Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Jpn J Clin Oncol ; 51(2): 205-212, 2021 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-33556170

RESUMO

PURPOSE: Computed tomography of the abdomen and pelvis is a useful imaging modality for identifying origin and extent of ovarian cancer before primary debulking surgery. However, the International Federation of Gynecology and Obstetrics staging for ovarian cancer is determined based on surgico-pathological findings. The purpose of this study is to determine whether computed tomography staging can be the surrogate for surgico-pathological International Federation of Gynecology and Obstetrics staging in advanced ovarian cancer undergoing neoadjuvant chemotherapy. METHODS: Computed tomography staging was compared with surgico-pathological International Federation of Gynecology and Obstetrics staging in primary debulking surgery arm patients in a randomized controlled trial comparing primary debulking surgery and neoadjuvant chemotherapy (JCOG0602). The cancer of primary debulking surgery arm was identically diagnosed regarding the origin and extent with the cancer of neoadjuvant chemotherapy arm before accrual, using imaging studies (computed tomography and/or magnetic resonance imaging), cytological examination (ascites, pleural effusion or tumor contents fluid) and tumor marker (CA125 > 200 U/mL and CEA < 20 ng/mL). Institutional computed tomography staging was also compared with computed tomography staging by central review. RESULTS: Among 149 primary debulking surgery arm patients, 147 patients who underwent primary debulking surgery immediately were analyzed. Positive predictive values and sensitivity of computed tomography staging for surgical stage III disease (extra-pelvic peritoneal disease and/or retroperitoneal lymph node metastasis) were 99%. Meanwhile, positive predictive values for the presence of small (≤2 cm) extra-pelvic peritoneal disease were low; <20% in omentum. Accuracy of institutional computed tomography staging was comparable with computed tomography staging by central review. CONCLUSIONS: Preoperative computed tomography staging in each institution can be the surrogate for surgico-pathological diagnosis in stage III disease of ovarian cancer patients undergoing neoadjuvant chemotherapy without diagnostic surgery, but reliability of diagnosis of stage IIIB disease is inadequate.Clinical trial registration: UMIN000000523(UMIN-CTR).


Assuntos
Neoplasias das Tubas Uterinas/diagnóstico por imagem , Neoplasias das Tubas Uterinas/diagnóstico , Oncologia , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/diagnóstico , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Procedimentos Cirúrgicos de Citorredução , Feminino , Humanos , Japão , Linfonodos/patologia , Metástase Linfática/diagnóstico por imagem , Metástase Linfática/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Ovarianas/patologia , Neoplasias Ovarianas/cirurgia , Neoplasias Peritoneais/patologia , Neoplasias Peritoneais/cirurgia , Reprodutibilidade dos Testes
2.
Int J Urol ; 20(10): 993-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23360237

RESUMO

OBJECTIVE: Recent studies have shown an improvement in prostate cancer diagnosis with the use of 3.0-Tesla magnetic resonance imaging. We retrospectively assessed the ability of this imaging technique to predict side-specific extracapsular extension of prostate cancer. METHODS: From October 2007 to August 2011, prostatectomy was carried out in 396 patients after preoperative 3.0-Tesla magnetic resonance imaging. Among these, 132 (primary sample) and 134 patients (validation sample) underwent 12-core prostate biopsy at the National Cancer Center Hospital of Tokyo, Japan, and at other institutions, respectively. In the primary dataset, univariate and multivariate analyses were carried out to predict side-specific extracapsular extension using variables determined preoperatively, including 3.0-Tesla magnetic resonance imaging findings (T2-weighted and diffusion-weighted imaging). A prediction model was then constructed and applied to the validation study sample. RESULTS: Multivariate analysis identified four significant independent predictors (P < 0.05), including a biopsy Gleason score of ≥8, positive 3.0-Tesla diffusion-weighted magnetic resonance imaging findings, ≥2 positive biopsy cores on each side and a maximum percentage of positive cores ≥31% on each side. The negative predictive value was 93.9% in the combination model with these four predictors, meanwhile the positive predictive value was 33.8%. Good reproducibility of these four significant predictors and the combination model was observed in the validation study sample. CONCLUSIONS: The side-specific extracapsular extension prediction by the biopsy Gleason score and factors associated with tumor location, including a positive 3.0-Tesla diffusion-weighted magnetic resonance imaging finding, have a high negative predictive value, but a low positive predictive value.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Prostatectomia/métodos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Gradação de Tumores , Invasividade Neoplásica , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Próstata/inervação , Próstata/cirurgia , Estudos Retrospectivos
3.
Aviat Space Environ Med ; 82(11): 1030-6, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22097637

RESUMO

INTRODUCTION: Physiological responses to +Gz stress have been reported in several studies. However, no reports exist on differences in arterial pressure responses between increasing and decreasing G phases. We hypothesized that +Gz stress and/or an anti-G support might disturb the circulation system and cause potential brain hypoperfusion, even if the anti-G support protects against G-induced loss of consciousness. METHODS: Dependency of +Gz magnitude, hemodynamic changes, renal sympathetic nerve activity (RSNA), and aortic blood flow (AoBF) were estimated in anesthetized rats to analyze the effects of +Gz stress and/or an anti-G support on arterial pressure at a level of the brain (APLB). The rats were exposed to +Gz using a centrifuge for small animals while wearing an anti-G suit. RESULTS: APLB remained at the control level while the anti-G suit was inflated. However, a decrease in APLB was observed twice during increasing and decreasing G phases using the anti-G suit. Hypotension in the decreasing C phase at +5 Gz was significantly deeper than that in the increasing G phase (47.5 +/- 7.7 vs. 29.6 +/- 3.0 mmHg). RSNA responses to Gz loads were greater in the decreasing G than in the increasing G phase (129.7 +/- 8.6 vs. 147.3 +/- 10.4%). Both AoBF and calculated vascular resistance were suppressed more significantly in the decreasing G than in the increasing G phase (38.3 +/- 4.4 vs. 34.4 +/- 3.4 ml x min(-1), 1.44 +/- 0.22 vs. 1.09 +/- 0.14 mmHg x min(-1) x ml(-1)). DISCUSSION: We conclude that transient excessive decreasing G hypotension may occur during the decreasing G phase, which may be due to anti-G suit functioning.


Assuntos
Gravitação , Trajes Gravitacionais , Hipotensão/fisiopatologia , Estresse Fisiológico/fisiologia , Anestésicos Intravenosos/administração & dosagem , Animais , Centrifugação , Rim/inervação , Masculino , Ratos , Ratos Sprague-Dawley , Sistema Nervoso Simpático/fisiologia , Uretana/administração & dosagem
4.
Abdom Imaging ; 34(4): 419-23, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17713812

RESUMO

PURPOSE: To evaluate the feasibility of detecting and measuring gastro-esophageal reflux (GER) with esophageal MR fluoroscopy in patients suffering from heartburn. MATERIALS AND METHODS: Twenty patients with heartburn underwent esophageal MR fluoroscopy. The T1-FFE sequence was applied for MR imaging. We examined the frequency and the level of GER on MR images. Based on the MRI observations, patients were classified into four MRI grades (grade 1-4). Endoscopic findings were categorized into five grades (grade 0 to D). The overall MRI grade, Carlsson's questionnaire score, and endoscopic findings were compared. RESULTS: GER was observed with MR fluoroscopy in 19 of 20 patients. GER was observed only several times in three patients, and much more frequently in the remaining 16 patients. Elevated levels of GER reached the lower, middle-to-upper esophagus, and the hypopharynx. The observed MRI grades were grade 1 = 1 patient, grade 2 = 3 patients, grade 3 = 2 patients, and grade 4 = 13 patients. There was no statistical correlation between the questionnaire score and the MRI grade. Also, there was no correlation between the grade of endoscopic findings and MRI grade. Six patients demonstrated continuous reflux on MRI did not show mucosal injury at endoscopy. CONCLUSION: Esophageal MR fluoroscopy may be a useful diagnostic tool for GERD for its ability to show GER, even in patients with no mucosal injury, and for suggesting the cause of the reflux.


Assuntos
Refluxo Gastroesofágico/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Estudos de Viabilidade , Feminino , Refluxo Gastroesofágico/classificação , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
5.
Acta Otolaryngol ; 128(4): 393-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18368572

RESUMO

CONCLUSION: The use of fluorodeoxyglucose positron emission tomography (FDG-PET) with a visual language task provided objective information on the development and plasticity of cortical language networks. This approach could help individuals involved in the habilitation and education of prelingually deafened children to decide upon the appropriate mode of communication. OBJECTIVES: To investigate the cortical processing of the visual component of language and the effect of deafness upon this activity. SUBJECTS AND METHODS: Six prelingually deafened children participated in this study. The subjects were numbered 1-6 in the order of their spoken communication skills. In the time period between an intravenous injection of 370 MBq 18F-FDG and PET scanning of the brain, each subject was instructed to watch a video of the face of a speaking person. The cortical radioactivity of each deaf child was compared with that of a group of normal- hearing adults using a t test in a basic SPM2 model. RESULTS: The widest bilaterally activated cortical area was detected in subject 1, who was the worst user of spoken language. By contrast, there was no significant difference between subject 6, who was the best user of spoken language with a hearing aid, and the normal hearing group.


Assuntos
Encéfalo/metabolismo , Surdez/metabolismo , Fluordesoxiglucose F18 , Idioma , Tomografia por Emissão de Pósitrons/métodos , Percepção da Fala/fisiologia , Percepção Visual/fisiologia , Adolescente , Adulto , Encéfalo/diagnóstico por imagem , Criança , Pré-Escolar , Surdez/diagnóstico por imagem , Surdez/fisiopatologia , Feminino , Fluordesoxiglucose F18/administração & dosagem , Seguimentos , Humanos , Injeções Intravenosas , Masculino , Prognóstico , Compostos Radiofarmacêuticos/administração & dosagem , Testes de Discriminação da Fala , Teste do Limiar de Recepção da Fala , Fatores de Tempo
7.
Radiat Med ; 22(5): 296-302, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15553009

RESUMO

PURPOSE: We assessed the value of analyzing visualization of the ovarian vessels in relation to the features of ovarian masses using MR images. MATERIALS AND METHODS: 74 patients with 91 masses (61 benign lesions and 30 malignant lesions) were evaluated. Ovarian masses were classified using the following features: 1) benignancy, 2) characterization, and 3) maximum diameter. We assessed the relationship between visualization and the diameter of the ipsilateral ovarian vessels and the features of ovarian masses. In addition, we assessed the relationship between visualization and the diameter of ovarian vessels and pelvic venous plexus (PVP) dilatation. RESULTS: Regardless of tumor laterality, 82% of ovarian vessels were visualized (121/148 vessels) on MR images. There was a significant relationship between the average diameter of ovarian vessels and dilatation of PVP (p<0.001). In patients without dilatation, there was a stronger relationship between ovarian vessel average diameter and benignancy (p=0.007), and the character of ovarian mass (solid versus cystic; p<0.05, mixed versus cystic; p<0.01). CONCLUSION: We confirmed a strong relationship between the diameter of ovarian vessels and dilatation of PVP. If ovarian vessels are dilated in patients without dilatation of PVP, we could suggest the possibility of malignant ovarian tumor.


Assuntos
Imageamento por Ressonância Magnética , Cistos Ovarianos/diagnóstico , Neoplasias Ovarianas/diagnóstico , Ovário/irrigação sanguínea , Veias/patologia , Dilatação Patológica/diagnóstico , Feminino , Humanos , Pessoa de Meia-Idade , Pelve/irrigação sanguínea , Estudos Retrospectivos
8.
J Comput Assist Tomogr ; 31(2): 229-35, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17414759

RESUMO

OBJECTIVE: We attempt to clarify specific imaging findings useful for differential diagnosis between endometrioid cancer and clear cell cancer. METHODS: We examined magnetic resonance imaging features on 11 endometrioid cancer and 9 clear cell cancer patients. We compared them, focusing on the locularity, characteristic and growth pattern of solid components, and association with endometrial diseases. RESULTS: Endometrioid cancer had a predominantly multilocular appearance, but clear cell cancer showed almost equally multilocular and unilocular appearances. For the growth pattern, endometrioid cancer in 6 patients demonstrated a "centric pattern" and an "eccentric pattern" in 4, whereas clear cell cancer showed predominantly an eccentric pattern. An internal slit in the solid component was seen in 4 endometrioid cancer patients but not seen in any of the patients with clear cell cancer. CONCLUSIONS: The magnetic resonance imaging appearance of the internal slit in solid components and the presence of endometrial disease are key factors in differentiating endometrioid cancer from clear cell cancer, although lesion locularity and growth pattern are not specific in both.


Assuntos
Adenocarcinoma de Células Claras/diagnóstico , Carcinoma Endometrioide/diagnóstico , Neoplasias do Endométrio/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Diagnóstico Diferencial , Endométrio/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
J Comput Assist Tomogr ; 28(5): 697-703, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15480047

RESUMO

OBJECTIVE: The purpose of this study was to try to delineate the esophageal passage under dynamic conditions and to determine optimum settings for esophageal magnetic resonance (MR) imaging. METHODS: Ten healthy volunteers underwent MR fluoroscopy with two T1-weighted sequences: turbo field echo (TFE) and T1-weighted fast field echo (T1-FFE). These sequences were compared for signal-to-noise ratios (SNRs) and image quality. To determine the optimum slice thickness, an additional 10 healthy volunteers underwent MR fluoroscopy. Results obtained for slice thicknesses of 25, 35, 45, and 55 mm were compared for delineated length of the esophagus and image quality. RESULTS: The T1-FFE sequences provided higher SNRs and better image quality than the TFE sequences (T1-FFE: 89.4 +/- 28.0, TFE: 52.4 +/- 16.7; P < 0.001). Artifacts were less prominent and delineation of the esophageal wall was better on the T1-FFE images. The delineation of the esophageal wall was best with a 35-mm slice thickness, although delineated length was the longest with a 55-mm slice thickness. CONCLUSION: This study showed T1-FFE to be a more suitable sequence than TFE and that the 35-mm slice thickness was the optimum slice thickness for esophageal MR fluoroscopy.


Assuntos
Esôfago/anatomia & histologia , Esôfago/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Imagem Ecoplanar , Feminino , Fluoroscopia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Masculino , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA