Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Sensors (Basel) ; 20(12)2020 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-32560409

RESUMO

Muscle strength is an important clinical outcome in rehabilitation and sport medicine, but options are limited to expensive but accurate isokinetic dynamometry (IKD) or inexpensive but less accurate hand-held dynamometers (HHD). A wearable, self-stabilizing, limb strength measurement device (LSMD) was developed to fill the current gap in portable strength measurement devices. The purpose of this study was to evaluate the reliability and validity of the LSMD in healthy adults. Twenty healthy adults were recruited to attend two strength testing sessions where elbow flexor and extensor strength was measured with the LSMD, with HHD and with IKD in random order, by two raters. Outcomes were intra-rater repeatability, inter-rater reproducibility and inter-session reproducibility using intra-class correlation coefficients (ICC). Limits of agreement and weighted least products regression were used to test the validity of the LSMD relative to the criterion standard (IKD), and calibration formulas derived to improve measurement fidelity. ICC values for the LSMD were >0.90 for all measures of reliability and for both muscle groups, but over-predicted extensor strength and under-predicted flexor strength. Validity was established by transforming the data with the criterion standard-based calibration. These data indicate that the LSMD is reliable and conditionally valid for quantifying strength of elbow flexors and extensors in a healthy adult population.


Assuntos
Cotovelo/fisiologia , Dinamômetro de Força Muscular , Força Muscular , Dispositivos Eletrônicos Vestíveis , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
2.
J Neuroeng Rehabil ; 15(1): 68, 2018 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-30021641

RESUMO

BACKGROUND: The pendulum test is commonly used to quantify knee extensor spasticity, but it is currently unknown to what extent common pendulum test metrics can detect spasticity in patients with neurological injury or disease, and if the presence of flexor spasticity influences the test outcomes. METHODS: A retrospective analysis was conducted on 131 knees, from 93 patients, across four different patient cohorts. Clinical data included Modified Ashworth Scale (MAS) scores for knee extensors and flexors, and years since diagnosis. BioTone™ measures included extensor strength, passive and active range of motion, and pendulum tests of most affected or both knees. Pendulum test metrics included the relaxation index (RI), 1st flexion amplitude (F1amp) and plateau angle (Plat), where RI=F1amp/Plat. Two-way ANOVA tests were used to determine if pendulum test metrics were influenced by the degree of knee flexor spasticity graded by the MAS, and ANCOVA was used to test for confounding effects of age, years since injury, strength and range of motion (ROM). In order to identify the best pendulum test metrics, Receiver Operator Characteristic analysis and logistic regression (LR) analysis were used to classify knees by spasticity status (none or any) and severity (low/moderate or high/severe). RESULTS: Pendulum test metrics for knee extensors were not influenced by degree of flexor spasticity, age, years since injury, strength or ROM of the limb. RI, F1amp and Plat were > 70% accurate in classifying knees by presence of clinical spasticity (from the MAS), but were less accurate (< 70%) for grading spasticity level. The best classification accuracy was obtained using F1amp and Plat independently in the model rather than using RI alone. CONCLUSIONS: We conclude that the pendulum test has good predictive value for detecting the presence of extensor spasticity, independent of the existence of flexor spasticity. However, the ability to grade spasticity level as measured by MAS using the RI and/or F1amp may be limited. Further study is warranted to explore if the pendulum test is suitable for quantifying more severe spasticity.


Assuntos
Eletromiografia/métodos , Articulação do Joelho/fisiopatologia , Espasticidade Muscular/diagnóstico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos
3.
J Neuroeng Rehabil ; 15(1): 117, 2018 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-30541585

RESUMO

BACKGROUND: Although physical activity and exercise is known to benefit people with multiple sclerosis (MS), the ability of these individuals to participate in such interventions is difficult due to the mobility impairments caused by the disease. Keeogo is a lower-extremity powered exoskeleton that may be a potential solution for enabling people with MS to benefit from physical activity and exercise. METHODS: An open-label, randomized, cross-over trial was used to examine the immediate performance effects when using the device, and the potential benefits of using the device in a home setting for 2 weeks. Clinical performance tests with and without the device included the 6 min walk test, timed up and go test and the 10-step stair test (up and down). An activity monitor was also used to measure physical activity at home, and a patient-reported questionnaire was used to determine the amount and extent of home use. Generalized linear models were used to test for trial effects, and correlation analysis used to examine relationships between trial effects and usage. RESULTS: Twenty-nine patients with MS participated. All measures showed small decrements in performance while wearing the device compared to not wearing the device. However, significant improvements in unassisted (Rehab effect) performance were found after using the device at home for 2 weeks, compared to 2 weeks at home without the device, and participants improved their ability to use the device over the trial period (Training effect). Rehab and Training effects were related to the self-reported extent that participants used Keeogo at home. CONCLUSIONS: Keeogo appears to deliver an exercise-mediated benefit to individuals with MS that improved their unassisted gait endurance and stair climbing ability. Keeogo might be a useful tool for delivering physical activity interventions to individuals with mobility impairment due to MS. TRIAL REGISTRATION: ClinicalTrials.gov : NCT02904382 . Registered 19 September 2016 - Retrospectively registered.


Assuntos
Terapia por Exercício , Exoesqueleto Energizado , Esclerose Múltipla/reabilitação , Adulto , Estudos Cross-Over , Feminino , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/reabilitação , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Equilíbrio Postural , Estudos Retrospectivos , Adulto Jovem
4.
Sensors (Basel) ; 17(4)2017 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-28441748

RESUMO

BACKGROUND: The timed-up-and-go test (TUG) is one of the most commonly used tests of physical function in clinical practice and for research outcomes. Inertial sensors have been used to parse the TUG test into its composite phases (rising, walking, turning, etc.), but have not validated this approach against an optoelectronic gold-standard, and to our knowledge no studies have published the minimal detectable change of these measurements. METHODS: Eleven adults performed the TUG three times each under normal and slow walking conditions, and 3 m and 5 m walking distances, in a 12-camera motion analysis laboratory. An inertial measurement unit (IMU) with tri-axial accelerometers and gyroscopes was worn on the upper-torso. Motion analysis marker data and IMU signals were analyzed separately to identify the six main TUG phases: sit-to-stand, 1st walk, 1st turn, 2nd walk, 2nd turn, and stand-to-sit, and the absolute agreement between two systems analyzed using intra-class correlation (ICC, model 2) analysis. The minimal detectable change (MDC) within subjects was also calculated for each TUG phase. RESULTS: The overall difference between TUG sub-tasks determined using 3D motion capture data and the IMU sensor data was <0.5 s. For all TUG distances and speeds, the absolute agreement was high for total TUG time and walk times (ICC > 0.90), but less for chair activity (ICC range 0.5-0.9) and typically poor for the turn time (ICC < 0.4). MDC values for total TUG time ranged between 2-4 s or 12-22% of the TUG time measurement. MDC of the sub-task times were higher proportionally, being 20-60% of the sub-task duration. CONCLUSIONS: We conclude that a commercial IMU can be used for quantifying the TUG phases with accuracy sufficient for clinical applications; however, the MDC when using inertial sensors is not necessarily improved over less sophisticated measurement tools.


Assuntos
Análise e Desempenho de Tarefas , Humanos , Programas de Rastreamento , Reprodutibilidade dos Testes , Tronco , Caminhada , Dispositivos Eletrônicos Vestíveis
5.
Sci Rep ; 14(1): 4417, 2024 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388571

RESUMO

People with Parkinson's disease (PwPD) can benefit from progressive high-intensity exercise facilitated with a lower-extremity exoskeleton, but the mechanisms explaining these benefits are unknown. We explored the relationship between exercise intensity progression and memory and gait outcomes in PwPD who performed 8 weeks (2 × per week) of progressive exercise with and without a lower-extremity powered exoskeleton, as the planned exploratory endpoint analysis of an open-label, parallel, pilot randomized controlled trial. Adults 50-85 years old with a confirmed diagnosis of PD participated. Twenty-seven participants randomized to exercise with (Exo = 13) or without (Nxo = 14) the exoskeleton were included in this exploratory endpoint analysis. Detailed exercise logs were kept and actigraphy was used to measure activity count*min-1 (ACPM) during all exercise sessions. Only the Exo group were able to progressively increase their ACPM over the entire 8-week intervention, whereas the Nxo group plateaued after 4 weeks. Exercise intensity progression correlated with change in the memory sub-scale of the SCOPA-COG and change in gait endurance from the 6MWT, consistent with the prevailing hypotheses linking high-intensity interval exercise to improved muscle and brain function via angiogenic and neurotrophic mechanisms. Facilitating high-intensity exercise with advanced rehabilitation technology is warranted for improving memory and gait endurance in PwPD.Registration: ClinicalTrials.gov, NCT03583879 (7/10/2018).


Assuntos
Exoesqueleto Energizado , Doença de Parkinson , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Terapia por Exercício , Marcha , Exercício Físico
6.
J Neuroeng Rehabil ; 10(1): 61, 2013 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-23782931

RESUMO

BACKGROUND: Spasticity is a prevalent chronic condition among persons with upper motor neuron syndrome that significantly impacts function and can be costly to treat. Clinical assessment is most often performed with passive stretch-reflex tests and graded on a scale, such as the Modified Ashworth Scale (MAS). However, these scales are limited in sensitivity and are highly subjective. This paper shows that a simple wearable sensor system (angle sensor and 2-channel EMG) worn during a stretch-reflex assessment can be used to more objectively quantify spasticity in a clinical setting. METHODS: A wearable sensor system consisting of a fibre-optic goniometer and 2-channel electromyography (EMG) was used to capture data during administration of the passive stretch-reflex test for elbow flexor and extensor spasticity. A kinematic model of unrestricted passive joint motion was used to extract metrics from the kinematic and EMG data to represent the intensity of the involuntary reflex. Relationships between the biometric results and clinical measures (MAS, isometric muscle strength and passive range of motion) were explored. RESULTS: Preliminary results based on nine patients with varying degrees of flexor and extensor spasticity showed that kinematic and EMG derived metrics were strongly correlated with one another, were correlated positively (and significantly) with clinical MAS, and negatively correlated (though mostly non-significant) with isometric muscle strength. CONCLUSIONS: We conclude that a wearable sensor system used in conjunction with a simple kinematic model can capture clinically relevant features of elbow spasticity during stretch-reflex testing in a clinical environment.


Assuntos
Articulação do Cotovelo/fisiopatologia , Eletromiografia/instrumentação , Monitorização Fisiológica/instrumentação , Espasticidade Muscular/diagnóstico , Reflexo de Estiramento/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos , Eletromiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Espasticidade Muscular/fisiopatologia
7.
Eur J Phys Rehabil Med ; 59(2): 270, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37078434

RESUMO

This article was published in Volume 58, issue 5 of publishing year 2022, with a mistake in Figure 4. The correct Figure 4 is the one included in this erratum.

8.
PLoS One ; 18(10): e0292627, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37819932

RESUMO

Rehabilitation therapy plays an essential role in assisting people with stroke regain arm function. Upper extremity robot therapy offers a number of advantages over manual therapies, but can suffer from slacking behavior, where the user lets the robot guide their movements even when they are capable of doing so by themselves, representing a major barrier to reaching the full potential of robot-assist rehabilitation. This is a pilot clinical study that investigates the use of an electromyography-based adaptive assist-as-needed controller to avoid slacking behavior during robotic rehabilitation for people with stroke. The study involved a convenience sample of five individuals with chronic stroke who underwent a robot therapy program utilizing horizontal arm tasks. The Fugl-Meyer assessment (FM) was used to document motor impairment status at baseline. Velocity, time, and position were quantified as performance parameters during the training. Arm and shoulder surface electromyography (EMG) and electroencephalography (EEG) were used to assess the controller's performance. The cross-sectional results showed strong second-order relationships between FM score and outcome measures, where performance metrics (path length and accuracy) were sensitive to change in participants with lower functional status. In comparison, speed, EMG and EEG metrics were more sensitive to change in participants with higher functional status. EEG signal amplitude increased when the robot suggested that the robot was inducing a challenge during the training tasks. This study highlights the importance of multi-sensor integration to monitor and improve upper-extremity robotic therapy.


Assuntos
Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Robótica/métodos , Reabilitação do Acidente Vascular Cerebral/métodos , Estudos Transversais , Extremidade Superior , Resultado do Tratamento , Recuperação de Função Fisiológica
9.
J Orthop Res ; 41(9): 1925-1933, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36922362

RESUMO

The levitation tricompartment offloader (TCO) brace is designed to unload all three knee compartments by reducing compressive forces caused by muscle contraction. This study aimed to determine the effect of the TCO on knee contact forces and quadriceps muscle activity in individuals with knee osteoarthritis. Lower limb kinematics, kinetics, and electromyography data were collected during a chair rise-and-lower task. A three-dimensional inverse dynamics model of the lower leg and foot was used with a sagittal plane knee model to compute knee joint forces. TCO brace use significantly decreased forces in the tibiofemoral [p = 0.001; mean difference, MD (97.5% confidence interval, CI) -0.62 (-0.91, -0.33) body weight (BW)] and patellofemoral [p = 0.001; MD (97.5% CI) -0.88 (-1.36, -0.39) BW] compartments in high-power mode. Significant reductions in quadriceps tendon force [p = 0.002; MD (97.5% CI) -0.53 (-0.83, -0.23) BW] and electromyography intensity of the vastus medialis [p = 0.018, MD (97.5% CI) -30.7 (-59.1, -2.3)] and vastus lateralis [p = 0.012, MD (97.5% CI) -26.2 (-48.5, -3.9)] were also observed. The TCO significantly reduced tibiofemoral and patellofemoral contact forces throughout chair lower, and when knee flexion was greater than 50° during chair rise in high power. These results demonstrate that the TCO reduces contact forces in the tibiofemoral and patellofemoral joint compartments and confirms that the TCO unloads the joint by reducing compressive forces caused by the quadriceps. Clinical significance: The magnitude of knee joint unloading provided by the TCO is similar to that achieved by clinically recommended levels of bodyweight loss and is therefore expected to result in clinical benefits for knee osteoarthritis patients.


Assuntos
Osteoartrite do Joelho , Articulação Patelofemoral , Humanos , Adulto , Osteoartrite do Joelho/terapia , Osteoartrite do Joelho/etiologia , Articulação do Joelho/fisiologia , Fenômenos Mecânicos , Fenômenos Biomecânicos , Peso Corporal
10.
J Biomech Eng ; 134(8): 084502, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22938362

RESUMO

There is increasing interest in wearable sensor technology as a tool for rehabilitation applications in community or home environments. Recent studies have focused on evaluating inertial based sensing (accelerometers, gyroscopes, etc.) that provide only indirect measures of joint motion. Measurement of joint kinematics using flexible goniometry is more direct, and still popular in laboratory environments, but has received little attention as a potential tool for wearable systems. The aim of this study was to compare two goniometric devices: a traditional strain-gauge flexible goniometer, and a fiberoptic flexible goniometer, for measuring dynamic knee flexion/extension angles during activity of daily living: chair rise, and gait; and exercise: deep knee bends, against joint angles computed from a "gold standard" Vicon motion tracking system. Six young adults were recruited to perform the above activities in the lab while wearing a goniometer on each knee, and reflective markers for motion tracking. Kinematic data were collected simultaneously from the goniometers (one on each leg) and the motion tracking system (both legs). The results indicate that both goniometers were within 2-5 degrees of the Vicon angles for gait and chair rise. For some deep knee bend trials, disagreement with Vicon angles exceeded ten degrees for both devices. We conclude that both goniometers can record ADL knee movement faithfully and accurately, but should be carefully considered when high (>120 deg) knee flexion angles are required.


Assuntos
Atividades Cotidianas , Artrometria Articular/instrumentação , Exercício Físico/fisiologia , Joelho/fisiologia , Fibras Ópticas , Estresse Mecânico , Artrometria Articular/normas , Fenômenos Biomecânicos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Movimento , Padrões de Referência , Reabilitação , Adulto Jovem
11.
Eur J Phys Rehabil Med ; 58(5): 723-737, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35708047

RESUMO

BACKGROUND: People with Parkinson's Disease (PD) have difficulty participating in exercise. AIM: The primary objective of this pilot randomized controlled trial (RCT) was to determine if 8 weeks (2x per week) of bilateral exoskeleton (Exo) exercise results in positive changes in cognition and participation in adults with PD compared to exercising without an exoskeleton (Nxo) or wait-list control (Con). DESIGN: Open-label, parallel, pilot randomized controlled trial. SETTING: Neurorehabilitation clinic in a large urban center. POPULATION: Adults 50-85 years old with a confirmed diagnosis of PD. METHODS: Eight weeks of twice-weekly combined aerobic, strength and mobility exercise or wait-list control. Participants were randomly assigned to exercise with no exoskeleton (Nxo), exercise with the exoskeleton (Exo), or waitlist control (Con). Primary endpoints were change in cognitive function (SCOPA-COG) and mood. Secondary endpoints were change in gait speed, six-minute walk test (6MWT), freezing of gait, balance, and PD-specific health and quality of life outcomes. Safety endpoint was analysis of adverse events (AE). RESULTS: Forty participated in the trial (Exo, N.=13; Nxo, N.=14; Con, N.=13). Significant improvement in the Memory & Learning domain of the SCOPA-COG (P=0.014) and 6MWT (P=0.008) were detected for the Exo group compared to the Nxo and/or Con group. No other statistically significant between-groups effects were found. There were no serious or unanticipated AE. CONCLUSIONS: Functional exercise with a low-profile overground exoskeleton showed promising results for improving memory and gait endurance in people with PD across HY stages I-IV. CLINICAL REHABILITATION IMPACT: Exoskeletons can improve participation in high-intensity exercise.


Assuntos
Doença de Parkinson , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia por Exercício/métodos , Marcha , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Velocidade de Caminhada
12.
Appl Nurs Res ; 24(1): 1-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20974052

RESUMO

Symptom management in HIV/AIDS is a critical issue that influences the quality of life of those living with the disease. Although the goals of treating the numbers living with HIV/AIDS have not yet been achieved, availability of antiretroviral therapies (ARVs) has been expanded to many clinical settings in KwaZulu-Natal, the epicenter of HIV infection in South Africa. The South African Department of Health (2007) estimates indicate that 5.54 million South Africans are living with HIV/AIDS, whereas UNAIDS (2007) estimates suggest that 18.8% of the population in South Africa is affected. Because the symptom experience may influence adherence to ARVs and quality of life, this study focused on the prevalence of symptoms reported by patients (N = 149) diagnosed with HIV/AIDS and adherence to medications and appointments. Self-report data were obtained from this community-based sample of HIV-infected patients who received care in outpatient clinics in Durban, KwaZulu-Natal, South Africa. With an average of three side effects, the most frequently reported by the study participants were fatigue/tiredness (41%), rashes (40%), headaches (32%), insomnia (31%), sadness (24%), disturbing dreams (23%), numbness (22%), pain (22%), and self-appearance (20%). On a scale of 1 to 10 (10 being worst possible), those with symptoms reported an average intensity of 4.2 (SD = 2.0), and the degree to which symptoms affected activity levels was 3.2 (SD = 2.2). Although intensity of symptoms and effects on activity levels were strongly correlated (r = .78, p < .001), there were no significant relationships between adherence and the intensity of symptoms or the relationship of symptoms with activity levels. Logistic regression analyses indicate that the presence of a greater number of symptoms was not associated with greater adherence (odds ratio = 2.27, 95% confidence interval = 0.60-8.70, ns). However, those who reported higher adherence were 1.5 times more likely to report greater physical health than low adherers (p = .04). High adherers were also 1.6 times more likely to report greater psychological health than low adherers (p = .03). This suggests that further study is needed to investigate adherence motivations for those living with HIV/AIDS in South Africa because adherence seems not to be linked to the frequency of symptoms or limitations on activity related to symptoms.


Assuntos
Antirretrovirais/administração & dosagem , Antirretrovirais/efeitos adversos , Infecções por HIV , Adulto , Comorbidade , Estudos Transversais , Epidemias/estatística & dados numéricos , Feminino , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Infecções por HIV/enfermagem , Humanos , Masculino , Pessoa de Meia-Idade , África do Sul/epidemiologia , Adulto Jovem
13.
Rehabil Res Pract ; 2020: 2939573, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32395347

RESUMO

Use of bionic overground exoskeletons to assist with neurological rehabilitation is becoming increasingly prevalent and has important implications for physiotherapists and their patients. Yet, there is a paucity of research about the impact of integrating this technology on physiotherapists' work. The purpose of this study was to explore how the training and implementation of using the Ekso robotic exoskeleton with patients affects physiotherapists' work. An exploratory qualitative study of three physiotherapists working at a neurological rehabilitation centre in Eastern Canada was conducted using one-on-one semistructured interviews in July 2017. Audio recordings were transcribed verbatim, and data was coded and analyzed using thematic analysis. Six themes emerged from the data: developing organizational capacity; ethical use of technology; benefits of the equipment; challenges of the equipment; cognitive workload; and the technological environment. The results suggest that the adoption and integration of bionic exoskeletons into rehabilitation practice is not as simple as training physiotherapists and giving them the device. More research is needed to understand the increased cognitive demands of working with patients using technologically advanced exoskeletons within a dynamic, technology-rich healthcare environment, while managing patient expectations and ethical use.

14.
Front Bioeng Biotechnol ; 8: 604860, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33585409

RESUMO

Objective: Off-loader knee braces have traditionally focused on redistributing loads away from either the medial or lateral tibiofemoral (TF) compartments. In this article, we study the potential of a novel "tricompartment unloader" (TCU) knee brace intended to simultaneously unload both the patellofemoral (PF) and TF joints during knee flexion. Three different models of the TCU brace are evaluated for their potential to unload the knee joint. Methods: A sagittal plane model of the knee was used to compute PF and TF contact forces, patellar and quadriceps tendon forces, and forces in the anterior and posterior cruciate ligaments during a deep knee bend (DKB) test using motion analysis data from eight participants. Forces were computed for the observed (no brace) and simulated braced conditions. A sensitivity and validity analysis was conducted to determine the valid output range for the model, and Statistical Parameter Mapping was used to quantify the effectual region of the different TCU brace models. Results: PF and TF joint force calculations were valid between ~0 and 100 degrees of flexion. All three simulated brace models significantly (p < 0.001) reduced predicted knee joint loads (by 30-50%) across all structures, at knee flexion angles >~30 degrees during DKB. Conclusions: The TCU brace is predicted to reduce PF and TF knee joint contact loads during weight-bearing activity requiring knee flexion angles between 30 and 100 degrees; this effect may be clinically beneficial for pain reduction or rehabilitation from common knee injuries or joint disorders. Future work is needed to assess the range of possible clinical and prophylactic benefits of the TCU brace.

15.
Appl Bionics Biomech ; 2019: 4769242, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30863460

RESUMO

OBJECTIVE: Gait asymmetry is a common adaptation observed in lower-extremity amputees, but the underlying mechanisms that explain this gait behavior remain unclear for amputees that use above-knee prostheses. Our objective was to develop a working hypothesis to explain chronic stepping asymmetry in otherwise healthy amputees that use above-knee prostheses. METHODS: Two amputees (both through-knee; one with microprocessor knee, one with hydraulic knee) and fourteen control subjects participated. 3D kinematics and kinetics were acquired at normal, fast, and slow walking speeds. Data were analyzed for the push-off and collision limbs during a double support phase. We examined gait parameters to identify the stepping asymmetry then examined the external work rate (centre of mass) and internal (joint) power profiles to formulate a working hypothesis to mechanistically explain the observed stepping asymmetry. RESULTS: Stepping asymmetry at all three gait speeds in amputees was characterized by increased stance phase duration of the intact limb versus relatively normal stance phase duration for the prosthesis limb. The prosthesis limb contributed very little to positive and negative work during the double support phase of gait. To compensate, the intact leg at heel strike first provided aid to the deficient prosthetic ankle/foot during its push-off by doing positive work with the intact knee, which caused a delayed stance phase pattern. The resulting delay in toe-off of the intact limb then facilitated the energy transfer from the more robust intact push-off limb to the weaker colliding prosthesis side. This strategy was observed for both amputees. CONCLUSIONS: There is a sound scientific rationale for a mechanistic hypothesis that stepping asymmetry in amputee participants is a result of a motor adaptation that is both facilitating the lower-leg trajectory enforced by the prosthesis while compensating for the lack of work done by the prosthesis, the cost of which is increased energy expenditure of the intact knee and both hips.

16.
J Am Med Dir Assoc ; 20(2): 171-176, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30108033

RESUMO

OBJECTIVES: Falls in hospitals lead to adverse patient outcomes and prevention of falls is of upmost importance. Little is known about fall and injury rates in chronic care facilities, which are similar to skilled nursing facilities in the United States. Current fall risk tools in this setting are not well studied. Enhancing the understanding of how patient characteristics relate to fall circumstances is also needed. DESIGN: Retrospective analysis of falls over 3 years on consecutive admissions and discharges. SETTING AND PARTICIPANTS: A 104-bed geriatric chronic care facility. MEASURES: Fall and injury data, descriptive data for patients measuring mobility, balance, cognition, function, and frailty in relation to risk of falls and fall circumstances were analyzed. RESULTS: There were 1141 falls, with an overall fall rate of 8.48 falls per 1000 occupied bed days. The overall injury rate was 37.2 injuries per 100 falls. Being male and frail, having a mobility aid, poor mobility, balance, or cognition were associated with falling. Patients with good balance but poor cognition was more likely to fall outside their room, while those with poor mobility/balance fell more often in their room. The Clinical Frailty Scale performed modestly well at predicting falls with an odds ratio of 2.5 (95% confidence interval 1.9-3.2). CONCLUSIONS AND IMPLICATIONS: Fall rates in chronic care facilities differ from what is reported in other settings. Patient characteristics such as male, use or misuse of a mobility aid, and poor cognition are more common in fallers. Fall circumstances differ in those with poor cognition compared with those with poor mobility and balance. More research focusing on frailty, cognition, and mobility/balance is needed to develop accurate tools that can predict those at a high risk of falls in these facilities.


Assuntos
Acidentes por Quedas , Doença Crônica , Hospitalização , Acidentes por Quedas/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos , Estados Unidos/epidemiologia , Ferimentos e Lesões/epidemiologia
17.
Int J Nurs Stud ; 45(12): 1757-63, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18653188

RESUMO

BACKGROUND: A supportive social environment is critical for those with HIV/AIDS. In KwaZulu-Natal, in South Africa, antiretroviral therapy is available to some HIV-positive individuals. Antiretroviral adherence is an important issue for limiting HIV infection. Adherence to therapy may be linked to social support, particularly amidst the stigma prevalent in HIV. OBJECTIVE: The purpose of this study was to examine characteristics related to social support and antiretroviral medication adherence. DESIGN: This cross-sectional, descriptive study explored the nature of the relationships among social support and other selected variables, including sociodemographic variables, quality of life, and adherence. SETTINGS: After ethical review board approval, the sample of HIV-infected individuals who received care in outpatient clinics were recruited and completed the self-report instruments. PARTICIPANTS: The sample included English and/or isiZulu-speaking (n=149) individuals over the age of 18 years receiving treatment for HIV/AIDS. A total of 149 patients with a diagnosis of HIV/AIDS agreed to participate and completed questionnaires after completing informed consent procedures. The study participants were recruited at four outpatient settings in Durban, KwaZulu-Natal province of South Africa. METHODS: A descriptive, exploratory, cross-sectional design was utilized to explore the research questions: What are the characteristics of social support and the relationship to antiretroviral adherence in KwaZulu-Natal, South Africa? Descriptive statistics and regression analyses were used to answer the research questions. RESULTS: Data analyses indicated that social support scores on the Medical Outcomes Study Social Support Survey were moderate (M=64.4; S.D.=14.7) among the study participants. The number of close friends and family were significantly correlated with a greater sense of social support. Despite this, the lowest scores on the quality-of-life measure using the Medical Outcomes Study Short Form 36 item survey were reported on the Social Functioning Scale. CONCLUSIONS: In summary, the study findings suggest that a supportive social network is essential for those living with HIV/AIDS. However, social functioning and quality of life amidst the stigma of living with HIV in South Africa may be a concern and require further investigation.


Assuntos
População Negra/etnologia , Infecções por HIV/etnologia , Adesão à Medicação/etnologia , Apoio Social , Adaptação Psicológica , Adulto , Terapia Antirretroviral de Alta Atividade/psicologia , Terapia Antirretroviral de Alta Atividade/estatística & dados numéricos , População Negra/educação , População Negra/estatística & dados numéricos , Estudos Transversais , Família/etnologia , Feminino , Amigos/etnologia , Infecções por HIV/tratamento farmacológico , Conhecimentos, Atitudes e Prática em Saúde , Nível de Saúde , Humanos , Masculino , Adesão à Medicação/estatística & dados numéricos , Pessoa de Meia-Idade , Pesquisa Metodológica em Enfermagem , Preconceito , Qualidade de Vida/psicologia , Análise de Regressão , Fatores Socioeconômicos , África do Sul/epidemiologia , Estereotipagem , Inquéritos e Questionários
18.
Physiol Meas ; 39(8): 085001, 2018 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-30019689

RESUMO

OBJECTIVE: To evaluate a new portable toolkit for quantifying upper and lower extremity muscle tone in patients with upper motor neuron syndrome (UMNS). APPROACH: Cross-sectional, multi-site, observational trial to test and validate a new technology. SETTING: Neurorehabilitation clinics at tertiary care hospitals. PARTICIPANTS: Four cohorts UMNS patient, >6 mo post acquired brain injury, spinal cord injury, multiple sclerosis and cerebral palsy, and a sample of healthy age-matched adult controls. MEASURES: Strength: grip, elbow flexor and extensor, and knee extensor; range of motion (ROM): passive ROM (contracture) and passive-active ROM (paresis); objective spasticity: stretch-reflex test for elbow, and pendulum test for knee; subjective spasticity: modified Ashworth scale scores for elbow and knee flexors and extensors. RESULTS: Measures were acquired for 103 patients from three rehabilitation clinics. Results for patient cohorts were consistent with the literature. Grip strength correlated significantly with elbow muscle strength and all patient populations were significantly weaker in upper- and lower-extremity compared to controls. Strength and paresis were correlated for elbow and knee but neither correlated with contracture. Elbow spasticity correlated with strength and paresis but not contracture. Knee spasticity correlated with strength, and subjective spasticity correlated with contracture. SIGNIFICANCE: The BioTone™ toolkit provided comprehensive objective measures for assessing muscle tone in patients with UMNS. The toolkit could be useful for standardizing outcomes measures in clinical trials and for routine practice.


Assuntos
Tono Muscular , Reabilitação Neurológica/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Cotovelo/inervação , Feminino , Humanos , Joelho/inervação , Masculino , Pessoa de Meia-Idade , Neurônios Motores/patologia , Força Muscular , Padrões de Referência , Adulto Jovem
19.
Can Geriatr J ; 21(2): 157-165, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29977431

RESUMO

BACKGROUND: Motor and cognitive impairments are common among older adults and often co-exist, increasing their risk of dementia, falls, and fractures. Gait performance is an accepted indicator of global health and it has been proposed as a valid motor marker to detect older adults at risk of developing mobility and cognitive declines including future falls and incident dementia. Our goal was to provide a gait assessment protocol to be used for clinical and research purposes. METHODS: Based on a consensus that identified common evaluations to assess motor-cognitive interactions in community-dwelling older individuals, a protocol on how to evaluate gait in older adults for the Canadian Consortium on Neurodegeneration in Aging (CCNA) was developed. RESULTS: The CCNA gait assessment includes preferred and fast pace gait, and dual-task gait that comprises walking while performing three cognitively demanding tasks: counting backwards by ones, counting backwards by sevens, and naming animals. This gait protocol can be implemented using an electronic-walkway, as well as by using a regular stopwatch. The latter approach provides a simple manner to evaluate quantitative gait performance in clinics. CONCLUSIONS: Establishing a standardized gait assessment protocol will help to assess motor-cognitive interactions in aging and neurodegeneration, to compare results across studies, and to feasibly implement and translate gait testing in clinics for detecting impending cognitive and mobility decline.

20.
J Altern Complement Med ; 13(5): 527-32, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17604556

RESUMO

BACKGROUND: Acupuncture may improve motor function in patients with chronic hemiparetic stroke, yet the neural mechanisms underlying such an effect are unknown. As part of a sham-controlled, randomized clinical trial testing the efficacy of a 10-week acupuncture protocol in patients with chronic hemiparetic stroke, we examined the relationship between changes in function of the affected upper limb and brain activation using functional magnetic resonance imaging (fMRI). METHODS: Seven (7) chronic hemiparetic stroke patients underwent fMRI and testing of function of the affected upper limb (spasticity and range-of-motion) before and after a 10-week period of verum (N=4) or sham (N=3) acupuncture. The correlation between changes in function of the affected upper limb and brain activation after treatment was tested across patients. RESULTS: We found a significant positive correlation between changes in function of the affected upper limb (spasticity and range of motion) and activation in a region of the ipsilesional motor cortex. Patients treated with verum acupuncture showed a trend toward a greater maximum activation change in this motor cortical area as compared to those treated with sham acupuncture. CONCLUSIONS: Acupuncture may improve function of the affected upper limb in chronic hemiparetic stroke patients by increasing activity in the ipsilesional motor cortex.


Assuntos
Terapia por Acupuntura/métodos , Hemiplegia/reabilitação , Córtex Motor/patologia , Reabilitação do Acidente Vascular Cerebral , Adulto , Idoso , Doença Crônica , Método Duplo-Cego , Feminino , Hemiplegia/etiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Destreza Motora , Projetos Piloto , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA