mucocele. MATERIALS AND METHODS: CT scans of 70 patients (12 with acute appendicitis with mucocele, 29 with acute appendicitis without mucocele, 29 with a normal appendix) were retrospectively interpreted by two readers. The appendix was evaluated for maximal luminal diameter, cystic dilatation, luminal attenuation, appendicolith, mural calcification and enhancement, periappendiceal fat stranding, fluid, and lymphadenopathy. CT findings were compared by use of Mann-Whitney U and Fisher's exact tests. Receiver operating characteristics analysis was performed to assess the diagnostic utility of appendiceal luminal diameter in differentiating acute appendicitis with from that without coexisting mucocele. RESULTS: Cystic dilatation of the appendix and maximal luminal diameter achieved statistical significance (p < 0.05) for the diagnosis of acute appendicitis with mucocele. Mural calcification achieved statistical significance for one reader (p = 0.0049) and a statistical trend for the other (p < 0.1). A maximal luminal diameter greater than 1.3 cm had a sensitivity of 71.4%, specificity of 94.6%, and overall diagnostic accuracy of 88.2% for the diagnosis of acute appendicitis with mucocele. CONCLUSION: Although there is overlap with acute appendicitis without mucocele, CT features suggestive of coexisting mucocele in patients with acute appendicitis include cystic dilatation of the appendix, mural calcification, and a luminal diameter greater than 1.3 cm.


Assuntos
Apendicite/diagnóstico por imagem , Apêndice/diagnóstico por imagem , Mucocele/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Estatísticas não Paramétricas
16.
AJR Am J Roentgenol ; 192(1): 159-64, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19098196

RESUMO

OBJECTIVE: The purpose of our study was to determine whether gadolinium is necessary in the follow-up evaluation of pancreatic cystic lesions. MATERIALS AND METHODS: Fifty-six patients with pancreatic cystic lesions detected on initial MRI and who underwent follow-up MRI were identified. Mean cyst size was 1.9 cm, and mean follow-up was 9.1 months. MRI included multiacquisition T1- and T2-weighted sequences before contrast administration and 3D fat-suppressed T1-weighted images before and after gadolinium administration. Two radiologists independently reviewed the entire initial examination and follow-up MRI using only unenhanced T1- and T2-weighted sequences from the second examination. Each radiologist made one of three recommendations: 1, no follow-up necessary or follow-up imaging in 6-12 months; 2, cyst aspiration; or 3, cyst resection. Four weeks later, imaging studies were reevaluated with the contrast-enhanced images from the second examination. A second recommendation using the same outcomes was made. Interobserver and intraobserver variations for the same patient were summarized in terms of kappa coefficients and the percentage of times the decisions were concordant. A 95% CI for the percentage of times management decisions would change without and with gadolinium was calculated. RESULTS: Concordance between the two different readers for the interpretations (when using the same MRI interpretation technique for follow-up surveillance) was 87.5% with a kappa coefficient to assess interobserver variation of 0.075, suggesting only slight agreement between the two readers. However, treatment recommendations provided by a single reader with and without information from the contrast-enhanced images were discordant only 4.5% of the time. Recommendations were concordant without and with gadolinium 95.5% (107/112; kappa=0.67) of the time, suggesting substantial agreement. A retrospective consensus review of the five cases in which gadolinium effected a change in the observer's recommendation was performed. There was nothing on the gadolinium-enhanced sequences that would specifically alter a change in a management decision, and it is likely that the changes in management decisions in these five cases were simply related to expected variations in categorizing lesions rather than to the use of gadolinium. CONCLUSION: The use of gadolinium has minimal impact in the follow-up MR assessment of pancreatic cystic lesions.


Assuntos
Gadolínio DTPA , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Pâncreas/patologia , Cisto Pancreático/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
AJR Am J Roentgenol ; 193(1): 207-13, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19542415

RESUMO

OBJECTIVE: The purpose of this study was to evaluate morphologic features predictive of benign thyroid nodules. MATERIALS AND METHODS: From a registry of the records of 1,232 fine-needle aspiration biopsies performed jointly by the cytology and radiology departments at a single institution between 2005 and 2007, the cases of 650 patients were identified for whom both a pathology report and ultrasound images were available. From the alphabetized list generated, the first 500 nodules were reviewed. We analyzed the accuracy of individual sonographic features and of 10 discrete recognizable morphologic patterns in the prediction of benign histologic findings. RESULTS: We found that grouping of thyroid nodules into reproducible patterns of morphology, or pattern recognition, rather than analysis of individual sonographic features, was extremely accurate in the identification of benign nodules. Four specific patterns were identified: spongiform configuration, cyst with colloid clot, giraffe pattern, and diffuse hyperechogenicity, which had a 100% specificity for benignity. In our series, identification of nodules with one of these four patterns could have obviated more than 60% of thyroid biopsies. CONCLUSION: Recognition of specific morphologic patterns is an accurate method of identifying benign thyroid nodules that do not require cytologic evaluation. Use of this approach may substantially decrease the number of unnecessary biopsy procedures.


Assuntos
Algoritmos , Inteligência Artificial , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia , Adulto Jovem
18.
Radiology ; 249(2): 692-700, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18812561

RESUMO

PURPOSE: To evaluate the possible radiation dose reduction facilitated by using dual-energy (DE) multidetector computed tomography (CT) after endovascular repair of abdominal aortic aneurysms (AAAs). MATERIALS AND METHODS: This prospective study was HIPAA compliant and institutional review board approved. Twenty-two patients who previously had undergone endovascular repair of AAAs underwent 24 DE multidetector CT examinations, which were performed with a 64-detector scanner. Initial nonenhanced CT was followed by arterial phase and venous phase acquisitions. Virtual nonenhanced, pure 80-kVp, and weighted-average peak voltage CT data sets were generated from the venous acquisition. Two independent readers interpreted the virtual nonenhanced and DE weighted-average CT data for the presence or absence of endoleaks. These interpretations were compared with the clinical interpretations of the data performed by a different radiologist by using true nonenhanced, arterial phase, and venous phase data. Region-of-interest measurements of the abdominal aorta and of the region of the endoleaks were obtained. Effective radiation dose was calculated. RESULTS: Both independent readers' interpretations of the virtual nonenhanced and weighted-average venous CT data revealed six type II endoleaks. There were no false-positive or false-negative findings. Aortic attenuation during the arterial, 80-kVp venous, and weighted-average data acquisitions were 288, 213, and 150 HU, respectively. The attenuation of the endoleaks was higher during the 80-kVp acquisition (P < .03) than during the arterial phase and weighted-average venous phase acquisitions. The mean effective dose for DE venous phase CT was 11.1 mSv compared with 27.8 mSv for standard triple-phase CT with a single-source configuration. CONCLUSION: Preliminary observations suggest that obtaining DE multidetector CT data by using a single 60-second contrast material-enhanced acquisition may be all that is required for surveillance after endovascular repair of AAA.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
19.
Vasc Endovascular Surg ; 42(1): 69-73, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18238872

RESUMO

The goal of endovascular repair of an abdominal aortic aneurysm is to exclude the aneurysm from systemic arterial pressure, thereby preventing rupture. However, the long-term durability of endovascular repair continues to be in question, as aneurysm rupture after endovascular repair continues to be reported. We report the case of an 89-year-old patient who underwent endovascular repair of a 7.1-cm abdominal aortic aneurysm with an Ancure endograft 5 years earlier. Despite close follow-up and a shrinking aneurysm sac on annual contrast-enhanced computed tomography, he presented with aneurysm rupture and a new proximal type I endoleak. The endoleak and rupture were successfully repaired with endovascular placement of a main body extension.


Assuntos
Aneurisma Roto/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Idoso de 80 Anos ou mais , Meios de Contraste , Evolução Fatal , Humanos , Masculino , Reoperação , Tomografia Computadorizada por Raios X
20.
Clin Gastroenterol Hepatol ; 5(11): 1306-12, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17689294

RESUMO

BACKGROUND & AIMS: Racial/ethnic minorities are less likely than whites to undergo colorectal cancer (CRC) screening. Although computed tomography colonography (CTC) is a less invasive alternative to optical colonoscopy (OC), it is not known whether CTC will increase acceptance of CRC screening in minorities. METHODS: Patients undergoing OC for clinically indicated reasons had CTC followed by same-day OC. After the sedation from the OC had worn off, a questionnaire was administered to assess pain, discomfort, bloating, embarrassment, anxiety, and patient satisfaction using a 10-point scale (1 = least, 10 = greatest). RESULTS: Of the 272 patients enrolled, there were 134 whites, 71 blacks, 53 Hispanics, and 14 who self-identified their race/ethnicity as other. Although the proportion of subjects who preferred CTC over OC was not significantly different (52.9% vs 47.1%, P = .36), racial/ethnic minorities were significantly less likely than whites to prefer CTC over OC (whites, 65.7%; blacks, 45.1%; Hispanics, 35.8%; and other, 35.7%; P < .001). Racial/ethnic minorities were less satisfied with CTC (whites, 8.4 +/- 1.7; blacks, 7.8 +/- 1.7; Hispanics, 7.4 +/- 1.8; and other, 7.5 +/- 2.1; P = .001) and were significantly less willing to undergo CTC again in the future (whites, 95.5%; blacks, 80.3%; Hispanics, 84.9%; and other, 85.7%; P = .006). CONCLUSIONS: Compared with white patients, OC is better tolerated and is preferred over CTC for evaluation of the colon among racial/ethnic minorities. Although CTC is less invasive than OC, our findings suggest that CTC is unlikely to overcome racial/ethnic disparities in CRC screening.


Assuntos
Colonografia Tomográfica Computadorizada , Colonoscopia/métodos , Satisfação do Paciente , Grupos Raciais/estatística & dados numéricos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , New York , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA