Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Clin Oral Investig ; 25(11): 6219-6237, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33821322

RESUMO

OBJECTIVES: This study compared the clinical performance of two bulk-fill (BF) and one conventional resin composite in a population with a high caries incidence. MATERIALS AND METHODS: A total of 138 class I and II restorations were performed and randomly divided into three groups (n = 46) with equal allocation: Filtek BF (FBF; 3M ESPE), Tetric EvoCeram BF (TBF; Ivoclar Vivadent), and control Filtek Z250 (Z250; 3M ESPE). The evaluations were performed using the USPHS and FDI criteria at baseline and after 12 and 36 months by a previously calibrated evaluator. The Friedman and Wilcoxon tests for paired data were used for statistical analysis (α = 0.05). RESULTS: The DMFT index at baseline was 9.44, with 87% from the decayed component. After 36 months, 108 restorations (n = 36) were evaluated. Two failures were observed for TBF at marginal adaptation and recurrence of caries, resulting in a survival rate of 94.44% and an annual failure rate (AFR) of 1.26%. No equivalence was observed between the criteria for surface roughness, marginal adaptation, and discoloration. CONCLUSIONS: The 36-month clinical performance of high-viscosity BF resin composites was comparable to conventional incremental-filled resin composites. The FDI criteria better presented the restorations' clinical success. However, in the case of failure, both criteria provided the same result. CLINICAL RELEVANCE: High-viscosity bulk-fill resin composites showed excellent performance after 36 months in a high caries incidence population. It can be considered a simplified alternative restoration method that reduces operating time and minimizes possible operator errors.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas , Cárie Dentária/epidemiologia , Suscetibilidade à Cárie Dentária , Humanos , Incidência , Viscosidade
2.
Gen Dent ; 63(1): e9-e11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25574734

RESUMO

This in vitro study sought to evaluate both the bleaching potential and changes to average surface roughness (Ra) of enamel after brushing with a dentifrice. Fifty-four enamel specimens (4 x 4 x 2 mm) were divided into 3 groups (n = 18) and treated with 1 of 3 dentifrices: 1 with calcium peroxide, and 2 without. The samples were submitted to 20,000 brushing cycles. Color and Ra were measured before and after brushing. Although the Ra increased in all groups after brushing, only the dentifrice containing calcium peroxide resulted in an increase in reflectance.


Assuntos
Esmalte Dentário/efeitos dos fármacos , Dentifrícios/uso terapêutico , Peróxidos/uso terapêutico , Escovação Dentária/métodos , Cor , Humanos , Técnicas In Vitro , Propriedades de Superfície/efeitos dos fármacos , Clareadores Dentários/uso terapêutico
3.
J Clin Exp Dent ; 16(2): e186-e197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38496818

RESUMO

Background: To assess whether using magnification loupes affects tooth preparation working posture performed by undergraduate students and dentistry professionals and whether it influences the quality of the preparation, operator satisfaction and procedure time. Material and Methods: This review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement and registered in the International Prospective Register of Systematic Review (CRD42023482377). Electronic searches were conducted in PubMed/Medline, Cochrane Library, Web of Science, and Scopus databases for relevant articles published up to August 2023. Clinical or laboratory studies evaluating cavities or dental preparations performed with and without magnification loupes were considered eligible. The outcomes were operator working posture, dental preparation quality, operator satisfaction, and procedure time. The quality of the studies was evaluated using the JBI Critical Appraisal tools for Quasi-Experimental Studies. Results: The searches retrieved 1493 articles. Based on the eligibility criteria, 11 laboratory studies were included, where 410 undergraduate and graduate dental students conducted dental preparations in 1851 dental specimens. Of the 11 selected studies, 6 evaluated the working posture, 6 assessed the quality of the dental preparations, 5 reported operator satisfaction, and 2 assessed procedure time. The results showed that magnifying loupes significantly improved operator working posture, but did not influence the quality of tooth preparations. Although satisfaction reports about experiences with magnifying loupes were favorable, no significant difference was found. Conclusions: Magnification loupes improved operator working posture. However, clinical studies with more scientific evidence are needed for steady conclusions regarding operator satisfaction and procedural time. Key words:Magnification, dental loupes, tooth preparation, cavity preparation, dental education.

4.
Polymers (Basel) ; 16(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38891413

RESUMO

BACKGROUND: This study investigated effects of rapid high-intensity light-curing (3 s) on increasing transdentinal temperature and cell viability. METHODS: A total of 40 dentin discs (0.5 mm) obtained from human molars were prepared, included in artificial pulp chambers (4.5 × 5 mm), and subjected to four light-curing protocols (n = 5), with a Valo Grand light curing unit: (i) 10 s protocol with a moderate intensity of 1000 mW/cm2 (Valo-10 s); (ii) 3 s protocol with a high intensity of 3200 mW/cm2 (Valo-3 s); (iii) adhesive system + Filtek Bulk-Fill Flow bulk-fill composite resin in 10 s (FBF-10 s); (iv) adhesive system + Tetric PowerFlow bulk-fill composite resin in 3 s (TPF-3 s). Transdentinal temperature changes were recorded with a type K thermocouple. Cell viability was assessed using the MTT assay. Data were analyzed using one-way ANOVA and Tukey tests for comparison between experimental groups (p < 0.05). RESULTS: The 3 s high-intensity light-curing protocol generated a higher temperature than the 10 s moderate-intensity standard (p < 0.001). The Valo-10 s and Valo-3 s groups demonstrated greater cell viability than the FBF-10s and TPF-3 s groups and statistical differences were observed between the Valo-3 s and FBF-10 s groups (p = 0.023) and Valo-3 s and TPF-3 s (p = 0.025), with a potential cytotoxic effect for the FBF-10 s and TPF-3 s groups. CONCLUSIONS: The 3 s rapid high-intensity light-curing protocol of bulk-fill composite resins caused a temperature increase greater than 10 s and showed cell viability similar to and comparable to the standard protocol.

5.
Acta Odontol Scand ; 71(1): 271-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22414046

RESUMO

OBJECTIVE: This study aimed to evaluate the push-out bond strength of dimethacrylate (Clearfil SE Bond/Filtek Z250; and Adper SE Plus/Filtek Z250) and silorane-based (Filtek P90 adhesive system/Filtek P90 composite resin) restorative systems following selective dentin pre-treatment with a CPP-ACP-containing paste (MI Paste). MATERIALS AND METHODS: Sixty bovine incisors were utilized. The buccal surface was wet-ground to obtain a flat dentin area. Standardized conical cavities were then prepared. Adhesive systems were applied according to manufacturers' directions and the composites were bulk-inserted into the cavity. The push-out bond strength test was performed at a universal testing machine (0.5 mm/min) until failure; failure modes were analyzed by scanning electron microscopy. Data were analyzed by two-way ANOVA and Tukey post-hoc test (p < 0.05). RESULTS: For Clearfil SE Bond/Filtek Z250 and Filtek P90 adhesive system/Filtek P90 composite resin, the dentin pre-treatment did not influence bond strength means. For Adper SE Plus/Filtek Z250, dentin samples treated with MI Paste had statistically higher bond strength means than non-treated specimens. Adhesive failures were more frequent. CONCLUSION: Dentin pre-treatment with the CPP-ACP containing paste did not negatively affect bond strength for Clearfil SE Bond/Filtek Z250 and Filtek P90 adhesive system/Filtek P90 composite resin restorative systems and improved bond strength for the Adper SE Plus/Filtek Z250 restorative system.


Assuntos
Cariostáticos/farmacologia , Caseínas/farmacologia , Resinas Compostas , Colagem Dentária , Preparo da Cavidade Dentária , Dentina/efeitos dos fármacos , Cimentos de Resina , Animais , Bovinos , Adaptação Marginal Dentária , Restauração Dentária Permanente , Análise do Estresse Dentário , Adesivos Dentinários , Resinas de Silorano
6.
Acta Odontol Scand ; 71(1): 215-22, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22283452

RESUMO

AIM: This study aimed to characterize the morphology of filler particles and to analyze the effect of shortened and extended photoactivation times on hardness (VHN) and cross-link density (CLD) of resin-based low-viscosity materials. METHODS: Sixteen commercially available materials were tested: four fissure sealants (Alpha Seal, Fluroshield Yellowed, Bioseal and Fluroshield White) and 12 flowable composites (Opallis T, Permaflo T, Opallis A2, Natural Flow A2, Master Flow A2, Permaflo A2, Filtek Z350 A2, Natural Flow O, Master Flow OA2, Opallis OA3.5, Filtek Z350 OA3, Opallis OP) at six curing times (10 s, 20 s, 30 s, 40 s, 50 s and 60 s). Specimens were fabricated (n = 5), analyzed by Scanning Electron Microscopy, by VHN and by CLD. RESULTS: Unimodal and multimodal filler particles sizes with spherical and irregular shapes were observed. Unfilled materials were also detected. There were no differences among curing times for either VHN or CLD. Opallis A2 and Opallis OA3.5 showed the highest VHN at all curing times, whereas Master Flow A2 and Master Flow OA2 presented the lowest VHN. Opallis A2 presented the highest CLD at all curing times and Alpha Seal showed the lowest CLD. CONCLUSIONS: Filler particle morphology differed among the resin-based low-viscosity materials tested. The shortest photoactivation time tested could yield similar VHN and CLD means to those provided by the most extended photoactivation time.


Assuntos
Resinas Compostas/química , Cura Luminosa de Adesivos Dentários , Análise de Variância , Reagentes de Ligações Cruzadas , Dureza , Teste de Materiais , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo , Viscosidade
7.
Acta Odontol Scand ; 71(3-4): 632-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22783902

RESUMO

AIM: This study aimed to evaluate the effect of pre-heated composite restoratives on the shear bond strength (SBS) of orthodontic brackets. METHODS: The following materials were tested: a microhybrid composite restorative (Filtek Z250), two nanofilled composite restoratives (Filtek Z350 and NT Premium), a nanohybrid composite restorative (Brilliant) and a conventional orthodontic adhesive (Transbond XT). All materials were stored for 1 h in the incubator either at 25°C (room temperature simulation) or 60°C before bonding 100 orthodontic brackets on bovine lower incisors (n = 10). One Coat Bond SL and Transbond XT were used to bond the composite restoratives and the Transbond XT adhesive paste, respectively. After storage in distilled water for 24 h, the brackets were subjected to SBS test at a speed of 0.5 mm/min until bracket debonding. The Adhesive Remnant Index (ARI) was assigned to the fractured specimens. Data were analyzed using the one-way ANOVA and the Tukey post-hoc test (p < 0.05). The Kruskal-Wallis test was used to compare ARI scores between the groups (p < 0.05). RESULTS: There was no statistically significant difference between the materials at room temperature. Samples bonded with pre-heated materials showed a statistically higher SBS than those bonded with room temperature materials. Samples bonded with the pre-heated orthodontic adhesive showed the highest SBS among all the pre-heated materials. All preheated composite restoratives produced an SBS mean higher than that of Transbond XT stored at room temperature. CONCLUSION: The use of pre-heated composite restoratives and orthodontic adhesives might be an alternative approach to bond orthodontic brackets.


Assuntos
Resinas Compostas , Teste de Materiais , Braquetes Ortodônticos , Animais , Bovinos
8.
Int Dent J ; 62(5): 251-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23106838

RESUMO

OBJECTIVE: This study aimed to evaluate the progression of sealed non-cavitated dentinal occlusal caries in a randomised controlled clinical trial. MATERIALS AND METHODS: Sixty teeth with non-cavitated dentinal occlusal caries were selected in patients with a high risk for caries. Patients were randomly divided into two groups so that each group included 30 teeth. Patients in the experiment group were given oral hygiene instructions and a fissure sealant. Patients in the control group were given oral hygiene instructions only. Caries progression and sealant loss were monitored over a period of 36 months by clinical and radiographic examinations. RESULTS: Clinical and radiographic progression of caries was significantly more frequent in the control group than in the experiment group. Three teeth lost their sealant and showed caries progression, but this was apparent only at the 12-month follow-up. At the 24- and 36-month recall appointments, neither sealant loss nor caries progression were observed. CONCLUSION: The pit and fissure sealant utilised in this study was shown to be effective in arresting carious lesions at 36 months.


Assuntos
Cárie Dentária/prevenção & controle , Selantes de Fossas e Fissuras , Adolescente , Criança , Falha de Restauração Dentária , Dentina , Feminino , Seguimentos , Humanos , Masculino , Higiene Bucal/educação , Resultado do Tratamento
9.
J Dent ; 117: 103918, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34879245

RESUMO

OBJECTIVES: To evaluate the effect of a glutaraldehyde-based desensitizer on the postoperative sensitivity (POS) in posterior resin composite restorations up to 12 months using a universal adhesive (Tetric N-Bond Universal) with selective enamel etching (SE) or an etch-and-rinse (ER) strategy. METHODS: Class I and class II resin composite restorations (n = 220) at least 3 mm deep were inserted in 55 subjects. The universal adhesive was applied using the SE (self-etch strategy on dentin with selective enamel etching) or the ER strategy, with or without prior application of a glutaraldehyde-based desensitizer (Gluma Desensitizer - GL) to form groups SEGL and ERGL. A bulk-fill resin composite (Tetric NCeram Bulk Fill) was used for all restorations. Spontaneous POS was assessed 7 days after the restorative procedure using the Visual Analog Scale (VAS) and the Numeric Rating Scale (NRS). After 7, 14, and 30 days of completing each restoration, the subjects were reassessed to evaluate POS caused by stimulation with an air blast, horizontal and vertical percussion. In addition, marginal discoloration, marginal adaptation, fracture, and recurrence of caries were evaluated using the FDI (World Dental Federation) criteria after 7 days and at 12 months. RESULTS: No significant spontaneous or stimuli-induced POS was observed when restorations with or without GL were compared (p>0.05). A higher risk of spontaneous POS was observed within 7 days (40.0%; 95% CI 28.1 to 53.1), without statistically significant differences among groups. None of the participants reported POS at 12 months, however five restorations were considered clinically unsatisfactory (p > 0.05). CONCLUSIONS: The previous application of GL did not significantly reduce spontaneous or stimuli-induced POS in posterior resin composite restorations at any time, regardless of the adhesive strategy used. CLINICAL SIGNIFICANCE: The use of a glutaraldehyde-based desensitizing agent did not generate lower incidence of postoperative sensitivity in resin composite posterior restorations.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Cárie Dentária/prevenção & controle , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Adesivos Dentinários , Glutaral/farmacologia , Glutaral/uso terapêutico , Humanos , Cimentos de Resina/uso terapêutico
10.
Eur J Dent ; 15(2): 179-192, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33242913

RESUMO

OBJECTIVE: This study was aimed to compare the 12-month clinical performance of two full-body bulk-fill resin composites Filtek bulk fill/3M ESPE (FBF) and Tetric EvoCeram bulk fill/Ivoclar Vivadent (TBF) and a conventional microhybrid resin composite Filtek Z250/3M ESPE (Z250) using the modified the United States Public Health Service (USPHS) and Federation Dentaire Internationale (FDI) criteria. Also, the agreement between the two evaluation criteria was evaluated at baseline and after 12 months of follow-up. MATERIALS AND METHODS: A total of 138 class I and II restorations were placed in posterior teeth (split-mouth design) of 46 volunteers following manufacturer's instructions and bonded with a self-etching bonding agent (Clear fill SE Bond/Kuraray). The restorations were evaluated at baseline and after 12 months of follow-up by three previously calibrated dentists (Cohen's K = 0.84). STATISTICAL ANALYSIS: Fisher's exact test and Pearson's Chi-squared test were used to evaluating the homogeneity of distribution of the clinical characteristics. Friedman's test was applied to evaluate differences among the resin composites. The results obtained for the USPHS and FDI criteria at the different observation times were compared using the Wilcoxon test. A level of significance of 0.05 was adopted for all tests. RESULTS: After 12 months (recall rate, 78.3%, n = 36 patients), the overall success rate was 99.07% for both criteria. Only one failed restoration (0.93%) was detected for each system during follow-up in the TBF group. CONCLUSION: The bulk-fill resin composites showed satisfactory clinical performance compared with conventional resin composite after 12 months. The percentage of the acceptable scores was significantly higher for the USPHS criteria, due to discrepancies in the score description for each criterion.

11.
Braz Oral Res ; 32: e31, 2018 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-29898018

RESUMO

Polymethyl methacrylate (PMMA) has been considered a suitable material for cranioplasty. However, no consensus has been reached concerning the best material for cranioplasty with regard to minimizing complications. Thus, this systematic review and meta-analysis aimed to compare the complication rates of PMMA with those of autologous bone and titanium mesh. This review was registered with PROSPERO (CRD42016042725). Systematic searches were conducted on PubMed/MEDLINE, Scopus, and Web of Science. The focus question was, "Do PMMA prostheses used in cranioplasty have complications rates similar to those of autologous bone and titanium mesh?" A meta-analysis of complication rates was performed on the basis of dichotomous outcomes assessed by risk ratio (RR) with corresponding 95% confidence intervals (CI). From 1014 data sources, 11 articles were selected according to eligibility criteria. These articles involved 1,256 individuals and 1,278 cranioplasties using autologous bone (n = 408), PMMA (n = 379), or titanium (n = 151). The follow-up period ranged from 63 days to 54.3 months. No difference was observed between the complication rates of PMMA and autologous bone (p = 0.94; RR, 0.98; 95%CI, 0.54-1.75) or between PMMA and titanium (p = 0.38; RR, 1.59; 95%CI, 0.57-4.48). Sub-analysis of the reasons for craniotomy (trauma/non-trauma) was conducted, which revealed no significant difference (p = 0.91; RR, 0.95; 95%CI, 0.37-2.42). The meta-analysis indicated that the use of PMMA yields complication rates that are near those of autologous bone and titanium mesh.


Assuntos
Substitutos Ósseos/efeitos adversos , Transplante Ósseo/efeitos adversos , Procedimentos de Cirurgia Plástica/efeitos adversos , Polimetil Metacrilato/efeitos adversos , Crânio/cirurgia , Resinas Acrílicas/efeitos adversos , Materiais Biocompatíveis , Humanos , Fatores de Risco , Titânio/efeitos adversos , Transplante Autólogo/efeitos adversos
12.
J Dent ; 34(1): 52-61, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15922502

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the tensile bond strength (TBS) of Panavia F resin cement (PF) applied on dentine pre-treated with ED Primer (ED) and Clearfil Liner Bond 2V (CLB) coated with a layer of low-viscosity composite Protect Liner F (PLF) at 10 min, 24 h and 12 months after curing. METHODS: The labial surfaces of 60 bovine lower incisors were ground to obtain a flat dentine surface, allowing a demarcation of a 4.0 mm-diameter area with adhesive tape. The teeth were randomly divided in six groups; ED was applied in groups A I, A II and A III and CLB was applied, followed by PLF, in groups B I, B II and B III. A resin composite rod with a wire loop was luted directly to the prepared surface of each group with PF. The specimens of groups A I and B I were submitted to TBS test after 10 min. Groups A II and B II were submitted to TBS test after 24 h storage and groups A III and B III were submitted to TBS test after 12 months storage. Each specimen was inspected by SEM and classified according to the failure mode. Additionally, two representative specimens of each failure mode were sectioned for a composite/dentine interface SEM evaluation. RESULTS: No significant statistical differences were observed among the groups at 10 min and 24 h. Groups A III and B III presented the lowest TBS values (p<0.05) after 12 months storage. PF on resin-coated dentin (PLF) showed the highest TBS values and was statistically different to PF on dentine for all the groups. The fracture pattern was generally cohesive on the adhesive/hybrid layer for groups A I, A II and A III and cohesive on composite resin for B I, B II and B III. SIGNIFICANCE: The use of a less hydrophilic self-etching system to pre-treat dentine, coating with a low-viscosity composite layer prior luting with resin cement, may provide a protection of the hybridised complex, allowing a dentine seal during the 12 months storage period.


Assuntos
Resinas Acrílicas/química , Resinas Compostas/química , Colagem Dentária/métodos , Poliuretanos/química , Cimentos de Resina/química , Animais , Bovinos , Dentina/química , Adesivos Dentinários/química , Estabilidade de Medicamentos , Resistência à Tração , Fatores de Tempo
13.
Acta Biomater Odontol Scand ; 2(1): 79-85, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28642915

RESUMO

Objective: The aim of the present study was to compare the effect of pre-treating dentin with chlorhexidine, at concentrations of 0.2% and 2%, and remineralizing paste containing CPP-ACP (MI Paste - GC) on the bond strength of adhesive systems. Material and methods: In total, 80 slides of dentin were used. These slides were 2 mm thick and were obtained from bovine incisors. Standard cavities were created using diamond bur number 3131. In the control groups, a Scotchbond Universal Adhesive (SUA) self-etching adhesive system of 3M ESPE and a Clearfil SE Bond (CSE) adhesive system of Kuraray were applied, following the manufacturer's instructions. In the other groups, dentin was pretreated with chlorhexidine (0.2% and 2%) for 1 min and with MI Paste for 3 min. The cavities were restored with Z350 XT resin (3M ESPE). After 24 h of storage, the push-out test was applied at a speed of 0.5 mm/min. Results: The different dentin pretreatment techniques did not affect the intra-adhesive bond strength. There was a difference between treatment with MI Paste and chlorhexidine 0.2% in favor of the SUA, with values of 15.22 and 20.25 Mpa, respectively. Conclusions: The different pretreatment methods did not alter the immediate bond strength to dentin. Differences were only recorded when comparing the adhesives.

14.
J Dent ; 33(2): 155-62, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15683897

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the biocompatibility of the most used bleaching materials for pulpless teeth, sodium perborate and 30% hydrogen peroxide, in an experimental model of macrophages, through analysis of the adherence index and the cellular morphology. METHODS: Inflammatory macrophages were obtained from peritoneal washed of Wistar rats. The evaluation of the adherence capacity of these cells to the plastic surface was conducted in Eppendorf tubes containing RPMI, after treatment with the bleaching agents diluted in 1:10, 1:100 and 1:1000 for 15 and 30 min, and incubation at 37 degrees C and humidified atmosphere of 5% CO(2) in air. The cellular morphology was verified after incubation of the cells treated with the bleaching agents in culture plaques and compared with normal cells in culture medium. RESULTS: Results showed that sodium perborate neither increased the adherence index, nor altered the cellular morphology when compared to the control group. The distribution, cellular morphology, cytoplasmatic and nuclear characteristics, reproduced the aspects observed in normal macrophages. However, the treatment with 30% hydrogen peroxide presented an increase in adherence index when compared to the control group (RPMI), in all dilutions, according to Mann-Whitney test (n=08 and p=0.001 for dilutions 1:10 and 1:100, and n=08 and p=0.004 for dilution 1:1000). The morphology of the cells treated with this product presented structural alterations proportionally greater, depending on the dilution of this bleaching agent, and even in the highest dilution (1:1000) the cells presented very evident alterations. CONCLUSIONS: This irreversible cellular damage as well as the elevation of the adherence index, characterizes the aggressive potential of 30% hydrogen peroxide, regardless of its dilution. Sodium perborate, on the other hand, showed biocompatibitity, since, no morphological nor functional alteration was observed in macrophages.


Assuntos
Materiais Biocompatíveis/farmacologia , Boratos/farmacologia , Peróxido de Hidrogênio/farmacologia , Macrófagos Peritoneais/efeitos dos fármacos , Oxidantes/farmacologia , Clareamento Dental , Animais , Materiais Biocompatíveis/administração & dosagem , Boratos/administração & dosagem , Adesão Celular/efeitos dos fármacos , Núcleo Celular/efeitos dos fármacos , Células Cultivadas , Citoplasma/efeitos dos fármacos , Relação Dose-Resposta a Droga , Peróxido de Hidrogênio/administração & dosagem , Macrófagos Peritoneais/citologia , Masculino , Oxidantes/administração & dosagem , Ratos , Ratos Wistar
15.
Oper Dent ; 30(2): 201-12, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15853106

RESUMO

This in vitro study morphologically evaluated the effect of some current surface pre-treatments on dentin, using scanning electron microscopy, and related these morphological alterations to clinical implications. The labial surfaces of 30 bovine lower incisors were ground to obtain a flat dentin surface and were finished with 600-grit SiC paper to produce standardized smear layers. The teeth were randomly divided into six groups of five each. Group 1 was the control group, smear layer covered dentin; Group 2 was etched with 37% phosphoric acid (PA) for 15 seconds; Group 3, 37% PA for 15 seconds, followed by 10% NaOCl for 60 seconds; Group 4, 10% NaOCl for 60 seconds; Group 5, a self-etching primer (Clearfil SE Bond, CSEB-primer) was applied for 20 seconds; Group 6, CSEB-primer for 20 seconds, followed by NaOCl for 60 seconds. The specimens were fixed, dehydrated, dried and analyzed by SEM. Treatment with 37% PA removed the smear layer, funneled the tubules and resulted in a collagen-rich surface which appeared to have collapsed in its outermost part, producing a dense surface layer covered with silica particles. When 37% PA treatment was followed by 10% NaOCl, the collagen network was removed to reveal an eroded, rough mineral surface with numerous lateral branches and larger than normal tubular orifices. The action of 10% NaOCl on the smear layer-covered dentin showed no significant alteration in surface morphology. The treatment with CSEB-primer dissolved the smear layer but only partially dissolved the smear plugs. The tubules did not present the typical funnel shape seen following PA treatment. These morphological aspects on dentin surface must influence bonding results. The dentin surface alterations produced by PA appeared to be a very severe demineralization pattern, quite irregular and less permeable to monomer infiltration, while the surface provided by the self-etching primer appeared to be a more uniform, less porous surface, and the association with simultaneous monomer infiltration may reduce the occurrence of mistakes in clinical bonding procedures.


Assuntos
Condicionamento Ácido do Dente/métodos , Dentina/ultraestrutura , Animais , Compostos Inorgânicos de Carbono/química , Bovinos , Colágeno/ultraestrutura , Solubilidade da Dentina , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos/química , Porosidade , Distribuição Aleatória , Cimentos de Resina/química , Compostos de Silício/química , Dióxido de Silício/química , Camada de Esfregaço , Hipoclorito de Sódio/química , Fatores de Tempo
16.
J Dent ; 32(5): 391-8, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15193788

RESUMO

OBJECTIVES: The aim of this study was to evaluate nanoleakage patterns following silver methenamine staining of restorations bonded with a total-etch single bottle system, a self-etching primer system and a total-etch single bottle system after collagen depletion. METHODS: The dentin bonding systems used in this study were Prime and bond 2.1 (PB) and Clearfil SE Bond (CSEB). Cavities were made in grounded labial surfaces of 15 extracted bovine lower incisors, randomly divided into 3 Groups. Group 1 (PB), Group 2 (CSEB) and Group 3 (PB/SH) PB after collagen depletion with sodium hypochlorite (SH). The specimens were restored, sectioned and submitted to silver methenamine staining, polished and observed with low-vacuum back-scattered SEM. One way ANOVA and multiple-comparison Tukey's test were used for statistical analysis of the leakage scores. RESULTS: PB presented significantly greater silver deposition and a distinct pattern when compared to CSEB. No silver deposition was detected for PB after collagen depletion. SIGNIFICANCE: The dentine bonding systems tested were unable to prevent nanoleakage when used according to the manufacturers' instructions; however, CSEB presented a lower level of silver deposition. Collagen depletion prior to PB application may prevent nanoleakage occurrence in dentine walls. Silver methenamine staining may be a useful method for detection of nanoleakage in dentine when the collagen fibrils remain exposed within the hybrid layers.


Assuntos
Corantes , Infiltração Dentária/diagnóstico , Metenamina , Cimentos de Resina/química , Acetona/química , Condicionamento Ácido do Dente , Análise de Variância , Animais , Bovinos , Colágeno/química , Restauração Dentária Permanente , Dentina/ultraestrutura , Teste de Materiais , Microscopia Eletrônica de Varredura , Nanotecnologia , Oxidantes/química , Ácidos Polimetacrílicos/química , Distribuição Aleatória , Hipoclorito de Sódio/química , Propriedades de Superfície
17.
Oper Dent ; 28(4): 378-87, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12877423

RESUMO

This study evaluated the influence of collagen removal and the use of a low-viscosity liner on the marginal quality of composite restorations for the total-etch system, Prime & Bond 2.1 (PB) and the self-etching primer system, Clearfil SE Bond (CSEB), in high C-factor cavities with margins in dentin. High C-factor cavities were made on dentin exposed from ground labial surfaces of 100 bovine lower incisors, randomly assigned to 10 treatment groups and restored with composite Z 250, placed in bulk. In Group 1 (PB), control group, PB was applied according to the manufacturer's directions; in Group 2 (PB/PLF), an intermediate layer of low-viscosity composite Protect Liner F (PLF) was applied on the bonding resin surface; in Group 3 (PB/SH) following acid-etching, the surfaces were treated with 10% sodium hypochlorite (SH) for one minute and in Group 4 (PB/SH/PLF), the same procedure was conducted as for Group 3, plus an intermediate layer of PLF was applied as for Group 2. In Group 5 (CSEB), the control group, CSEB was applied according to the manufacturer's directions; in Group 6 (CSEB/PLF), an intermediate layer of PLF was applied; in Group 7 (SH/CSEB), the cavity surface was pre-treated with SH; in Group 8 (SH/CSEB/PLF), SH pre-treatment was conducted as for Group 7, then an intermediate layer of PLF was applied; in Group 9 (CSEB/SH), after CSEB-primer application, the surface was treated with SH, followed by CSEB-adhesive application and in Group 10 (CSEB/SH/PLF), the same was conducted as for Group 9, then an intermediate layer of PLF was applied. The specimens were stored at 37 degrees C for 24 hours, polished, molded and replicas were obtained in epoxy resin. The replicas were gold-sputter coated and observed by SEM (300x) for marginal quality classification. The Kruskal-Wallis non-parametrical multi-comparison Test (p<0.05) was used to obtain statistical analysis of the data. Results demonstrated that both adhesive systems in the control groups presented low marginal quality and a high variability. The use of an intermediate layer of PLF significantly improved the marginal quality with the CSEB system but had no effect with the PB system. Collagen depletion with SH enhanced marginal quality for the PB system and did not influence the CSEB system results.


Assuntos
Condicionamento Ácido do Dente , Colágeno/efeitos dos fármacos , Resinas Compostas , Forramento da Cavidade Dentária , Adaptação Marginal Dentária , Acetona , Animais , Bovinos , Dentina/química , Permeabilidade da Dentina , Adesivos Dentinários , Microscopia Eletrônica de Varredura , Ácidos Polimetacrílicos , Cimentos de Resina , Hipoclorito de Sódio/farmacologia , Viscosidade
18.
Braz. oral res. (Online) ; 32: e31, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-952157

RESUMO

Abstract Polymethyl methacrylate (PMMA) has been considered a suitable material for cranioplasty. However, no consensus has been reached concerning the best material for cranioplasty with regard to minimizing complications. Thus, this systematic review and meta-analysis aimed to compare the complication rates of PMMA with those of autologous bone and titanium mesh. This review was registered with PROSPERO (CRD42016042725). Systematic searches were conducted on PubMed/MEDLINE, Scopus, and Web of Science. The focus question was, "Do PMMA prostheses used in cranioplasty have complications rates similar to those of autologous bone and titanium mesh?" A meta-analysis of complication rates was performed on the basis of dichotomous outcomes assessed by risk ratio (RR) with corresponding 95% confidence intervals (CI). From 1014 data sources, 11 articles were selected according to eligibility criteria. These articles involved 1,256 individuals and 1,278 cranioplasties using autologous bone (n = 408), PMMA (n = 379), or titanium (n = 151). The follow-up period ranged from 63 days to 54.3 months. No difference was observed between the complication rates of PMMA and autologous bone (p = 0.94; RR, 0.98; 95%CI, 0.54-1.75) or between PMMA and titanium (p = 0.38; RR, 1.59; 95%CI, 0.57-4.48). Sub-analysis of the reasons for craniotomy (trauma/non-trauma) was conducted, which revealed no significant difference (p = 0.91; RR, 0.95; 95%CI, 0.37-2.42). The meta-analysis indicated that the use of PMMA yields complication rates that are near those of autologous bone and titanium mesh.


Assuntos
Humanos , Crânio/cirurgia , Transplante Ósseo/efeitos adversos , Substitutos Ósseos/efeitos adversos , Polimetil Metacrilato/efeitos adversos , Procedimentos de Cirurgia Plástica/efeitos adversos , Titânio/efeitos adversos , Transplante Autólogo/efeitos adversos , Materiais Biocompatíveis , Resinas Acrílicas/efeitos adversos , Fatores de Risco
19.
Braz Dent J ; 23(5): 477-83, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23306221

RESUMO

This study evaluated the impact of extended etching and bonding strategies on the microshear bond strength of three sealant materials. Two pit-and-fissure sealants [FluroShield, Dentsply (light-cured) and AlphaSeal, DFL (self-cured)] and one light-cured flowable composite resin (Permaflo, Ultradent) were evaluated according to different enamel etching times (15 s or 30 s) and bonding procedures (no adhesive application, application of primer/hydrophobic resin or hydrophobic resin only). Intact enamel blocks were obtained from bovine teeth and sealed via the tested protocols. After 24 h, the microshear bond strength test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were classified by stereomicroscopy. Data were submitted to a three-way ANOVA and to Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) among the materials. Permaflo showed higher bond strength when etched for 30 s alone. Enamel overetching decreased the bond strength of the light-cured sealant. Primer/bond previous treatment improved bond performance for AlphaSeal. In conclusion, from the tested conditions, all sealant materials presented similar bond strength values in relation to bonding protocol and etching time. The flowable composite can be used as a pit-and-fissure sealant. The use of a three-step adhesive system was essential for the self-cured sealant application.


Assuntos
Resinas Compostas/química , Colagem Dentária/métodos , Esmalte Dentário/química , Corrosão Dentária/métodos , Adesivos Dentinários/química , Selantes de Fossas e Fissuras/química , Análise de Variância , Animais , Bovinos , Análise do Estresse Dentário , Análise de Falha de Equipamento/métodos , Cura Luminosa de Adesivos Dentários , Resistência ao Cisalhamento
20.
Microsc Res Tech ; 75(11): 1571-5, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22807152

RESUMO

Although in-office bleaching has been proven successful for bleaching teeth, controversy exists from morphological alterations in enamel morphology due to mineral loss and tooth sensitivity. This preliminary study aimed to evaluate the efficacy of a novel in-office tooth bleaching technique modified with a casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) paste (MI paste-MI) and its effect on the enamel morphology and tooth sensitivity. Three patients received a 35% hydrogen peroxide (Whiteness HP-HP) dental bleaching system. HP was prepared and applied on the teeth on one of the hemiarches, whilst teeth on the other hemiarch were bleached with a mixture of HP and MI. Tooth color, epoxy resin replicas, and sensitivity levels were evaluated in the upper incisors. The results were analyzed descriptively. Right and left incisors showed similar color change after bleaching. Incisors bleached with the mixture of HP and MI presented unaltered enamel surfaces and lower sensitivity levels. The currently tested tooth bleaching technique did not reduce the gel effectiveness while decreasing hypersensitivity levels and protecting the enamel against surface alterations caused by the high-concentration bleaching peroxide tested. The concomitant use of MI Paste and high-concentration hydrogen peroxide might be a successful method for decreasing tooth sensitivity and limiting changes in the enamel morphology during in-office bleaching.


Assuntos
Fosfatos de Cálcio/administração & dosagem , Caseínas/administração & dosagem , Peróxido de Hidrogênio/administração & dosagem , Fosfopeptídeos/administração & dosagem , Clareadores Dentários/administração & dosagem , Clareamento Dental/métodos , Fosfatos de Cálcio/efeitos adversos , Caseínas/efeitos adversos , Cor , Esmalte Dentário/efeitos dos fármacos , Sensibilidade da Dentina/induzido quimicamente , Humanos , Peróxido de Hidrogênio/efeitos adversos , Fosfopeptídeos/efeitos adversos , Clareadores Dentários/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA