Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 45(21): 5950-5953, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33137047

RESUMO

We report on the first, to the best of our knowledge, frequency ratio measurement of an 115In+ singleion clock and a 87Sr optical lattice clock. A hydrogen maser serves as a flywheel oscillator to measure the ratio by independent optical combs. From 89,000 s of measurement time, the frequency ratio fIn/fSr is determined to be 2.952 748 749 874 863 3(23) with 7.7×10-16 relative uncertainty. The measurement creates a new connection in the network of frequency ratios of optical clocks.

2.
Opt Express ; 25(10): 11725-11735, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28788732

RESUMO

We report frequency measurement of the clock transition in an 115In+ ion sympathetically-cooled with Ca+ ions in a linear rf trap. The Ca+ ions are used as a probe of the external electromagnetic field and as the coolant for preparing the cold In+. The frequency is determined to be 1 267 402 452 901 049.9 (6.9) Hz by averaging 36 measurements using an optical frequency comb referenced to the frequency standards located in the same site.

3.
Opt Express ; 20(20): 22034-41, 2012 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-23037353

RESUMO

Optical frequency comparison of the (40)Ca(+) clock transition ν(Ca)((2)S(1/2-)(2D(5/2), 729 nm) against the (87)Sr optical lattice clock transition ν(Sr) ((1)S(0)-(3)P(0), 698 nm) has resulted in a frequency ratio ν(Ca) / ν(Sr) = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν(Ca) / ν(Sr) to reach 1 × 10(-15) in 1000s and yielded a value consistent with that calculated from separate absolute frequency measurements of ν(Ca) using the International Atomic Time (TAI) link. The total uncertainty of the frequency ratio using optical comparison (free from microwave link uncertainties) is smaller than that obtained using absolute frequency measurement, demonstrating the advantage of optical frequency evaluation. We note that the absolute frequency of (40)Ca(+) we measure deviates from other published values by more than three times our measurement uncertainty.


Assuntos
Cálcio/química , Dispositivos Ópticos , Oscilometria/instrumentação , Oscilometria/métodos , Estrôncio/química , Fatores de Tempo , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA