Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Nat Commun ; 12(1): 7107, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876586

RESUMO

In contrast to the well-recognized permafrost carbon (C) feedback to climate change, the fate of permafrost nitrogen (N) after thaw is poorly understood. According to mounting evidence, part of the N liberated from permafrost may be released to the atmosphere as the strong greenhouse gas (GHG) nitrous oxide (N2O). Here, we report post-thaw N2O release from late Pleistocene permafrost deposits called Yedoma, which store a substantial part of permafrost C and N and are highly vulnerable to thaw. While freshly thawed, unvegetated Yedoma in disturbed areas emit little N2O, emissions increase within few years after stabilization, drying and revegetation with grasses to high rates (548 (133-6286) µg N m-2 day-1; median with (range)), exceeding by 1-2 orders of magnitude the typical rates from permafrost-affected soils. Using targeted metagenomics of key N cycling genes, we link the increase in in situ N2O emissions with structural changes of the microbial community responsible for N cycling. Our results highlight the importance of extra N availability from thawing Yedoma permafrost, causing a positive climate feedback from the Arctic in the form of N2O emissions.

2.
Artigo em Inglês | MEDLINE | ID: mdl-12482487

RESUMO

Hydroxy fatty acids (OH-FAs) can be used in the characterization of microbial communities, especially Gram-negative bacteria. We prepared methyl esters of 2- and 3-OH-FAs from the lipid extraction residue of soil, sediment, and biofilm samples without further purification or derivatization of hydroxyl groups. OH-FA methyl esters were analyzed using a gas chromatograph equipped with a mass selective detector (GC-MS). The ions followed in MS were m/z 103 for 3-OH-FAs and m/z 90 and M-59 for 2-OH-FAs. The rapid determination of 3- and 2-OH-FAs concomitantly with phospholipid fatty acids provided more detailed information on the microbial communities present in soil, sediment, and drinking water biofilm.


Assuntos
Biofilmes , Ácidos Graxos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Sedimentos Geológicos/química , Solo/análise , Ésteres
3.
Water Res ; 35(17): 4217-25, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11791852

RESUMO

We studied the influence of electrolytically released copper and silver ions on the microbiological quality in a warm water system of a hospital. The concentration of nontuberculous mycobacteria was followed for three, and that of legionellae and other heterotrophic bacteria in the water for four years. The highest concentrations of copper and silver ions were 220 and 68 microg/l, respectively. Silver ion concentration of about 3 microg/l was sufficient to control the growth of legionellae in circulating warm water. The results showed that it is more difficult to eradicate legionellae from taps and showers: these points were colonized by a small number of legionellae after the metal ion concentrations were increased in the circulating water. A regular use of water eradicated legionellae from the shower. One tap was still used irregularly, and this may be a reason why it still contained small concentrations of legionellae also in the last years of the study. Mycobacteria were occasionally isolated from the circulating water and repeatedly from the shower, even when the metal concentrations were high. To control legionella bacteria in warm water systems, silver concentrations of only 3 microg/l are needed if all taps and showers of the system are regularly used. Such low copper and silver concentrations, however, are not efficient against nontuberculous mycobacteria or other heterotrophic bacteria.


Assuntos
Cobre/química , Legionella , Mycobacteriaceae , Prata/química , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/métodos , Hospitais , Controle de Infecções , Íons , Resíduos de Serviços de Saúde , Dinâmica Populacional , Temperatura , Microbiologia da Água
4.
Water Res ; 36(12): 3045-53, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12171403

RESUMO

The effects of ozone, chlorine, hydrogen peroxide, and permanganate on the aquatic humic matter with different molecular size fractions and the organic acid formation in drinking water treatment were studied. Aquatic humus in lake water (LW), artificially recharged groundwater (AW), and purified artificially recharged groundwater (PW) were fractionated by high-pressure size-exclusion chromatography (HP-SEC) with UV-254nm detection before and after oxidation, a technique which resulted generally in seven peaks. The sum of the molecular size fractions (SMSF) of the LW was reduced by 47% during the bank filtration process, and the SMSF of the AW was reduced by 55% during the process in the water treatment plant. The oxidation of the AW resulted in reductions in the range of 18-35% of the SMSF; the respective range of the PW was 15-69%. However, the content of the total organic carbon (TOC) reduced only slightly, and a high correlation between the TOC and the SMSF (0.911) was observed in the whole material. The greatest decreases appeared in the highest-molecular-weight fractions while the low-molecular-weight fractions remained nearly unchanged. The total content of the six organic small-molecular-weight acids (sum of the organic acids, SOA) (formate, acetate, propionate, pyruvate, oxalate, and citrate) varied between 0.1-5.1% and 0.1-9.7% of the reduced TOC in the AW and the PW, respectively. The formation of the SOA, especially of oxalate, was the greatest after hydrogen peroxide combined with ozonation (as much as 1,100 microg/L), while chlorination resulted in the SOA of < 50 microg/L.


Assuntos
Cloro/química , Substâncias Húmicas/química , Peróxido de Hidrogênio/química , Compostos de Manganês/química , Óxidos/química , Ozônio/química , Poluentes da Água/análise , Purificação da Água/métodos , Cromatografia em Gel , Cromatografia Líquida de Alta Pressão , Monitoramento Ambiental , Água Doce/química , Peso Molecular
5.
Water Res ; 35(7): 1635-40, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11329664

RESUMO

Ozonation is a disinfection technique commonly used in the treatment of drinking water. It destroys harmful microbes, but it also degrades organic matter in water, increasing the bioavailability of organic matter. Recently, it was found that not only organic carbon but also phosphorus can limit the microbial growth in drinking water, which contains high amount of organic matter. We used a bioassay to analyze whether ozone could also increase the microbially available phosphorus (MAP) in drinking water, and whether MAP in ozone-treated water was associated with the growth of heterotrophic microbes. We found that both assimilable organic carbon and MAP concentrations were increased by ozone treatment. In ozonated water, microbial growth was mainly limited by phosphorus, and even minor changes in MAP concentration dramatically increased the growth potential of heterotrophic microbes. In this study, ozonation increased the MAP by 0.08-0.73 microgram P/l, resulting in an increase of 80,000-730,000 CFU/ml in water samples. In contrast to MAP, the content of assimilable organic carbon (AOCpotential) did not correlate with microbial growth. The results show that in water treatment not only AOCpotential but also MAP should be considered as an important factor that can limit microbial growth in drinking water.


Assuntos
Carbono , Ozônio , Fósforo , Microbiologia da Água , Bactérias/crescimento & desenvolvimento , Água Doce , Purificação da Água
6.
Water Res ; 35(7): 1757-65, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11329678

RESUMO

In this project we studied the microbiological quality of soft pipeline deposits removed from drinking water distribution networks during mechanical cleaning. Drinking water and deposit samples were collected from 16 drinking water distribution networks located at eight towns in different parts of Finland. Soft pipeline deposits were found to be the key site for microbial growth in the distribution networks. The microbial numbers in the soft deposits were significantly higher than numbers in running water. The highest microbial numbers were detected in the main deposit pushed ahead by the first swab. The deposits contained high numbers of heterotrophic bacteria, actinomycetes and fungi. Also coliform bacteria were often isolated from deposit samples. Manganese and copper in the deposits correlated negatively with the numbers of heterotrophic bacteria. After a year, the viable microbial numbers in the new deposits were almost as high as in the old deposits before the first mechanical cleaning. The bacterial biomass production was higher in the new than in the old deposits.


Assuntos
Microbiologia da Água , Bactérias , Água Doce
7.
Sci Total Environ ; 204(1): 1-10, 1997 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-9299765

RESUMO

The physicochemical quality of drinking and hot waters of 67 buildings in different parts of Finland was studied. Some of the buildings used processed groundwater and some processed surface water. Drinking water samples were taken from the first tap after the water was led into the building. Hot water samples were taken from taps and showers and from circulating hot water systems. Thy physicochemical quality of drinking water was affected by the origin of raw water used in the water plants. Drinking water from surface water plants contained more organic matter and less metals than water from groundwater plants. The quality goal for total organic carbon (TOC; < 2 mg l-1) was exceeded by all drinking water samples. In groundwaters, the variation in the content of non-purgeable organic carbon (NPOC) was great, probably because artificial groundwaters processed from surface waters were included in this group. Unlike in natural waters, the correlation between KMnO4-number and NPOC in the processed waters was weak. This result shows that KMnO4-number is an inaccurate estimate for organic carbon in processed waters. Corrosion of pipe materials was seen as elevated concentrations of iron and copper. In general, the physicochemical quality of drinking and hot waters in the buildings was rather similar.


Assuntos
Carbono/análise , Água Doce/análise , Metais/análise , Purificação da Água/normas , Cromatografia por Troca Iônica , Ingestão de Líquidos , Finlândia , Temperatura Alta , Concentração de Íons de Hidrogênio , Oxigênio/análise , Permanganato de Potássio/análise , Controle de Qualidade , Espectrofotometria Ultravioleta
8.
Sci Total Environ ; 215(1-2): 9-17, 1998 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-9599453

RESUMO

Chlorinated drinking waters produced from humus-rich waters often have a high content of halogenated organic by-products which increases the mutagenicity of drinking water. With in vitro chlorination experiments we studied the formation of chloroform (CHCl3) and mutagenicity of artificially recharged ground water samples. The water samples where obtained from an artificial ground water plant which infiltrates humus-rich lake water through an esker island. The chlorination experiments showed that bank filtration reduced strongly the formation of chloroform and mutagenicity of chlorinated water. Reduction in the amount of chloroform and mutagenicity in chlorinated waters was strongly associated with the decrease in the total content of organic carbon and with the decrease in molecular weight of organic matter during bank filtration.


Assuntos
Carcinógenos/análise , Clorofórmio/análise , Poluentes Químicos da Água/análise , Filtração , Finlândia , Água Doce , Testes de Mutagenicidade/métodos
9.
Sci Total Environ ; 266(1-3): 153-8, 2001 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-11258812

RESUMO

A novel sediment bubble gas sampler and a subsurface bubble gas collector were designed to measure the ebullition of gases from profundal sediments of aquatic ecosystems. The sediment gas sampler was constructed to collect bubble gas samples directly from the uppermost sediment layers for gas composition analysis. The floating subsurface gas collector, designed to trap the bubbles released naturally from sediments, permitted the measurement of both the volume and the composition of the bubble gas. Due to its low cost, light weight and rapid sampling capability, the gas collector is ideal for studies requiring many replicate collectors. These devices were used for measurement of the ebullition of methane (CH4) and carbon dioxide (CO2) during an open water period from hypereutrophic Lake Postilampi, situated within the midboreal zone in Finland. The bubble gas obtained from the sediment with the sediment gas sampler had higher concentrations of CH4 and CO2 than the bubbles trapped in the gas collectors. This indicated that the bubble gas composition changed, either naturally during the migration of the bubbles from the sediment through the water column to the gas collectors, and/or during their storage in the collectors prior to sampling. The mean CH4 ebullition from Lake Postilampi was estimated to be in the range from 36 to 46 mg m(-2 d(-1), based on the bubble gas CH4 concentrations measured from the gas collectors and sediment, respectively. The bubbles contained only 0.02-0.57% of CO2 and thus, the ebullition had no significance in the release of CO2 from the lake.


Assuntos
Dióxido de Carbono/análise , Monitoramento Ambiental/instrumentação , Sedimentos Geológicos/química , Metano/análise , Gases/análise , Movimentos da Água
10.
Chemosphere ; 48(1): 9-20, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12137063

RESUMO

Disinfection by-products (DBPs) were measured in plant effluents of 35 Finnish waterworks, which utilized different treatment processes and raw water sources. DBPs were measured also from the distribution systems of three waterworks. Di- and trichloroacetic acids, and chloroform were the major DBPs found in treated water samples. The concentration of six haloacetic acids (HAA6) exceeded the concentrations of trihalomethanes (THMs). Chlorinated drinking waters (DWs) originating from surface waters contained the highest concentration of HAA6 and THMs: 108 and 26 microg/l, respectively. The lowest concentrations of DBPs were measured from ozonated and/or activated carbon filtrated and chloraminated DWs. Higher concentrations of HAA6, THMs, and adsorbable organic halogens were measured in summer compared to winter. The levels of chlorinated acetic acids, chloroform, and bromodichloromethane correlated positively with mutagenicity. Past mutagenicity levels of DWs were examined. A major reduction in the use of prechlorination, increased use of chloramine disinfection, and better removal of organic carbon were the most important reasons for the 69% decrease in mutagenicity from 1985 to 1994.


Assuntos
Desinfetantes/química , Abastecimento de Água , Compostos Clorados , Desinfetantes/análise , Monitoramento Ambiental , Finlândia , Testes de Mutagenicidade , Trialometanos/análise , Purificação da Água/métodos
11.
Chemosphere ; 45(6-7): 865-73, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11695607

RESUMO

The purpose of this study was to compare the molecular size distribution (MSD) of natural organic matter (NOM) in raw waters (RW) and drinking waters (DW), and to find out the differences between MSD after different water treatment processes. The MSD of NOM of 34 RW and DW of Finnish waterworks were determined with high-performance size-exclusion chromatography (HPSEC). Six distinct fractions were generally separated from water samples with the TSK G3000SW column, using sodium acetate at pH 7 as an eluent. Large and intermediate humic fractions were the most dominant fractions in surface waters (lakes and rivers), while in artificially recharged groundwaters and natural groundwaters intermediate and small fractions predominated. Water treatment processes removed the two largest fractions almost completely shifting the MSD towards smaller molecular size in DW. Granular activated carbon (GAC) filtration, ozonation, and their combination reduced all humic fractions compared to the conventional treatment. Humic fractions correlated with total organic carbon (TOC) content and chemical oxygen demand, this being especially true in RW. The results demonstrate that the HPSEC method can be applied for a qualitative and also for rough estimate quantitative analyzes of NOM directly from RW and DW samples without sample pretreatment.


Assuntos
Compostos Orgânicos/análise , Poluentes Químicos da Água/análise , Purificação da Água , Abastecimento de Água , Carbono/análise , Cromatografia , Monitoramento Ambiental , Substâncias Húmicas/análise , Estrutura Molecular , Oxigênio/análise , Oxigênio/metabolismo
12.
J Environ Qual ; 30(2): 387-94, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11285898

RESUMO

Concentrations of dissolved methane (CH4), carbon dioxide (CO2), and nitrous oxide (N2O) were measured in the water columns of non-oxygenated and artificially oxygenated, ice-covered eutrophied lakes in the mid-boreal zone in Finland during late winter 1997 and 1999. Sampling was conducted during winter stratification, the critical period for oxygen (O2) deficiency in seasonally ice-covered, thermally stratified lakes. Oxygen concentrations were maintained at least at a moderate level throughout the oxygenated water columns, whereas the non-oxygenated columns suffered anoxic hypolimnia. The mean concentrations of dissolved CH4 exceeding the atmospheric equilibrium were greater in the non-oxygenated water columns (20.6-154 microM) than in the oxygenated ones (0.01-1.41 microM). In contrast, the mean excess CO2 concentrations varied less between the non-oxygenated and oxygenated sites (0.28-0.47 and 0.25-0.31 mM, respectively). Oxygenated water columns had greater mean excess concentrations of N2O (0.018-0.032 microM) than the non-oxygenated ones (0.005-0.024 microM). If the accumulated greenhouse gas stores in the water columns during winter are assumed to be released to the atmosphere during the spring overturn, the global warming potentials (GWP, time horizon 100 yr) of these potential emissions at the non-oxygenated, eutrophic study sites ranged from 177 to 654 g CO2 equivalent (CO2-e) m-2 compared with 144 to 173 g CO2-e m-2 at the oxygenated sites. The increase in the accumulation of CH4 was the main reason for the higher GWP of the non-oxygenated sites. Anthropogenic eutrophication of lake ecosystems can generate increased CH4 emissions due to associated O2 depletion of their sediment and water column.


Assuntos
Dióxido de Carbono/análise , Eutrofização , Efeito Estufa , Metano/análise , Óxido Nitroso/análise , Monitoramento Ambiental , Finlândia , Estações do Ano , Temperatura , Movimentos da Água , Poluição da Água
13.
J Air Waste Manag Assoc ; 51(3): 387-92, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11266102

RESUMO

Simultaneous removal of H2S and CS2 was studied with a peat biofilter inoculated with a Thiobacillus strain that oxidizes both compounds in an acidic environment. Both sulfurous gases at concentrations below 600 mg S/m3 were efficiently removed, and the removal efficiencies were similar, 99%, with an empty bed retention time (EBRT) of more than 60 sec. Concentrations greater than 1300-5000 mg S/m3 caused overloading of the filter material, resulting in high H2SO4 production, accumulation of elemental sulfur, and reduced removal efficiency. The highest sulfur removal rate achieved was 4500 g-S/day/m3 filter material. These results indicate that peat is suitable as a biofilter material for the removal of a mixture of H2S and CS2 when concentrations of gases to be purified are low (less than 600 mg/m3), but it is still odorous and toxic to the environment and humans.


Assuntos
Poluentes Atmosféricos/farmacocinética , Poluição do Ar/prevenção & controle , Dissulfeto de Carbono/farmacocinética , Sulfeto de Hidrogênio/farmacocinética , Thiobacillus/fisiologia , Poluentes Atmosféricos/metabolismo , Dissulfeto de Carbono/metabolismo , Filtração , Sulfeto de Hidrogênio/metabolismo , Solo
14.
J Air Waste Manag Assoc ; 51(1): 11-6, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11218419

RESUMO

A biofiltration technique was developed for removing a mixture of hydrogen sulfide (H2S), methanethiol (MeSH), and dimethyl sulfide (Me2S) from waste gases. Since H2S, especially at high concentrations, disturbs the removal of Me2S, two biotrickling filters with different microbes and operating pH levels were connected in series to create a two-stage system. Different loads of these gases were studied in order to determine their impact on the removal capacity of the system. The microbial consortia for these filters were enriched from the sludge of a Finnish refinery with bubbling H2S or Me2S. Acclimation for Me2S took 2 weeks, though no acclimation time was needed for the other gases. The first filter, at a pH of 2, removed most of the H2S and some of the MeSH and Me2S. The second filter, at a pH of approximately 6.5, removed the rest of the MeSH and most of the Me2S. The total maximum loads of the whole two-stage biotrickling filter were 1150 g/m3/day for H2S-S (suffix S indicates the results are counted as sulfur amounts), 879 g/m3/day for Me2S-S, and 66 g/m3/day for MeSH-S treated in a gas mixture. The average removal efficiencies for all gases tested were 99% or higher.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar/análise , Bactérias/metabolismo , Dimetil Sulfóxido/análise , Sulfeto de Hidrogênio/análise , Eliminação de Resíduos de Serviços de Saúde/instrumentação , Compostos de Sulfidrila/análise , Poluentes Ocupacionais do Ar/metabolismo , Dimetil Sulfóxido/metabolismo , Filtração , Sulfeto de Hidrogênio/metabolismo , Eliminação de Resíduos de Serviços de Saúde/métodos , Oxirredução , Compostos de Sulfidrila/metabolismo
15.
Water Sci Technol ; 47(5): 143-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12701920

RESUMO

The development of microbial communities in biofilms of a drinking water distribution system was monitored, and compared to the microbial communities in water. The microbial communities were studied by phospholipid fatty acid (PLFA) profiles. In drinking water samples the most common PLFAs, with the proportion of 60.9%, were monoenoic fatty acids, such as 16:1omega7c and 18:1omega7c, indicating high abundance of gram-negative bacteria. Instead, in biofilm samples saturated fatty acids, such as 16:0 and 18:0, indicating general biomass, accounted for 54.9-78.4% of the total PLFAs. The proportions of monoenoic fatty acids in biofilm increased from 11.5% to 31.2% with water aging from 22 h to 62 h in the distribution system. In conclusion, water aging affected the structure of microbial communities in biofilms, and the microbes in water differed from those in biofilms. These differences might also reflect the differences in the physiological state of the microbes, which is influenced by water chemistry and by the growth environment, i.e. water or biofilm.


Assuntos
Biofilmes , Biomarcadores/análise , Ecossistema , Ácidos Graxos/análise , Abastecimento de Água , Bactérias , Fatores de Tempo , Microbiologia da Água
16.
Bioresour Technol ; 100(20): 4723-30, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19467859

RESUMO

Drained organic soils are among the most risky soil types as far as their greenhouse gas emissions are considered. Reed canary grass (RCG) is a potential bioenergy crop in the boreal region, but the atmospheric impact of its cultivation is unknown. The fluxes of N(2)O and CH(4) were measured from an abandoned peat extraction site (an organic soil) cultivated with RCG using static chamber and snow gradient techniques. The fluxes were measured also at an adjacent site which is under active peat extraction and it is devoid of any vegetation (BP site). The 4-year average annual N(2)O emissions were low being 0.1 and 0.01 g N(2)O m(-2)a(-1) at the RCG and BP sites, respectively. The corresponding mean annual CH(4) emissions from the RCG and BP sites were also low (0.4 g and 0.9 g CH(4) m(-2)a(-1)). These results highlight for the first time that there are organic soils where cultivation of perennial bioenergy crops is possible with low N(2)O and CH(4) emissions.


Assuntos
Agricultura , Metano/análise , Óxido Nitroso/análise , Phalaris/crescimento & desenvolvimento , Solo , Biomassa , Finlândia , Efeito Estufa , Chuva , Estações do Ano , Neve , Temperatura
17.
Appl Environ Microbiol ; 50(6): 1519-25, 1985 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16346951

RESUMO

Aerobic N(2)O production was studied in nitrifying humus from urea-fertilized pine forest soil. Acetylene and nitrapyrin inhibited both NH(4) oxidation and N(2)O production, indicating that N(2)O production was closely associated with autotrophic NH(4) oxidation. N(2)O production was enhanced by low soil pH; it was negligible above pH 4.7. When soil pH decreased from 4.7 to 4.1, the relative amount of N(2)O-N produced from NH(4)-N oxidized increased exponentially to 20%. There was also some evidence that N(2)O formation was stimulated by salts (potassium sulfate and sodium phosphates). The maximum rate of N(2)O-N production was 0.17 mug of N(2)O-N per g of soil per h. When humus was treated with NO(2), N(2)O evolved immediately, indicating chemical formation, but no N(2)O was formed on the addition of NO(3). The amount of N(2)O-N evolved was 0.6 to 4.6% of NO(2)-N added. A high concentration of NO(2) and low soil pH enhanced chemical production of N(2)O. There was no accumulation of NO(2) during nitrification. The calculations indicated that chemical formation of N(2)O was not the main source of N(2)O during NH(4) oxidation. After the addition of inhibitors of NH(4) oxidation the soils contained NO(3), but no N(2)O was produced. The results suggest that enhanced autotrophic NH(4) oxidation is a potential source of N(2)O in fertilized acid forest soil.

18.
Can J Microbiol ; 37(7): 530-3, 1991 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1913357

RESUMO

Six Campylobacter jejuni and six Campylobacter coli strains were isolated from cows and pigs, and their survival in lake water was compared by viable counts. Campylobacter jejuni survived longer in culturable form than C. coli in untreated and membrane-filtered water both at 4 and 20 degrees C. This difference in survival time may be a reason why C. jejuni is generally isolated from surface waters more frequently than C. coli. Both species survived better in filtered than in untreated water. This suggests that predation and competition for nutrients affect the survival of both Campylobacter species in the aquatic environment.


Assuntos
Campylobacter coli/crescimento & desenvolvimento , Campylobacter jejuni/crescimento & desenvolvimento , Microbiologia da Água , Animais , Infecções por Campylobacter/microbiologia , Bovinos , Suínos , Temperatura , Fatores de Tempo
19.
Can J Microbiol ; 40(12): 993-9, 1994 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7704835

RESUMO

The occurrence of legionellae in the hot water distribution systems of 67 buildings located in different parts of Finland was studied. Most of the buildings were apartment buildings. They had different hot water temperatures, and some received their cold potable water from surface water plants and some from ground water plants. Hot water samples were taken from taps, showers, and water mains just before and after the heat exchanger. Legionella pneumophila was isolated from 30% of the distribution systems. In the legionella-positive samples the legionella concentration varied from < 50 to 3.2 x 10(5) colony-forming units (cfu)/L (mean 2.7 x 10(3) cfu/L). The highest concentration of legionellae was found in the shower water. Legionellae appeared more often and with higher concentrations in hot water systems using cold water processed in surface water plants than in hot water systems associated with ground water plants. A high organic matter content in surface waters might favor the occurrence of legionellae and also the growth of other heterotrophic microbes. Mean water temperature just after heating was slightly higher in the legionella-negative systems than in the legionella-positive systems (53.5 vs. 51.5 degrees C).


Assuntos
Habitação , Legionella pneumophila/isolamento & purificação , Microbiologia da Água , Abastecimento de Água , Finlândia , Temperatura Alta
20.
Can J Microbiol ; 42(8): 811-8, 1996 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8776852

RESUMO

The decontamination of Legionella pneumophila and other heterotrophic microbes by heat flushing in four legionellae-positive hot water systems was studied. Before the decontamination procedure, the concentration of legionellae varied from 3.0 x 10(3) to 3.5 x 10(5) cfu/L and the hot water temperature from 43.6 to 51.5 degrees C. During the contamination the temperature was raised to 60-70 degrees C. All taps and showers were cleaned from sediments and flushed with hot water twice a day for several minutes. The decontamination lasted for 2-4 weeks. In a few weeks the heat-flushing method reduced the concentration of legionellae below the detection limit (50 cfu/L) in the hot circulating water system just before and after the heat exchanger. The high hot water temperature also decreased the viable counts of heterotrophic bacteria, fungi, and total microbial cells determined by the epifluorescent microscopy. However, the eradication of legionellae failed in a water system where the water temperature remained below 60 degrees C in some parts of the system. After the decontamination, the temperature of hot water was lowered to 55 degrees C. Thereafter, all the studied hot water systems were recolonized by legionellae within a few months, showing that the decontamination by heat flushing was temporary. Also, the contamination of other bacteria increased in a few months to the level before decontamination.


Assuntos
Habitação , Legionella pneumophila/isolamento & purificação , Microbiologia da Água , Purificação da Água/métodos , Animais , Contagem de Colônia Microbiana , Descontaminação , Eucariotos/isolamento & purificação , Finlândia , Temperatura Alta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA