Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Echocardiography ; 41(1): e15698, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284664

RESUMO

BACKGROUND: Transaortic valve implant (TAVI) is the treatment of choice for severe aortic stenosis (AS). Some patients develop prosthesis patient mismatch (PPM) after TAVI. It is challenging to determine which patients are at risk for clinical deterioration. METHODS: We retrospectively measured echocardiographic parameters of left ventricular (LV) morphology and function, prosthetic aortic valve effective orifice area (iEOA) and hemodynamics in 313 patients before and 1 year after TAVI. Our objective was to compare the change in echocardiographic parameters associated with left ventricular reverse modeling in subjects with and without PPM. Our secondary objective was to evaluate echo parameters associated with PPM and the relationship to patient functional status and survival post-TAVI. RESULTS: We found that 82 (26.2%) of subjects had moderate and 37 (11.8%) had severe PPM post-TAVI. There was less relative improvement in LVEF with PPM (1.9 ± 21.3% vs. 8.2 + 30.1%, p = .045). LV GLS also exhibited less relative improvement in those with PPM (13.4 + 34.1% vs. 30.9 + 73.3%, p = .012). NYHA functional class improved in 84.3% of subjects by one grade or more. Echocardiographic markers of PPM were worse in those without improvement in NYHA class (mean AT/ET was .29 vs. .27, p = .05; DVI was .46 vs. .51, p = .021; and iEOA was .8 cm/m2 vs. .9 cm/m2 , p = .025). There was no association with PPM and survival. CONCLUSIONS: There was no improvement in LVEF and less improvement in LV GLS in those with PPM post-TAVI. Echocardiographic markers of PPM were present in those with lack of improvement in NYHA functional class.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Remodelação Ventricular , Resultado do Tratamento , Ecocardiografia
2.
J Magn Reson Imaging ; 57(1): 126-136, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35633284

RESUMO

BACKGROUND: Aortopathy is common with bicuspid aortic valve (BAV), and underlying intrinsic tissue abnormalities are believed causative. Valve-mediated hemodynamics are altered in BAV and may contribute to aortopathy and its progression. The contribution of intrinsic tissue defects versus altered hemodynamics to aortopathy progression is not known. PURPOSE: To investigate relative contributions of tissue-innate versus hemodynamics in progression of BAV aortopathy. STUDY TYPE: Retrospective. SUBJECTS: Four hundred seventy-three patients with aortic dilatation (diameter ≥40 mm; comprised of 281 BAV with varied AS severity, 192 tricuspid aortic valve [TAV] without AS) and 124 healthy controls. Subjects were 19-91 years (141/24% female). FIELD STRENGTH/SEQUENCE: 1.5T, 3T; time-resolved gradient-echo 3D phase-contrast (4D flow) MRI. ASSESSMENT: A surrogate measure for global aortic wall stiffness, pulse wave velocity (PWV), was quantified from MRI by standardized, automated technique based on through-plane flow cross-correlation maximization. Comparisons were made between BAV patients with aortic dilatation and varying aortic valve stenosis (AS) severity and healthy subjects and aortopathy patients with normal TAV. STATISTICAL TESTS: Multivariable regression, analysis of covariance (ANCOVA), Tukey's, student's (t), Mann-Whitney (U) tests, were used with significance levels P < 0.05 or P < 0.01 for post-hoc Bonferroni-corrected t/U tests. Bland-Altman and ICC calculations were performed. RESULTS: Multivariable regression showed age with the most significant association for increased PWV in all groups (increase 0.073-0.156 m/sec/year, R2  = 0.30-48). No significant differences in aortic PWV were observed between groups without AS (P = 0.20-0.99), nor were associations between PWV and regurgitation or Sievers type observed (P = 0.60, 0.31 respectively). In contrast, BAV AS patients demonstrated elevated PWV and a significant relationship for AS severity with increased PWV (covariate: age, R2  = 0.48). BAV and TAV patients showed no association between aortic diameter and PWV (P = 0.73). DATA CONCLUSION: No significant PWV differences were observed between BAV patients with normal valve function and control groups. However, AS severity and age in BAV patients were directly associated with PWV increases. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 3.


Assuntos
Doenças da Aorta , Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Feminino , Masculino , Valva Aórtica/diagnóstico por imagem , Análise de Onda de Pulso , Doenças das Valvas Cardíacas/diagnóstico por imagem , Estudos Retrospectivos , Estenose da Valva Aórtica/complicações , Doença da Válvula Aórtica Bicúspide/complicações , Doenças da Aorta/diagnóstico por imagem , Hemodinâmica
3.
J Thromb Thrombolysis ; 55(4): 691-699, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36781619

RESUMO

Chronic thromboembolic pulmonary hypertension (CTEPH) is a treatable complication of acute pulmonary embolism (PE). Identification of factors that impact referral to a comprehensive CTEPH center may improve disease awareness and patient outcomes. We conducted a study of patients with acute PE. Cases were identified through a natural language processing algorithm. ICD coding was used to assess clinical documentation for dyspnea or CTEPH placed at least 90 days after their acute PE diagnosis. We analyzed characteristics of patients who were referred vs. not referred, as well as referral patterns for "at risk" patients. 2454 patients with acute PE were identified, of which 4.9% (120/2454) were referred for CTEPH evaluation. Patients who were not referred were older (61 vs. 54 years, p < 0.001), had higher rates of cancer (28% vs. 10%, p < 0.001), and lived further from the referral center (9.1 miles vs. 6.7 miles, p = 0.03). Of 175 patients identified as "at risk," 12% (21/175) were referred. In the 'at risk' cohort, distance from referral center among referred and not referred was significant (5.7 miles vs. 8.8 miles, p = 0.04). There were low rates of referral to CTEPH center in post-PE patients, and in patients with symptoms who may be at higher risk of CTEPH. Age, co-morbid conditions, distance from comprehensive center, and presence of a primary care provider contribute to differences in referral to a comprehensive CTEPH center. Clinician education about CTEPH is important to ensure optimal care to patients with or at risk for chronic complications of acute PE.


Assuntos
Hipertensão Pulmonar , Neoplasias , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia , Doença Aguda , Neoplasias/complicações , Encaminhamento e Consulta , Doença Crônica
4.
Echocardiography ; 38(11): 1932-1940, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34747056

RESUMO

BACKGROUND: Pulmonary thromboendarterectomy (PTE) is a curative procedure for chronic thromboembolic pulmonary hypertension (CTEPH). Right ventricular free wall strain (RV FWS) and right atrial strain (RAS) are not well studied in a CTEPH population. We sought to determine temporal trends in RAS and RV FWS in patients post-PTE. METHODS: 28 patients undergoing PTE for CTEPH were prospectively enrolled in a surgical database. Comprehensive echocardiographic assessment of the right heart was performed including RV FWS, right atrial volume, and the three components of RAS: reservoir, conduit, and booster strain. RESULTS: Patients undergoing PTE demonstrated improvement in NYHA functional class (P < 0.001). Hemodynamic assessment showed improvement in mean pulmonary artery pressure from 49.7 ± 8.5 mm Hg to 23.9 ± 6.5 mm Hg (P < 0.001) and pulmonary vascular resistance decreased from 7.8 ± 3.2 wu to 2.4 ± 1.3 wu (P < 0.001). Tricuspid annular plane systolic excursion (TAPSE) and lateral S` declined immediately post-op. RV FWS improved from -14.4 ± 4% to -19 ± 3.4% post-op and -21.2 ± 4.7% at long-term follow-up (P < 0.001). Improvement in RV FWS post-op was driven primarily by increases in the apical and mid segments. RA volume declined significantly during the study period. RA reservoir and conduit strain improved after PTE. CONCLUSION: Patients undergoing PTE for CTEPH had significant improvement in right heart hemodynamics immediately post-op. Traditional echo metrics of RV performance including TAPSE and lateral S` did not improve. RV FWS improved, which was driven by changes in the apical and mid segments. This highlights that RV FWS is a viable and useful metric to follow in CTEPH patients post-PTE.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Disfunção Ventricular Direita , Endarterectomia , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/cirurgia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/cirurgia , Resistência Vascular , Função Ventricular Direita
5.
J Card Surg ; 36(1): 89-96, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33170533

RESUMO

OBJECTIVE: Surgical reoperation for aortic homograft structural valve degeneration (SVD) is a high-risk procedure. Transcatheter aortic valve replacement (TAVR) for homograft-SVD is an alternative to reoperation, but descriptions of implantation techniques are limited. This study compares outcome in patients undergoing into two groups by the type of previously implanted aortic valve prosthesis: TAVR for failed aortic homografts (TAVR-H) or for stented aortic bioprostheses (TAVR-BP). METHODS: From 2015 to 2017, TAVR was performed in 41 patients with SVD. Thirty-three patients in the TAVR-BP group (six for SVD of valved conduits), and eight patients in the TAVR-H group. The Valve Academic Research Consortium criteria were used for outcome reporting purposes. RESULTS: The patients with TAVR-BP had predominant prosthetic stenosis (94%, p = .002), whereas TAVR-H individuals presented mostly with regurgitation (88%, p = <.001). Patients with TAVR-H received: Sapien-3 (6), Sapien-XT (1), and CoreValve (1) devices. Low, 40% ventricular fixation in relation to homograft annulus was attempted to anchor the prosthesis on the homograft suture-line. One patient with TAVR-BP experienced intraoperative distal prosthesis migration and Type-B aortic dissection, and two patients in the TAVR-H group had late postoperative proximal device migration. In both groups, there was zero 30-day mortality, stroke, or pacemaker implantation. CONCLUSIONS: TAVR for failing aortic homografts may be a feasible and safe alternative to high-risk surgical reintervention. Precise, 40%-ventricular device positioning appears crucial for prevention of late paravalvular leak/late prosthesis migration and minimizing the risk of repeat surgical intervention.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aloenxertos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-38950772

RESUMO

OBJECTIVE: Aortic root replacement requires construction of a composite valve-graft and reimplantation of coronary arteries. This study assessed the feasibility of valve-in-valve transcatheter aortic valve implantation after aortic root replacement. METHODS: A retrospective review was conducted on 74 consecutive patients who received a composite valve-graft at a single institution from 2019 to 2021. Forty patients had bioprosthetic valves with adequate postoperative gated computed tomographic angiography scans. Computational simulations of balloon and self-expanding transcatheter valve deployments were performed. The modeled coronary distances were compared to traditional, manually measured valve-to-coronary distances. RESULTS: There was a statistically significant difference in the modeled versus manual measurements of valve to coronary distances were for all patients regardless of valve type or coronary artery analyzed (p <0. 05). Most patients are low risk for coronary obstruction per three-dimensional modeling including those with a valve-to-coronary distance <4 millimeters. Only one patient (2.5%) was at risk for coronary obstruction for the left coronary artery using a ballonvalve. No other valve combination was considered high risk of coronary obstruction. Five patients (12.5%) were at risk for possible valve stent deformation at the outflow, due to angulation at the graft anastomosis. CONCLUSIONS: Following aortic root replacement, all patients were candidates for Valve-in-Valve using one or both types of transcatheter heart valves. Self-expanding valves may be at higher risk for stent frame deformation at graft anastomotic lines and balloon-expandable valves may be at higher risk of coronary obstruction.

7.
Ann Cardiothorac Surg ; 13(3): 275-282, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38841084

RESUMO

Background: The desire of patients to avoid anticoagulation, together with the potential of valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR), have resulted in the increasing use of bioprosthetic valves for aortic valve replacement (AVR). While patient-prosthesis mismatch (PPM) is known to be an adverse risk after AVR, few studies have addressed the effect of PPM on valve durability. This study evaluates the role of valve size and hemodynamics on long term durability after AVR with a Magna bioprosthesis. Methods: We performed a retrospective, single-center evaluation of patients who underwent a surgical AVR procedure between June 2004 through December 2022 using the Magna bioprosthesis. Perioperative information and long-term follow-up data were sourced from the institution's Society for Thoracic Surgeons Adult Cardiac Surgery Registry and outcomes database. Cumulative incidence of freedom from reintervention were estimated accounting for competing events. Group comparisons used Gray's test. Results: Among 2,100 patients, the mean patient age was 69 years (range, 22-95 years), of whom 98% had native aortic valve disease, 32.5% had concomitant coronary bypass grafting, and 19% had mitral valve surgery. Median follow-up was 5.8 (1.9-9.4) years, during which 116 reinterventions were performed, including 74 explants and 42 VIV procedures. Nine hundred and twenty-eight patients died prior to reintervention. Incidence of all cause reintervention was 1.2%, 4.5%, and 11.7% at 5, 10, and 15 years, respectively. Smaller valve size was associated with worse survival (P<0.001), but not with reintervention. Higher mean gradient at implant was associated with increased late reintervention [sub-distribution hazard ratio: 1.016; 95% confidence interval (CI): 1.005 to 1.028; P=0.0047, n=1,661]. Conclusions: While reintervention rates are low for the Magna prosthesis at 15 years, the analysis is confounded by the competing risk of death. PPM, as reflected physiologically by elevated post-operative valve gradients, portends an increased risk of intervention. Further study is necessary to elucidate the mechanism of early stenosis in patients who progress to reintervention.

8.
JACC Asia ; 4(4): 292-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38660112

RESUMO

Background: Sex-related disparities in clinical outcomes following transcatheter aortic valve replacement (TAVR) and the impact of sex on clinical outcomes after TAVR among different racial groups are undetermined. Objectives: This study assessed whether sex-specific differences in baseline clinical and anatomical characteristics affect clinical outcomes after TAVR and investigated the impact of sex on clinical outcomes among different racial groups. Methods: The TP-TAVR (Trans-Pacific TAVR) registry is a multinational cohort study of patients with severe aortic stenosis who underwent TAVR at 2 major centers in the United States and 1 major center in South Korea. The primary outcome was a composite of death from any cause, stroke, or rehospitalization after 1 year. Results: The incidence of the primary composite outcome was not significantly different between sexes (27.9% in men vs 28% in women; adjusted HR: 0.97; 95% CI: 0.79-1.20). This pattern was consistent in Asian (23.5% vs 23.3%; adjusted HR: 0.99; 95% CI: 0.69-1.41) and non-Asian (30.8% vs 31.6%; adjusted HR: 0.95; 95% CI: 0.72-1.24) cohorts, without a significant interaction between sex and racial group (P for interaction = 0.74). The adjusted risk for all-cause mortality was similar between sexes, regardless of racial group. However, the adjusted risk of stroke was significantly lower in male patients than in female patients, which was more prominent in the non-Asian cohort. Conclusions: Despite significantly different baseline and procedural characteristics, there were no sex-specific differences in the adjusted 1-year rates of primary composite outcomes and all-cause mortality, regardless of different racial groups. (Transpacific TAVR registry [TP-TAVR]; NCT03826264).

9.
JTCVS Tech ; 20: 130-137, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37555027

RESUMO

Objective: Sternal dehiscence is frequently associated with wire-based closures cutting through fragile bone, allowing sternal motion, separation, and infection. We investigated whether bone cutting could be limited by using a newly available mesh suture with improved force distribution. Methods: Five sternal models were closed using 8 interrupted single sternal wires, double sternal wires, braided poly(ethylene terephthalate) sutures, single-wrapped mesh sutures, or double-wrapped mesh sutures. To simulate chest-wall forces, closed sternal models were pulled apart using 1020 N of axial force applied incrementally. Double sternal wire and double-wrapped mesh suture were further compared by closing 3 new models with each material and subjecting these models to cyclic loading cycles, simulating breathing and coughing. Image analysis of needle hole size measured "bone cutting" by each closure material and sternal distraction as a function of force. Results: All models exhibited maximal separation at the xiphoid. During axial loading, needle hole size increased 7.2% in the double-wrapped mesh suture model and 9.2% in the double-wire model. Single-wrapped mesh suture, single wires, and braided poly(ethylene terephthalate) extended needle hole size by 6.7%, 47.0%, and 168.3% of original size, respectively. The double-wire model resisted sternal distraction best, separating 0.285 cm at the xiphoid. During cyclic loading, mesh suture exhibited significantly less bone cutting (P = .02) than double wire, with comparable levels of sternal separation (P = .07). Conclusions: Mesh suture may resist bone cutting seen in sternal wire closure in bone models with comparable distraction to currently used sternal closure methods.

10.
JTCVS Tech ; 20: 24-29, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37555046

RESUMO

Objective: HAART 300 300 (BioStable Science and Engineering, Inc) aortic annuloplasty rings restore physiologic annular geometry during aortic valve repair. Transcatheter valve-in-ring implantation is appealing for recurrent valve dysfunction but may necessitate balloon fracture of downsized annuloplasty rings. We characterized the feasibility of ring fracture and changes in ring geometry preceding fracture. Methods: The 19-mm, 21-mm, and 23-mm HAART 300 annuloplasty rings were obtained, and 23-mm, 24-mm, 25-mm, and 26-mm valvuloplasty balloons were obtained. Under continuous fluoroscopy and video recording, a 23-mm balloon was inflated within a 19-mm ring at 1 atm/s until ring fracture or balloon failure occurred. If balloon failure occurred, experiments were sequentially repeated with 1-mm upsized balloons until ring fracture occurred or no larger-sized balloons were available. Results: Upon balloon inflation, all rings exhibited an irreversible conformational change from an elliptical, annular geometry to a circular shape with ring posts flaring outward. A 23-mm balloon burst at 21 atm without fracturing the 19-mm ring. The 24-mm balloon fractured the 19-mm ring at 15 atm. Likewise, a 24-mm balloon ruptured at 18 atm without fracturing the 21-mm annuloplasty ring. A 25-mm balloon fractured the 21-mm ring at 18 atm. Finally, a 26-mm balloon burst at 20 atm without fracturing a 23-mm annuloplasty ring, but it did elicit the confirmational changes described. All fractures occurred along the upslope of a ring post. The exposed metal frame was visible after the 21-mm ring fracture. Conclusions: Fracture of HAART 300 aortic annuloplasty rings is possible with an oversized, high-pressure balloon. However, the geometrical changes in the ring and subsequent rupture of its fabric covering may be obstacles to safe, in vivo ring fracture.

11.
Front Cardiovasc Med ; 10: 1256420, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38034383

RESUMO

This study aims to assess whether the On-X aortic valved conduit better restores normal valvular and ascending aortic hemodynamics than other commonly used bileaflet mechanical valved conduit prostheses from St. Jude Medical and Carbomedics by using same-day transthoracic echocardiography (TTE) and 4D flow magnetic resonance imaging (MRI) examinations. TTE and 4D flow MRI were performed back-to-back in 10 patients with On-X, six patients with St. Jude (two) and Carbomedics (four) prostheses, and 36 healthy volunteers. TTE evaluated valvular hemodynamic parameters: transvalvular peak velocity (TPV), mean and peak transvalvular pressure gradient (TPG), and effective orifice area (EOA). 4D flow MRI evaluated the peak systolic 3D viscous energy loss rate (VELR) density and mean vorticity magnitude in the ascending aorta (AAo). While higher TPV and mean and peak TPG were recorded in all patients compared to healthy subjects, the values in On-X patients were closer to those in healthy subjects (TPV 1.9 ± 0.3 vs. 2.2 ± 0.3 vs. 1.2 ± 0.2 m/s, mean TPG 7.4 ± 1.9 vs. 9.2 ± 2.3 vs. 3.1 ± 0.9 mmHg, peak TPG 15.3 ± 5.2 vs. 18.9 ± 5.2 vs. 6.1 ± 1.8 mmHg, p < 0.001). Likewise, while higher VELR density and mean vorticity magnitude were recorded in all patients than in healthy subjects, the values in On-X patients were closer to those in healthy subjects (VELR: 50.6 ± 20.1 vs. 89.8 ± 35.2 vs. 21.4 ± 9.2 W/m3, p < 0.001) and vorticity (147.6 ± 30.0 vs. 191.2 ± 26.0 vs. 84.6 ± 20.5 s-1, p < 0.001). This study demonstrates that the On-X aortic valved conduit may produce less aberrant hemodynamics in the AAo while maintaining similar valvular hemodynamics to St. Jude Medical and Carbomedics alternatives.

12.
JACC Cardiovasc Interv ; 16(13): 1579-1589, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37438025

RESUMO

BACKGROUND: Transcatheter tricuspid valve repair (TTVr) has significantly expanded treatment options for tricuspid regurgitation (TR). However, a sizeable proportion of patients are still declined for TTVr and little is known about their clinical characteristics and cardiac morphology. OBJECTIVES: This study sought to characterize patients who screen fail for TTVr with respect to their clinical characteristics and cardiac morphology. METHODS: A total of 547 patients were evaluated for TTVr between January 2016 to December 2021 from 3 centers in the United States and Germany. Clinical records and echocardiographic studies were used to assess medical history and right ventricular (RV) and tricuspid valve (TV) characteristics. RESULTS: Median age was 80 (IQR: 74-83) years and 60.0% were female. Over half (58.1%) were accepted for TTVr. Of those who were deemed unsuitable for TTVr (41.9%), the most common exclusion reasons were anatomical criteria (56.8%). In the regression analysis, RV and right atrial size, TV coaptation gap, and tethering area were identified as independent screen failure predictors. Other rejection reasons included clinical futility (17.9%), low symptom burden (12.7%), and technical limitations (12.7%). Most of the excluded patients (71.6%) were managed conservatively with medical therapy, while a small number either proceeded to TV surgery (22.3%) or subsequently became eligible for transcatheter tricuspid valve replacement in later available clinical trials in the United States (6.1%). CONCLUSIONS: The majority of TTVr screen failure patients are excluded due to TV, right atrial, and RV enlargement. However, a significant proportion is excluded due to clinical futility. These identifiable anatomical and clinical characteristics emphasize the importance of earlier referral and intervention of TR and the need for continued innovation of Transcatheter tricuspid valve interventions.


Assuntos
Apêndice Atrial , Ecocardiografia , Ventrículos do Coração , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Apêndice Atrial/diagnóstico por imagem , Estados Unidos , Alemanha , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem
13.
JACC Asia ; 3(3): 376-387, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37323869

RESUMO

Background: Interracial differences in the distribution and prognostic value of conventional Society of Thoracic Surgeons (STS) score on long-term mortality after transcatheter aortic valve replacement (TAVR) are uncertain. Objectives: This study aims to compare the impact of STS scores on clinical outcomes at 1-year after TAVR between Asian and non-Asian populations. Methods: We used the Trans-Pacific TAVR (TP-TAVR) registry, a multinational multicenter, observational registry involving patients undergoing TAVR at 2 major centers in the United States and 1 major center in Korea. Patients were classified into 3 groups (low, intermediate, and high-risk) according to the STS score and compared between STS risk groups and race. The primary outcome was all-cause mortality at 1-year. Results: Among 1,412 patients, 581 were Asian and 831 were non-Asian. The distribution of the STS risk score group was different between Asian and non-Asian groups (62.5% low-, 29.8% intermediate-, and 7.7% high-risk in Asian vs 40.6% low-, 39.1% intermediate-, and 20.3% high-risk in non-Asian). In the Asian population, the all-cause mortality at 1-year was substantially higher in the high-risk STS group than in the low- and intermediate-risk groups (3.6% low-risk, 8.7% intermediate-risk, and 24.4% high-risk; log-rank P < 0.001), which was primarily driven by noncardiac mortality. In the non-Asian group, there was a proportional increase in all-cause mortality at 1-year according to the STS risk category (5.3% low-risk, 12.6% intermediate-risk, and 17.8% high-risk; log-rank P < 0.001). Conclusions: In this multiracial registry of patients with severe aortic stenosis who underwent TAVR, we identified a differential proportion and prognostic impact of STS score on 1-year mortality between Asian and non-Asian patients (TP-TAVR [Transpacific TAVR Registry]; NCT03826264).

14.
J Thorac Cardiovasc Surg ; 166(5): e182-e331, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37389507

RESUMO

AIM: The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS: A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. STRUCTURE: Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.


Assuntos
Doenças da Aorta , Doença da Válvula Aórtica Bicúspide , Cardiologia , Feminino , Gravidez , Estados Unidos , Humanos , American Heart Association , Doenças da Aorta/diagnóstico , Doenças da Aorta/terapia , Aorta
15.
Heart ; 108(19): 1562-1570, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-35110384

RESUMO

OBJECTIVE: Little information exists about inter-racial differences in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). We investigated whether differences in baseline characteristics between Asian and non-Asian population may contribute to disparities in clinical outcomes after TAVI. METHODS: We performed a registry-based, multinational cohort study of patients with severe AS who underwent TAVI at two centres in the USA and one centre in South Korea. The primary outcome was a composite of death, stroke or rehospitalisation at 1 year. RESULTS: Of 1412 patients, 581 patients were Asian and 831 were non-Asian (87.5% white, 1.7% black, 6.1% Hispanic or 4.7% others). There were substantial differences in baseline characteristics between two racial groups. The primary composite outcome was significantly lower in the Asian group than in the non-Asian group (26.0% vs 35.0%; HR 0.73; 95% CI 0.59 to 0.89; p=0.003). However, after adjustment of baseline covariates, the risk of primary composite outcome was not significantly different (HR 0.79; 95% CI 0.60 to 1.03; p=0.08). The all-cause mortality at 1 year was significantly lower in the Asian group than the non-Asian group (7.4% vs 12.5%; HR 0.60; 95% CI 0.41 to 0.88; p=0.009). After multivariable adjustment, the risk of all-cause mortality was also similar (HR 1.17; 95% CI 0.73 to 1.88; p=0.52). CONCLUSIONS: There were significant differences in baseline and procedural factors among Asian and non-Asian patients who underwent TAVI. Observed inter-racial differences in clinical outcomes were largely explained by baseline differences in clinical, anatomical and procedural factors. TRIAL REGISTRATION NUMBER: NCT03826264 (https://wwwclinicaltrialsgov).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Humanos , Fatores Raciais , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
JACC Cardiovasc Interv ; 14(24): 2670-2681, 2021 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-34838464

RESUMO

OBJECTIVES: The aim of this study was to compare the incidence and prognostic significance of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) according to racial groups. BACKGROUND: PPM after TAVR may be of more concern in Asian populations considering their relatively small annular and valve sizes compared with Western populations. METHODS: TP-TAVR (Transpacific TAVR Registry) was an international multicenter cohort study of patients with severe aortic stenosis who underwent TAVR in the United States and South Korea from January 2015 to November 2019. PPM was defined as moderate (0.65-0.85 cm2/m2) or severe (<0.65 cm2/m2) at the indexed effective orifice area. The primary outcome was a composite of death, stroke, or rehospitalization at 1 year. RESULTS: Among 1,101 eligible patients (533 Asian and 569 non-Asian), the incidence of PPM was significantly lower in the Asian population (33.6%; moderate, 26.5%; severe, 7.1%) than in the non-Asian population (54.5%; moderate, 29.8%; severe, 24.7%). The 1-year rate of the primary outcome was similar between the PPM and non-PPM groups (27.5% vs 28.1%; P = 0.69); this pattern was consistent between Asian (25.4% vs 25.2%; P = 0.31) and non-Asian (28.7% vs 32.1%; P = 0.97) patients. After multivariable adjustment, the risk for the primary outcome did not significantly differ between the PPM and non-PPM groups in the overall population (HR: 0.95; 95% CI: 0.74-1.21), in Asian patients (HR: 1.07; 95% CI: 0.74-1.55), and in non-Asian patients (HR: 0.86; 95% CI: 0.63-1.19). CONCLUSIONS: In this study of patients with severe aortic stenosis who underwent TAVR, the incidence of PPM was significantly lower in Asian patients than in non-Asian patients. The 1-year risk for the primary composite outcome was similar between the PPM and non-PPM groups regardless of racial group. (Transpacific TAVR Registry [TP-TAVR]; NCT03826264).


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Incidência , Desenho de Prótese , Fatores Raciais , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologia
17.
Eur J Cardiothorac Surg ; 56(1): 204-205, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30561574

RESUMO

Transcatheter aortic valve implantation (TAVI) is a recognized treatment method for high-risk patients with aortic stenosis. TAVI is also recommended for structural valve degeneration of a biological valve prosthesis. TAVI-specific complications, such as prosthesis embolization and aortic dissection, are uncommon but potential concerns. A 73-year-old woman presented with structural valve degeneration 14 years after aortic root replacement with a bioprosthetic valved conduit. The patient underwent TAVI valve-in-valve under monitored anaesthesia care. Intraoperatively, the self-expandable prosthesis was difficult to deploy within the valved conduit and ultimately migrated distally. During the technically difficult passage of the prosthesis delivery system through the tortuous aorta, the patient started reporting symptoms suggestive of aortic dissection. An emergency computed tomography scan confirmed type B dissection. Thoracic endovascular aortic repair followed by deployment of a balloon-expandable prosthesis below the self-expandable implant was performed. Careful prosthesis selection in valve-in-valve patients after aortic root replacement is crucial for procedural success.


Assuntos
Dissecção Aórtica/cirurgia , Valva Aórtica/cirurgia , Embolização Terapêutica/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aorta/diagnóstico por imagem , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Próteses Valvulares Cardíacas , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA