Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Europace ; 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39150065

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt EGM signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. STUDY AIM: If application repetition and catheter-tissue contact impact on lesion formation during PFA. METHODS: A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact-force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 hours in the vegetal model and over 6 hours in the porcine model. RESULTS: Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 mm and 4.4 ± 1.3 mm, respectively (p =0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0±0.9 mm with no contact Vs. 5.4±1.4 mm with 30 g of force; p=.0001). CONCLUSION: PFA delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA ablation are more related to PFA biophysics than mere EGM attenuation.

2.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37477946

RESUMO

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Inteligência Artificial , Estudos de Viabilidade , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Algoritmos , Ablação por Cateter/métodos
3.
Pacing Clin Electrophysiol ; 46(8): 904-912, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37486858

RESUMO

Pseudo-pacemaker syndrome (PPMS) is a rare complication of first-degree atrio-ventricular (AV) block in which a very prolonged PR interval causes AV dyssynchrony and subsequent symptoms of hemodynamic instability in the absence of an implanted pacemaker. The aim of this manuscript was to describe a unique case of PPMS and to provide a comprehensive review of the topic to help clinicians in the diagnosis and management of this condition. Through systematic research on PubMed, Google Scholar, EBSCO, and Ovid MEDLINE and using the search strings "pseudo-pacemaker syndrome" and "symptomatic first-degree AV block," we identified 14 articles accounting for 17 cases of PPMS, including our case report. The most common age group for PPMS was middle-aged and young adults, with an average age of 47 years. Palpitations were the most common presenting symptom and four main etiologies of PPMS were identified, as follows: (1) Idiopathic PPMS with evidence of impaired conduction over the AV node (20% of cases), (2) PPMS associated with reversable inflammatory causes (13%) or (3) associated with iatrogenic surgical or interventional procedures leading to the permanent damage of the normal AV conduction system (20%), and, finally, (4) PPM related to dual AV nodal physiology (DAVNP) as a primary finding (27%) or occurring after fast or slow pathway ablation for treatment of AV nodal re-entrant tachycardia (AVNRT) (20%). Treatment should be patient-tailored and based on the specific etiology once identified. However, the treatment of PPMS due to DAVNP without AVNRT presentation is yet to be clarified.


Assuntos
Bloqueio Atrioventricular , Ablação por Cateter , Marca-Passo Artificial , Taquicardia por Reentrada no Nó Atrioventricular , Pessoa de Meia-Idade , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Nó Atrioventricular , Sistema de Condução Cardíaco , Complicações Pós-Operatórias/terapia , Ablação por Cateter/métodos , Eletrocardiografia
4.
Heart Fail Rev ; 27(1): 103-110, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-32556671

RESUMO

The remarkable scientific progress in the treatment of patients with heart failure (HF) and reduced ejection fraction (HFrEF) has more than halved the risk of sudden cardiac death (SCD) in this setting. However, SCD remains one of the major causes of death in this patient population. Beyond the acknowledged role of beta blockers and inhibitors of the renin-angiotensin-aldosterone system (RAAS), a new class of drugs, the angiotensin receptor neprilysin inhibitors (ARNI), proved to reduce the overall cardiovascular mortality and, more specifically, the risk of SCD in HFrEF patients. The mechanism by which ARNI may reduce the mortality connected with harmful ventricular arrhythmias is not utterly clear. A variety of direct and indirect mechanisms have been suggested, but a favorable left ventricular reverse remodeling seems to play a key role in this setting. Furthermore, the well-known protective effect of implantable cardioverter-defibrillator (ICD) has been debated in HFrEF patients with non-ischemic cardiomyopathy (NICM) arguing against the role of primary prevention ICD in this setting, particularly when ARNI therapy is considered. The purpose of this review was to provide insights into the SCD mechanisms involved in HFrEF patients together with the current role of electrical therapies and new drug agents in this setting. Graphical abstract.


Assuntos
Insuficiência Cardíaca , Aminobutiratos , Antagonistas de Receptores de Angiotensina/uso terapêutico , Arritmias Cardíacas/terapia , Compostos de Bifenilo , Insuficiência Cardíaca/terapia , Humanos , Receptores de Angiotensina , Volume Sistólico , Tetrazóis , Valsartana
5.
J Card Surg ; 36(10): 3540-3546, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34254361

RESUMO

BACKGROUND: Primary cardiac tumors (PCT) are rare lesions but have the potential to cause significant morbidity if not timely treated. We reviewed our single-center experience in the surgical treatment of PCT with a focus on the long-term outcome. METHODS: From 2001 to 2020, 57 consecutive patients underwent surgical resection of PCT at our Institution. Data including the demographic characteristics, tumor histology, surgical procedure, and postoperative outcomes were collected and analyzed. RESULTS: Mean age at presentation was 63.6 ± 11.2 years, and 33 (57.9%) of the patients were female. A total of 55 (96.5%) subjects were diagnosed with benign cardiac tumor, while the remaining had malignant tumors. The most common histopathological type was myxoma. All patients survived to hospital discharge. Main postoperative complications were: acute kidney injury (n = 3), sepsis (n = 3), and stroke (n = 2). Mean follow-up time was 9 ± 5.9 years. Long-term mortality was 22.8% (13/57). No tumor recurrence was observed among survivors. There was a significant relationship between mortality and pathological characteristics of the tumor, and myxomas had higher survival rates. CONCLUSION: Surgical treatment of PCT is a safe and highly effective strategy associated with excellent short-term outcomes. Long-term survival remains poor for primary malignant tumors of the heart.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Neoplasias Cardíacas , Mixoma , Idoso , Feminino , Neoplasias Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Mixoma/cirurgia , Recidiva Local de Neoplasia , Estudos Retrospectivos , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 31(10): 2632-2641, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32652775

RESUMO

INTRODUCTION: Data regarding catheter ablation (CA) of atrial tachycardias (ATs) occurring after mitral valve surgery (MVS) are scarce. The aim of this study was to assess the safety and efficacy of CA of ATs in this surgical population through a systematic review of the literature and meta-analysis. METHODS: A systematic search on PubMed/MEDLINE, EMBASE, and Web of Science was performed considering patients undergoing CA for ATs occurring after MVS. Periprocedural thromboembolic and hemorrhagic complications were assessed. The acute success and maintenance of sinus rhythm (SR) at a mid (<24 months) and long-term follow-up (FU) after CA were investigated along with the burden of arrhythmic recurrence at FU. RESULTS: Fourteen studies for a total of 227 patients were considered. Three-dimensional (3D) mapping systems were used in all studies. Only two major bleedings were recorded with a pooled estimate of periprocedural major complications of 0%. The acute success after CA was 95% with a clear improvement over time. Although maintenance of SR was 71% at a midterm FU, long-term efficacy was as low as 47% due to an increased burden of atrial fibrillation (AF) recurrence despite multiple procedures/patient. CONCLUSION: In this meta-analysis, CA of postsurgical ATs after MVS proved safe and effective but with still a significant burden of AF recurrence at more than 24 months of FU due to a progressive atrial substrate deterioration. The improvement of procedural success over time might suggest a learning curve in optimizing the use of 3D mapping systems.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
7.
BMC Med Educ ; 20(1): 332, 2020 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-32977781

RESUMO

BACKGROUND: The Coronavirus Disease 19 (COVID-19) pandemic brought significant disruption to in-hospital medical training. Virtual reality simulating the clinical environment has the potential to overcome this issue and can be particularly useful to supplement the traditional in-hospital medical training during the COVID-19 pandemic, when hospital access is banned for medical students. The aim of this study was to assess medical students' perception on fully online training including simulated clinical scenarios during COVID-19 pandemic. METHODS: From May to July 2020 when in-hospital training was not possible, 122 students attending the sixth year of the course of Medicine and Surgery underwent online training sessions including an online platform with simulated clinical scenarios (Body Interact™) of 21 patient-based cases. Each session focused on one case, lasted 2 h and was divided into three different parts: introduction, virtual patient-based training, and debriefing. In the same period, adjunctive online training with formal presentation and discussion of clinical cases was also given. At the completion of training, a survey was performed, and students filled in a 12-item anonymous questionnaire on a voluntary basis to rate the training quality. Results were reported as percentages or with numeric ratings from 1 to 4. Due to the study design, no sample size was calculated. RESULTS: One hundred and fifteen students (94%) completed the questionnaire: 104 (90%) gave positive evaluation to virtual reality training and 107 (93%) appreciated the format in which online training was structured. The majority of participants considered the platform of virtual reality training realistic for the initial clinical assessment (77%), diagnostic activity (94%), and treatment options (81%). Furthermore, 97 (84%) considered the future use of this virtual reality training useful in addition to the apprenticeship at patient's bedside. Finally, 32 (28%) participants found the online access difficult due to technical issues. CONCLUSIONS: During the COVID-19 pandemic, online medical training including simulated clinical scenarios avoided training interruption and the majority of participant students gave a positive response on the perceived quality of this training modality. During this time frame, a non-negligible proportion of students experienced difficulties in online access to this virtual reality platform.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Educação a Distância/organização & administração , Educação de Graduação em Medicina/organização & administração , Pneumonia Viral/epidemiologia , Treinamento por Simulação/organização & administração , Realidade Virtual , COVID-19 , Competência Clínica , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Humanos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , SARS-CoV-2 , Inquéritos e Questionários
10.
Europace ; 20(2): 288-294, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28069836

RESUMO

Aims: During pulmonary vein isolation (PVI), even if operators are aware of the contact force (CF), its values may greatly vary and the impact of cardiac rhythm has not been thoroughly investigated yet. This study aims at assessing the actual values of CF, the applications with suboptimal CF, and the impact of cardiac rhythm on CF during PVI. Methods and results: Twenty patients undergoing point-by-point PVI with a CF-sensing catheter were considered. CF target was between 6 and 40 g. The mean CF per application (mCF) was evaluated and considered suboptimal if ≤5 g. The real-time graphic of CF was also evaluated and classified as pulsatile if regular variations synchronous with the atrial rate were seen; otherwise it was irregular. To achieve PVI, 1458 applications were delivered; 287 (19.68%) had suboptimal mCF. A great variability of mCF was seen according to anatomy, operators and patients. Compared to applications in atrial fibrillation (AF), those in sinus rhythm (SR) showed a higher median value of mCF (11 vs. 9 g; P = 0.0099) and a lower percentage of suboptimal mCF (17.95% vs. 25.15%; P = 0.0051). Compared to the irregular, the pulsatile pattern, almost exclusively observed in SR, was associated with higher mCF (14.69 ± 8.77 vs. 10.79 ± 7.89 g; P < 0.0001) and fewer suboptimal applications (8.02% vs. 27.73%; P < 0.0001). Conclusion: During PVI, several factors influence CF, which, despite optimization attempts, can be suboptimal in ∼20% of the applications. However, CF is higher in SR than in AF and this is strictly associated with a pulsatile pattern of instant CF values.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Frequência Cardíaca , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
11.
Europace ; 17(6): 946-52, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25600768

RESUMO

AIMS: In patients with asymptomatic ventricular pre-excitation (VPE) persistent at exercise stress test, this study evaluates the proportion of cases with adverse conduction properties of the atrioventricular accessory pathway (AP) at invasive electrophysiological study and the long-term follow-up after they received treatment according to pre-determined criteria. METHODS AND RESULTS: Over 10 years, asymptomatic patients with VPE persistent at exercise stress test referred for invasive electrophysiological evaluation including isoproterenol (IPN) infusion were included. Ablation was planned if they had at least one of the following criteria: (i) shortest pre-excited R-R interval (SPERRI) ≤250 ms and/or (ii) inducible atrioventricular re-entrant tachycardia (AVRT). Cryoablation was electively used in para-hisian and mid-septal APs. Patients non-eligible for ablation received no therapy. Sixty-three patients (45 males; mean age 26 ± 14 years) underwent electrophysiological evaluation: 7 had fasciculo-ventricular fibres and were excluded, whereas 56 had 58 APs. Thirty-one patients (55%) were eligible and underwent successful ablation: 87% had at least the SPERRI ≤ 250 ms and 61% had at least inducible AVRT. In 15 cases (48%) the ablation criteria were met only during IPN infusion. During follow-up (73 ± 33 months), one patient was successfully retreated for resumption of VPE in the ablation group, whereas no event was observed in the group of patients who received no treatment. CONCLUSION: In this subset of patients with asymptomatic VPE, invasive electrophysiological evaluation shows fast antegrade conduction over the AP and/or inducible AVRT in about half of the cases. Patients who received no therapy because of a benign electrophysiological profile had an event-free follow-up.


Assuntos
Feixe Acessório Atrioventricular/diagnóstico , Doenças Assintomáticas , Síndromes de Pré-Excitação/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Feixe Acessório Atrioventricular/complicações , Feixe Acessório Atrioventricular/cirurgia , Adolescente , Agonistas Adrenérgicos beta , Adulto , Ablação por Cateter/métodos , Criança , Estudos de Coortes , Técnicas Eletrofisiológicas Cardíacas/métodos , Teste de Esforço , Feminino , Humanos , Isoproterenol , Masculino , Pessoa de Meia-Idade , Síndromes de Pré-Excitação/complicações , Síndromes de Pré-Excitação/cirurgia , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Resultado do Tratamento , Adulto Jovem
12.
Int J Cardiol ; 395: 131394, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37748523

RESUMO

BACKGROUND: Myocardial injury is associated with adverse outcomes. No data are reported about sex differences in incidence and factors associated with myocardial injury in an emergency department (ED) setting from a real-world perspective. We aimed to assess whether sex plays a major role in the diagnosis of myocardial injury in the ED. METHODS: In this subanalysis of a retrospective study, patients presenting at the ED with at least one high-sensitivity cardiac troponin T (hs-cTnT) value and without acute coronary syndromes diagnosis were compared. RESULTS: 31,383 patients were admitted to the ED, 4660 had one hs-cTnT value, and 3937 were enrolled: 1943 females (49.4%) and 1994 males (50.6%). The diagnosis of myocardial injury was higher among men (36.8% vs. 32.9%, p < 0.01). Male sex was independently associated with myocardial injury. An older age, an elevated NT-proB-type Natriuretic Peptide and a lower estimated glomerular filtrate rate were independently associated with myocardial injury in both sexes. CONCLUSIONS: In the ED, from a real-world perspective, myocardial injury occurred more frequently in males, and it was associated with older age and the presence of cardiac, lung, and kidney disease but not higher hs-cTnT values.


Assuntos
Síndrome Coronariana Aguda , Traumatismos Cardíacos , Humanos , Masculino , Feminino , Estudos Retrospectivos , Caracteres Sexuais , Biomarcadores , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Traumatismos Cardíacos/diagnóstico , Traumatismos Cardíacos/epidemiologia , Serviço Hospitalar de Emergência , Troponina T
13.
J Am Coll Cardiol ; 83(1): 82-108, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38171713

RESUMO

Electrophysiological and interventional procedures have been increasingly used to reduce morbidity and mortality in patients experiencing cardiovascular diseases. Although antithrombotic therapies are critical to reduce the risk of stroke or other thromboembolic events, they can nonetheless increase the bleeding hazard. This is even more true in an aging population undergoing cardiac procedures in which the combination of oral anticoagulants and antiplatelet therapies would further increase the hemorrhagic risk. Hence, the timing, dose, and combination of antithrombotic therapies should be carefully chosen in each case. However, the maze of society guidelines and consensus documents published so far have progressively led to a hazier scenario in this setting. Aim of this review is to provide-in a single document-a quick, evidenced-based practical summary of the antithrombotic approaches used in different cardiac electrophysiology and interventional procedures to guide the busy clinician and the cardiac proceduralist in their everyday practice.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Idoso , Fibrinolíticos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/tratamento farmacológico , Resultado do Tratamento
14.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38390748

RESUMO

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Assuntos
Ablação por Cateter , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ventrículos do Coração/cirurgia , Catéteres , Desenho de Equipamento
15.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1824-1835, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37648342

RESUMO

The overall survival in patients undergoing lung transplantation is poor. Although postsurgical atrial arrhythmias seem to play a major role in the morbidity and mortality of this population, data regarding the clinical and interventional management of this complication are still controversial. Through a review of the literature in the field, we observed that not only the surgical technique is clearly arrhythmogenic, but the new administration of peri-procedure beta-blockers and amiodarone for arrhythmia prevention and treatment, respectively, seems harmful in these postsurgical patients. However, low-dose beta-blockers administered after surgery seem feasible in arrhythmia prevention in specific patient subgroups, and, aside from amiodarone, alternative antiarrhythmic agents can be safely and effectively used to treat symptomatic patients on top of adequate rate control. Finally, as to complex atrial arrhythmias occurring late after lung transplant surgery, radiofrequency catheter ablation seems a feasible treatment option. In light of this evidence and considering the absence of clear recommendations in the field, we suggest a practical approach that may help the clinician in the management of this postsurgical complication. However, as most of these considerations are drawn from small-sized and retrospective studies, more evidence is needed in the future to clarify which medical and interventional strategies may best treat these postsurgical arrhythmias and thus potentially improve the outcome of these frail patients.


Assuntos
Amiodarona , Fibrilação Atrial , Transplante de Pulmão , Humanos , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Transplante de Pulmão/efeitos adversos , Antiarrítmicos/uso terapêutico
16.
Minerva Cardiol Angiol ; 71(3): 333-341, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36305777

RESUMO

BACKGROUND: Although cryoablation (CA) of septally located accessory pathways (APs) is an established treatment for Wolff-Parkinson-White Syndrome, its major limitation is the lack of data regarding long-term follow-up (FU). The present study sought to investigate long-term outcomes of a specific CA protocol targeting para-Hisian (P-H) and mid-septal (M-S) APs. METHODS: Twenty-six patients who previously underwent CA of PH or MS APs from 2004 to 2014, were prospectively considered to receive a FU during 2021. All subjects received an outpatient control visit, performing an exercise stress test and a 24-h ECG Holter monitoring. RESULTS: Acute success was achieved in 22 patients (85%). One case of recurrence was reported at short-term FU. Long-term FU, performed after a mean time of 150±37 months, did not show ventricular preexcitation recurrences, with a success rate of 81%, and without late adverse events. Symptoms reduction (12% vs. 96%, P<.001) and lower rates of antiarrhythmic drug use (12% vs. 62%, P<.001) were observed at long term-FU with respect to baseline. This clinical outcome was detected also among patients who underwent unsuccessful CA at baseline. CONCLUSIONS: Our CA protocol confirmed remarkable safety and efficacy throughout a long-term FU. Significant clinical improvement in terms of antiarrhythmic therapy discontinuation and symptoms reduction was also shown among patients who experienced acute failure of CA.


Assuntos
Feixe Acessório Atrioventricular , Criocirurgia , Síndrome de Wolff-Parkinson-White , Humanos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Feixe Acessório Atrioventricular/cirurgia , Feixe Acessório Atrioventricular/etiologia , Síndrome de Wolff-Parkinson-White/cirurgia , Síndrome de Wolff-Parkinson-White/etiologia , Antiarrítmicos
17.
J Interv Card Electrophysiol ; 66(6): 1383-1389, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36456653

RESUMO

INTRODUCTION: Complex atrial tachyarrhythmias (CATs) are commonly observed in patients with prior catheter ablation or cardiac surgery. These arrhythmias are challenging to map and ablate. Historically, entrainment mapping was utilized to characterize CAT. With the advent of high-definition mapping (HDM), full visualization of the CAT circuit is possible which may obviate the need for entrainment mapping. METHODS: We sought to investigate the outcomes of catheter ablation of CAT guided only by HDM. Consecutive patients who underwent CAT ablation from 2017 to 2021 were included in our study (excluding right atrial tachyarrhythmias). Patients were sorted by the type of mapping performed. Group I consisted of patients where HDM alone was utilized with no attempt of entrainment. Group II consisted of patients where both entrainment and HDM were utilized. RESULTS: A total of 67 patients were included in our study, with 40 patients in HDM group (I) and 27 patients in entrainment group (II). No statistically significant difference regarding 1-year freedom from atrial arrhythmias was found between the two groups (80% vs 77.8%, p = 0.819). Four CATs were terminated by entrainment during procedure versus none in the HDM-only group (p = 0.011). CONCLUSIONS: CAT ablation with HDM alone yielded similar 1-year freedom from atrial arrhythmias compared to ablation with HDM and entrainment. Entrainment combined with HDM was associated with higher undesired CAT interruption rate. Further validation is needed with randomized control trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Taquicardia/cirurgia , Átrios do Coração/cirurgia , Ablação por Cateter/métodos
18.
Circ Arrhythm Electrophysiol ; 16(12): 663-671, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37994554

RESUMO

BACKGROUND: Pulsed field ablation (PFA) has emerged as an alternative to radiofrequency ablation. However, data on focal point-by-point PFA are scarce. The aim of this study was to compare lesion durability and collateral damage between focally delivered unipolar/biphasic PFA versus radiofrequency in swine. METHODS: Eighteen swine were randomized to low-dose PFA, high-dose PFA, and radiofrequency using a multimodality generator. Radiofrequency delivered by market-available generator served as control group. A contact force-sensing catheter was used to focally deliver PFA/radiofrequency at the pulmonary veins and other predefined sites in the atria. Animals were remapped postprocedurally and 28 days postablation to test lesion durability followed by gross necroscopy and histology. RESULTS: All targeted sites were successfully ablated (contact force value, 13.9±4.1 g). Follow-up remapping showed persistent pulmonary vein isolation in all animals (100%) with lesion durability at nonpulmonary vein sites proven in most (98%). Regardless of the energy source used, the lesion size was similar across the study groups. Transmurality was achieved in 95% of targeted sites and 100% at pulmonary veins. On histology, PFA animals showed more mature scar formation than their radiofrequency counterpart without myocardial necrosis or inflammation. Finally, no sign of collateral damage was observed in any of the groups. CONCLUSIONS: In a randomized preclinical study, focally delivered unipolar/biphasic PFA guided by contact force values was associated with durable lesions on chronic remapping and with mature scar formation on histology without signs of collateral injury on necroscopy. Further studies are needed to investigate the long-term feasibility of this new approach to atrial fibrillation treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Animais , Catéteres , Cicatriz , Suínos , Resultado do Tratamento
19.
J Clin Med ; 11(12)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35743394

RESUMO

Atypical atrial flutters (AAFL) are difficult-to-manage atrial arrhythmias, yet potentially amenable to effective radiofrequency catheter ablation (CA). However, data on CA feasibility are only sparingly reported in the literature in different clinical settings, such as AAFL related to surgical correction of congenital heart disease. The aim of this review was to provide an overview of the clinical settings in which AAFL may occur to help the cardiac electrophysiologist in the prediction of the tachycardia circuit location before CA. Moreover, the role and proper implementation of cutting-edge technologies in this setting were investigated as well as which procedural and clinical factors are associated with long-term failure to maintain sinus rhythm (SR) to find out which patients may, or may not, benefit from this procedure. Not only different surgical and non-surgical scenarios are associated with peculiar anatomical location of AAFL, but we also found that CA of AAFL is generally feasible. The success rate may be as low as 50% in surgically corrected congenital heart disease (CHD) patients but up to about 90% on average after pulmonary vein isolation (PVI) or in patients without structural heart disease. Over the years, the progressive implementation of three-dimensional mapping systems and high-density mapping tools has also proved helpful for ablation of these macro-reentrant circuits. However, the long-term maintenance of SR may still be suboptimal due to the progressive electroanatomic atrial remodeling occurring after cardiac surgery or other interventional procedures, thus limiting the likelihood of successful ablation in specific clinical settings.

20.
J Cardiovasc Dev Dis ; 9(4)2022 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-35448086

RESUMO

Because of demographic aging, the prevalence of arterial hypertension (HTN) and cardiac arrhythmias, namely atrial fibrillation (AF), is progressively increasing. Not only are these clinical entities strongly connected, but, acting with a synergistic effect, their association may cause a worse clinical outcome in patients already at risk of ischemic and/or haemorrhagic stroke and, consequently, disability and death. Despite the well-known association between HTN and AF, several pathogenetic mechanisms underlying the higher risk of AF in hypertensive patients are still incompletely known. Although several trials reported the overall clinical benefit of renin-angiotensin-aldosterone inhibitors in reducing incident AF in HTN, the role of this class of drugs is greatly reduced when AF diagnosis is already established, thus hinting at the urgent need for primary prevention measures to reduce AF occurrence in these patients. Through a thorough review of the available literature in the field, we investigated the basic mechanisms through which HTN is believed to promote AF, summarising the evidence supporting a pathophysiology-driven approach to prevent this arrhythmia in hypertensive patients, including those suffering from primary aldosteronism, a non-negligible and under-recognised cause of secondary HTN. Finally, in the hazy scenario of AF screening in hypertensive patients, we reviewed which patients should be screened, by which modality, and who should be offered oral anticoagulation for stroke prevention.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA