Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
IEEE Trans Instrum Meas ; 68(9): 3137-3150, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33223563

RESUMO

The design and performance of the ACE1 (Active Complex Electrode) electrical impedance tomography system for single-ended phasic voltage measurements is presented. The design of the hardware and calibration procedures allow for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.

2.
J Appl Physiol (1985) ; 127(1): 58-70, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31046518

RESUMO

Identifying safe ventilation patterns for patients with acute respiratory distress syndrome remains challenging because of the delicate balance between gas exchange and selection of ventilator settings to prevent further ventilator-induced lung injury (VILI). Accordingly, this work seeks to link ventilator settings to graded levels of VILI to identify injury cost functions that predict injury by using a computational model to process pressures and flows measured at the airway opening. Pressure-volume loops were acquired over the course of ~2 h of mechanical ventilation in four different groups of BALB/c mice. A cohort of these animals were subjected to an injurious bronchoalveolar lavage before ventilation. The data were analyzed with a single-compartment model that predicts recruitment/derecruitment and tissue distension at each time step in measured pressure-volume loops. We compared several injury cost functions to markers of VILI-induced blood-gas barrier disruption. Of the cost functions considered, we conclude that mechanical power dissipation and strain heterogeneity are the best at distinguishing between graded levels of injury and are good candidates for forecasting the development of VILI. NEW & NOTEWORTHY This work uses a predictive single-compartment model and injury cost functions to assess graded levels of mechanical ventilator-induced lung injury. The most promising measures include strain heterogeneity and mechanical power dissipation.


Assuntos
Pulmão/fisiopatologia , Lesão Pulmonar Induzida por Ventilação Mecânica/fisiopatologia , Algoritmos , Animais , Simulação por Computador , Camundongos , Camundongos Endogâmicos BALB C , Respiração com Pressão Positiva/métodos , Respiração , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/fisiopatologia , Volume de Ventilação Pulmonar/fisiologia
3.
IEEE Trans Med Imaging ; 36(9): 1868-1875, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28436855

RESUMO

A real-time implementation of Calderón's method for the reconstruction of a 2-D conductivity from electrical impedance tomography data is presented, in which domain-specific modeling is taken into account. This is the first implementation of Calderón's method that accounts for correct modeling of non-symmetric domain boundaries in image reconstruction. The domain-specific Calderón's method is derived and reconstructions from experimental tank data are presented, quantifying the distortion when correct modeling is not included in the reconstruction algorithm. Reconstructions from human subject volunteers are presented, demonstrating the method's effectiveness for imaging changes due to ventilation and perfusion in the human thorax.


Assuntos
Impedância Elétrica , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Respiração , Tórax , Tomografia
4.
Artigo em Inglês | MEDLINE | ID: mdl-26737189

RESUMO

Electrical Impedance Tomography (EIT) is a technique which can image the varying electrical properties of biological tissues. For clinical use of EIT, it can be advantageous to know both tissue conductivity and permittivity. Presented is the hardware design for the pairwise current injection active complex electrode (ACE1) EIT system which measures phasic voltages for conductivity and permittivity image reconstruction. In this system, alternating current is injected on electrodes on the boundary of a domain and single-ended voltage measurements are used in image reconstructions of the domain's interior and in calculating the current applied at the electrodes.


Assuntos
Tomografia/instrumentação , Criança , Condutividade Elétrica , Impedância Elétrica , Eletrodos , Desenho de Equipamento , Humanos , Interpretação de Imagem Assistida por Computador , Perfusão , Taxa Respiratória , Razão Sinal-Ruído , Tomografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA