RESUMO
PURPOSE: Assessing the diagnostic performance and supplementary value of whole-body computed tomography scout view (SV) images in the detection of thoracolumbar spine injuries in early resuscitation phase and identifying frequent image quality confounders. METHODS: In this retrospective database analysis at a tertiary emergency center, three blinded senior experts independently assessed SV to detect thoracolumbar spine injuries. The findings were categorized according to the AO Spine classification system. Confounders impacting SV image quality were identified. The suspected injury level and severity, along with the confidence level, were indicated. Diagnostic performance was estimated using the caret package in R programming language. RESULTS: We assessed images of 199 patients, encompassing 1592 vertebrae (T10-L5), and identified 56 spinal injuries (3.5%). Among the 199 cases, 39 (19.6%) exhibited at least one injury in the thoracolumbar spine, with 12 (6.0%) of them displaying multiple spinal injuries. The pooled sensitivity, specificity, and accuracy were 47%, 99%, and 97%, respectively. All experts correctly identified the most severe injury of AO type C. The most common image confounders were medical equipment (44.6%), hand position (37.6%), and bowel gas (37.5%). CONCLUSION: SV examination holds potential as a valuable supplementary tool for thoracolumbar spinal injury detection when CT reconstructions are not yet available. Our data show high specificity and accuracy but moderate sensitivity. While not sufficient for standalone screening, reviewing SV images expedites spinal screening in mass casualty incidents. Addressing modifiable factors like medical equipment or hand positioning can enhance SV image quality and assessment.
Assuntos
Traumatismo Múltiplo , Fraturas da Coluna Vertebral , Traumatismos da Coluna Vertebral , Humanos , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/lesões , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/lesões , Tomografia Computadorizada por Raios X/métodos , Traumatismos da Coluna Vertebral/diagnóstico por imagemRESUMO
PURPOSE: Allogeneic blood transfusion (ABT) is current standard of blood replenishment despite known complications. Salvaged blood transfusion (SBT) addresses majority of such complications. Surgeons remain reluctant to employ SBT in metastatic spine tumour surgery (MSTS), despite ample laboratory evidence. This prompted us to conduct a prospective clinical study to ascertain safety of intraoperative cell salvage (IOCS), in MSTS. METHODS: Our prospective study included 73 patients who underwent MSTS from 2014 to 2017. Demographics, tumour histology and burden, clinical findings, modified Tokuhashi score, operative and blood transfusion (BT) details were recorded. Patients were divided based on BT type: no blood transfusion (NBT) and SBT/ABT. Primary outcomes assessed were overall survival (OS), and tumour progression was evaluated using RECIST (v1.1) employing follow-up radiological investigations at 6, 12 and 24 months, classifying patients with non-progressive and progressive disease. RESULTS: Seventy-three patients [39:34(M/F)] had mean age of 61 years. Overall median follow-up and survival were 26 and 12 months, respectively. All three groups were comparable for demographics and tumour characteristics. Overall median blood loss was 500 mL, and BT was 1000 mL. Twenty-six (35.6%) patients received SBT, 27 (37.0%) ABT and 20 (27.4%) NBT. Females had lower OS and higher risk of tumour progression. SBT had better OS and reduced risk of tumour progression than ABT group. Total blood loss was not associated with tumour progression. Infective complications other than SSI were significantly (p = 0.027) higher in ABT than NBT/SBT groups. CONCLUSIONS: Patients of SBT had OS and tumour progression better than ABT/NBT groups. This is the first prospective study to report of SBT in comparison with control groups in MSTS.
Assuntos
Transfusão de Sangue Autóloga , Neoplasias da Coluna Vertebral , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/cirurgia , Neoplasias da Coluna Vertebral/patologia , Transfusão de SangueRESUMO
PURPOSE: The development of spinal implants marks a watershed in the evolution of metastatic spine tumour surgery (MSTS), which has evolved from standalone decompressive laminectomy to instrumented stabilization and decompression with reconstruction when necessary. Fusion may not be feasible after MSTS due to poor quality of graft host bed along with adjunct chemotherapy and/or radiotherapy postoperatively. With an increase in the survival of patients with spinal tumours, there is a probability of an increase in the rate of implant failure. This review aims to help establish a clear understanding of implants/constructs used in MSTS and to highlight the fundamental biomechanics of implant/construct failures. METHODS: Published literature on implant failure after spine surgery and MSTS has been reviewed. The evolution of spinal implants and their role in MSTS has been briefly described. The review defines implant/construct failures using radiological parameters that are practical, feasible, and derived from historical descriptions. We have discussed common modes of implant/construct failure after MSTS to allow further understanding, interception, and prevention of catastrophic failure. RESULTS: Implant failure rates in MSTS are in the range of 2-8%. Variability in patterns of failure has been observed based on anatomical region and the type of constructs used. Patients with construct/implant failures may or may not be symptomatic and present either as early (< 3months) or late failures (> 3months). It has been noted that not all the implant failures after MSTS result in revisions. CONCLUSION: Based on the observed radiological criteria and clinical presentations, we have proposed a clinico-radiological classification for implant/construct failure after MSTS.
Assuntos
Descompressão Cirúrgica/efeitos adversos , Próteses e Implantes/efeitos adversos , Falha de Prótese/etiologia , Neoplasias da Coluna Vertebral/cirurgia , Descompressão Cirúrgica/instrumentação , Descompressão Cirúrgica/métodos , Humanos , Metais/efeitos adversos , Falha de Prótese/efeitos adversos , Neoplasias da Coluna Vertebral/secundário , Coluna Vertebral/patologia , Coluna Vertebral/cirurgiaRESUMO
Endovascular coil occlusion of ruptured cerebral aneurysms has a higher rate of rebleeding compared to surgical clipping. Initial aneurysm coil occlusion rate (OR) is the strongest available predictor of aneurysm rebleeding. Standard clinical subjective occlusion rating (SOR) is limited by subjective bias. Therefore, computerized occlusion rating (COR) was introduced. Its superiority was established for experimental and human aneurysms. In the present clinical study, we aimed to evaluate COR as a risk factor for postprocedural reruptures (PPRs) and intraprocedural reruptures (IPRs). In our series of 249 consecutive patients treated in our institution, we observed 7 (2.8%) cases with IPR and 7 (2.8%) cases with PPR. These patients were analyzed in the present study. Mean COR value was 85% (range 71-96%). In 12 (85.7%) cases, COR was lower than SOR. In aneurysms with a COR of 95% or higher, no PPR occurred. All patients with IPR harbored multiple aneurysms. In -conclusion, our data showed a distinct tendency of potentially dangerous overestimations when using SOR compared to the objectively measured COR values. IPR was always associated with multiple aneurysms.
Assuntos
Aneurisma Roto/cirurgia , Diagnóstico por Computador/métodos , Hemorragia Subaracnóidea/etiologia , Adulto , Idoso , Feminino , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/cirurgia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Índices de Gravidade do Trauma , Resultado do TratamentoRESUMO
INTRODUCTION: Multiple myeloma (MM) is the most frequent primary malignancy of the spine. We aimed to investigate the clinical presentation, surgical indications and outcomes, complications, survival, and its influencing factors in surgically treated MM patients with symptomatic involvement of the spine (SIS). METHODS: Retrospective analysis of prospectively collected data. Out of 350 MM patients treated at our institution over a period of 12 years (2006-2018), we identified 24 patients who were surgically treated for SIS. We collected data on demographics, clinical presentation, comorbidities, surgical indications, and outcomes and investigated the factors predisposing to postoperative complications and survival. RESULTS: The median follow-up duration was 85 months; median overall survival (OS) was 50 months. Clinical presentation at admission included pain (88%), sensory and/or motor deficit (67%), and bowel/bladder dysfunction (25%). Symptomatic pathological fractures were seen in 33%. Predominant surgical indications were rapid neurological deterioration with or without spinal cord compression (SCC), followed by mechanical instability. The majority of our patients benefited from surgery in terms of pain reduction in the short term as well as in the long term. There were 21% patients with surgical-related complications (<3 months). Surgical site infections occurred in 17%, without any obvious factors predisposing to infective complications. Neurological deterioration during hospital stay, especially in the presence of motor deficit and/or bowel/bladder dysfunction, significantly reduced OS. CONCLUSIONS: Sudden-onset neurological deterioration was the predominant factor leading to surgery. We achieved good short- and long-term pain reduction. Surgery is a valuable option for MM patients with SIS who present with rapid neurological deterioration with or without SCC and/or mechanical instability.
RESUMO
Carbon fibre reinforced polyether ether ketone (CFR-PEEK) is a suitable material to replace metal implants in orthopaedic surgery. The radiolucency of CFR-PEEK allows an optimal visualisation of the bone and soft tissue structures. We aimed to assess the performance and radiological and clinical outcomes of anterior cervical discectomy and fusion (ACDF) with CFR-PEEK anterior cervical plating (ACP) under first use clinical conditions. We retrospectively studied the prospectively-collected data of 42 patients who underwent ACDF with CFR-PEEK ACP between 2011 and 2016. We assessed clinical outcome (Odom's criteria, complications) and radiological parameters (global and segmental cervical lordosis, Bridwell score for fusion, adjacent segment degeneration) preoperatively, immediately post-operatively, and after a 12-month follow-up period. Patients' satisfaction was excellent, good, fair, and poor in 12, 19, 3, and 1 patients, respectively. Two patients developed dysphagia. No hardware failure occurred. Compared with preoperative radiographs, we observed a gain of global cervical lordosis and segmental lordosis (7.4 ± 10.1 and 5.6 ± 7.1 degrees, respectively) at the 12-month follow-up. Bridwell IF grades I, II, and III were observed in 22, 6, and 7 patients, respectively. The 12-month adjacent segment degeneration-free and adjacent segment disease-free survival rates were 93.1% and 96.3%, respectively. We observed a dysphagia rate of 5.7% and a reoperation rate of 4.8%. In conclusion, CFR-PEEK ACP shows positive outcomes in terms of implant safety, restoration of cervical lordosis, and functional recovery, and is suitable for ACDF.
RESUMO
The aim of this study was to assess the performance of a new vacuum plasma sprayed (VPS) titanium-coated carbon/polyetheretherketone (PEEK) cage under first use clinical conditions. Forty-two patients who underwent a one or two segment transforaminal lumbar interbody fusion (TLIF) procedure with a new Ca/PEEK composite cage between 2012 and 2016 were retrospectively identified by an electronic patient chart review. Fusion rates (using X-ray), patient's satisfaction, and complications were followed up for two years. A total of 90.4% of the patients were pain-free and satisfied after a follow up (FU) period of 29.1 ± 9 (range 24-39) months. A mean increase of 3° in segmental lordosis in the early period (p = 0.002) returned to preoperative levels at final follow-ups. According to the Bridwell classification, the mean 24-month G1 fusion rate was calculated as 93.6% and the G2 as 6.4%. No radiolucency around the cage (G3) or clear pseudarthrosis could be seen (G4). In conclusion, biological properties of the inert, hydrophobic surface, which is the main disadvantage of PEEK, can be improved with VPS titanium coating, so that the carbon/PEEK composite cage, which has great advantages in respect of biomechanical properties, can be used safely in TLIF surgery. High fusion rates, good clinical outcome, and low implant-related complication rates without the need to use rhBMP or additional iliac bone graft can be achieved.
RESUMO
Despite the increased use of intracranial neuromonitoring during experimental subarachnoid hemorrhage (SAH), coordinates for probe placement in rabbits are lacking. This study evaluates the safety and reliability of using outer skull landmarks to identify locations for placement of cerebral blood flow (CBF) and intraparenchymal intracranial pressure (ICP) probes. Experimental SAH was performed in 17 rabbits using an extracranial-intracranial shunt model. ICP probes were placed in the frontal lobe and compared to measurements recorded from the olfactory bulb. CBF probes were placed in various locations in the frontal cortex anterior to the coronary suture. Insertion depth, relation to the ventricular system, and ideal placement location were determined by post-mortem examination. ICP recordings at the time of SAH from the frontal lobe did not differ significantly from those obtained from the right olfactory bulb. Ideal coordinates for intraparenchymal CBF probes in the left and right frontal lobe were found to be located 4.6±0.9 and 4.5±1.2 anterior to the bregma, 4.7±0.7mm and 4.7±0.5mm parasagittal, and at depths of 4±0.5mm and 3.9±0.5mm, respectively. The results demonstrate that the presented coordinates based on skull landmarks allow reliable placement of intraparenchymal ICP and CBF probes in rabbit brains without the use of a stereotactic frame.