1.
AJR Am J Roentgenol ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39230403

RESUMO

The interpretation of clinical oncologic PET studies has historically used static reconstructions based on SUVs. SUVs and SUV-based images have important limitations, including dependence on uptake times and reduced conspicuity of tracer-avid lesions in organs with high background uptake. The acquisition of dynamic PET images enables additional PET reconstructions via Patlak modeling, which assumes that a tracer is irreversibly trapped by tissues of interest. The resulting multiparametric PET images capture a tracer's net trapping rate (Ki) and apparent volume of distribution (VD), separating the contributions of bound and free tracer fractions to the PET signal captured in the SUV. Potential benefits of multiparametric PET include higher quantitative stability, superior lesion conspicuity, and greater accuracy for differentiating malignant and benign lesions. However, the imaging protocols necessary for multiparametric PET are inherently more complex and time-intensive, despite the recent introduction of automated or semiautomated scanner-based reconstruction packages. In this Review, we examine the current state of multiparametric PET in whole-body oncologic imaging. We summarize the Patlak methodology and relevant tracer kinetics, discuss clinical workflows and protocol considerations, and highlight clinical challenges and opportunities. We aim to help oncologic imagers make informed decisions about whether to implement multiparametric PET in their clinical practices.

2.
J Appl Clin Med Phys ; 25(4): e14315, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38415897

RESUMO

AIM: To report on the performance characteristics of the 5-ring GE Discovery MI PET/CT systems using the AAPM TG-126 report and compare these results to NEMA NU 2-2012 where applicable. MATERIALS AND METHODS: TG-126 testing was performed on two GE 5-Rings Discovery MI scanners. Tests performed included spatial resolution, PET/CT image-registration accuracy, sensitivity, count rate performance, accuracy of corrections, image contrast, scatter/attenuation correction, and image uniformity. All acquired data were analyzed using scanner console or free software tools as described by TG-126 and the results were then compared to published NEMA NU 2-2012 values. RESULTS: Both scanners gave similar resolution results for TG-126 and NEMA NU 2-2012 and were within manufacturer specifications. Image-registration accuracy between PET and CT using our clinical protocol showed excellent results with values ≤1 mm. Sensitivity using TG-126 was 19.43 cps/kBq while for NEMA the value was 20.73 cps/kBq. The peak noise-equivalent counting rate was 2174 kcps at 63.1 kBq/mL and is not comparable to NEMA NU 2-2012 due to differences in phantoms and methods used to measure and calculate this parameter. The accuracy of corrections for count losses for TG-126 were expressed in SUV values and found to be within 10% of the expected SUV measurement of 1. Image contrast and scatter/attenuation correction using the TG-126 method gave acceptable results. Image uniformity assessment resulted in values within the recommended ± 5% limits. CONCLUSION: These results show that the 5-ring GE Discovery MI PET/CT scanner testing using TG-126 is reproducible and has similar results to NEMA NU 2-2012 tests where applicable. We hope these results start to form the basis to compare PET/CT systems using TG-126.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Tomógrafos Computadorizados , Imagens de Fantasmas , Software
3.
J Appl Clin Med Phys ; 23(5): e13619, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35481961

RESUMO

Data driven respiratory gating (DDG) in positron emission tomography (PET) imaging extracts respiratory waveforms from the acquired PET data obviating the need for dedicated external devices. DDG performance, however, degrades with decreasing detected number of coincidence counts. In this paper, we assess the clinical impact of reducing injected activity on a new DDG algorithm designed for PET data acquired with continuous bed motion (CBM_DDG) by evaluating CBM_DDG waveforms, tumor quantification, and physician's perception of motion blur in resultant images. Forty patients were imaged on a Siemens mCT scanner in CBM mode. Reduced injected activity was simulated by generating list mode datasets with 50% and 25% of the original data (100%). CBM_DDG waveforms were compared to that of the original data over the range between the aortic arch and the center of the right kidney using the Pearson correlation coefficient (PCC). Tumor quantification was assessed by comparing the maximum standardized uptake value (SUVmax) and peak SUV (SUVpeak) of reconstructed images from the various list mode datasets using elastic motion deblurring (EMDB) reconstruction. Perceived motion blur was assessed by three radiologists of one lesion per patient on a continuous scale from no motion blur (0) to significant motion blur (3). The mean PCC of the 50% and 25% dataset waveforms was 0.74 ± 0.18 and 0.59 ± 0.25, respectively. In comparison to the 100% datasets, the mean SUVmax increased by 2.25% (p = 0.11) for the 50% datasets and by 3.91% (p = 0.16) for the 25% datasets, while SUVpeak changes were within ±0.25%. Radiologist evaluations of motion blur showed negligible changes with average values of 0.21, 0.3, and 0.28 for the 100%, 50%, and 25% datasets. Decreased injected activities degrades the resultant CBM_DDG respiratory waveforms; however this decrease has minimal impact on quantification and perceived image motion blur.


Assuntos
Neoplasias , Técnicas de Imagem de Sincronização Respiratória , Humanos , Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos
4.
J Appl Clin Med Phys ; 21(1): 158-165, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31816183

RESUMO

Continuous bed motion (CBM) was recently introduced as an alternative to step-and-shoot (SS) mode for PET/CT data acquisition. In CBM, the patient is continuously advanced into the scanner at a preset speed, whereas in SS, the patient is imaged in overlapping bed positions. Previous investigations have shown that patients preferred CBM over SS for PET data acquisition. In this study, we investigated the effect of CBM versus SS on patient breathing and respiratory motion correction. One hundred patients referred for PET/CT were scanned using a Siemens mCT scanner. Patient respiratory waveforms were recorded using an Anzai system and analyzed using four methods: Methods 1 and 2 measured the coefficient of variation (COV) of the respiratory cycle duration (RCD) and amplitude (RCA). Method 3 measured the respiratory frequency signal prominence (RSP) and method 4 measured the width of the HDChest optimal gate (OG) window when using a 35% duty cycle. Waveform analysis was performed over the abdominothoracic region which exhibited the greatest respiratory motion and the results were compared between CBM and SS. Respiratory motion correction was assessed by comparing the ratios of SUVmax, SUVpeak, and CNR of focal FDG uptake, as well as Radiologists' visual assessment of corresponding image quality of motion corrected and uncorrected images for both acquisition modes. The respiratory waveforms analysis showed that the RCD and RCA COV were 3.7% and 33.3% lower for CBM compared to SS, respectively, while the RSP and OG were 30.5% and 2.0% higher, respectively. Image analysis on the other hand showed that SUVmax, SUVpeak, and CNR were 8.5%, 4.5%, and 3.4% higher for SS compared to CBM, respectively, while the Radiologists' visual comparison showed similar image quality between acquisition modes. However, none of the results showed statistically significant differences between SS and CBM, suggesting that motion correction is not impacted by acquisition mode.


Assuntos
Movimento , Neoplasias/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Respiração , Técnicas de Imagem de Sincronização Respiratória/normas , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/metabolismo , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos/metabolismo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos
5.
J Appl Clin Med Phys ; 19(6): 336-340, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30338918

RESUMO

The attenuation of 511 keV photons by the structure of a PET/MR scanner was measured prior to energizing the magnet. The exposure rate from a source of fluorine-18 was measured in air and, with the source placed at the isocenter of the instrument, at various points outside of the scanner. In an arc from 45 to 135 degrees relative to the long axis of the scanner and at a distance of 1.5 m from the isocenter, the attenuation by the scanner is at least 5.6 half-value layers from the MR component alone and at least 6.6 half-value layers with the PET insert installed. This information could inform better design of the radiation shielding for PET/MR scanners.


Assuntos
Radioisótopos de Flúor , Imageamento por Ressonância Magnética/instrumentação , Modelos Teóricos , Fótons , Tomografia por Emissão de Pósitrons/instrumentação , Proteção Radiológica , Imagem Corporal Total/instrumentação , Humanos
6.
J Appl Clin Med Phys ; 16(5): 3-13, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699325

RESUMO

The American Association of Physicists in Medicine (AAPM) and the Society of Nuclear Medicine and Molecular Imaging (SNMMI) recognized the need for a review of the current state of nuclear  medicine physics training and the need to explore pathways for improving nuclear medicine physics training opportunities. For these reasons, the two organizations formed a joint AAPM/SNMMI Ad Hoc Task Force on Nuclear Medicine Physics  Training. The mission of this task force was to assemble a representative group of stakeholders to:• Estimate the demand for board-certified nuclear medicine physicists in the next 5-10 years,• Identify the critical issues related to supplying an adequate number of physicists who have received the appropriate level of training in nuclear medicine physics, and• Identify approaches that may be considered to facilitate the training of nuclear medicine physicists.As a result, a task force was appointed and chaired by an active member of both organizations that included representation from the AAPM, SNMMI, the American Board of Radiology (ABR), the American Board of Science in Nuclear Medicine (ABSNM), and the Commission for the Accreditation of Medical Physics Educational Programs (CAMPEP). The Task Force first met at the AAPM Annual Meeting in Charlotte in July 2012 and has met regularly face-to-face, online, and by conference calls. This manuscript reports the findings of the Task Force, as well as recommendations to achieve the stated mission.


Assuntos
Diagnóstico por Imagem/normas , Educação Médica/normas , Física Médica/educação , Internato e Residência/normas , Medicina Nuclear/educação , Radioterapia (Especialidade)/educação , Competência Clínica , Currículo , Humanos , Relatório de Pesquisa
7.
J Appl Clin Med Phys ; 15(1): 4600, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24423860

RESUMO

Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to-background ratio (the VMSBR model). The purpose of this work was to apply the VMSBR model and six other segmentation algorithms to a sample of lung tumors. PET and 4D CT were performed in the same imaging session for 23 patients (24 tumors) for radiation therapy planning. Internal target volumes (ITVs) were autosegmented on maximum intensity projection (MIP) of cine CT. ITVs were delineated on PET using the following methods: 15%, 35%, and 42% of maximum activity concentration, standardized uptake value (SUV) of 2.5 g/mL, 15% of mean activity concentration plus background, a linear function of mean SUV, and the VMSBR model. Predicted threshold values from each method were compared to measured optimal threshold values, and resulting volume magnitudes were compared to cine-CT-derived ITV. Correlation between predicted and measured threshold values ranged from slopes of 0.29 for the simplest single-threshold techniques to 0.90 for the VMSBR technique. R2 values ranged from 0.07 for the simplest single-threshold techniques to 0.86 for the VMSBR technique. The VMSBR segmentation technique that included volume, motion, and source-to-background ratio, produced accurate ITVs in patients when compared with cine-CT-derived ITV.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Movimento , Tomografia por Emissão de Pósitrons/métodos , Planejamento da Radioterapia Assistida por Computador , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Simulação por Computador , Seguimentos , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imagens de Fantasmas , Prognóstico , Dosagem Radioterapêutica , Estudos Retrospectivos
8.
Eur J Nucl Med Mol Imaging ; 40(12): 1809-16, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23877633

RESUMO

PURPOSE: The objective of this study was to evaluate the role of (18)F-FDG PET/CT in predicting overall survival in inflammatory breast cancer patients undergoing neoadjuvant chemotherapy. METHODS: Included in this retrospective study were 53 patients with inflammatory breast cancer who had at least two PET/CT studies including a baseline study before the start of neoadjuvant chemotherapy. Univariate and multivariate analyses were performed to assess the effects on survival of the following factors: tumor maximum standardized uptake value (SUVmax) at baseline, preoperatively and at follow-up, decrease in tumor SUVmax, histological tumor type, grade, estrogen, progesterone, HER2/neu receptor status, and extent of disease at presentation including axillary nodal and distant metastases. RESULTS: By univariate analysis, survival was significantly associated with decrease in tumor SUVmax and tumor receptor status. Patients with decrease in tumor SUVmax had better survival (P = 0.02). Patients with a triple-negative tumor (P = 0.0006), a Her2/neu-negative tumor (P = 0.038) or an ER-negative tumor (P = 0.039) had worse survival. Multivariate analysis confirmed decrease in tumor SUVmax and triple-negative receptor status as significant predictors of survival. Every 10% decrease in tumor SUVmax from baseline translated to a 15% lower probability of death, and complete resolution of tumor FDG uptake translated to 80% lower probability of death (P = 0.014). Patients with a triple-negative tumor had 4.11 times higher probability of death (P = 0.004). CONCLUSION: Decrease in tumor SUVmax is an independent predictor of survival in patients with inflammatory breast cancer undergoing neoadjuvant chemotherapy. Further investigation with prospective studies is warranted to clarify its role in assessing response and altering therapy.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Inflamatórias Mamárias/diagnóstico , Neoplasias Inflamatórias Mamárias/tratamento farmacológico , Terapia Neoadjuvante , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Inflamatórias Mamárias/patologia , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Retrospectivos , Análise de Sobrevida
9.
Med Phys ; 39(10): 5891-900, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23039628

RESUMO

PURPOSE: Several investigators have shown that noise equivalent count rate (NECR) is linearly proportional to the square of image signal-to-noise ratio (SNR) when PET images are reconstructed using filtered back-projection. However, to our knowledge, none have shown a similar relationship in fully 3D ordered-subset expectation maximization (OSEM) reconstruction. This paper has two aims. The first is to investigate the NECR-SNR relationship for 3D-OSEM reconstruction using phantom studies while the second aim is to evaluate the NECR-SNR relationship using patient data. METHODS: An anthropomorphic phantom was scanned on a GE Discovery-STE (DSTE) PET∕CT scanner in 3D mode with an initial activity concentration of 66.34 kBq∕cc. PET data were acquired over the lower chest∕upper abdomen region in dynamic mode. The experiment was repeated with the same activity concentration on a GE Discovery-RX (DRX) scanner. Care was taken to place the phantom at identical positions in both scanners. PET data were then reconstructed using 3D Reprojection (3D-RP) and 3D-OSEM with different reconstruction parameters and the NECR and SNR for each frame∕image were calculated. SNR(2) was then plotted versus the NECR for each scanner, reconstruction method and parameters. In addition, 40 clinical PET∕CT studies from the two scanners (20 patients∕scanner) were evaluated retrospectively. The patient studies from each scanner were further divided into two subgroups of body mass indices (BMI). Each PET study was acquired in 3D mode and reconstructed using both 3D-OSEM and 3D-RP. The NECR and SNR of the bed position covering the patient liver were calculated for each patient and averaged for each subgroup. Comparisons of the NECR and SNR between scanner types and BMIs were performed using a t-test and a p value less than 0.05 was considered significant. RESULTS: Phantom results showed that SNR(2) versus NECR was linear for 3D-RP reconstruction across all activity concentration on both scanners, as expected. However, when 3D-OSEM was used, this relationship was nonlinear at activity concentrations beyond the peak NECR on both scanners. On the other hand, the plot of SNR(2) versus trues count rate was linear for 3D-OSEM across all activity concentrations on both scanners independent of reconstruction parameters used. In addition, for activity concentrations <30kBq∕cc, phantom results showed a higher SNR (by 12 ± 10%; p < 0.05) and NECR for the DRX scanner compared to DSTE for 3D-RP reconstruction. However, for 3D-OSEM reconstruction, these two scanners had similar SNRs (different by 2% ± 9%; p > 0.05), despite having different NECRs. Patient studies showed a statistically significant difference in NECR as well as the SNR for 3D-RP reconstruction between the two scanners. However, no statistically significant difference was found for 3D-OSEM. A statistically significant difference in both NECR and SNR were found between the different BMI subgroups for both 3D-RP and 3D-OSEM reconstructions. CONCLUSIONS: For the scanners and reconstruction algorithm used in this study, our results suggest that the image SNR cannot be predicted by the NEC when using 3D-OSEM reconstruction particularly for those clinical applications requiring high activity concentration. Instead, our results suggest that image SNR varies with activity concentration and is dominated by the 3D-OSEM reconstruction algorithm and its associated parameters, while not being affected by the scanner type for the range of activity concentrations usually found in the clinic.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Razão Sinal-Ruído , Índice de Massa Corporal , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
J Appl Clin Med Phys ; 13(3): 3599, 2012 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-22584164

RESUMO

A whole-body PET/CT scan extending from the vertex of the head to the toes of the patient is not feasible on a number of commercially available PET/CT scanners due to a limitation in the extent of bed travel on these systems. In such cases, the PET scan has to be divided into two parts: one covering the upper body segment, while the other covering the lower body segment. The aim of this paper is to describe and evaluate, using phantom and patient studies, a software tool that was developed to stitch two body segments and output a single whole-body image set, thereby facilitating the interpretation of whole-body PET scans. A mathematical model was first developed to stitch images from two body segments using three landmarks. The model calculates the relative positions of the landmarks on the two segments and then generates a rigid transformation that aligns these landmarks on the two segments. A software tool was written to implement this model while correcting for radioactive decay between the two body segments, and output a single DICOM whole-body image set with all the necessary tags. One phantom, and six patient studies were conducted to evaluate the performance of the software. In these studies, six radio-opaque markers (BBs) were used as landmarks (three on each leg). All studies were acquired in two body segments with BBs placed in the overlap region of the two segments. The PET/CT images of each segment were then stitched using the software tool to create a single DICOM whole-body PET/CT image. Evaluation of the stitching tool was based on visual inspection, consistency of radiotracer uptake in the two segments, and ability to display the resultant DICOM image set on two independent workstations. The software tool successfully stitched the two segments of the phantom image, and generated a single whole-body DICOM PET/CT image set that had the correct alignment and activity concentration throughout the image. The stitched images were viewed by two independent workstations from two different manufacturers, attesting the ability of the software tool to produce a DICOM compliant image set. The study demonstrated that this software tool allows the stitching of two segments of a whole-body PET/CT scan with minimal user interaction, thereby facilitating the interpretation of whole body PET/CT scans from a number of scanners with limited extent of bed travel.


Assuntos
Aumento da Imagem/métodos , Tomografia por Emissão de Pósitrons/instrumentação , Software , Imagem Corporal Total/instrumentação , Humanos , Tomografia por Emissão de Pósitrons/métodos
11.
Phys Med Biol ; 67(8)2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35313286

RESUMO

Objective. Data-driven gating (DDG) can address patient motion issues and enhance PET quantification but suffers from increased image noise from utilization of <100% of PET data. Misregistration between DDG-PET and CT may also occur, altering the potential benefits of gating. Here, the effects of PET acquisition time and CT misregistration were assessed with a combined DDG-PET/DDG-CT technique.Approach. In the primary PET bed with lesions of interest and likely respiratory motion effects, PET acquisition time was extended to 12 min and a low-dose cine CT was acquired to enable DDG-CT. Retrospective reconstructions were created for both non-gated (NG) and DDG-PET using 30 s to 12 min of PET data. Both the standard helical CT and DDG-CT were used for attenuation correction of DDG-PET data. SUVmax, SUVpeak, and CNR were compared for 45 lesions in the liver and lung from 27 cases.Main results. For both NG-PET (p= 0.0041) and DDG-PET (p= 0.0028), only the 30 s acquisition time showed clear SUVmaxbias relative to the 3 min clinical standard. SUVpeakshowed no bias at any change in acquisition time. DDG-PET alone increased SUVmaxby 15 ± 20% (p< 0.0001), then was increased further by an additional 15 ± 29% (p= 0.0007) with DDG-PET/CT. Both 3 min and 6 min DDG-PET had lesion CNR statistically equivalent to 3 min NG-PET, but then increased at 12 min by 28 ± 48% (p= 0.0022). DDG-PET/CT at 6 min had comparable counts to 3 min NG-PET, but significantly increased CNR by 39 ± 46% (p< 0.0001).Significance. 50% counts DDG-PET did not lead to inaccurate or biased SUV-increased SUV resulted from gating. Improved registration from DDG-CT was equally as important as motion correction with DDG-PET for increasing SUV in DDG-PET/CT. Lesion detectability could be significantly improved when DDG-PET used equivalent counts to NG-PET, but only when combined with DDG-CT in DDG-PET/CT.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Técnicas de Imagem de Sincronização Respiratória , Humanos , Movimento (Física) , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
Front Oncol ; 12: 921473, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36313653

RESUMO

Purpose: We investigated the feasibility of biology-guided radiotherapy (BgRT), a technique that utilizes real-time positron emission imaging to minimize tumor motion uncertainties, to spare nearby organs at risk. Methods: Volumetric modulated arc therapy (VMAT), intensity-modulated proton (IMPT) therapy, and BgRT plans were created for a paratracheal node recurrence (case 1; 60 Gy in 10 fractions) and a primary peripheral left upper lobe adenocarcinoma (case 2; 50 Gy in four fractions). Results: For case 1, BgRT produced lower bronchus V40 values compared to VMAT and IMPT. For case 2, total lung V20 was lower in the BgRT case compared to VMAT and IMPT. Conclusions: BgRT has the potential to reduce the radiation dose to proximal critical structures but requires further detailed investigation.

13.
Med Phys ; 38(4): 2132-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21626946

RESUMO

PURPOSE: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation, or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. The aim of this work is to measure the overall quantitative accuracy of the PEM Flex system and to determine the individual contributions of error from count rate effects, attenuation, and scatter. METHODS: Gelatin phantoms were designed to simulate breasts of different thicknesses (4-12 cm) with varying uniform background activity concentration (AC) (0.007-0.5 microCi/cc), cysts, and lesions (2:1, 5:1, and 10:1 lesion-to-background ratios). The overall error was calculated from ROI measurements in the phantoms with a clinically relevant background AC (0.065 microCi/cc). The error due to count rate effects was determined by comparing the overall error at multiple background AC to the error at a very low background AC (0.007 microCi/cc) where count rate effects are considered negligible. A point source and cold gelatin phantoms of different thicknesses were used to assess the errors due to attenuation and scatter. The maximum pixel values of the point source in gelatin and in air were compared to determine the effect of attenuation, while scatter was evaluated by comparing the sum of all pixel values in gelatin and in air. RESULTS: The AC in the uniform background was underestimated in phantoms of all thicknesses, with the exception of the 4-cm-thick phantoms in which the measured AC was within +/- 7% of the true value (0.065 microCi/cc). The degree of underestimation in the uniform background increased with the phantom thickness, up to 34% +/- 6% in the 12 cm phantoms. The AC in all lesions was underestimated by more than that measured in the background (22% for the 2:1 lesions in the 4 cm phantom) and this underestimation increased with increasing thickness and lesion-to-background ratio (85% for the 10:1 lesions in the 12 cm phantoms). The error due to count rate effects reduced the measured AC with respect to its true value. This error increased with increasing background AC (23% +/- 6% at 0.065 microCi/cc to 85% +/- 1% at 0.5 microCi/cc for the 4 cm phantoms) and decreased with increasing phantom thickness (23% +/- 6% for the 4-cm-thick phantoms to 7% +/- 7% for the 12-cm-thick phantoms at 0.065 microCi/cc). Attenuation was a substantial source of error and reduced the measured AC by 51% +/- 10%-77% +/- 4% in the 4-12 cm phantoms, respectively. Scatter increased the total signal measured in images by a relatively constant amount (23% +/- 9%) for all thicknesses. CONCLUSIONS: Applying corrections for count rate effects, attenuation, and scatter will be essential for the PEM Flex Solo II to be able to produce quantitatively accurate images.


Assuntos
Mamografia/instrumentação , Artefatos , Imagens de Fantasmas , Espalhamento de Radiação , Sensibilidade e Especificidade
14.
Med Phys ; 38(9): 5176-85, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21978062

RESUMO

PURPOSE: A new positron emission mammography (PEM) device (PEM Flex Solo II, Naviscan Inc., San Diego, CA) has recently been introduced and its performance characteristics have been documented. However, no systematic assessment of its limit of detectability has been evaluated. The aim of this work is to investigate the limit of detectability of this new PEM system using a novel, customized breast phantom. METHODS: Two sets of F-18 infused gelatin breast phantoms of varying thicknesses (2, 4, 6, and 8 cm) were constructed with and without (blank) small, shell-less contrast objects (2 mm thick disks) of varying diameters (3-14.5 mm) [volumes: 0.15-3.3 cc] and activity concentration to background ratio (ACR) (2.7-58). For the phantom set with contrast objects, the disks were placed centrally inside the phantoms and both phantom sets were imaged for a period of 10 min on the PEM device. In addition, scans for the 2 and 6 cm phantoms were repeated at different times (0, 90, and 150 min) post phantom construction to evaluate the impact of total activity concentration (count density) on lesion detectability. Each object from each phantom scan was then segmented and placed randomly in a corresponding blank phantom image. The resulting individual images were presented blindly to seven physician observers (two nuclear medicine and five breast imaging radiologists) and scored in a binary fashion (1-correctly identified object, 0-incorrect). The sensitivity, specificity, and accuracy of lesion detectability were calculated and plots of sensitivity versus ACR and lesion diameters for different phantom thicknesses and count density were generated. RESULTS: The overall (mean) detection sensitivity across all variables was 0.68 (95% CI: [0.64, 0.72]) with a corresponding specificity of 0.93 [0.87, 0.98], and diagnostic accuracy of 0.72 [0.70, 0.75]. The smallest detectable object varied strongly as a function of ACR, as sensitivity ranged from 0.36 [0.29, 0.44] for the smallest lesion size (3 mm) to 0.80 [0.75, 0.84] for the largest (14.5 mm). CONCLUSIONS: The detectability performance of this PEM system demonstrated its ability to resolve small objects with low activity concentration ratios which may assist in the identification of early stage breast cancer. The results of this investigation can be used to correlate lesion detectability with tumor size, ACR, count rate, and breast thickness.


Assuntos
Mamografia/instrumentação , Imagens de Fantasmas , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Tamanho do Órgão , Sensibilidade e Especificidade
15.
Med Phys ; 48(2): e31-e35, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33320364

RESUMO

PURPOSE: A Positron Emission Tomography/Computed Tomography quality assurance program is necessary to ensure that patients receive optimal imaging and care. We summarize the AAPM Task Group (TG) 126 report on acceptance and quality assurance (QA) testing of PET/CT systems. METHODS: TG 126 was charged with developing PET/CT acceptance testing and QA procedures. The TG aimed to develop procedures that would allow for standardized evaluation of existing short-axis cylindrical-bore PET/CT systems in the spirit of NEMA NU 2 standards without requiring specialized phantoms or proprietary software tools. RESULTS: We outline eight performance evaluations using common phantoms and freely available software whereby the clinical physicist monitors each PET/CT system by comparing periodic Follow-Up Measurements to Baseline Measurements acquired during acceptance testing. For each of the eight evaluations, we also summarize the expected testing time and materials necessary and the recommended pass/fail criteria. CONCLUSION: Our report provides a guideline for periodic evaluations of most clinical PET/CT systems that simplifies procedures and requirements outlined by other agencies and will facilitate performance comparisons across vendors, models, and institutions.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Software , Humanos , Imagens de Fantasmas
16.
Med Phys ; 37(4): 1408-12, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443462

RESUMO

PURPOSE: Recently, the authors proposed a free-breathing amplitude gating (FBAG) technique for PET/CT scanners. The implementation of this technique required specialized hardware and software components that were specifically designed to interface with commercial respiratory gating devices to generate the necessary triggers required for the FBAG technique. The objective of this technical note is to introduce an in-house device that integrates all the necessary hardware and software components as well as tracks the patient's respiratory motion to realize amplitude gating on PET/CT scanners. METHODS: The in-house device is composed of a piezoelectric transducer coupled to a data-acquisition system in order to monitor the respiratory waveform. A LABVIEW program was designed to control the data-acquisition device and inject triggers into the PET list stream whenever the detected respiratory amplitude crossed a predetermined amplitude range. A timer was also programmed to stop the scan when the accumulated time within the selected amplitude range REACHED a user-set interval. This device was tested using a volunteer and a phantom study. RESULTS: The results from the volunteer and phantom studies showed that the in-house device can detect similar respiratory signals as commercially available respiratory gating systems and is able to generate the necessary triggers to suppress respiratory motion artifacts. CONCLUSIONS: The proposed in-house device can be used to implement the FBAG technique in current PET/CT scanners.


Assuntos
Diagnóstico por Imagem/métodos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Algoritmos , Artefatos , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Software , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Transdutores
17.
Med Phys ; 37(12): 6221-32, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21302779

RESUMO

PURPOSE: Respiratory motion artifacts and partial volume effects (PVEs) are two degrading factors that affect the accuracy of image quantification in PET/CT imaging. In this article, the authors propose a joint motion and PVE correction approach (JMPC) to improve PET quantification by simultaneously correcting for respiratory motion artifacts and PVE in patients with lung/thoracic cancer. The objective of this article is to describe this approach and evaluate its performance using phantom and patient studies. METHODS: The proposed joint correction approach incorporates a model of motion blurring, PVE, and object size/shape. A motion blurring kernel (MBK) is then estimated from the deconvolution of the joint model, while the activity concentration (AC) of the tumor is estimated from the normalization of the derived MBK. To evaluate the performance of this approach, two phantom studies and eight patient studies were performed. In the phantom studies, two motion waveforms-a linear sinusoidal and a circular motion-were used to control the motion of a sphere, while in the patient studies, all participants were instructed to breathe regularly. For the phantom studies, the resultant MBK was compared to the true MBK by measuring a correlation coefficient between the two kernels. The measured sphere AC derived from the proposed method was compared to the true AC as well as the ACs in images exhibiting PVE only and images exhibiting both PVE and motion blurring. For the patient studies, the resultant MBK was compared to the motion extent derived from a 4D-CT study, while the measured tumor AC was compared to the AC in images exhibiting both PVE and motion blurring. RESULTS: For the phantom studies, the estimated MBK approximated the true MBK with an average correlation coefficient of 0.91. The tumor ACs following the joint correction technique were similar to the true AC with an average difference of 2%. Furthermore, the tumor ACs on the PVE only images and images with both motion blur and PVE effects were, on average, 75% and 47.5% (10%) of the true AC, respectively, for the linear (circular) motion phantom study. For the patient studies, the maximum and mean AC/SUV on the PET images following the joint correction are, on average, increased by 125.9% and 371.6%, respectively, when compared to the PET images with both PVE and motion. The motion extents measured from the derived MBK and 4D-CT exhibited an average difference of 1.9 mm. CONCLUSIONS: The proposed joint correction approach can improve the accuracy of PET quantification by simultaneously compensating for the respiratory motion artifacts and PVE in lung/thoracic PET/CT imaging.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Movimento , Tomografia por Emissão de Pósitrons/métodos , Radiografia Torácica/métodos , Respiração , Tomografia Computadorizada por Raios X/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/fisiopatologia , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Tórax/diagnóstico por imagem
18.
Med Phys ; 37(4): 1742-52, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443495

RESUMO

PURPOSE: Hardware integration of fluorodeoxyglucose positron emission tomography (PET) with computed tomography (CT) in combined PET/CT scanners has provided radiation oncologists and physicists with new possibilities for 3-D treatment simulation. The use of PET/CT simulation for target delineation of lung cancer is becoming popular and many studies concerning automatic segmentation of PET images have been performed. Several of these studies consider size and source-to-background (SBR) in their segmentation methods but neglect respiratory motion. The purpose of the current study was to develop a functional relationship between optimal activity concentration threshold, tumor volume, motion extent, and SBR using multiple regression techniques by performing an extensive series of phantom scans simulating tumors of varying sizes, SBR, and motion amplitudes. Segmented volumes on PET were compared with the "motion envelope" of the moving sphere defined on cine CT. METHODS: A NEMA IEC thorax phantom containing six spheres (inner diameters ranging from 10 to 37 mm) was placed on a motion platform and moved sinusoidally at 0-30 mm (at 5 mm intervals) and six different SBRs (ranging from 5:1 to 50:1), producing 252 combinations of experimental parameters. PET images were acquired for 18 min and split into three 6 min acquisitions for reproducibility. The spheres (blurred on PET images due to motion) were segmented at 1% of maximum activity concentration intervals. The optimal threshold was determined by comparing deviations between the threshold volume surfaces with a reference volume surface defined on cine CT. Optimal activity concentration thresholds were normalized to background and multiple regression was used to determine the relationship between optimal threshold, volume, motion, and SBR. Standardized regression coefficients were used to assess the relative influence of each variable. The segmentation model was applied to three lung cancer patients and segmented regions of interest were compared with those segmented on cine CT. RESULTS: The resulting model and coefficients provided a functional form that fit the phantom data with an adjusted R2 = 0.96. The most significant contributor to threshold level was SBR. Surfaces of PET-segmented volumes of three lung cancer patients were within 2 mm of the reference CT volumes on average. CONCLUSIONS: The authors successfully developed an expression for optimal activity concentration threshold as a function of object volume, motion, and SBR.


Assuntos
Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Desenho de Equipamento , Fluordesoxiglucose F18/farmacologia , Humanos , Imageamento Tridimensional , Neoplasias Pulmonares/diagnóstico por imagem , Movimento (Física) , Movimento , Imagens de Fantasmas , Doses de Radiação , Radiografia Torácica/métodos , Espalhamento de Radiação , Propriedades de Superfície , Tomografia Computadorizada por Raios X/métodos
19.
Med Mycol ; 48(6): 817-23, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20109093

RESUMO

To assess whether the type of immune suppression in patients with hematologic malignancies affects the appearance of invasive pulmonary aspergillosis (IPA) on computed tomography (CT), we retrospectively reviewed the CT findings of 66 consecutive patients who were diagnosed with hematologic malignancies and IPA and correlated the findings to patients' IPA risk factors. In our study these risk factors included neutropenia (n = 34, 52%), stem cell transplantation (SCT; n = 30, 45%), graft versus host disease (GVHD; n = 22, 33%), and steroid use (n = 29, 44%). Nodular lesions were the most common finding on CT (n = 54, 82% of the entire patient population). These were seen in 74% of neutropenic patients (n = 25, P > 0.07), 87% of patients following SCT (n = 26, P > 0.35), 95% of patients with GVHD (n = 21, P = 0.04)), and 83% of those receiving steroids (n = 24, P > 0.45). The hypodense sign was often seen in patients without GVHD (n = 17, 39%; P = 0.003). Tree-in-bud opacities were often observed in patients who underwent SCT (n = 10, 33%; P = 0.03). Thus, peripheral nodular lesions are the most common initial finding of IPA in patients with hematologic malignancies, regardless of the mechanism of immunosuppression.


Assuntos
Neoplasias Hematológicas/complicações , Terapia de Imunossupressão/efeitos adversos , Aspergilose Pulmonar Invasiva/patologia , Pulmão/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Neoplasias Hematológicas/tratamento farmacológico , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
20.
Skeletal Radiol ; 39(2): 131-40, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19760279

RESUMO

OBJECTIVE: To determine if the location of the point of maximum standardized uptake value (SUVmax) being included in or not included in the histopathologic slab section corresponded to tumor necrosis or survival. MATERIALS AND METHODS: Twenty-nine osteosarcoma patients underwent post-chemotherapy [fluorine-18]-fluoro-2-deoxy-D: -glucose (FDG) positron-emission tomography-computed tomography (PET/CT) prior to resection. PET/CT images were correlated with slab-section location as determined by photographs or knowledge of specimen processing. The location of the point of SUVmax was then assigned as being 'in' or 'out' of the slab section. Cox's proportional hazard regression was used to evaluate relationships between the location and value of SUVmax and survival. Logistic regression was employed to evaluate tumor necrosis. RESULTS: No correlation was found between the SUVmax location and survival or tumor necrosis. High SUVmax correlated to poor survival. CONCLUSION: High SUVmax value correlated to poor survival. Minimal viable tumor (> 10%) following chemotherapy is a known indicator of poor survival. No correlation was found between the location of SUVmax and survival or tumor necrosis. Therefore, the SUVmax value either does not correspond to a sufficient number of tumor cells to influence tumor necrosis measurement or it was included in the out-of-slab samples that were directed to viable-appearing areas of the gross specimen. Since high SUVmax has been previously found to correspond to poor tumor necrosis, and tumor necrosis is simply an estimate of the amount of viable tumor, SUVmax likely represents many viable tumor cells. Therefore, when not in the slab section, SUVmax was likely included in the tumor necrosis measurement through directed sampling, validating our current method of osteosarcoma specimen analysis.


Assuntos
Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/mortalidade , Fluordesoxiglucose F18 , Interpretação de Imagem Assistida por Computador/métodos , Osteossarcoma/diagnóstico , Osteossarcoma/mortalidade , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Neoplasias Ósseas/metabolismo , Fluordesoxiglucose F18/farmacocinética , Necrose , Osteossarcoma/metabolismo , Prevalência , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Análise de Sobrevida , Taxa de Sobrevida , Texas , Tomografia Computadorizada por Raios X/estatística & dados numéricos