Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Diabetes Sci Technol ; 12(3): 634-638, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28990436

RESUMO

BACKGROUND: Real-time continuous glucose monitoring is associated with significant benefits for diabetes management. Implantable sensors could overcome some challenges reportedly associated with device visibility, psychosocial functioning and sensor durability. METHODS: A psychosocial assessment was conducted to determine acceptability and impact of an implantable continuous glucose monitoring (CGM) sensor as part of the PRECISE trial. Questionnaires were administered to participants comprising the Diabetes Distress Scale, the CGM impact scale, and bespoke device satisfaction. RESULTS: Fifty-one participants across the United Kingdom (n = 10) and Germany (n = 41) completed the questionnaires. Of these, 90% had T1D, 50% followed an insulin pump therapy regimen, and 45% of the participants were previous CGM users. CGM Impact Scale results show 86% (n = 44) of participants reported feeling better (14% neutral) about their diabetes control with 90% CGM naïve participants and 81% previous CGM users reporting increased confidence about their diabetes management. Furthermore, 73% (n = 37) felt more safe (27% neutral) while sleeping and 78% (n = 39) more confident (22% neutral) about avoiding serious hypoglycemia. Responses correspond with an average improvement in HbA1c from 7.51 to 7.05 ( P < .0001) over the 90 days use of the CGM. Overall, the system was rated highly on ease of use, convenience and comfort. 84% would choose to be inserted again with 93% of CGM naïve participants (86% previous CGM users) reporting minimized burden of diabetes. CONCLUSIONS: Implantable CGM devices are acceptable to users and are evaluated favorably. The considerable majority of participants (93% of first time users and 77% previous CGM users) would like to continue using the system to help manage their diabetes more effectively.


Assuntos
Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/psicologia , Glicemia/análise , Aceitação pelo Paciente de Cuidados de Saúde , Adolescente , Adulto , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Feminino , Humanos , Masculino , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Inquéritos e Questionários
2.
Artigo em Inglês | MEDLINE | ID: mdl-23366679

RESUMO

This article describes the algorithm for a continuous glucose monitor (CGM). The CGM system consists of an external reader and an insertable fluorescence based sensor. The sensor consists of a miniaturized optical sensor that incorporates a biocompatible macromolecular indicator that selectively binds glucose. It is designed to be subcutaneously inserted and allows for the direct measurement of interstitial fluid (ISF) glucose.


Assuntos
Algoritmos , Técnicas Biossensoriais , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Fluorescência , Humanos , Miniaturização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA