RESUMO

PURPOSE OF REVIEW: The purposes of this study are to review evidence supporting the use of automated office blood pressure (AOBP) measurement and to provide practical guidance for implementing it in clinical settings. RECENT FINDINGS: Mean AOBP readings correlate with awake ambulatory blood pressure monitor (ABPM) values and predict cardiovascular outcomes better than conventional techniques. However, heterogeneity among readings suggests that AOBP does not replace ABPM. Blood pressure (BP) measurement protocols differ among commonly described AOBP devices, but all produce valid BP estimates. Rest periods should not precede AOBP with BpTRU devices but should occur before use with Omron HEM-907 and Microlife WatchBP Office devices. Attended and unattended AOBP appear to produce similar results. This review also describes a framework to aid AOBP's implementation in clinical practice. Evidence supports AOBP as the preferred method for measuring BP in office settings, but this approach should be a complement to out-of-office measurements, such as self-measured BP monitoring or 24-h ABPM, not a substitute for it.


Assuntos
Determinação da Pressão Arterial/métodos , Hipertensão/diagnóstico , Automação , Humanos , Visita a Consultório Médico , Guias de Prática Clínica como Assunto , Atenção Primária à Saúde/organização & administração