Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Basic Transl Sci ; 6(3): 189-198, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33778208

RESUMO

Exercise intolerance remains one of the major factors determining quality of life in heart failure patients. In 6 patients with heart failure with preserved ejection fraction (HFpEF) undergoing invasive cardiopulmonary exercise testing, balloon inflation within the inferior vena cava (IVC) was performed during exercise to reduce and maintain pulmonary arterial (PA) pressures. Partial IVC occlusion significantly reduced PA pressures without reducing cardiac output. Partial IVC occlusion significantly reduced respiratory rate at matched levels of exercise. These findings highlight the importance of pulmonary pressures in the pathophysiology of HFpEF and suggest that therapies targeting hemodynamics may improve symptoms and exercise capacity in these patients.

2.
Acta Biomater ; 62: 385-396, 2017 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-28842334

RESUMO

A major limitation with current assessments of corrosion in metallic medical devices is the lack of correlation between in-vitro and in-vivo corrosion performance. Therefore, the objective of this study was to elucidate the relationship between pitting corrosion measured by breakdown potentials (Eb) in ASTM F2129 testing and corrosion resistance in-vivo. Four groups of Nitinol stents were manufactured using different processing methods to create unique surface properties. The stents were implanted into iliac arteries of minipigs for six months and explanted for corrosion analysis. Scanning electron microscopy and energy dispersive X-ray spectrometry analyses indicated that stents with a thick complex thermal oxide (420nm) and high corrosion resistance in-vitro (Eb=975±94mV) were free from detectable corrosion in-vivo and exhibited no changes in Ni/Ti ratio when compared to non-implanted controls. This result was also found in mechanically polished stents with a thin native oxide (4nm; Eb=767±226mV). In contrast, stents with a moderately thick thermal oxide (130nm) and low corrosion resistance in-vitro (Eb=111±63mV) possessed corrosion with associated surface microcracks in-vivo. In addition, Ni/Ti ratios in corroded regions were significantly lower compared to non-corroded adjacent areas on explanted stents. When stents were minimally processed (i.e. retained native tube oxide from the drawing process), a thick thermal oxide was present (399nm) with low in-vitro corrosion resistance (Eb=68±29mV) resulting in extensive in-vivo pitting. These findings demonstrate that functional corrosion testing combined with a detailed understanding of the surface characteristics of a Nitinol medical device can provide insight into in-vivo corrosion resistance. STATEMENT OF SIGNIFICANCE: Nitinol is a commonly used material in the medical device industry. However, correlations between surface processing of nitinol and in-vivo corrosion has yet to be established. Elucidating the link between in-vivo corrosion and pre-clinical characterization can aid in improved prediction of clinical safety and performance of nitinol devices. We addressed this knowledge gap by fabricating nitinol stents to possess distinct surface properties and evaluating their corrosion susceptibility both in-vitro and after six months of in-vivo exposure. Relationships between stent processing, surface characterization, corrosion bench testing, and outcomes from explanted devices are discussed. These findings highlight the importance of surface characterization in nitinol devices and provide in-vitro pitting corrosion levels that can induce in-vivo corrosion in nitinol stents.


Assuntos
Ligas , Falha de Prótese , Stents/efeitos adversos , Ligas/efeitos adversos , Ligas/química , Ligas/farmacologia , Animais , Corrosão , Propriedades de Superfície , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA