Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 232
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073051

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Assuntos
Hospitalização , Alta do Paciente , Humanos , Remoção de Dispositivo , Estudos de Viabilidade , Estudos Retrospectivos , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 35(7): 1422-1428, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38751010

RESUMO

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.


Assuntos
Amiloidose , Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Ablação por Cateter/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fatores de Risco , Fatores de Tempo , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/diagnóstico por imagem , Hemorragia/induzido quimicamente , Administração Oral , Estudos Retrospectivos , Medição de Risco , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Esquema de Medicação , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico
3.
Europace ; 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39150065

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt EGM signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. STUDY AIM: If application repetition and catheter-tissue contact impact on lesion formation during PFA. METHODS: A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact-force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 hours in the vegetal model and over 6 hours in the porcine model. RESULTS: Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 mm and 4.4 ± 1.3 mm, respectively (p =0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0±0.9 mm with no contact Vs. 5.4±1.4 mm with 30 g of force; p=.0001). CONCLUSION: PFA delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA ablation are more related to PFA biophysics than mere EGM attenuation.

4.
J Cardiovasc Electrophysiol ; 34(12): 2527-2534, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37746923

RESUMO

INTRODUCTION: Earlier studies have shown a clear association between severity of human immunodeficiency virus (HIV) infection and incident atrial fibrillation (AF). We present the long-term outcome of catheter ablation (CA) and electrophysiological characteristics in HIV+ AF patients. METHODS: This study evaluated 1438 consecutive AF patients [31 (2.15%) with HIV and 1407 (97.8%) without HIV diagnosis] undergoing their first CA at our center. A total of 31 HIV patients and 31 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model. During first procedure, all received isolation of pulmonary vein (PV) + posterior wall and superior vena cava. Non-PV triggers, defined as ectopic triggers originating from sites other than PVs, were identified at the redo ablation with high-dose isoproterenol challenge. RESULTS: Clinical characteristics were not different between the groups. When compared to the control, by the end of 5 years after the first procedure, recurrence was significantly greater in HIV group [100% vs. 54%, p < .001]. Among patients that underwent redo ablation non-PV triggers were higher in HIV group [93.5% vs. 54%, p < .001], and most frequently originated from the coronary sinus [67.7% vs. 45.2%, p < .001] and left atrial appendage [41.9% vs. 25.8%, p < .001]. After focal ablation of non-PV trigger, no difference in arrhythmia recurrence between two groups [80.6% vs. 87.1%, p = .753] at 1-year follow up was found. CONCLUSION: Our findings suggest that non-PV triggers are highly prevalent in HIV+ AF patients resulting in higher rate of the mid- and long-term arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Infecções por HIV , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Infecções por HIV/complicações , Infecções por HIV/diagnóstico , Veia Cava Superior , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
5.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378783

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Prevalência , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos
6.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37477946

RESUMO

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Inteligência Artificial , Estudos de Viabilidade , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Algoritmos , Ablação por Cateter/métodos
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36942834

RESUMO

AIMS: This study aimed to examine the clinical benefits of targeted ablation of all Premature ventricular complex (PVC) morphologies vs. predominant PVC only. METHODS AND RESULTS: A total of 171 consecutive patients with reduced left ventricular ejection fraction (LVEF) and ≥2 PVC morphology with high burden (>10%/day) undergoing their first ablation procedure were included in the analysis. At the initial procedure, prevalent PVC alone was ablated in the majority. However, at the redo, all PVC morphologies were targeted for ablation. : At the first procedure, 152 (89%) patients received ablation of the dominant PVC only. In the remaining 19 (11%) patients, all PVC morphologies were ablated. At two years, high PVC burden was detected in 89 (52%) patients. Repeat procedure was performed in 78 of 89, where all PVC morphologies were ablated. At 5 years after the repeat procedure, 71 (91%) had PVC burden of <5% [3.8 ± 1.1% vs. 15.4 ± 4.3% in successful vs. failed subjects (P < 0.001)]. In patients with low PVC burden after the initial procedure, LVEF improved from 37.5% to 41.6% [mean difference (MD): 3.39 ± 2.9%, P < 0.001], whereas a reduction in LVEF from 39.8% to 34.5% (MD: 6.45 ± 4.7%, P < 0.001) was recorded in patients with high PVC burden. One year after the repeat procedure, LVEF improved from 36.2% to 41.7% (MD: 5.5 ± 4.3%, P < 0.001) in patients with successful ablation. CONCLUSION: In this observational series, ablation of all PVC morphologies was associated with significantly lower PVC burden and improvement of LVEF at long-term follow-up, compared with ablation of the dominant morphology only.


Assuntos
Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/complicações
8.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37889200

RESUMO

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Prognóstico , Resultado do Tratamento , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversos
9.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225176

RESUMO

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Transversais , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos
10.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
11.
Eur Heart J ; 43(17): 1668-1680, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35245370

RESUMO

AIMS: Mitral valve prolapse (MVP) is a common valvular heart disease with a prevalence of >2% in the general adult population. Despite this high incidence, there is a limited understanding of the molecular mechanism of this disease, and no medical therapy is available for this disease. We aimed to elucidate the genetic basis of MVP in order to better understand this complex disorder. METHODS AND RESULTS: We performed a meta-analysis of six genome-wide association studies that included 4884 cases and 434 649 controls. We identified 14 loci associated with MVP in our primary analysis and 2 additional loci associated with a subset of the samples that additionally underwent mitral valve surgery. Integration of epigenetic, transcriptional, and proteomic data identified candidate MVP genes including LMCD1, SPTBN1, LTBP2, TGFB2, NMB, and ALPK3. We created a polygenic risk score (PRS) for MVP and showed an improved MVP risk prediction beyond age, sex, and clinical risk factors. CONCLUSION: We identified 14 genetic loci that are associated with MVP. Multiple analyses identified candidate genes including two transforming growth factor-ß signalling molecules and spectrin ß. We present the first PRS for MVP that could eventually aid risk stratification of patients for MVP screening in a clinical setting. These findings advance our understanding of this common valvular heart disease and may reveal novel therapeutic targets for intervention.


Assuntos
Prolapso da Valva Mitral , Adulto , Loci Gênicos/genética , Estudo de Associação Genômica Ampla , Humanos , Proteínas de Ligação a TGF-beta Latente/genética , Prolapso da Valva Mitral/genética , Proteômica , Fatores de Risco
12.
J Cardiovasc Electrophysiol ; 33(11): 2356-2366, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35842804

RESUMO

INTRODUCTION: Increasing evidence has suggested improved outcomes in atrial fibrillation (AF) patients with heart failure (HF) undergoing catheter ablation (CA) as compared to medical therapy. We sought to investigate the benefit of CA on outcomes of patients with AF and HF as compared to medical therapy. METHODS AND RESULTS: A systematic review of PubMed, Embase, and Cochrane Central Register of Clinical Trials was performed for clinical studies evaluating the benefit of CA for patients with AF and HF. Primary endpoint was all-cause mortality. Secondary endpoints included atrial-arrhythmia recurrence and improvement in left ventricular ejection fraction (LVEF). Eight randomized controlled trials were included with a total of 2121 patients (mean age: 65 ± 5 years; 72% male). Mean follow-up duration was 32.9 ± 14.5 months. All-cause mortality in patients who underwent CA was significantly lower than in the medical treatment group (8.8% vs. 13.5%, RR 0.65, 95% confidence interval [CI] 0.51-0.83, p = .0005). A 35% relative risk reduction and 4.7% absolute risk reduction in all-cause mortality was observed with CA. Rates of all-atrial arrhythmia recurrence were significantly lower in the CA group (39.9% vs. 69.6%, RR: 0.55, 95% CI: 0.40-0.76, p = .0003). Improvement in LVEF was significantly higher in patients undergoing CA (+9.4 ± 7.6%) as compared to conventional treatment (+3.3 ± 8%) (mean difference 6.2, 95% CI: 3.6-8.8, p < .00001). CONCLUSION: CA for AF in patients with HF decreases all-cause mortality, improves all-atrial arrhythmia recurrence rate and LVEF when compared to medical management. CA should be considered the treatment of choice to improve survival in this select group of patients. Nonetheless, the benefit of CA in patients with severely reduced ejection fraction and New York Heart Association class IV HF has not been clearly elucidated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Volume Sistólico , Antiarrítmicos/efeitos adversos , Função Ventricular Esquerda , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Ablação por Cateter/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
13.
J Cardiovasc Electrophysiol ; 32(7): 1822-1832, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33844385

RESUMO

INTRODUCTION: Empirical pulmonary vein isolation (PVI) remains the cornerstone for catheter ablation of atrial fibrillation (AF). Various ablation strategies and modalities are continually tested with the aim of improving ablation outcomes. Although focal impulse and rotor modulation (FIRM)-guided ablation is currently used as an adjunct to PVI, evidence supporting this strategy is conflicting. We sought to examine whether the utilization of FIRM-guided ablation with or without PVI is associated with a decrease in all-atrial arrhythmia recurrence as compared to PVI alone. METHODS: A systematic review of PubMed, Cochrane, and Embase was performed for head-to-head study designs comparing outcomes of patients who underwent FIRM-guided ablation with or without PVI to those who underwent PVI alone. The primary efficacy endpoint was all-atrial arrhythmia recurrence. The secondary endpoints were complications rates and procedural characteristics. RESULTS: Overall, six studies comprising 674 patients undergoing either FIRM-guided ablation ± PVI versus PVI were included (mean age 63.4 ± 9.2, male 74%, 9% paroxysmal AF, 91% nonparoxysmal AF). After a mean follow-up of 18.8 months, FIRM-guided ablation with or without PVI was not associated with improvement in all-atrial arrhythmia recurrence rate compared to PVI alone (43.4% vs. 45.9%, risk ratio [RR]: 1.06; 95% confidence interval [CI]: 0.77-1.47; p = .70). No statistically significant difference was noted in complication rates between the two groups (RR: 1.66; 95% CI: 0.08-34.54; p = .74). CONCLUSION: In this meta-analysis of head-to-head comparison studies, FIRM-guided ablation with or without PVI did not provide any benefit in improving all-atrial arrhythmia recurrence at follow-up when compared to PVI alone.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 32(10): 2781-2784, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34411376

RESUMO

INTRODUCTION: Watchman FLX has been recently approved for left atrial appendage occlusion (LAAO) in the US. Intracardiac echocardiography (ICE) - which is already commonly used to guide trans-septal access - can serve as an alternative to TEE, simplifying the procedure and reducing associated costs. Herein, we report our experience with ICE-guided LAAO with Watchman FLX. METHODS AND RESULTS: This cohort study included the first 190 consecutive patients who underwent LAAO with Watchman FLX in our center. LAAO was successful in all patients without significant peri-procedural, device-related complications in either group. Compared to TEE, we observed a significant reduction in procedural times when using ICE. In addition, there was a potentially clinically relevant reduction in fluoroscopy dose, mainly secondary to fewer cine acquisition runs. At follow-up, no cases of device embolism were noted, whereas the rate of device-related thrombosis and peri-device leaks were comparable between groups. CONCLUSION: ICE-guided LAAO with Watchman FLX is safe and feasible, with a significant reduction in procedural time and potential reduction in fluoroscopy dose when compared to TEE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Estudos de Coortes , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção
15.
J Cardiovasc Electrophysiol ; 32(8): 2165-2170, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33942420

RESUMO

OBJECTIVE: To assess the safety and efficacy of a novel immunosuppressive regimen-combination Methotrexate/Prednisone (cMtx/P)-in the management of severe refractory rPPP. METHODS: In this multicenter, nonrandomized, retrospective, observational study, 408 consecutive patients diagnosed with persistent rPPP between 2017 and 19 were included. Patients with refractory symptoms despite 3 months of conventional therapy were initiated on a 4-week regimen of oral steroids. Persistence of symptoms at this point, that is, rPPP (n = 25; catheter based = 18, open surgical = 7) prompted therapy with Methotrexate (7.5-15 mg weekly) with folate supplementation along with low dose prednisone (5 mg PO) for a further 3 months. Patients were followed for a total of 11.3 ± 1.8 months. RESULTS: Treatment refractory rPPP occurred in 6.1% of the study population prompting immunosuppressive therapy with cMtx/P. All patients demonstrated complete symptom resolution following 3 months of treatment with an 85% decline in clinically significant pericardial effusions. One patient developed recurrent pericarditis during the 11-month follow-up. Therapy was well tolerated with no significant drug related adverse effects. CONCLUSION: cMtx/P therapy is a safe and effective adjunct in the management of rPPP refractory to standard therapy.


Assuntos
Imunossupressores , Pericardite , Humanos , Imunossupressores/efeitos adversos , Metotrexato/efeitos adversos , Pericardite/induzido quimicamente , Pericardite/diagnóstico , Pericardite/tratamento farmacológico , Prednisona/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 32(9): 2441-2450, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34260115

RESUMO

BACKGROUND: Atrioesophageal fistula (AEF) is a worrisome complication of atrial fibrillation (AF) ablation. Its clinical manifestations and time course are unpredictable and may contribute to diagnostic and treatment delays. We conducted a systematic review of all available cases of AEF, aiming at characterizing clinical presentation, time course, diagnostic pitfalls, and outcomes. METHODS: The digital search retrieved 150 studies containing 257 cases, 238 (92.6%) of which with a confirmed diagnosis of AEF and 19 (7.4%) of pericardioesophageal fistula. RESULTS: The median time from ablation to symptom onset was 21 days (interquartile range [IQR]: 11-28). Neurological abnormalities were documented in 75% of patients. Compared to patients seen by a specialist, those evaluated at a walk-in clinic or community hospital had a significantly greater delay between symptom onset and hospital admission (median: 2.5 day [IQR: 1-8] vs. 1 day [IQR: 1-5); p = .03). Overall, 198 patients underwent a chest scan (computed tomography [CT]: 192 patients and magnetic resonance imaging [MRI]: 6 patients), 48 (24.2%; 46 CT and 2 MRI) of whom had normal/unremarkable findings. Time from hospital admission to diagnostic confirmation was significantly longer in patients with a first normal/unremarkable chest scan (p < .001). Overall mortality rate was 59.3% and 26.0% survivors had residual neurological deficits at the time of discharge. CONCLUSIONS: Since healthcare professionals of any specialty might be involved in treating AEF patients, awareness of the clinical manifestations, diagnostic pitfalls, and time course, as well as an early contact with the treating electrophysiologist for a coordinated interdisciplinary medical effort, are pivotal to prevent diagnostic delays and reduce mortality.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fístula Esofágica/diagnóstico por imagem , Fístula Esofágica/etiologia , Fístula Esofágica/cirurgia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
17.
J Cardiovasc Electrophysiol ; 32(4): 973-981, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33442937

RESUMO

BACKGROUND: The creation of effective and permanent lesions is a crucial factor in determining the success rate of atrial fibrillation (AF) ablation. By increasing the efficacy of radiofrequency (RF) energy-mediated lesion formation, half-normal saline (HNS) as an irrigant for open-irrigated ablation catheters has the potential to reduce procedural times and improve acute and long-term outcomes. METHODS: This is a double-blind randomized clinical trial of 99 patients undergoing first-time RF catheter ablation for AF. Patients enrolled were randomly assigned in a 1:1 fashion to perform ablation using HNS or normal saline (NS) as an irrigant for the ablation catheter. RESULTS: The use of HNS is associated with shorter RF times (26 vs. 33 min; p = .02) with comparable procedure times (104 vs. 104 min). The rate of acute pulmonary vein reconnections (16% vs. 18%) was comparable, with a median of 1 vein reconnection in the HNS arm versus 2 in the NS arm. There was no difference in procedure-related complications, including the incidence of postprocedural hyponatremia when using HNS. Over the 1-year follow-up, there is no significant difference between the HNS and NS with respect to the recurrence of any atrial arrhythmia (off antiarrhythmic drugs [AAD]: 47% vs. 52%; hazard ratio [HR]: 1.17, 95% confidence interval [CI]: 0.66-2.06; off/on AAD: 66% vs. 66%, HR: 1.06, 95% CI: 0.53-2.12), with a potential benefit of using HNS when considering the paroxysmal AF cohort (on/off AAD 73% vs. 62%, HR: 0.72, 95% CI: 0.19-2.70). CONCLUSIONS: In a mixed cohort of patients undergoing first-time AF ablation, irrigation of open-irrigated RF ablation catheters with HNS is associated with shorter RF times, with a comparably low rate of procedure-related complications. In the long term, there is no significant difference with respect to the recurrence of any atrial arrhythmia. Larger studies with a more homogeneous population are necessary to determine whether HNS improves clinical outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Desenho de Equipamento , Humanos , Veias Pulmonares/cirurgia , Recidiva , Solução Salina , Resultado do Tratamento
18.
Europace ; 23(2): 226-237, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33324978

RESUMO

AIMS: Left atrial appendage electrical isolation (LAAEI) has been shown to improve freedom from all-atrial arrhythmia recurrence in patients with non-paroxysmal atrial fibrillation (AF). The aim of this study is to investigate the long-term efficacy and safety outcomes of LAAEI in patients with non-paroxysmal AF undergoing catheter ablation. METHODS AND RESULTS: A systematic review of Medline, Cochrane, and Embase was performed for clinical studies evaluating the benefit of LAAEI in non-paroxysmal AF. Nine studies with a total of 2336 patients were included (mean age: 65 ± 9 years, 63% male). All studies included patients with persistent AF, long-standing persistent AF, or both. At a mean follow-up of 40.5 months, patients who underwent LAAEI had significantly higher freedom from all-atrial arrhythmia recurrence than patients who underwent standard ablation alone [69.3% vs. 46.4%; risk ratio (RR) 0.54; 95% confidence interval (CI) 0.42-0.69; P < 0.0001]. A 46% relative risk reduction and 22.9% absolute risk reduction in atrial-arrhythmia recurrence was noted with LAAEI. Rates of cerebral thromboembolism were not significantly different between the two groups (LAAEI 3% vs. standard ablation 1.6%, respectively; RR 1.76; 95% CI 0.61-5.04; P = 0.29). Furthermore, there was no significant difference in the acute procedural complication rates between the two groups (LAAEI 4% vs. standard ablation 3%, respectively; RR 1.29; 95% CI 0.83-2.02; P = 0.26). CONCLUSION: At long-term follow-up, LAAEI led to a significantly higher improvement in freedom from all-atrial arrhythmia recurrence in patients with non-paroxysmal AF, when compared to standard ablation alone. Importantly, this benefit was achieved without an increased risk of acute procedural complications or cerebral thromboembolic events.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Tromboembolia , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
19.
Europace ; 23(1): 91-98, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33063099

RESUMO

AIMS: Radiofrequency catheter ablation (RFCA) represents an effective option for idiopathic premature ventricular contractions (PVCs) treatment. Ablation Index (AI) is a novel ablation marker incorporating RF power, contact force, and time of delivery into a single weighted formula. Data regarding AI-guided PVCs RFCA are currently lacking. Aim of the study was to compare AI-guided and standard RFCA outcomes in patients with PVCs originating from the right ventricle outflow tract (RVOT). METHODS AND RESULTS: Consecutive patients undergoing AI-guided RFCA of RVOT idiopathic PVCs were prospectively enrolled. Radiofrequency catheter ablation was performed following per-protocol target cut-offs of AI, depending on targeted area (RVOT free wall AI cut-off: 590; RVOT septum AI cut-off: 610). A multi-centre cohort of propensity-matched (age, sex, ejection fraction, and PVC site) patients undergoing standard PVCs RFCA was used as a comparator. Sixty AI-guided patients (44.2 ± 18.0 years old, 58% male, left ventricular ejection fraction 56.2 ± 3.8%) were enrolled; 34 (57%) were ablated in RVOT septum and 26 (43%) patients in the RVOT free wall area. Propensity match with 60 non-AI-guided patients was performed. Acute outcomes and complications resulted comparable. At 6 months, arrhythmic recurrence was more common in non-AI-guided patients whether in general (28% vs. 7% P = 0.003) or by ablated area (RVOT free wall: 27% vs. 4%, P = 0.06; RVOT septum 29% vs. 9% P = 0.05). Ablation Index guidance was associated with improved survival from arrhythmic recurrence [overall odds ratio 6.61 (1.95-22.35), P = 0.001; RVOT septum 5.99 (1.21-29.65), P = 0.028; RVOT free wall 11.86 (1.12-124.78), P = 0.039]. CONCLUSION: Ablation Index-guidance in idiopathic PVCs ablation was associated with better arrhythmic outcomes at 6 months of follow-up.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Adulto , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
20.
Europace ; 23(12): 1939-1949, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34417816

RESUMO

AIMS: We evaluated the efficacy of an ablation strategy empirically targeting pulmonary veins (PVs) and posterior wall (PW) and the prevalence and clinical impact of extrapulmonary trigger inducibility and ablation in a large cohort of patients with persistent atrial fibrillation (PerAF). METHODS AND RESULTS: A total of 1803 PerAF patients were prospectively enrolled. All patients underwent pulmonary vein antrum isolation (PVAI) extended to the entire PW. A standardized protocol was performed to confirm persistent PVAI and elicit any triggers originating from non-PV sites. All non-PV triggers initiating sustained atrial tachyarrhythmias were ablated. Ablation of non-PV sites triggering non-sustained runs (<30 s) of atrial tachyarrhythmias or promoting frequent premature atrial complexes (≥10/min) was left to operator's discretion. Overall, 1319 (73.2%) patients had documented triggers from non-PV areas. After 17.4 ± 8.5 months of follow-up, the cumulative freedom from atrial tachyarrhythmias among patients without inducible non-PV triggers (n = 484) was 70.2%. Patients with ablation of induced non-PV triggers had a significantly higher arrhythmia control than those whose triggers were not ablated (67.9% vs. 39.4%, respectively; P < 0.001). After adjusting for clinically relevant variables, patients in whom non-PV triggers were documented but not ablated had an increased risk of arrhythmia relapse (hazard ratio: 2.39; 95% confidence interval: 2.01-2.83; P < 0.001). CONCLUSION: Pulmonary vein antrum isolation extended to the entire PW might provide acceptable long-term arrhythmia-free survival in PerAF patients without inducible non-PV triggers. In our population of PerAF patients, non-PV triggers could be elicited in ∼70% of PerAF patients and their elimination significantly improved outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA