Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Obes Surg ; 34(5): 1737-1741, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38528214

RESUMO

BACKGROUND: Obesity is a risk factor for hyperuricemia and gout, while weight reduction can reduce urate levels. The aim of this study was to examine the effect of bariatric surgery on longitudinal serum urate levels. METHODS: We performed a retrospective observational study of 283 patients who had undergone bariatric surgery [237 (83.7%) gastric bypass, 34 (12.0%) sleeve gastrectomy and 12 (4.2%) gastric banding] and were followed up for 2 years. The results shown represent mean (standard deviation). RESULTS: Bariatric surgery was associated with significant reduction in serum urate from baseline level of 0.343 (0.086) mmol/L to 0.296 (0.076) mmol/L (p < 0.001) at 12 months and 0.286 (0.073) mmol/L (p < 0.001) at 24 months, including in men and women, and in patients with or without diabetes. Patients with elevated urate levels at baseline, who comprised 27.2% of the total cohort, achieved reduction in levels by 4 months. CONCLUSION: Bariatric surgery leads to significant reduction in serum urate levels at 12 and 24 months. This could reduce incidence of gout and need for prophylactic medication(s).


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Gota , Obesidade Mórbida , Masculino , Humanos , Feminino , Ácido Úrico , Obesidade Mórbida/cirurgia , Obesidade/complicações , Obesidade/cirurgia , Cirurgia Bariátrica/métodos , Derivação Gástrica/métodos , Estudos Retrospectivos , Gastrectomia/métodos , Resultado do Tratamento
2.
Biosens Bioelectron ; 20(2): 328-37, 2004 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15308238

RESUMO

A novel and patented procedure is described for the sonochemical fabrication of a new class of microelectrode array based sensor with electrode element populations of up to 2 x 10(5) cm(-2). For some years it has been accepted that microelectrode arrays offer an attractive route for lowering minimum limits of detection and imparting stir (convectional mass transport) independence to sensor responses; despite this no commercial biosensors, to date, have employed microelectrode arrays, largely due to the cost of conventional fabrication routes that have not proved commercially viable for disposable devices. Biosensors formed by our sonochemical approach offer unrivalled sensitivity and impart stir independence to sensor responses. This format lends itself for mass fabrication due to the simplicity and inexpensiveness of the approach; in the first instance impedimetric and amperometric sensors are reported for glucose as model systems. Sensors already developed for ethanol, oxalate and a number of pesticide determinations will be reported in subsequent publications.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Glucose Oxidase/química , Glucose/análise , Glucose/química , Microeletrodos , Sonicação , Técnicas Biossensoriais/métodos , Materiais Revestidos Biocompatíveis/química , Eletroquímica/métodos , Enzimas Imobilizadas/análise , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Glucose Oxidase/análise , Manufaturas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA