1.
Catheter Cardiovasc Interv ; 62(3): 298-302, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15224294

RESUMO

Intervention of long coronary lesions remains problematic, and optimal treatment strategy is yet to be determined. Despite advancement of stent technology, data are few regarding the efficacy of overlapping stents vs. a single long stent in long coronary lesions. This study was performed to evaluate the results of those strategies for long coronary lesions and to determine the predictors of in-stent restenosis (ISR). Sixty-four lesions (> 20 mm) in 64 patients were treated with either one long stent (group 1, n = 32) or two overlapping stents (group 2, n = 32). Overlapping stents were used at tortuous or calcified lesions and at lesions with diameter discrepancy or significant dissection. Immediate results, follow-up clinical and angiographic outcomes, and predictors of ISR were evaluated. Procedures were successful in all patients in both groups. Clinical and angiographic follow-ups were performed in 54 (84%) cases and 50 (78%) cases, respectively. During the follow-up, major adverse cardiac event occurred in 36% of group 1 and 29% of group 2 (P = 0.56). Six-month ISR rates were 39% in group 1 and 41% in group 2 (P = 0.91). Age (>/= 65 years old) was an independent risk factor of ISR (54% vs. 23%; OR = 4.4; P = 0.04), and distal reference diameter (RD) of less than 2.5 mm tended to predict ISR in multivariate analysis (60% vs. 25%; OR = 3.5; P = 0.06). In conclusion, stent overlapping can be used with outcome similar to that of one long stent in long coronary lesions. The optimal result may be obtained by considering the patient's age and the distal vessel diameter of the lesion.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 60(3): 335-8, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14571483

RESUMO

Spontaneous renal artery dissection (SRAD) is a rare condition that occurs before renal infarction. Using percutaneous intervention to treat SRAD remains controversial because it is not clear whether it is feasible or effective. We describe a 48-year-old male patient with SRAD complicated with renal infarction who was successfully treated with percutnaeous angioplasty and renal artery stenting.


Assuntos
Angioplastia com Balão , Dissecção Aórtica/terapia , Infarto/terapia , Rim/irrigação sanguínea , Dissecção Aórtica/diagnóstico por imagem , Implante de Prótese Vascular , Terapia Combinada , Humanos , Infarto/diagnóstico por imagem , Rim/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Artéria Renal/diagnóstico por imagem , Artéria Renal/patologia , Artéria Renal/cirurgia , Ruptura Espontânea/diagnóstico por imagem , Ruptura Espontânea/terapia , Stents , Tomografia Computadorizada por Raios X