Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Arch Orthop Trauma Surg ; 142(10): 2489-2495, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33768276

RESUMO

INTRODUCTION: It remains unclear whether rheumatoid arthritis might be a cause of false positive of the histology for the diagnosis of prosthetic joint infection. Our aim was to evaluate the usefulness of the histology for the diagnosis of infection during hip and knee prosthesis revision in patients with rheumatoid arthritis. MATERIALS AND METHODS: All patients with the diagnosis of rheumatoid arthritis (RA) undergoing hip or knee revision surgery (total or partial) were retrospectively reviewed. Positive histology was considered when ≥ 5 neutrophils per high-power field (400×) were found in at least five separate microscopic fields. Patients who presented ≥ 2 positive cultures for the same microorganism or the presence of fistula were considered as "true positives". RESULTS: Thirty-two hip (n = 12) and knee (n = 20) revision procedures were performed. Sensitivity, specificity, positive and negative predictive value of the histology were 50%, 78.6%, 25% and 91.7%, respectively. Six out of the eight patients presenting with positive histology had negative cultures (75.0% of false positives). CONCLUSIONS: Our results suggest that, in the context of RA, negative histological results have a very high negative predictive value. RA poses false positive histology results for the diagnosis of infection during hip and knee revision when conventional cultures are used for diagnosis of infection.


Assuntos
Artrite Reumatoide , Artroplastia de Quadril , Prótese de Quadril , Prótese do Joelho , Infecções Relacionadas à Prótese , Artrite Reumatoide/complicações , Artrite Reumatoide/cirurgia , Humanos , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos
2.
Nanotechnology ; 30(13): 135701, 2019 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-30620928

RESUMO

Lead halide (APbX3) perovskites, in polycrystalline thin films but also perovskite nanoparticles (NPs) has demonstrated excellent performance to implement a new generation of photovoltaic and photonic devices. The structural characterization of APbX3 thin films using (scanning) transmission electron microscopy ((S)TEM) techniques can provide valuable information that can be used to understand and model their optoelectronic performance and device properties. However, since APbX3 perovskites are soft materials, their characterization using (S)TEM is challenging. Here, we study and compare the structural properties of two different metal halide APbX3 perovskite thin films: bulk CH3NH3PbI3 prepared by spin-coating of the precursors in solution and CsPbBr3 colloidal NPs synthetized and deposited by doctor blading. Both specimen preparation methods and working conditions for analysis by (S)TEM are properly optimized. We show that CH3NH3PbI3 thin films grown by a one-step method are composed of independent grains with random orientations. The growth method results in the formation of tetragonal perovskite thin films with good adherence to an underlying TiO2 layer, which is characterized by a photoluminescence (PL) emission band centered at 775 nm. The perovskite thin films based on CsPbBr3 colloidal NPs, which are used as the building blocks of the film, are preserved by the deposition process, even if small gaps are observed between adjacent NPs. The crystal structure of CsPbBr3 NPs is cubic, which is beneficial for optical properties due to its optimal band gap. The absorption and PL spectra measured in both the thin film and the colloidal solution of CsPbBr3 NPs are very similar, indicating a good homogeneity of the thin films and the absence of aggregation of NPs. However, a particular care was required to avoid long electron irradiation times during our structural studies, even at a low voltage of 80 kV, as the material was observed to decompose through Pb segregation.

3.
Nanotechnology ; 28(11): 115706, 2017 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-28117306

RESUMO

The particular optical and electronic properties recently reported for 2D InSe depict this 2D material as being very versatile for future electronic and optoelectronic devices with tunable and optimized functionalities. For its fundamental study and the development of practical applications, rapid and accurate identification methods of atomically thin InSe are essential. Here, we demonstrate an enhancement of the optical contrast between InSe nanosheets and the underlying SiO2/Si substrate by illuminating with a 40 nm wide bandpass filter centered at 500 nm. Moreover, we study the optical contrast of 2D InSe on transparent substrates. Our results suggest that a good optical contrast is achieved for transparent substrates with low real refractive indices such as LiF or a viscoelastic polydimethylsiloxane stamp. In this case, an optimum optical contrast would be achieved by using a bandpass filter centered at 450 nm. These results can be very useful for speeding up the continuously growing research on 2D InSe and its applications.

4.
Nanotechnology ; 26(47): 475201, 2015 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-26526708

RESUMO

In this work Au nanoparticles (AuNPs) are incorporated into poly(methyl methacrylate) (PMMA) waveguides to develop optical couplers that are compatible with planar organic polymer photonics. A method for growing AuNPs (of 10 to 100 nm in size) inside the commercially available Novolak resist is proposed with the intention of tuning the plasmon resonance and the absorption/scattering efficiencies inside the patterned structures. The refractive index of the MNP-Novolak nanocomposite (MNPs: noble metal nanoparticles) is carefully analysed both experimentally and numerically in order to find the appropriate fabrication conditions (filling factor and growth time) to optimize the scattering cross section at a desired wavelength. Then the nanocomposite is patterned inside a PMMA waveguide to exploit its scattering properties to couple and guide a normal incident laser light beam along the polymer. In this way, light coupling is experimentally demonstrated in a broad wavelength range (404-780 nm). Due to the elliptical shape of the MNPs the nanocomposite demonstrates a birefringence, which enhances the coupling to the TE mode up to efficiencies of around 1%.

5.
Arch Orthop Trauma Surg ; 135(10): 1445-51, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26298563

RESUMO

INTRODUCTION: Stiffness after a total knee arthroplasty (TKA) is one of the most common post-operative complications. The purpose of this study is the evaluation of the effectiveness of TT proximalization osteotomy of improving a lack of flexion and secondary pain in patella baja (infera) post-TKA. MATERIALS AND METHODS: Between April 2007 and July 2012, TT proximalization osteotomy was performed on 21 patients. The average preoperative flexion was 70° (in a range of 60-80). Clinical pre- and post-operative evaluations were performed with Knee Society Score, Western Ontario and McMaster Universities Arthritis Index scales and a satisfaction survey. Modified Blackburn-Peel index and Portner angle were used to evaluate patellar height. RESULTS: After an average follow-up of 35 months (range 18-48), an average flexion of 100° (range 90-100) and an overall satisfaction were obtained. Clinical scores improved significantly. The Blackburn-Peel index and Portner angle improved significantly from 0.3 (range 0.1-0.5) to 0.4 (0.3-0.5) and from 9 (3-15) to 12 (9-18), respectively. Three patients showed no signs of osteotomy consolidation. However, this was not linked to a lack of extension or an increase in local pain. CONCLUSION: TT proximalization osteotomy provides satisfactory results in improving a lack of flexion and pain in patella baja post-TKR.


Assuntos
Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Patela/cirurgia , Complicações Pós-Operatórias/cirurgia , Tíbia/cirurgia , Idoso , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Amplitude de Movimento Articular , Reoperação
6.
Opt Lett ; 39(16): 4962-5, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-25121919

RESUMO

In this Letter, we study a new kind of organic polymer waveguide numerically and experimentally by combining an ultrathin (10-50 nm) layer of compactly packed CdSe/ZnS core/shell colloidal quantum dots (QDs) sandwiched between two cladding poly(methyl methacrylate) (PMMA) layers. When a pumping laser beam is coupled into the waveguide edge, light is mostly confined around the QD layer, improving the efficiency of excitation. Moreover, the absence of losses in the claddings allows the propagation of the pumping laser beam along the entire waveguide length; hence, a high-intensity photoluminescence (PL) is produced. Furthermore, a novel fabrication technology is developed to pattern the PMMA into ridge structures by UV lithography in order to provide additional light confinement. The sandwich-type waveguide is analyzed in comparison to a similar one formed by a PMMA film homogeneously doped by the same QDs. A 100-fold enhancement in the waveguided PL is found for the sandwich-type case due to the higher concentration of QDs inside the waveguide.

7.
Nanotechnology ; 25(3): 035204, 2014 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-24356330

RESUMO

Photoluminescence and time resolved photoluminescence from single metamorphic InAs/GaAs quantum dots (QDs) emitting at 1.3 µm have been measured by means of a novel fibre-based characterization set-up. We demonstrate that the use of a wavelength tunable fibre Bragg grating filter increases the light collection efficiency by more than one order of magnitude as compared to a conventional grating monochromator. We identified single charged exciton and neutral biexciton transitions in the framework of a random population model. The QD recombination dynamics under pulsed excitation can be understood under the weak quantum confinement potential limit and the interaction between carriers at the wetting layer and QD states.

8.
Rev Esp Cir Ortop Traumatol ; 68(2): 97-107, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36934806

RESUMO

BACKGROUND AND OBJECTIVE: In orthopedic surgery, it is clear that an optimal standardized closure technique has not yet been developed. Locally, there are no objective data describing the standard surgical practice in wound closure. The aim of this study is to analyze the clinical practice of surgical wound closure in orthopedic surgery by means of a survey of a representative local sample and thus obtain information on the context of closure in Spain. METHOD: an ad hoc group of specialists in orthopedic surgery and traumatology was formed. The group of experts, after analyzing the literature, developed a questionnaire of 32 closed multiple-choice questions divided into the following blocks: hemostasis, surgical wound closure (deep, superficial, and cutaneous), and dressings. RESULTS: A total of 471 surgeons responded to the survey completely and with sufficient information to perform the descriptive analysis. 79% believe that ATX can influence the decrease in surgical site infection rate. 96% believe that the type of deep closure at the level of the arthrotomy could influence outcomes and complications after hip and/or knee replacements. 85% believe that the type of shallow closure at the subcutaneous level may influence outcomes and complications after hip and/or knee replacement. 64% of surgeons use single-use incisional negative pressure therapy for the treatment of surgical wound complications (seroma, prolonged drainage, dehiscence). CONCLUSIONS: There is a high level of variability in wound closure in our setting and a low level of training on the subject. The authors recommend that the different scientific societies invest resources to improve training in this field and reduce the percentage of surgeons who are considered inadequately trained, as well as adapting closure techniques to those considered gold standard according to the evidence.

9.
Rev Esp Cir Ortop Traumatol ; 68(2): T97-T107, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37992859

RESUMO

BACKGROUND AND OBJECTIVE: In orthopaedic surgery, it is clear that an optimal standardised closure technique has not yet been developed. Locally, there are no objective data describing the standard surgical practice in wound closure. The aim of this study is to analyse the clinical practice of surgical wound closure in orthopaedic surgery by means of a survey of a representative local sample and thus obtain information on the context of closure in Spain. MATERIAL AND METHOD: An ad hoc group of specialists in orthopaedic surgery and traumatology was formed. The group of experts, after analyzing the literature, developed a questionnaire of 32 closed multiple-choice questions divided into the following blocks: hemostasis, surgical wound closure (deep, superficial, and cutaneous), and dressings. RESULTS: A total of 471 surgeons responded to the survey completely and with sufficient information to perform the descriptive analysis. 79% believe that ATX can influence the decrease in surgical site infection rate. 96% believe that the type of deep closure at the level of the arthrotomy could influence outcomes and complications after hip and/or knee replacements. 85% believe that the type of shallow closure at the subcutaneous level may influence outcomes and complications after hip and/or knee replacement. 64% of surgeons use single-use incisional negative pressure therapy for the treatment of surgical wound complications (seroma, prolonged drainage, dehiscence). CONCLUSIONS: There is a high level of variability in wound closure in our setting and a low level of training on the subject. The authors recommend that the different scientific societies invest resources to improve training in this field and reduce the percentage of surgeons who are considered inadequately trained, as well as adapting closure techniques to those considered gold standard according to the evidence.

10.
Phys Rev Lett ; 110(12): 124301, 2013 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-25166808

RESUMO

This Letter presents the design, fabrication, and experimental characterization of a directional three-dimensional acoustic cloak for airborne sound. The cloak consists of 60 concentric acoustically rigid tori surrounding the cloaked object, a sphere of radius 4 cm. The major radii and positions of the tori along the symmetry axis are determined using the condition of complete cancellation of the acoustic field scattered from the sphere. They are obtained through an optimization technique that combines genetic algorithm and simulated annealing. The scattering cross section of the sphere with the cloak, which is the magnitude that is minimized, is calculated using the method of fundamental solutions. The low-loss fabricated cloak shows a reduction of the 90% of the sphere scattering cross section at the frequency of 8.55 kHz.

11.
Nanotechnology ; 24(6): 065202, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23339892

RESUMO

The anti-reflective effect of dielectric coatings used in silicon solar cells has traditionally been the subject of intensive studies and practical applications. In recent years the interest has permanently grown in plasmonic layers based on metal nanoparticles, which are shown to increase light trapping in the underlying silicon. In the present work we have combined these two concepts by means of in situ synthesis of Au nanoparticles in a dielectric matrix (TiO2), which is commonly used as an anti-reflective coating in silicon solar cells, and added the third element: a 10-20% porosity in the matrix. The porosity is formed by means of a controllable wet etching by low concentration HF. As a consequence, the experimentally measured reflectance of silicon coated by such a plasmonic layer decreases to practically zero in a broad wavelength region around the localized surface plasmon resonance. Furthermore, we demonstrate that extinction and reflectance spectra of silicon coated by the plasmonic films can be successfully accounted for by means of Fresnel formulae, in which a double refractive index of the metal-dielectric material is used. This double refractive index cannot be explained by effective medium theory (Maxwell-Garnett, for example) and appears when the contribution of Au nanoparticles located at the TiO2/Si interface is high enough to result in formation of interface surface plasmon modes.

12.
Rev Esp Cir Ortop Traumatol ; 67(4): 334-341, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36272500

RESUMO

Robotic surgery is a surgical technique that is on the rise. The goal of robotic-assisted total knee arthroplasty (RA-TKA) is to provide the surgeon with a tool to accurately execute bone cuts according to previous surgical planning to restore knee kinematics and balance of soft tissue, being able to precisely apply the type of alignment that we choose. In addition, RA-TKA is a very useful tool for training. Within the limitations, there is the learning curve, the need for specific equipment, the high cost of the devices, the increase in radiation in some systems and that each robot is linked to a specific type of implant. Current studies show, with RA-TKA, variations in the alignment of the mechanical axis are reduced, postoperative pain is improved and earlier discharge is facilitated. On the other hand, there are no differences in terms of range of motion, alignment, gap balance, complications, surgical time or functional results.

13.
Rev Esp Cir Ortop Traumatol ; 67(4): T334-T341, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36863515

RESUMO

Robotic surgery is a surgical technique that is on the rise. The goal of robotic-assisted total knee arthroplasty (RA-TKA) is to provide the surgeon with a tool to accurately execute bone cuts according to previous surgical planning to restore knee kinematics and balance of soft tissue, being able to precisely apply the type of alignment that we choose. In addition, RA-TKA is a very useful tool for training. Within the limitations, there is the learning curve, the need for specific equipment, the high cost of the devices, the increase in radiation in some systems and that each robot is linked to a specific type of implant. Current studies show, with RA-TKA, variations in the alignment of the mechanical axis are reduced, postoperative pain is improved and earlier discharge is facilitated. On the other hand, there are no differences in terms of range of motion, alignment, gap balance, complications, surgical time or functional results.

14.
Rev Esp Cir Ortop Traumatol ; 67(5): 426-445, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37116750

RESUMO

BACKGROUND: Prosthetic joint infection is one of the most serious complications in orthopedics. Prognostic systematic reviews (SR) detecting and assessing factors related to prosthetic joint infection, allow better prediction of risk and implementation of preventive measures. Although prognostic SR are increasingly frequent, their methodological field presents some knowledge gaps. PURPOSE: To carry out an overview of SR assessing risk factors for prosthetic joint infection, describing and synthesizing their evidence. Secondarily, to assess the risk of bias and methodological quality. MATERIAL AND METHODS: We conducted a bibliographic search in 4databases (May 2021) to identify prognostic SR evaluating any risk factor for prosthetic joint infection. We evaluated risk of bias with the ROBIS tool, and methodological quality with a modified AMSTAR-2 tool. We computed the overlap degree study between included SR. RESULTS: Twenty-three SR were included, studying 15 factors for prosthetic joint infection, of which, 13 had significant association. The most frequently studied risk factors were obesity, intra-articular corticosteroids, smoking and uncontrolled diabetes. Overlapping between SR was high for obesity and very high for intra-articular corticoid injection, smoking and uncontrolled diabetes. Risk of bias was considered low in 8SRs (34.7%). The modified AMSTAR-2 tool showed important methodological gaps. CONCLUSIONS: Identification of procedural-modifiable factors, such as intra-articular corticoids use, can give patients better results. Overlapping between SR was very high, meaning that some SR are redundant. The evidence on risk factors for prosthetic joint infection is weak due to high risk of bias and limited methodological quality.

15.
Rev Esp Cir Ortop Traumatol ; 67(5): T426-T445, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37364724

RESUMO

BACKGROUND: Prosthetic joint infection is one of the most serious complications in orthopedics. Prognostic systematic reviews (SRs) detecting and assessing factors related to prosthetic joint infection, allow better prediction of risk and implementation of preventive measures. Although prognostic SRs are increasingly frequent, their methodological field presents some knowledge gaps. PURPOSE: To carry out an overview of SR assessing risk factors for prosthetic joint infection, describing and synthesizing their evidence. Secondarily, to assess the risk of bias and methodological quality. MATERIAL AND METHODS: We conducted a bibliographic search in 4 databases (May 2021) to identify prognostic SR evaluating any risk factor for prosthetic joint infection. We evaluated risk of bias with the ROBIS tool, and methodological quality with a modified AMSTAR-2 tool. We computed the overlap degree study between included SR. RESULTS: Twenty-three SRs were included, studying 15 factors for prosthetic joint infection, of which, 13 had significant association. The most frequently studied risk factors were obesity, intra-articular corticosteroids, smoking and uncontrolled diabetes. Overlapping between SR was high for obesity and very high for intra-articular corticoid injection, smoking and uncontrolled diabetes. Risk of bias was considered low in 8 SRs (34.7%). The modified AMSTAR-2 tool showed important methodological gaps. CONCLUSIONS: Identification of procedural-modifiable factors, such as intra-articular corticoids use, can give patients better results. Overlapping between SR was very high, meaning that some SRs are redundant. The evidence on risk factors for prosthetic joint infection is weak due to high risk of bias and limited methodological quality.

16.
Artigo em Inglês | MEDLINE | ID: mdl-35869007

RESUMO

Total knee arthroplasty is one of the most frequently performed orthopaedic surgeries. However, up to 20% of patients develop persistent postoperative pain. Persistent postoperative pain may be an extension of acute postoperative pain, but can also occur after more than 3 months without symptoms. Risk factors associated with persistent postoperative pain after arthroplasty have now been characterised within the patient's perioperative context (preoperative, intraoperative and postoperative), and can be grouped under genetic, demographic, clinical, surgical, analgesic, inflammatory and psychological factors. Identification and prevention of persistent postoperative pain through a multimodal and biopsychosocial approach is essential in the context of perioperative medicine, and has been shown to prevent or ameliorate postoperative pain.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Medicina Perioperatória , Analgésicos/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Humanos , Prótese do Joelho/efeitos adversos , Dor Pós-Operatória/tratamento farmacológico
17.
Nanoscale ; 14(36): 13214-13226, 2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36047914

RESUMO

CsPbI3 perovskite nanocrystals (NCs) are promising building blocks for photovoltaics and optoelectronics. However, they exhibit an essential drawback in the form of phase stability: α-phase, with a ∼1.80 eV bandgap, can easily experience a phase transition to a non-radiative orthorhombic δ-phase in an ambient environment. This leads to the need to carry out the CsPbI3-based device fabrication in an inert atmosphere, which is technologically inconvenient and expensive. One of the most successful approaches proposed to overcome this problem is synthesizing mixed halide CsPbBr3-xIx NCs to improve the stability of the α-phase perovskite structure. However, the formation of high-quality thin films of CsPbBr3-xIx NCs with high PLQY is challenging owing to the degradation of their optical properties after deposition on a substrate. This work presents spray coating to carry out a solid-state anion exchange in CsPbBr3 NCs thin films at ambient conditions with low-demanding reaction conditions. This constitutes a novel open-air and annealing-free technology to manufacture CsPbBr3-xIx NC thin films with high optical quality and record high photoluminescence quantum yields (PLQY) based on spray-driven halide (Br- to I-) anion exchange in a solid-state phase. Besides, tunable emission wavelengths between 520 and 670 nm can be obtained from CsPbBr3-xIx NC films using accurate tuning volumes of HI solution sprayed over the initial surface of CsPbBr3 film to provide the halide exchange. The optical quality of the halide-exchanged PNCs films remains practically identical to that of initial Br-containing layers, with a remarkable PLQY enhancement after anion exchange, from ∼61% for CsPbBr3 thin films emitting at 520 nm to ∼84% for mixed halide CsPbBr3-xIx film emitting at 640 nm. The huge potential of the system is confirmed by demonstrating a low-threshold amplified spontaneous emission.

18.
Rev Esp Cir Ortop Traumatol ; 66(4): 306-314, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35477660

RESUMO

BACKGROUND AND OBJECTIVE: Prevention of postoperative surgical site infections is indeed feasible. The aim of this work is to analyses adherence to international guidelines for the prevention of infections in elective orthopedic prosthetic surgery by means of a survey of a representative sample of Spanish orthopedic surgeons, with the purpose to establish general recommendations. MATERIAL AND METHOD: A population survey was conducted in online format consisting of 78 questions to analyze the usual clinical practice of Spanish orthopedic surgeons in the face of periprosthetic infections of the hip and knee, and their adherence to international guidelines. RESULTS: The results of the survey (n=138) show in clinical practice of Spanish orthopedic surgeons a high adherence to most of the international recommendations. CONCLUSIONS: The integration high adherence of individual clinical practice with the best available scientific evidence based on the recommendations of international guidelines is the best way to adequately manage the prevention of periprosthetic infection in elective surgery.

19.
Nanotechnology ; 22(43): 435202, 2011 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-21955572

RESUMO

In this paper, active planar waveguides based on the incorporation of CdSe and CdTe nanocrystal quantum dots in a polymer matrix are demonstrated. In the case of doping the polymer with both types of quantum dots, the nanocomposite film guides both emitted colors, green (550 nm, CdTe) and orange (600 nm, CdSe). The optical pumping laser can be coupled not only with a standard end-fire coupling system, but also directing the beam to the surface of the sample, indicating a good absorption cross-section and waveguide properties. To achieve these results, a study of the nanocomposite optical properties as a function of the nanocrystal concentration is presented and the optimum conditions are found for waveguiding.

20.
Nanotechnology ; 22(6): 065703, 2011 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-21212489

RESUMO

We performed a detailed investigation of the structural and optical properties of multi-layers of InP/GaAs quantum dots, which present a type II interface arrangement. Transmission electronic microscopy analysis has revealed relatively large dots that coalesce forming so-called quantum posts when the GaAs layer between the InP layers is thin. We observed that the structural properties and morphology affect the resulting radiative lifetime of the carriers in our systems. The carrier lifetimes are relatively long, as expected for type II systems, as compared to those observed for single layer InP/GaAs quantum dots. The interface intermixing effect has been pointed out as a limiting factor for obtaining an effective spatial separation of electrons and holes in the case of single layer InP/GaAs quantum-dot samples. In the present case this effect seems to be less critical due to the particular carrier wavefunction distribution along the structures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA