RESUMO
BACKGROUND: Left ventricular assist device (L-VAD) implantation is increasingly used in patients with heart failure (HF) and most patients also have an implantable cardioverter defibrillator (ICD). Limited data are available on the incidence of ICD therapies and complications in this special setting. The aim of this study was to analyze the real-world incidence and predictors of ICD therapies, complications and interactions between ICD and L-VAD. METHODS: We conducted a multicenter retrospective observational study in patients with advanced HF implanted with ICD and a continuous-flow L-VAD, followed-up in five advanced HF centers in Northern Italy. RESULTS: A total of 234 patients (89.7% male, median age 59, 48.3% with ischemic etiology) were enrolled. After a median follow-up of 21 months, 66 patients (28.2%) experienced an appropriate ICD therapy, 22 patients (9.4%) an inappropriate ICD therapy, and 17 patients (7.3%) suffered from an interaction between ICD and L-VAD. The composite outcome of all ICD-related complications was reported in 41 patients (17.5%), and 121 (51.7%) experienced an L-VAD-related complication. At multivariable analysis, an active ventricular tachycardia (VT) zone and a prior ICD generator replacement were independent predictors of ICD therapies and of total ICD-related complications, respectively. CONCLUSIONS: Real-world patients with both L-VAD and ICD experience a high rate of ICD therapies and complications. Our findings suggest the importance of tailoring device programming in order to minimize the incidence of unnecessary ICD therapies, thus sparing the need for ICD generator replacement, a procedure associated to a high risk of complications.
Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Taquicardia Ventricular , Feminino , Humanos , Masculino , Arritmias Cardíacas/etiologia , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Pessoa de Meia-IdadeRESUMO
We report the first case of new technique of replacement of a Micra TPS, due to battery depletion. A 38-year-old patient was admitted due to battery depletion of a TPS, after 44 months of regular pacemaker functioning. After routine implantation of a new TPS, we use a snare loop inserted in the delivery system to capture the old TPS. We believe this approach a good option not to abandon the depleted device, to avoid possible electrical interference or space occupation in right ventricle. This new approach allows to change the strategy during procedure and does not increase significantly the procedure costs.
Assuntos
Remoção de Dispositivo , Marca-Passo Artificial , Adulto , Pré-Escolar , Morte , Humanos , Implantação de Prótese , Resultado do TratamentoRESUMO
We describe the echocardiographic finding of a 35-year-old pregnant woman, referred for a clinical consultation at our institution because of congestive heart failure. She underwent echocardiography with only little information about a history of cardiac surgery during infancy. At the first sight, parasternal long axis view demonstrates normal structures, but on the apical view we diagnosed a very rare condition with typical imaging findings: Criss Cross heart.
Assuntos
Coração Entrecruzado/diagnóstico por imagem , Ecocardiografia/métodos , Hidratação/efeitos adversos , Insuficiência Cardíaca/etiologia , Adulto , Diuréticos/uso terapêutico , Feminino , Furosemida/uso terapêutico , Coração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , GravidezAssuntos
Infecções por Coronavirus/fisiopatologia , Exercício Físico/fisiologia , Comportamentos Relacionados com a Saúde , Pneumonia Viral/fisiopatologia , Idoso , Betacoronavirus , COVID-19 , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Itália , Masculino , Pandemias , Quarentena , SARS-CoV-2RESUMO
BACKGROUND: Predicting an accessory pathway location is extremely important in pediatric patients. AIMS: We designed a study to compare previously published algorithms by Arruda, Boersma, and Chiang. METHODS: This multicenter study included patients who had undergone successful ablation of one accessory pathway. Analysis of resting 12-lead electrocardiograms was carried out. An aggregated prediction score was constructed on the basis of algorithm agreement, and a structured workflow approach was proposed. RESULTS: The total population was 120 patients (mean age, 12.7 [± 3.6] years). The algorithm by Boersma had the highest accuracy (71.7%). The inter-rater agreement among the 3 reference algorithms, according to left-sided accessory pathway (AP) identification, was good between Boersma and Chiang (κ = 0.611; 95% confidence interval [CI], 0.468-0.753) but moderate between Arruda and Chiang and between Arruda and Boersma (κ = 0.566; 95% CI, 0.419-0.713 and κ = 0.582; 95% CI, 0.438-0.727, respectively). Regarding locations at risk of atrioventricular (AV) block, agreement was fair between Arruda and Chiang and between Boersma and Chiang (κ = 0.358; 95% CI, 0.195-0.520 and κ = 0.307; 95% CI, 0.192-0.422, respectively) but moderate between Arruda and Boersma (κ = 0.45; 95% CI, 0.304-0.597). On applying a first-step diagnostic evaluation, when concordance was achieved, we were able to correctly identify left-sided or non-left-sided ablation sites in 96.4% (n = 80) of cases. When concordance was achieved, correct prediction of risk/no risk of AV block was achieved in 92.2% (n = 59) of cases. CONCLUSIONS: An aggregated prediction score based on 3 reference algorithms proved able to predict an accessory pathway location very precisely and could be used to plan safely invasive procedures.
Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Síndrome de Wolff-Parkinson-White , Feixe Acessório Atrioventricular/cirurgia , Algoritmos , Fascículo Atrioventricular/cirurgia , Ablação por Cateter/métodos , Criança , Eletrocardiografia/métodos , Humanos , Síndrome de Wolff-Parkinson-White/diagnósticoRESUMO
BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.
Assuntos
Bloqueio Atrioventricular , COVID-19 , Controle de Infecções , Complicações Pós-Operatórias , Implantação de Prótese , SARS-CoV-2/isolamento & purificação , Síndrome do Nó Sinusal , Idoso , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/terapia , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/terapia , Comorbidade , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Saúde Global/estatística & dados numéricos , Humanos , Controle de Infecções/instrumentação , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Masculino , Pessoa de Meia-Idade , Mortalidade , Avaliação de Resultados em Cuidados de Saúde , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Fatores de Risco , Síndrome do Nó Sinusal/epidemiologia , Síndrome do Nó Sinusal/terapia , Inquéritos e QuestionáriosRESUMO
A 67-year-old man with history of heart failure developed dyspnea. In this report, we describe an increase in his device-detected respiratory rate. Monitoring respiratory rate is recommended for evaluating acute cardiac decompensation, but such an algorithm could also be used to diagnose episodes of pneumonia caused by severe acute respiratory syndrome-coronavirus-2 infection. (Level of Difficulty: Intermediate.).
RESUMO
Patients with cardiac implantable electronic devices have usually been scheduled for routine inhospital visits. In addition, they are now monitored remotely. The remote monitoring of cardiac implantable electronic devices is a valuable tool to screen and triage patients at very high risk of deterioration. The continuous expansion of remote monitoring in realworld settings brought a substantial increase of published evidence on the topic. Therefore, this review aims to summarize challenges and knowledge gaps in the field. Challenges that were identified as issues to be solved comprise warranty of data security and accessibility, integration with clinical repositories, patient selection and persistence, and resource availability. Future improvements of telemedicine will need to face these significant residual challenges.
Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Telemedicina , Eletrônica , Humanos , Monitorização FisiológicaRESUMO
[Figure: see text].
Assuntos
Arritmias Cardíacas/epidemiologia , COVID-19/epidemiologia , Saúde Global/tendências , Idoso , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , COVID-19/mortalidade , COVID-19/terapia , Eletrofisiologia Cardíaca/tendências , Comorbidade , Técnicas Eletrofisiológicas Cardíacas/tendências , Feminino , Pesquisas sobre Atenção à Saúde , Disparidades em Assistência à Saúde , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica/tendências , Prevalência , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de TempoRESUMO
AIMS: An increased mortality risk during weekend hospital admission has been consistently observed. In the present study, we evaluated whether the current improvement in management of acute coronary syndromes (ACS) has reduced this phenomenon. METHODS AND RESULTS: We extracted data from the Italian National Healthcare System Databank of 80â391 ACS admissions in the region of Lombardia between 2010 and 2014. ICD-9 codes were used to assess the diagnosis. We performed a multiple logistic regression analysis to compare the mortality rates between weekend and weekday admissions.Mean age of the study population was 67.6 years; 30.1% of patients were women. ST segment elevation myocardial infarction (STEMI) accounts for 42.2% of admissions. The total in-hospital mortality was 3.05% and was positively predicted by weekend admission [odds ratio (OR) 1.13, Pâ=â0.006], age and female sex. The weekend effect on mortality was only significant for STEMI (OR 1.11, Pâ=â0.04) in comparison to non-STEMI (NSTEMI) or unstable angina.The trend of the risk of death was found to be negatively correlated with age: the risk of death was significantly higher in all age clusters younger than 75 (OR 1.22, Pâ<â0.01) and even greater in the very young subgroup under 45 years of age (OR 2.09, Pâ=â0.03). CONCLUSION: Our data indicate that increased mortality risk is still present during weekend admissions. This phenomenon is particularly evident in younger patients and in individuals admitted for STEMI.
Assuntos
Síndrome Coronariana Aguda/mortalidade , Plantão Médico , Mortalidade Hospitalar , Admissão do Paciente , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Adulto , Fatores Etários , Idoso , Angina Instável/diagnóstico , Angina Instável/mortalidade , Angina Instável/terapia , Estudos Transversais , Bases de Dados Factuais , Feminino , Humanos , Itália/epidemiologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Prognóstico , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Fatores Sexuais , Fatores de TempoRESUMO
A revised version of the European Society of Cardiology (ESC) and European Association for Cardio-Thoracic Surgery (EACTS) guidelines on myocardial revascularization has recently been published. These guidelines represent the third time that the ESC and EACTS have brought together cardiologists and cardiac surgeons in a joint Task Force to review the available evidence, with the mission of drafting balanced, patient-oriented, clinical practice guidelines on myocardial revascularization. During the last 4 years, a large body of evidence has become available and brought substantial changes to the guidelines. This paper aims to summarize what is new in the 2018 ESC/EACTS guidelines on myocardial revascularization.