Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Clin Monit Comput ; 35(5): 1085-1092, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32734356

RESUMO

Standard monitoring of heart rate, blood pressure and arterial oxygen saturation during endoscopy is recommended by current guidelines on procedural sedation. A number of studies indicated a reduction of hypoxic (art. oxygenation < 90% for > 15 s) and severe hypoxic events (art. oxygenation < 85%) by additional use of capnography. Therefore, U.S. and the European guidelines comment that additional capnography monitoring can be considered in long or deep sedation. Integrated Pulmonary Index® (IPI) is an algorithm-based monitoring parameter that combines oxygenation measured by pulse oximetry (art. oxygenation, heart rate) and ventilation measured by capnography (respiratory rate, apnea > 10 s, partial pressure of end-tidal carbon dioxide [PetCO2]). The aim of this paper was to analyze the value of IPI as parameter to monitor the respiratory status in patients receiving propofol sedation during PEG-procedure. Patients reporting for PEG-placement under sedation were randomized 1:1 in either standard monitoring group (SM) or capnography monitoring group including IPI (IM). Heart rate, blood pressure and arterial oxygen saturation were monitored in SM. In IM additional monitoring was performed measuring PetCO2, respiratory rate and IPI. Capnography and IPI values were recorded for all patients but were only visible to the endoscopic team for the IM-group. IPI values range between 1 and 10 (10 = normal; 8-9 = within normal range; 7 = close to normal range, requires attention; 5-6 = requires attention and may require intervention; 3-4 = requires intervention; 1-2 requires immediate intervention). Results on capnography versus standard monitoring of the same study population was published previously. A total of 147 patients (74 in SM and 73 in IM) were included in the present study. Hypoxic events occurred in 62 patients (42%) and severe hypoxic events in 44 patients (29%), respectively. Baseline characteristics were equally distributed in both groups. IPI = 1, IPI < 7 as well as the parameters PetCO2 = 0 mmHg and apnea > 10 s had a high sensitivity for hypoxic and severe hypoxic events, respectively (IPI = 1: 81%/81% [hypoxic/severe hypoxic event], IPI < 7: 82%/88%, PetCO2: 69%/68%, apnea > 10 s: 84%/84%). All four parameters had a low specificity for both hypoxic and severe hypoxic events (IPI = 1: 13%/12%, IPI < 7: 7%/7%, PetCO2: 29%/27%, apnea > 10 s: 7%/7%). In multivariate analysis, only SM and PetCO2 = 0 mmHg were independent risk factors for hypoxia. IPI (IPI = 1 and IPI < 7) as well as the individual parameters PetCO2 = 0 mmHg and apnea > 10 s allow a fast and convenient conclusion on patients' respiratory status in a morbid patient population. Sensitivity is good for most parameters, but specificity is poor. In conclusion, IPI can be a useful metric to assess respiratory status during propofol-sedation in PEG-placement. However, IPI was not superior to PetCO2 and apnea > 10 s.


Assuntos
Gastrostomia , Propofol , Capnografia , Sedação Consciente , Humanos , Monitorização Fisiológica , Estudos Prospectivos , Respiração
2.
J Clin Med ; 12(9)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37176616

RESUMO

BACKGROUND AND STUDY AIM: The incidence of wound infections after percutaneous endoscopic gastrostomy (PEG) varies widely in recent studies. The present study systematically investigates the underlying risk factors for the development of wound infections in a large cohort of patients over a long-term follow-up period. PATIENTS AND METHODS: A retrospective cohort study of patients undergoing PEG insertion using either the pull or push technique was conducted and patients followed up for 3 years. Tube-related wound infections were identified, and pathogens regularly cultured from wound swabs. Adjusted analysis was performed via univariate and multivariate logistic regression analysis. RESULTS: 616 patients were included in this study. A total of 25% percent of patients developed wound infections upon PEG tube insertion and 6.5% showed recurrent infections. Nicotine abuse (p = 0.01), previous ischemic stroke (p = 0.01) and head and neck cancer (p < 0.001) showed an increased risk for wound infection after PEG placement. Moreover, radio-chemotherapy was associated with the occurrence of wound infections (p < 0.001). Infection rates were similar between pull and push cohorts. The most common bacterial pathogen detected was Enterobacterales (19.2%). Staphylococcus aureus, Pseudomonas aeruginosa and enterococci were frequently detected in recurrent infection (14.2%, 11.4% and 9.6%, respectively). Antibiotic prophylaxis showed no effect on infection rates. CONCLUSIONS: Wound infections after PEG placement are common and occasionally occur as recurrent infections. There is potential for improvement in everyday clinical practice, particularly regarding antibiotic prophylaxis in accordance with guidelines.

3.
United European Gastroenterol J ; 9(4): 469-477, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33887119

RESUMO

BACKGROUND: Before performing endoscopy to remove prophylactic pancreatic stents placed in patients with high risk of post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP), X-ray imaging is recommended to confirm the stents position in the pancreatic duct. OBJECTIVES: The aim of the present study was to investigate the feasibility of prophylactic pancreatic stent detection by transabdominal ultrasonography, to reduce the burden of X-ray imaging, which is currently the golden standard. METHODS: All patients who received a pancreatic stent for PEP prophylaxis were included in the present prospective trial. First, stent position was determined by transabdominal ultrasonography. Afterwards, it was verified by X-ray imaging. Retained stents were removed by esophagogastroduodenoscopy. Dislocated stents needed no further intervention. RESULTS: Fourty-one patients were enrolled in this study. All prophylactic pancreatic stents were straight 6 cm long 5 Fr stents with external flap. All stents were removed between day 1 and 10 (median: 3 days) in all cases. In 34 of 41 cases (83.0%), the pancreatic stent was still in place on the day of examination. Twenty-nine of 34 (85.3%) stents were detected correctly by transabdominal ultrasonography. Overlying gas prevented visualization of the pancreas in 3/41 (7.3%) cases. Sensitivity of sonographic detection of the stent was 93.5% (29/31). Six of seven stents were determined correctly as dislocated by ultrasonography. Here, specificity was 85.7%. A positive predictive value of 96.7% (29/30) was examined. The negative predictive value was 75.0% (6/8). CONCLUSION: Transabdominal ultrasonography detects the majority of prophylactic pancreatic stents. Thereby, it helps to identify patients with an indication for endoscopy sufficiently. X-ray imaging could subsequently be omitted in about 70% of examinations, reducing the radiation exposure for the patient and the endoscopy staff.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Remoção de Dispositivo , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/cirurgia , Pancreatite/prevenção & controle , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Radiografia , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA