Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Int J Hyperthermia ; 31(6): 649-65, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26156212

RESUMO

PURPOSE: Size and geometry of the ablation zone obtained by currently available radiofrequency (RF) electrodes is highly variable. Reliability might be improved by matrix radiofrequency ablation (MRFA), in which the whole tumour volume is contained within a cage of x × y parallel electrodes. The aim of this study was to optimise the smallest building block for matrix radiofrequency ablation: a recently developed bipolar 2 × 2 electrode system. MATERIALS AND METHODS: In ex vivo bovine liver, the parameters of the experimental set-up were changed one by one. In a second step, a finite element method (FEM) modelling of the experiment was performed to better understand the experimental findings. RESULTS: The optimal power to obtain complete ablation in the shortest time was 50-60 W. Performing an ablation until impedance rise was superior to ablation for a fixed duration. Increasing electrode diameter improved completeness of ablation due to lower temperature along the electrodes. A chessboard pattern of electrode polarity was inferior to a row pattern due to an electric field void in between the electrodes. Variability of ablation size was limited. The FEM correctly simulated and explained the findings in ex vivo liver. CONCLUSIONS: These experiments and FEM modelling allowed a better insight in the factors influencing the ablation zone in a bipolar 2 × 2 electrode RF system. With optimal parameters, complete ablation was obtained quickly and with limited variability. This knowledge will be useful to build a larger system with x × y electrodes for MRFA.


Assuntos
Ablação por Cateter , Fígado/cirurgia , Modelos Biológicos , Animais , Ablação por Cateter/instrumentação , Bovinos , Eletrodos , Análise de Elementos Finitos
2.
BMC Public Health ; 14: 759, 2014 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-25070656

RESUMO

BACKGROUND: Breast cancer incidence in African population is low compared to western countries but the mortality rate is higher and the disease presents at a younger age and at a more advanced stage. The World Health Organisation and the Breast Health Global Initiative concluded that in low and middle income countries early breast cancer detection can be achieved by informing women on symptoms of breast cancer, on the practice of breast self-examination and clinical breast examination by trained health care workers. Based on these recommendations, we set up a breast cancer awareness campaign in Kinshasa, Democratic Republic of Congo (DRC). This paper describes the strategy that was established and the results that were achieved. METHODS: A breast cancer awareness campaign was started in 2010 and data were collected until the end of 2012. Clinicians (expert group) trained nurses and health care workers (awareness groups) on clinical, technical and social aspects of breast cancer. Different channels were used to inform women about the campaign and clinical data (on medical and family history) were collected. The participating women were investigated with clinical breast examination by the awareness group. Women in whom a palpable mass was detected were referred to the hospital: they received a mammography and ultrasound and--in case of suspicious findings--additionally a core needle biopsy. In case of a positive family history, a blood sample was taken for genetic investigation. RESULTS: In total, 4,315 women participated, resulting in 1,113 radiological breast examinations, performed in the General Hospital of Kinshasa of which 101 turned out to be malignant lesions. Fifty six percent of the women with breast cancer were less than 50 years old and 75% (65/87) were stage III tumors. A BRCA gene mutation was identified in a family with a severe history of breast cancer. CONCLUSIONS: Even without financial support, it was possible to start an awareness campaign for breast cancer in Kinshasa. This campaign increased the awareness on cancer of the women in Kinshasa. The results demonstrate that this campaign had an immediate impact on patients and their families.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Genes BRCA1 , Genes BRCA2 , Programas de Rastreamento/métodos , Mutação/genética , Adulto , Autoexame de Mama/métodos , Autoexame de Mama/estatística & dados numéricos , Congo , República Democrática do Congo/epidemiologia , Feminino , Predisposição Genética para Doença/epidemiologia , Humanos , Incidência , Mamografia/métodos , Mamografia/estatística & dados numéricos , Programas de Rastreamento/estatística & dados numéricos , Pessoa de Meia-Idade
3.
Anticancer Drugs ; 23(1): 12-21, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21857503

RESUMO

We sought to compare the therapeutic efficacy between two vascular-disrupting agents, combretastatin A4 phosphate (CA4P) and ZD6126, at a clinically relevant dose on tumor models with magnetic resonance imaging (MRI). Thirty rats with liver rhabdomyosarcoma were randomized into CA4P (10 mg/kg), ZD6126 (10 mg/kg), and control group (n=10 for each group). Multiparametric MRI biomarkers including tumor volume, enhancement ratio, necrosis ratio, apparent diffusion coefficient (ADC), and K (volume transfer constant) derived from T2-weighted, T1-weighted, contrast-enhanced T1-weighted, and diffusion-weighted imaging, and dynamic contrast-enhanced MRI were compared at pretreatment, 1 h, 6 h, 24 h, 48 h, and 120 h posttreatment; they were validated using ex-vivo techniques. Relative to rapidly growing tumors without necrosis in control rats, tumors grew slower in the CA4P group compared with the ZD6126 group with a higher necrosis ratio at 120 h (P<0.05), as proven by histopathology. In the CA4P group, K decreased from 1 h until 6 h, and partially recovered at 120 h. In the ZD6126 group, the reduced K at 1 h began to rebound from 6 h and exceeded the baseline value at 120 h (P<0.05), parallel to evolving enhancement ratios (P<0.05). ADC revealed more necrotic tumors with CA4P versus ZD6126 at 120 h (P<0.05). The different tumor responses were confirmed by ex-vivo microangiography and histopathology. CA4P was more effective than ZD6126 in impairing blood supply, inducing necrosis, and delaying growth in rat liver tumors at a clinically relevant dose. A single dose of vascular-disrupting agent was insufficient to destroy the tumor. The multiparametric MRI biomarkers enabled in-vivo noninvasive comparison of therapeutic efficacy between CA4P and ZD6126.


Assuntos
Neoplasias Hepáticas Experimentais/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Compostos Organofosforados/farmacologia , Rabdomiossarcoma/tratamento farmacológico , Estilbenos/farmacologia , Animais , Antineoplásicos Fitogênicos/administração & dosagem , Antineoplásicos Fitogênicos/farmacologia , Antineoplásicos Fitogênicos/uso terapêutico , Biomarcadores Tumorais/análise , Meios de Contraste , Ensaios de Seleção de Medicamentos Antitumorais , Injeções Intravenosas , Neoplasias Hepáticas Experimentais/patologia , Masculino , Microvasos/efeitos dos fármacos , Necrose , Compostos Organofosforados/administração & dosagem , Compostos Organofosforados/uso terapêutico , Ratos , Ratos Endogâmicos , Rabdomiossarcoma/patologia , Estilbenos/administração & dosagem , Estilbenos/uso terapêutico , Carga Tumoral/efeitos dos fármacos
4.
Int J Hyperthermia ; 28(7): 686-97, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22946490

RESUMO

PURPOSE: The aim of this study was to develop an electrode system with simple needle electrodes which would allow a reliable and predictable ablation zone with radiofrequency ablation (RFA). MATERIALS AND METHODS: In the first step, four parallel electrodes (active length 3 cm, diameter 1.8 mm) were inserted in ex vivo bovine liver. A power of 50 W was applied between two pairs of electrodes for 10 min or until current shut-off due to impedance rise. In the second step, the influence of changing inter-electrode distance on coagulation size and geometry was measured. In the third step, a finite element method (FEM) analysis of the experiment was performed to better understand the experimental findings. RESULTS: A bipolar four-electrode system with templates adjusting the inter-electrode distance was successfully developed for ex vivo experiments. A complete and reliable coagulation zone of a 3 × 2 × 2-cm block was obtained most efficiently with an inter-electrode distance of 2 cm in 5.12 ± 0.71 min. Above 2 cm, coagulation was incomplete due to a too low electric field, as demonstrated by the FEM analysis. CONCLUSIONS: The optimal inter-electrode distance of the present bipolar four-electrode system was 2 cm, allowing a reliable and predictable ablation zone in ex vivo liver. The FEM analysis correctly simulated and explained the findings in ex vivo liver. The experimental set-up may serve as a platform to gain more insight and to optimise the application of RFA by means of four or more simple needle electrodes.


Assuntos
Eletrocoagulação/instrumentação , Animais , Bovinos , Eletrocoagulação/métodos , Eletrodos , Análise de Elementos Finitos , Fígado/cirurgia
5.
Radiology ; 260(3): 799-807, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21712473

RESUMO

PURPOSE: To test the hypothesis that targeting the microenvironment (soil) may effectively kill cancer cells (seeds) through a small-molecular weight sequential dual-targeting theragnostic strategy, or dual-targeting approach. MATERIALS AND METHODS: With approval from the institutional animal care and use committee, 24 rats were implanted with 48 liver rhabdomyosarcomas (R1). First, the vascular-disrupting agent combretastatin A4 phosphate (CA4P) was injected at a dose of 10 mg/kg to cause tumor necrosis, which became a secondary target. Then, the necrosis-avid agent hypericin was radiolabeled with iodine 131 to form (131)I-hypericin, which was injected at 300 MBq/kg 24 hours after injection of CA4P. Both molecules have small molecular weight, are naturally or synthetically derivable, are intravenously injectable, and are of unique targetablities. The tumor response in the dual-targeting group was compared with that in vehicle-control and single-targeting (CA4P or (131)I-hypericin) groups with in vivo magnetic resonance imaging and scintigrams and ex vivo gamma counting, autoradiography, and histologic analysis. Tumor volumes, tumor doubling time (TDT), and radiobiodistribution were analyzed with statistical software. P values below .05 were considered to indicate a significant difference. RESULTS: Eight days after treatment, the tumor volume of rhabdomyosarcoma in the vehicle-control group was double that in both single-targeting groups (P < .001) and was five times that in the dual-targeting group (P < .0001), without treatment-related animal death. The TDT was significantly longer in the dual-targeting group (P < .0001). Necrosis appeared as hot spots on scintigrams, corresponding to 3.13% of the injected dose of (131)I-hypericin per gram of tissue (interquartile range, 2.92%-3.97%) and a target-to-liver ratio of 20. The dose was estimated to be 100 times the cumulative dose of 50 Gy needed for radiotherapeutic response. Thus, accumulated (131)I-hypericin from CA4P-induced necrosis killed residual cancer cells with ionizing radiation and inhibited tumor regrowth. CONCLUSION: This dual-targeting approach may be a simple and workable solution for cancer treatment and deserves further exploitation.


Assuntos
Radioisótopos do Iodo , Perileno/análogos & derivados , Rabdomiossarcoma/diagnóstico por imagem , Rabdomiossarcoma/tratamento farmacológico , Animais , Antracenos , Perileno/uso terapêutico , Cintilografia , Compostos Radiofarmacêuticos , Ratos , Resultado do Tratamento
6.
Eur Radiol ; 20(10): 2307-14, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20455065

RESUMO

OBJECTIVE: To evaluate if the screening performance parameters of digital mammography (DM) in a decentralized screening organization were comparable with film-screen mammography (FSM). METHODS: A nationwide screening program was launched in 2001, and since 2005 screening with DM has been allowed. Firstly, the parameters of the three regional screening units (RSUs) that first switched to DM (11,355 women) were compared with the FSM period of the same three RSUs (23,325 women). Secondly, they were compared with the results of the whole central breast unit (CBU). RESULTS: The recall rate (RR) of the DM group in the initial round was 2.64% [2.40% for FSM (p = 0.43)] and in the subsequent round 1.20% [1.58% for FSM (p = 0.03)]. The cancer detection rate (CDR) was 0.59% for DM and 0.64% for FSM (p = 0.56). The percentage of ductal carcinoma in situ was 0.07% for DM and 0.16% for FSM (p = 0.02). The positive predictive value was high in the subsequent rounds (DM 48.00%, FSM 45.93%) and lower in the initial round (DM 24.05%, FSM 24.86%). Compared with the results of the whole CBU, DM showed no significant difference. CONCLUSION: DM can be introduced in a decentralized screening organization with a high CDR without increasing the RR.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Mamografia/métodos , Idoso , Bélgica , Mama/patologia , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/patologia , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos
7.
Eur Radiol ; 20(8): 2013-26, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20182730

RESUMO

OBJECTIVES: To evaluate effects of a vascular-disrupting agent on rodent tumour models. METHODS: Twenty rats with liver rhabdomyosarcomas received ZD6126 intravenously at 20 mg/kg, and 10 vehicle-treated rats were used as controls. Multiple sequences, including diffusion-weighted imaging (DWI) and dynamic contrast-enhanced MRI (DCE-MRI) with the microvascular permeability constant (K), were acquired at baseline, 1 h, 24 h and 48 h post-treatment by using 1.5-T MRI. [(18)F]fluorodeoxyglucose micro-positron emission tomography ((18)F-FDG microPET) was acquired pre- and post-treatment. The imaging biomarkers including tumour volume, enhancement ratio, necrosis ratio, apparent diffusion coefficient (ADC) and K from MRI, and maximal standardised uptake value (SUV(max)) from FDG microPET were quantified and correlated with postmortem microangiography and histopathology. RESULTS: In the ZD6126-treated group, tumours grew slower with higher necrosis ratio at 48 h (P < 0.05), corresponding well to histopathology; tumour K decreased from 1 h until 24 h, and partially recovered at 48 h (P < 0.05), parallel to the evolving enhancement ratios (P < 0.05); ADCs varied with tumour viability and perfusion; and SUV(max) dropped at 24 h (P < 0.01). Relative K of tumour versus liver at 48 h correlated with relative vascular density on microangiography (r = 0.93, P < 0.05). CONCLUSIONS: The imaging biomarkers allowed morphological, functional and metabolic quantifications of vascular shutdown, necrosis formation and tumour relapse shortly after treatment. A single dose of ZD6126 significantly diminished tumour blood supply and growth until 48 h post-treatment.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Compostos Organofosforados/administração & dosagem , Inibidores da Angiogênese/administração & dosagem , Animais , Antineoplásicos/administração & dosagem , Biomarcadores/metabolismo , Injeções Intravenosas , Neoplasias Hepáticas/metabolismo , Masculino , Cintilografia , Compostos Radiofarmacêuticos , Ratos , Resultado do Tratamento
8.
Methods ; 48(2): 125-38, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19328231

RESUMO

Despite the widespread use of various imaging modalities in clinical and experimental oncology without or with combined application of commercially available nonspecific contrast agents (CAs), development of tissue- or organ- or disease-specific CAs has been a continuing effort for pursuing ever-improved sensitivity, specificity, and applicability. This is particularly true with magnetic resonance imaging (MRI) due to its intrinsic superb spatial/temporal/contrast resolutions and adequate detectability for tiny amount of substances. In this context, research using small animal tumor models has played an indispensible role in preclinical exploration of tissue specific CAs. Emphasizing more on methodological and practical aspects, this article aims to share our cumulated experiences on how to create tumor models for evaluation and development of new tissue specific MRI CAs and how to apply such models in imaging-based research studies. With the results that are repeatedly confirmed by later clinical applications in cancer patients, some of our early preclinical studies have contributed to the designs of subsequent clinical trials on the new CAs, some studies have predicted new utilities of these CAs; and other studies have led to the discoveries of new tissue- or disease-specific CAs with novel diagnostic or even therapeutic potentials. Among commonly adopted tumor models, the chemically induced and surgically implanted nodules in the liver prove very useful to simulate primary and metastatic intrahepatic tumors, respectively in clinical patients. The methods to create tumor models have eased procedures and yielded high success rates. The specific properties of the new CAs could be outshined by intraindividual comparison to the commercial CAs as nonspecific controls. Meticulous imaging-microangiography-histology matching techniques guaranteed colocalization of the lesion on in vivo MRI and postmortem tissue specimen, hence correct imaging interpretation and longstanding conclusions. As exemplified in the real study cases, the present experimental set-up proves applicable in small animals for imaging-based oncological investigations, and may provide a platform for the currently booming molecular imaging in a multimodality environment.


Assuntos
Meios de Contraste , Diagnóstico por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Técnicas de Diagnóstico Molecular/métodos , Neoplasias Experimentais , Animais , Biomarcadores Tumorais , Ensaios Clínicos como Assunto , Modelos Animais de Doenças , Ácido Edético/análogos & derivados , Humanos , Aumento da Imagem , Neoplasias Hepáticas/patologia , Modelos Animais , Transplante de Neoplasias , Fosfato de Piridoxal/análogos & derivados , Rabdomiossarcoma/patologia
9.
Surg Oncol ; 33: 145-157, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32561081

RESUMO

PURPOSE: Radiofrequency ablation (RFA) is increasingly being used to treat unresectable liver tumors. Complete ablation of the tumor and a safety margin is necessary to prevent local recurrence. With current electrodes, size and shape of the ablation zone are highly variable leading to unsatisfactory local recurrence rates, especially for tumors >3 cm. In order to improve predictability, we recently developed a system with four simple electrodes with complete ablation in between the electrodes. This rather small but reliable ablation zone is considered as a building block for matrix radiofrequency ablation (MRFA). In the current study we explored the influence of the electric mode (monopolar or bipolar) and the activation mode (consecutive, simultaneous or switching) on the size and geometry of the ablation zone. MATERIALS AND METHODS: The four electrode system was applied in ex vivo bovine liver. The electric and the activation mode were changed one by one, using constant power of 50 W in all experiments. Size and geometry of the ablation zone were measured. Finite element method (FEM) modelling of the experiment was performed. RESULTS: In ex vivo liver, a complete and predictable coagulation zone of a 3 × 2 × 2 cm block was obtained most efficiently in the bipolar simultaneous mode due to the combination of the higher heating efficacy of the bipolar mode and the lower impedance by the simultaneous activation of four electrodes, as supported by the FEM simulation. CONCLUSIONS: In ex vivo liver, the four electrode system used in a bipolar simultaneous mode offers the best perspectives as building block for MRFA. These results should be confirmed by in vivo experiments.


Assuntos
Eletrodos , Fígado/cirurgia , Ablação por Radiofrequência/métodos , Animais , Bovinos , Análise de Elementos Finitos , Fígado/patologia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Ablação por Radiofrequência/instrumentação
10.
Hum Brain Mapp ; 30(11): 3657-75, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19404990

RESUMO

Voxel-based analyses (VBA) are increasingly being used to detect white matter abnormalities with diffusion tensor imaging (DTI) in different types of pathologies. However, the validity, specificity, and sensitivity of statistical inferences of group differences to a large extent depend on the quality of the spatial normalization of the DTI images. Using high-dimensional nonrigid coregistration techniques that are able to align both the spatial and orientational diffusion information and incorporate appropriate templates that contain this complete DT information may improve this quality. Alternatively, a hybrid technique such as tract-based spatial statistics (TBSS) may improve the reliability of the statistical results by generating voxel-wise statistics without the need for perfect image alignment and spatial smoothing. In this study, we have used (1) a coregistration algorithm that was optimized for coregistration of DTI data and (2) a population-based DTI atlas to reanalyze our previously published VBA, which compared the fractional anisotropy and mean diffusivity maps of patients with amyotrophic lateral sclerosis (ALS) with those of healthy controls. Additionally, we performed a complementary TBSS analysis to improve our understanding and interpretation of the VBA results. We demonstrate that, as the overall variance of the diffusion properties is lowered after normalizing the DTI data with such recently developed techniques (VBA using our own optimized high-dimensional nonrigid coregistration and TBSS), more reliable voxel-wise statistical results can be obtained than had previously been possible, with our VBA and TBSS yielding very similar results. This study provides support for the view of ALS as a multisystem disease, in which the entire frontotemporal lobe is implicated.


Assuntos
Esclerose Lateral Amiotrófica/patologia , Mapeamento Encefálico , Encéfalo/fisiopatologia , Imagem de Tensor de Difusão/métodos , Adulto , Idoso , Algoritmos , Anisotropia , Encéfalo/patologia , Estudos de Casos e Controles , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
11.
Med Phys ; 36(3): 765-75, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19378737

RESUMO

Screening is the only proven approach to reduce the mortality of breast cancer, but significant numbers of breast cancers remain undetected even when all quality assurance guidelines are implemented. With the increasing adoption of digital mammography systems, image processing may be a key factor in the imaging chain. Although to our knowledge statistically significant effects of manufacturer-recommended image processings have not been previously demonstrated, the subjective experience of our radiologists, that the apparent image quality can vary considerably between different algorithms, motivated this study. This article addresses the impact of five such algorithms on the detection of clusters of microcalcifications. A database of unprocessed (raw) images of 200 normal digital mammograms, acquired with the Siemens Novation DR, was collected retrospectively. Realistic simulated microcalcification clusters were inserted in half of the unprocessed images. All unprocessed images were subsequently processed with five manufacturer-recommended image processing algorithms (Agfa Musica 1, IMS Raffaello Mammo 1.2, Sectra Mamea AB Sigmoid, Siemens OPVIEW v2, and Siemens OPVIEW v1). Four breast imaging radiologists were asked to locate and score the clusters in each image on a five point rating scale. The free-response data were analyzed by the jackknife free-response receiver operating characteristic (JAFROC) method and, for comparison, also with the receiver operating characteristic (ROC) method. JAFROC analysis revealed highly significant differences between the image processings (F = 8.51, p < 0.0001), suggesting that image processing strongly impacts the detectability of clusters. Siemens OPVIEW2 and Siemens OPVIEW1 yielded the highest and lowest performances, respectively. ROC analysis of the data also revealed significant differences between the processing but at lower significance (F = 3.47, p = 0.0305) than JAFROC. Both statistical analysis methods revealed that the same six pairs of modalities were significantly different, but the JAFROC confidence intervals were about 32% smaller than ROC confidence intervals. This study shows that image processing has a significant impact on the detection of microcalcifications in digital mammograms. Objective measurements, such as described here, should be used by the manufacturers to select the optimal image processing algorithm.


Assuntos
Algoritmos , Mamografia/estatística & dados numéricos , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Fenômenos Biofísicos , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Bases de Dados Factuais , Feminino , Humanos , Imagens de Fantasmas , Curva ROC , Software
12.
Ann Surg Oncol ; 15(1): 144-57, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17906898

RESUMO

BACKGROUND: Surgical resection is the gold standard in the treatment of resectable colorectal liver metastases (CRLM). In several centers, resection is being replaced by radiofrequency ablation (RFA), even though there is no evidence yet from randomized trials to support this. The aim of this study was to critically review the oncological evidence for and against the use of RFA for resectable CRLM. METHODS: An exhaustive review of RFA of colorectal metastases was carried out. RESULTS: Five-year survival data after RFA for resectable CRLM are not available. Percutaneous RFA is associated with worse local control, worse staging, and a small risk of electrode track seeding when compared with resection (level V evidence). For tumors

Assuntos
Ablação por Cateter , Neoplasias Colorretais/cirurgia , Hepatectomia , Neoplasias Hepáticas/cirurgia , Neoplasias Colorretais/patologia , Terapia Combinada , Humanos , Neoplasias Hepáticas/secundário , Estadiamento de Neoplasias , Prognóstico , Radiologia Intervencionista , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Taxa de Sobrevida , Resultado do Tratamento
13.
Med Phys ; 35(9): 4012-8, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18841852

RESUMO

The assessment of the performance of a digital mammography system requires an observer study with a relatively large number of cases with known truth which is often difficult to assemble. Several investigators have developed methods for generating hybrid abnormal images containing simulated microcalcifications. This article addresses some of the limitations of earlier methods. The new method is based on digital images of needle biopsy specimens. Since the specimens are imaged separately from the breast, the microcalcification attenuation profile scan is deduced without the effects of over and underlying tissues. The resulting templates are normalized for image acquisition specific parameters and reprocessed to simulate microcalcifications appropriate to other imaging systems, with different x-ray, detector and image processing parameters than the original acquisition system. This capability is not shared by previous simulation methods that have relied on extracting microcalcifications from breast images. The method was validated by five experienced mammographers who compared 59 pairs of simulated and real microcalcifications in a two-alternative forced choice task designed to test if they could distinguish the real from the simulated lesions. They also classified the shapes of the microcalcifications according to a standardized clinical lexicon. The observed probability of correct choice was 0.415, 95% confidence interval (0.284, 0.546), showing that the radiologists were unable to distinguish the lesions. The shape classification revealed substantial agreement with the truth (mean kappa = 0.70), showing that we were able to accurately simulate the lesion morphology. While currently limited to single microcalcifications, the method is extensible to more complex clusters of microcalcifications and to three-dimensional images. It can be used to objectively assess an imaging technology, especially with respect to its ability to adequately visualize the morphology of the lesions, which is a critical factor in the benign versus malignant classification of a lesion detected in screening mammography.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Simulação por Computador , Biópsia por Agulha Fina , Doenças Mamárias/patologia , Calcinose/patologia , Feminino , Humanos , Mamografia
14.
J Comput Assist Tomogr ; 32(4): 504-10, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18664833

RESUMO

OBJECTIVE: We evaluated an automated polyp size measurement tool in computed tomographic colonography for its accuracy and value for patient risk stratification. METHODS: A simulation program generated a raw data phantom with sessile and pedunculated polyps of known sizes using 120 to 140 kV and 50, 40, 20, 15, and 10 mAs. All polyps were measured by clicking on the polyp surface. Comparison of the calculated size with the known polyp sizes allowed calculation of reproducibility and accuracy. For patients with proven polyps, we also compared automated measurements with manual and endoscopic measurements to evaluate the effect on patient risk stratification. RESULTS: The automated measurement tool allowed accurate measurements. In the patient study, assignment to the correct size group was not significantly different from the radiologist's results. However, it slightly improved patient risk stratification by reducing both failed and unnecessary colonoscopy referral. CONCLUSIONS: An automated tool for polyp measurement in patients facilitates patient risk stratification.


Assuntos
Pólipos do Colo/diagnóstico , Colonografia Tomográfica Computadorizada/métodos , Software , Adulto , Idoso , Pólipos do Colo/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pacientes Ambulatoriais , Imagens de Fantasmas , Reprodutibilidade dos Testes , Medição de Risco/métodos , Índice de Gravidade de Doença , Validação de Programas de Computador
15.
Dig Surg ; 25(6): 445-60, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19212117

RESUMO

BACKGROUND: A recent proposal of a randomized trial comparing resection and radiofrequency ablation (RFA) in a selected subgroup of patients with small resectable colorectal liver metastases (CRLM) has initiated a debate on this issue. Meanwhile, new data have been published. The aim of the study was to update and critically review the oncological evidence in favor of and against the use of RFA for resectable CRLM in general and in favor of and against conducting a randomized trial in a selected subgroup of patients. METHODS: An exhaustive review was carried out of papers and abstracts on RFA of colorectal metastases published before July 15, 2008. RESULTS: Local recurrence rate after resection of CRLM is 1.2-10.4%. Local recurrence rate after RFA of CRLM is between 1.7 and 66.7%. For tumors <3 cm, local control after open RFA is equivalent to resection. Local recurrence rates, however, are higher for larger tumors and for the percutaneous and laparoscopic route. Accumulating evidence suggests that RFA and resection induce profoundly different biological effects, which may influence survival. CONCLUSIONS: Local recurrence rate after open RFA for CRLM <3 cm seems to be equivalent to resection. A randomized trial under strict conditions would be justified in this subgroup of patients. A randomized trial is currently not justified for larger tumors or for percutaneous or laparoscopic RFA, since local recurrence rates in these groups are too high to be acceptable for resectable tumors.


Assuntos
Ablação por Cateter/métodos , Neoplasias Colorretais/cirurgia , Hepatectomia/métodos , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia/mortalidade , Neoplasias Colorretais/mortalidade , Neoplasias Colorretais/patologia , Intervalo Livre de Doença , Feminino , Humanos , Neoplasias Hepáticas/mortalidade , Masculino , Avaliação das Necessidades , Invasividade Neoplásica/patologia , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Células Neoplásicas Circulantes , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
16.
Acta Neurochir Suppl ; 102: 259-62, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19388326

RESUMO

BACKGROUND: Several authors have found low absolute values of cerebral blood flow (CBF) in both contusion core and pericontusional parenchyma ofhead-injured patients by means of Xenon Computed Tomography (CT). Perfusion CT has become available as a new and validated tool for studying CBF in patients. The aim of the present study was to assess the relation between volume expansion of contusions and pericontusional CBF measured by perfusion CT. METHODS: Eight head-injured patients with a contusion on the admission CT head scan underwent a perfusion CT scan within 48 hours post trauma. The patients received standard head injury management. The eventual maximum contusion volume was assessed on the follow up plain CT scans. FINDINGS: Expansion of the contusion was observed in 6 patients. Reduced CBF was found in all contusions with absolute CBF values below 10 ml/100 g/min in the CT hyperdense/mixed density areas and below 20 ml/100 g/min in the surrounding hypodense areas. Penumbra areas, when defined by a mean transit time > 150% and cerebral blood volume > 2 ml/100 g, were limited to thin concentric rims surrounding the ischemic cores. We could not find a pattern of CBF that predicted contusion expansion. CONCLUSIONS: Based on the present preliminary data there is no indication that contusion expansion can be predicted on the basis of pericontusional CBF data.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Traumatismos Craniocerebrais/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fluxo Sanguíneo Regional/fisiologia , Estudos Retrospectivos
17.
Radiat Prot Dosimetry ; 129(1-3): 265-70, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18319279

RESUMO

In order to quantify the clinical quality of full-field digital mammography, a set of image quality parameters is developed. The set consisted of 12 image quality criteria and 8 physical characteristics of the image. The first set interrogates the visibility of anatomical structures and typical characteristics of a digital image, such as noise and saturation of dark and white areas. The second set of criteria evaluates contrast, sharpness and confidence with the representation of masses, microcalcifications and the image. The use of these criteria is reported in a retrospective study, in which the impact of dose on the radiological quality of digital mammograms is evaluated. Fifty patients acquired in a low-dose mode were retrieved and compared with 50 patients acquired in a dose mode that was set 41% higher. The dose affects, more than expected, contrast and sharpness of the image, whereas the visibility of the anatomical structures remains unchanged. With these parameters, quantification of the image quality is possible; however, because of subjectivity of the parameters, only intra-observer comparison and evaluation of the individual parameters rather than the overall results are advised. Together with physical tests of image quality, critical radiological evaluation of the quality should be included in the acceptance process of digital mammography.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Mamografia/normas , Garantia da Qualidade dos Cuidados de Saúde , Intensificação de Imagem Radiográfica/métodos , Intensificação de Imagem Radiográfica/normas , Doenças Mamárias/patologia , Feminino , Humanos , Mamografia/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/normas
18.
Med Phys ; 34(7): 2744-58, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17821982

RESUMO

This paper reports on a comparative study between the well-established test patterns for daily quality assurance (QA) of monitors of the American Association of Medical Physicists, Task Group 18 (AAPMtg18) and the Deutsches Institut für Normung e.V (DIN), and a newly proposed variable test pattern. A characteristic of the test patterns currently used for the QA of monitors is their static nature: The same test pattern is always used. This enables a learning effect that may bias the results over time. To address this problem we have developed a variable pattern for the quality assurance of monitors (MoniQA) that allows an evaluation of contrast visibility, geometric distortion, resolution, global image quality including uniformity, and artifacts. The test pattern includes randomly generated elements intended to prevent the observer from learning the test. Examples are random characters that have to be discriminated from the background to evaluate the threshold luminance difference and variable positions of different features in the test pattern. The newly proposed test patterns were generated and visualized on different viewing stations with a software tool developed in JAVA. In this study, we validated these patterns against the well-known AAPMtg18 and DIN test patterns on 22 monitors. The results showed that the MoniQA test can indicate the same monitor problems as the other well-known patterns and is significantly quicker to evaluate than the AAPMtg18 test patterns. The MoniQA pattern is a promising alternative for daily quality control of medical viewing stations.


Assuntos
Artefatos , Controle de Qualidade , Humanos , Software
19.
AJR Am J Roentgenol ; 188(3): 659-64, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17312051

RESUMO

OBJECTIVE: The purpose of this study was to retrospectively evaluate the safety, feasibility, and midterm clinical outcome of the use of three types of reduction stents inserted to manage transjugular intrahepatic portosystemic shunt (TIPS)-induced hepatic encephalopathy refractory to medical treatment. CONCLUSION: The use of a covered reduction stent-graft results in a greater increase in portosystemic gradient immediately after reduction than does use of a bare reduction stent. Relief of TIPS-induced hepatic encephalopathy tends to be greater in patients with reduction stent-grafts than in those with bare reduction stents.


Assuntos
Prótese Vascular , Encefalopatia Hepática/etiologia , Encefalopatia Hepática/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Retrospectivos , Resultado do Tratamento
20.
Acad Radiol ; 14(12): 1562-76, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18035285

RESUMO

RATIONALE AND OBJECTIVES: Computed tomography angiography (CTA) is an established tool for vascular imaging. However, high-intensity nonvascular structures in the contrast image can seriously hamper luminal visualization. This is an issue for three-dimensional visualization, where high-intensity structures might cover the underlying vasculature. But also in two dimensions, calcified plaques adjacent to the contrast-enhanced vessel lumen impede correct determination of the vessel boundary. High-intensity structures can be eliminated using subtraction CTA, where a native image is subtracted from the contrast image. However, patient and organ motion limits the widespread application of this technique. We propose to use nonrigid image registration to solve this problem. MATERIALS AND METHODS: For each patient, a native image and a contrast image are recorded, respectively, before and after contrast administration. The native image is registered to the contrast image using an automatic intensity-based nonrigid three-dimensional registration algorithm. Both images are merged in a fused image, allowing the user to switch between a view of the arteries, the bone or both. The procedure has been applied to 95 patients. RESULTS: In all cases, subtraction CTA using nonrigid registration allows for a significantly better artifacts removal than subtraction CTA without registration. Image quality of all images was judged adequate for clinical use. The average total processing time for each dataset is about 30 minutes. CONCLUSION: Nonrigid registration can allow for a great reduction in subtraction artifacts for subtraction CTA, resulting in a clear view of the vasculature.


Assuntos
Angiografia/métodos , Artérias Carótidas/diagnóstico por imagem , Cabeça/irrigação sanguínea , Processamento de Imagem Assistida por Computador/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Aterosclerose/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Meios de Contraste , Humanos , Imageamento Tridimensional/métodos , Crânio/irrigação sanguínea , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA