Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Sensors (Basel) ; 21(10)2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-34066113

RESUMO

In this work, we propose and analyze a new concept of gamma ray imaging that corresponds to a gamma camera with a mobile collimator, which can be used in vivo, during surgical interventions for oncological patients for localizing regions of interest such as tumors or ganglia. The benefits are a much higher sensitivity, better image quality and, consequently, a dose reduction for the patient and medical staff. This novel approach is a practical solution to the overlapping problem which is inherent to multi-pinhole gamma camera imaging and single photon emission computed tomography and which translates into artifacts and/or image truncation in the final reconstructed image. The key concept consists in introducing a relative motion between the collimator and the detector. Moreover, this design could also be incorporated into most commercially available gamma camera devices, without any excessive additional requirements. We use Monte Carlo simulations to assess the feasibility of such a device, analyze three possible designs and compare their sensitivity, resolution and uniformity. We propose a final design of a gamma camera with a high sensitivity ranging from 0.001 to 0.006 cps/Bq, and a high resolution of 0.5-1.0 cm (FWHM), for source-to-detector distances of 4-10 cm. Additionally, this planar gamma camera provides information about the depth of source (with approximate resolution of 1.5 cm) and excellent image uniformity.


Assuntos
Câmaras gama , Tomografia Computadorizada de Emissão de Fóton Único , Artefatos , Estudos de Viabilidade , Humanos , Método de Monte Carlo , Imagens de Fantasmas
2.
Audiol Neurootol ; 20 Suppl 1: 60-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25997672

RESUMO

Tinnitus is an incapacitating condition commonly affecting cochlear implant (CI) candidates. The aim of this clinical study is to assess the long-term effects of CI treatment in patients with severe-to-profound, sensorineural, unilateral hearing loss (UHL) and incapacitating tinnitus. We performed a prospective Cochlear™ company-sponsored multicentre study in five Spanish centres. Sixteen patients with UHL and incapacitating tinnitus, which was indicated by a Tinnitus Handicap Inventory (THI) score >58%, received a Nucleus® CI in their deaf ear. The study design includes repeated within-subject measures on hearing, tinnitus, hyperacusis and quality of life up to 12 months after initial CI fitting. In addition to hearing loss and tinnitus, all patients suffered from hyperacusis. Most patients had a sudden hearing loss and received a CI within 2 years after their hearing loss. Preliminary 6-month, post-CI activation data of 13 subjects showed that the majority of patients perceived a subjective benefit from CI treatment, which was assessed using the THI, a Visual Analogue Scale of tinnitus loudness/annoyance and the Speech, Spatial and Qualities of Hearing Scale. Preliminary 12-month data of 7 subjects showed that most patients also perceived a degree of relief from their hyperacusis. One patient showed no improvements in any of the applied scales, which could be explained by partial insertion of the electrode due to obstruction of the cochlea by otosclerosis. In conclusion, CI can successfully be used in the treatment of UHL patients with accompanying severe tinnitus and hyperacusis. Implantation resulted in hearing benefits and a durable relief from tinnitus and hyperacusis in the majority of patients. These findings support the hypothesis that pathophysiological mechanisms after peripheral sensorineural hearing loss are at least partly reversible when hearing is restored with a CI.


Assuntos
Implante Coclear , Perda Auditiva Neurossensorial/reabilitação , Perda Auditiva Unilateral/reabilitação , Hiperacusia/reabilitação , Zumbido/reabilitação , Adulto , Idoso , Implantes Cocleares , Feminino , Perda Auditiva Neurossensorial/complicações , Perda Auditiva Súbita/complicações , Perda Auditiva Súbita/reabilitação , Perda Auditiva Unilateral/complicações , Humanos , Hiperacusia/complicações , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Zumbido/complicações , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-36906066

RESUMO

At this time, we still do not have adequate knowledge and awareness of the consequences of hearing loss in the elderly on quality of life. Similarly, there is also insufficient information on the relationship of presbycusis and balance disorders with other comorbidities. Such knowledge can contribute to improve both prevention and treatment of these pathologies, to reduce their impact on other areas such as cognition or autonomy, as well as to have more accurate information on the economic impact they generate in society and in the health system. Therefore, with this review article we aim to update the information on the type of hearing loss and balance disorders in people over 55 years of age, and their associated factors; to analyze the impact on the quality of life of these people and the one which can be generated at a personal and population level (both sociological and economic) if an early intervention in these patients is pursued.


Assuntos
Surdez , Presbiacusia , Humanos , Idoso , Presbiacusia/terapia , Presbiacusia/epidemiologia , Qualidade de Vida , Cognição
4.
Artigo em Inglês | MEDLINE | ID: mdl-21997337

RESUMO

CONCLUSION: This study demonstrates that electric-acoustic stimulation (EAS) significantly decreases the subjective impairment in speech perception. OBJECTIVES: To assess the subjective benefit of EAS over the first 12 months after EAS fitting using the Abbreviated Profile of Hearing Aid Benefit (APHAB). METHOD: Twenty-three EAS users, implanted with either the PULSAR(CI)(100) FLEX(EAS) provided with the DUET EAS processor or the COMBI40+ Medium provided with the TEMPO+ speech processor, were included. Electric stimulation was activated about 1 month postoperatively; ipsilateral acoustic stimulation was added 2 months thereafter. EAS benefit was measured preoperatively with only a hearing aid and postoperatively at EAS fitting and then 3, 6 and 12 months after EAS fitting using the APHAB. RESULTS: Subjects reported significant improvements in the global score with a mean decrease in impairment from 74% preoperatively to 45% after 3 months of EAS use. Furthermore, clinical relevance was demonstrated in multiple subscales between preoperative and first fitting reflecting a true benefit of EAS with a probability of 95%.


Assuntos
Estimulação Acústica/métodos , Implante Coclear/reabilitação , Estimulação Elétrica/métodos , Auxiliares de Audição , Perda Auditiva Bilateral/reabilitação , Percepção da Fala , Adulto , Idoso , Limiar Auditivo , Implante Coclear/psicologia , Terapia Combinada , Feminino , Audição , Perda Auditiva Bilateral/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Percepção da Altura Sonora , Psicoacústica , Inquéritos e Questionários , Adulto Jovem
5.
Int J Audiol ; 49(9): 657-66, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20583945

RESUMO

Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rates tended to give lower scores. However, there were no significant differences between the word scores across subjects if collected at the individually preferred pulse rate. High pulse rates were preferred when the post-implantation threshold was low.


Assuntos
Percepção Auditiva , Implantes Cocleares , Correção de Deficiência Auditiva , Perda Auditiva Neurossensorial/reabilitação , Pessoas com Deficiência Auditiva/reabilitação , Processamento de Sinais Assistido por Computador , Percepção da Fala , Estimulação Acústica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria da Fala , Limiar Auditivo , Estimulação Elétrica , Europa (Continente) , Perda Auditiva Neurossensorial/psicologia , Humanos , Percepção Sonora , Pessoa de Meia-Idade , Pessoas com Deficiência Auditiva/psicologia , Desenho de Prótese , Ajuste de Prótese , Índice de Gravidade de Doença , Adulto Jovem
6.
Hum Mutat ; 29(6): 823-31, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18381613

RESUMO

Autosomal recessive nonsyndromic hearing impairment (NSHI) is a heterogeneous condition, for which 53 genetic loci have been reported, and 29 genes have been identified to date. One of these, OTOF, encodes otoferlin, a membrane-anchored calcium-binding protein that plays a role in the exocytosis of synaptic vesicles at the auditory inner hair cell ribbon synapse. We have investigated the prevalence and spectrum of deafness-causing mutations in the OTOF gene. Cohorts of 708 Spanish, 83 Colombian, and 30 Argentinean unrelated subjects with autosomal recessive NSHI were screened for the common p.Gln829X mutation. In compound heterozygotes, the second mutant allele was identified by DNA sequencing. In total, 23 Spanish, two Colombian and two Argentinean subjects were shown to carry two mutant alleles of OTOF. Of these, one Colombian and 13 Spanish subjects presented with auditory neuropathy. In addition, a cohort of 20 unrelated subjects with a diagnosis of auditory neuropathy, from several countries, was screened for mutations in OTOF by DNA sequencing. A total of 11 of these subjects were shown to carry two mutant alleles of OTOF. In total, 18 pathogenic and four neutral novel alleles of the OTOF gene were identified. Haplotype analysis for markers close to OTOF suggests a common founder for the novel c.2905_2923delinsCTCCGAGCGCA mutation, frequently found in Argentina. Our results confirm that mutation of the OTOF gene correlates with a phenotype of prelingual, profound NSHI, and indicate that OTOF mutations are a major cause of inherited auditory neuropathy.


Assuntos
Perda Auditiva Neurossensorial/genética , Proteínas de Membrana/genética , Argentina , Colômbia , Feminino , Genes Recessivos , Humanos , Masculino , Mutação , Espanha
7.
Acta Otolaryngol ; 128(9): 968-75, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19086194

RESUMO

CONCLUSION: A high rate of hearing preservation during cochlear implantation for electric acoustic stimulation (EAS) is possible, even when surgery is conducted by a number of different surgeons. OBJECTIVES: This study aimed to determine the degree of hearing preservation using surgery for EAS in a European multi-centre clinical investigation. It also aimed to demonstrate the effect of EAS in individuals with residual low frequency hearing, both on speech perception and on subjective quality of life measures. PATIENTS AND METHODS: Eighteen patients with profound high frequency hearing loss were recruited in five participating European centres. Subjects were assessed based on an audiologic test battery, as well as on a subjective hearing aid benefit questionnaire. Each subject underwent attempted hearing preservation cochlear implantation using the MED-EL C40 + device with a Medium electrode. Residual ipsilateral hearing and speech discrimination abilities were assessed at defined intervals up to 12 months after the combined electric-acoustic mode was introduced. RESULTS: Results showed that some degree of hearing preservation was possible in 15718 patients. All subjects showed statistically significant benefit on all three speech perception tests over time. These significant benefits were also reflected in the subjective benefit outcomes.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva Neurossensorial/terapia , Adulto , Idoso , Audiometria , Desenho de Equipamento , Europa (Continente) , Feminino , Seguimentos , Perda Auditiva Neurossensorial/etiologia , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Percepção da Fala , Resultado do Tratamento
8.
Acta Otorrinolaringol Esp ; 59(2): 76-9, 2008 Feb.
Artigo em Espanhol | MEDLINE | ID: mdl-18341864

RESUMO

There are many different vertigo classifications and different denominations are frequently used for the same clinical processes. The Otoneurology Committee of the Spanish Society for Otorhinolaryngology and Head and Neck Pathology proposes an eminently practical classification of peripheral vertigo to facilitate a common terminology that can be easily used by the general ENT practitioners. The methodology used has been by consensus within our Society and especially among the most outstanding work groups in the area of otoneurology in Spain. Initially vertigo is divided into single-episode vertigo and recurring attacks of vertigo, and these are then sub-divided into 2 groups, depending on whether or not hearing loss is present. Acute vertigo without hearing loss corresponds to vestibular neuritis and if it is associated with hearing loss, it is due to labyrinthitis of different aetiologies and cochleo-vestibular neuritis. Recurrent vertigos without hearing loss are classified as induced, either by posture (BPPV) or pressure (perilymphatic fistula), or as spontaneous, including migraine-associated vertigo, metabolic vertigo, childhood paroxysmal vertigo and vertigo of vascular causes (AITs, vertebral-basilar failure). Finally, recurrent vertigo with hearing loss includes Ménière's disease and others such as vertigo-migraine (with hearing loss), autoimmune pathology of the inner ear, syphilitic infection, and perilymphatic fistula (with hearing loss).


Assuntos
Neurologia/métodos , Otolaringologia/métodos , Sociedades Médicas , Vertigem/diagnóstico , Vertigem/fisiopatologia , Humanos , Espanha
9.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28859992

RESUMO

INTRODUCTION: This study aims to analyse the knowledge of cochlear implant (CI) candidacy criteria of otorhinolaryngology specialists in Spain, and from the results, consider whether it is necessary to implement training measures aimed at improving knowledge in this area. MATERIAL AND METHODS: A questionnaire was designed for measuring the level of knowledge of cochlear implant candidacy criteria (CI) in people with hearing loss. The questionnaire collected the demographic data of the respondents and their knowledge on the conventional and emergency indications for CI, technical characteristics of CI and results in the implanted population. RESULTS: A total of 222 Spanish specialists in otorhinolaryngology answered the questionnaire (10.29% of the sample surveyed). CONCLUSIONS: The 50% of all respondents showed a medium-high knowledge about CI. Epidemiological data suggest that a high percentage of adults with postlocutive deafness and candidates for a CI are not referred for treatment. The lack of knowledge about the criteria for the indication of CI by otorhinolaryngology specialists may contribute to inadequate guidance of patients who are potential candidates for CI. The greatest shortcomings are found in the most emergency indications for a CI. Among otorhinolaryngology professionals, the greatest knowledge about CI is found in those who work in tertiary hospitals in the areas of otology and otoneurology, either in the public or private sector. This study suggests that training on CI should be increased for otorhinolaryngology professionals, especially for general otorhinolaryngologists.


Assuntos
Implante Coclear , Implantes Cocleares , Conhecimentos, Atitudes e Prática em Saúde , Perda Auditiva/cirurgia , Otolaringologia , Autorrelato , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Espanha
10.
Ophthalmic Genet ; 28(3): 151-5, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17896313

RESUMO

The Usher syndrome (USH) is an autosomal recessive hereditary disorder characterized by the association of sensorineural hearing loss, retinitis pigmentosa (RP) and, in some cases, vestibular dysfunction. The USH1G gene, encoding SANS, has been found to cause both Usher syndrome type I and atypical Usher syndrome. 109 Spanish unrelated patients suffering from Usher syndrome type I, type II, type III and unclassified Usher syndrome were screened for mutations in this gene, but only eight different changes without a clear pathogenic effect have been detected. Based on these results as well as previous studies in other populations where mutational analysis of this gene has been carried out, one can conclude that USH1G has a minor involvement in Usher syndrome pathogenesis.


Assuntos
Testes Genéticos , Proteínas do Tecido Nervoso/genética , Síndromes de Usher/genética , Sequência de Aminoácidos , Análise Mutacional de DNA , Humanos , Dados de Sequência Molecular , Mutação , Espanha , Síndromes de Usher/classificação
11.
Acta Otolaryngol ; 127(6): 579-86, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17503226

RESUMO

CONCLUSION: Achieving deep insertions, as well as good speech perception results, the FLEXsoft electrode array allows for some preservation in subjects with measurable low frequency hearing, even after a period of time. This opens the door for future research in electrode design, hearing preservation research and drug delivery systems. OBJECTIVES: The FLEXsoft electrode is designed to be atraumatic to the structures of the cochlea during deep insertion of a cochlear implant electrode. This paper reports on the surgical and functional outcomes in implantations with the FLEXsoft electrode array. PATIENTS AND METHODS: Twenty-three adult subjects received a FLEXsoft electrode array and were assessed on speech perception tests (monosyllables, sentences in quiet and in noise), a subjective questionnaire (Nijmegen Cochlear Implant Questionnaire) and a pure-tone audiogram. Results at 1, 3, 6 and 12 months post first fitting were compared to scores from the preoperative interval. RESULTS: Surgery was uneventful in all cases, the surgical handling was satisfactory and correct position of the electrode was achieved in all cases. Hearing could be preserved (as determined by the audiogram) in half of the subjects who had measurable audiograms preoperatively at the 1 month test interval, and in a quarter of subjects after 12 months of device use, despite deep insertion of the electrode. Speech perception scores showed significant improvement over time, as did quality of life scores, and were comparable to results with the standard electrode array as used in the COMBI 40+ and PULSARCI100.


Assuntos
Implante Coclear/instrumentação , Perda Auditiva Neurossensorial/cirurgia , Qualidade de Vida/psicologia , Adulto , Eletrodos Implantados , Desenho de Equipamento , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Índice de Gravidade de Doença , Testes de Discriminação da Fala , Percepção da Fala/fisiologia , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
12.
Int J Pediatr Otorhinolaryngol ; 69(12): 1667-74, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16168497

RESUMO

OBJECTIVE: The aim of this study is to determine whether implanted children using the ACE speech coding strategy demonstrate superior performances compared to implanted children using the SPEAK speech coding strategy over time. METHODS: Cochlear implanted children with prelinguistic sensorineural bilateral deafness of profound degree, using either the ACE or SPEAK coding strategy, were evaluated and compared. Both groups of children used one of the speech coding strategies continuously from the initial programming session and for a period of 2 years post-switch-on. One group comprised children who were retrospectively implanted and had received the SPEAK speech coding strategy (n=32) and the second group consisted of prospectively implanted children who received the ACE speech coding strategy (n=26). Both populations were homogenous as far as age of implantation, degree of hearing loss, anatomy of the cochlea, depth of electrode insertion, and educational and rehabilitative support provided. Children were assessed at 6, 12 and 24 months post switch-on via pure-tone audiometry and for speech perception tests. Children using the ACE speech coding strategy were additionally evaluated using the MAIS and MUSS language scales. RESULTS: Satisfactory benefits in speech perception were demonstrated by both groups of implanted children. No significant difference between the mean pure tone thresholds was observed postoperatively between the groups. Two years post switch-on the group using the ACE speech coding strategy demonstrated superior results for vowel discrimination in comparison to children using the SPEAK coding strategy. No significant difference was observed between the groups for performance on discrimination of syllable patterns (ESP) or for disyllablic word recognition tests. Additionally, the group of ACE users demonstrated maximum performance on MAIS and MUSS scales, 2 years post switch-on. CONCLUSIONS: The results clearly demonstrate significant benefit of cochlear implantation in prelinguistically deafened children for speech perception ability when using either the SPEAK or ACE speech coding strategies. Children using the ACE speech coding strategy demonstrate more rapid progress in improved speech perception ability initially, however 2 years post switch-on, no significant difference in performance on open-set speech recognition tests can be noted irrespective of the strategy in use.


Assuntos
Limiar Auditivo , Implantes Cocleares , Perda Auditiva Neurossensorial/reabilitação , Percepção da Fala , Audiometria de Tons Puros , Audiometria da Fala , Criança , Pré-Escolar , Estimulação Elétrica , Feminino , Humanos , Lactente , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
13.
Hum Mutat ; 22(6): 451-6, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14635104

RESUMO

Inherited hearing impairment affects one in 2,000 newborns. Nonsyndromic prelingual forms are inherited mainly as autosomal recessive traits, for which 16 genes are currently known. Mutations in the genes encoding connexins 26 and 30 account for up to 50% of these cases. However, the individual contribution of the remaining genes to the whole remains undetermined. In addition, for most of the genes there is a need for studies on genotype-phenotype correlations, to identify distinctive clinical features which may direct the molecular diagnosis to specific genes. Here we present a mutation analysis and a genotype-phenotype correlation study on the gene encoding otoferlin (OTOF), responsible for the DFNB9 subtype of prelingual hearing impairment. Four novel mutations were identified: c.2122C>T (p.Arg708Ter), c.4275G>A (p.Trp1425Ter), c.4362+2T>G, and c.5860_5862delATC (p.Ile1954del). A total of 37 subjects with mutations in OTOF were studied clinically. They were phenotypically homogeneous, having profound hearing impairment with very early onset, as shown by pure-tone audiometry and auditory brainstem responses. Magnetic resonance imaging and computed tomography did not reveal any inner ear malformation. Unexpectedly, transient evoked otoacoustic emissions (TEOAEs) were present, either bilaterally or unilaterally in 11 subjects. Altogether, clinical data of these subjects met the diagnostic criteria of auditory neuropathy. A total of 10 subjects had been successfully provided with cochlear implants. The results of our study indicate that genetic diagnosis of subjects with auditory neuropathy and profound hearing impairment should be directed to the otoferlin gene. Our data are of concern to universal screening programs which use TEOAEs as the first detection test for hearing impairment in newborns, since this technique may overlook a nonnegligible proportion of cases.


Assuntos
Perda Auditiva Neurossensorial/genética , Proteínas de Membrana/genética , Mutação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria de Resposta Evocada/métodos , Criança , Pré-Escolar , Cóclea/diagnóstico por imagem , Cóclea/patologia , DNA/química , DNA/genética , Análise Mutacional de DNA , Técnicas de Diagnóstico Otológico , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Feminino , Genótipo , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Emissões Otoacústicas Espontâneas , Fenótipo , Radiografia
15.
Cochlear Implants Int ; 15(3): 136-44, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24559068

RESUMO

Custom Sound EP™ (CSEP) is an advanced flexible software tool dedicated to recording of electrically evoked compound action potentials (ECAPs) in Nucleus® recipients using Neural Response Telemetry™ (NRT™). European multi-centre studies of the Freedom™ cochlear implant system confirmed that CSEP offers tools to effectively record ECAP thresholds, amplitude growth functions, recovery functions, spread of excitation functions, and rate adaptation functions and an automated algorithm (AutoNRT™) to measure threshold profiles. This paper reports on rate adaptation measurements. Rate adaptation of ECAP amplitudes can successfully be measured up to rates of 495 pulses per second (pps) by repeating conventional ECAP measurements and over a wide range of rates up to 8000 pps using the masked response extraction technique. Rate adaptation did not show a predictable relationship with speech perception and coding strategy channel rate preference. The masked response extraction method offers opportunities to study long-term rate adaptation with well-defined and controlled stimulation paradigms.


Assuntos
Implantes Cocleares , Perda Auditiva Neurossensorial/reabilitação , Vias Neurais/fisiologia , Telemetria/instrumentação , Adulto , Vias Auditivas/fisiologia , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Percepção Sonora
16.
Acta otorrinolaringol. esp ; Acta otorrinolaringol. esp;69(5): 251-259, sept.-oct. 2018. tab
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-178710

RESUMO

INTRODUCCIÓN: Este trabajo pretende analizar el conocimiento del especialista en Otorrinolaringología en España sobre los criterios de indicación de los implantes cocleares (IC) y, según los resultados, considerar si es necesario implementar medidas de formación dirigidas a mejorar el conocimiento en esta área. MATERIAL Y MÉTODOS: Se diseña un cuestionario dirigido a conocer el nivel de conocimiento sobre la indicación de IC en personas con hipoacusia. Este cuestionario recogía información demográfica de los encuestados y conocimientos sobre aspectos como indicaciones convencionales y emergentes de los IC, características técnicas de los IC y resultados en la población implantada. RESULTADOS: Un total de 222 especialistas españoles en Otorrinolaringología respondieron el cuestionario (10,29% de la muestra encuestada). CONCLUSIONES: Un 50% de los encuestados mostraron unos conocimientos medios-altos sobre IC. Datos epidemiológicos sugieren que un alto porcentaje de adultos con sorderas poslocutivas candidatos a un IC no son referidos para tratamiento. El desconocimiento de los criterios para la indicación de IC por parte de los especialistas en Otorrinolaringología puede contribuir a una inadecuada orientación de los pacientes potencialmente candidatos a un IC. Las mayores deficiencias se encontraron en las indicaciones más emergentes de un IC. Dentro de los profesionales de la Otorrinolaringología los mayores conocimientos sobre IC se concentraron en aquellos que trabajaban en hospitales terciarios, especializados en Otología y Otoneurología, y desempeñaban su actividad laboral en el sector público y privado. Este estudio sugiere la conveniencia de incrementar acciones formativas sobre IC en los profesionales de la Otorrinolaringología, especialmente para otorrinolaringólogos generales


INTRODUCTION: This study aims to analyse the knowledge of cochlear implant (CI) candidacy criteria of otorhinolaryngology specialists in Spain, and from the results, consider whether it is necessary to implement training measures aimed at improving knowledge in this area. MATERIAL AND METHODS: A questionnaire was designed for measuring the level of knowledge of cochlear implant candidacy criteria (CI) in people with hearing loss. The questionnaire collected the demographic data of the respondents and their knowledge on the conventional and emergency indications for CI, technical characteristics of CI and results in the implanted population. RESULTS: A total of 222 Spanish specialists in otorhinolaryngology answered the questionnaire (10.29% of the sample surveyed). CONCLUSIONS: The 50% of all respondents showed a medium-high knowledge about CI. Epidemiological data suggest that a high percentage of adults with postlocutive deafness and candidates for a CI are not referred for treatment. The lack of knowledge about the criteria for the indication of CI by otorhinolaryngology specialists may contribute to inadequate guidance of patients who are potential candidates for CI. The greatest shortcomings are found in the most emergency indications for a CI. Among otorhinolaryngology professionals, the greatest knowledge about CI is found in those who work in tertiary hospitals in the areas of otology and otoneurology, either in the public or private sector. This study suggests that training on CI should be increased for otorhinolaryngology professionals, especially for general otorhinolaryngologists


Assuntos
Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Implantes Cocleares , Autorrelato , Perda Auditiva/cirurgia , Conhecimentos, Atitudes e Prática em Saúde , Otolaringologia , Espanha
17.
Acta otorrinolaringol. esp ; Acta otorrinolaringol. esp;74(2): 124-132, marzo-abril 2023. tab
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-217391

RESUMO

A día de hoy, todavía no disponemos de un conocimiento ni una concienciación adecuados sobre las consecuencias que alcanza en la calidad de vida la pérdida de audición en personas mayores. De la misma manera, tampoco existe información suficiente en cuanto a la relación de la presbiacusia y las alteraciones del equilibrio con otras comorbilidades. Dicho conocimiento puede contribuir a mejorar tanto la prevención como el tratamiento de estas patologías, a reducir su impacto en otras áreas como la cognición o la autonomía, así como para poseer una información más certera sobre el impacto económico que generan en la sociedad y en el sistema sanitario.Por ello, con la realización de este artículo de revisión nos planteamos actualizar la información sobre el tipo de hipoacusia y las alteraciones del equilibrio en personas mayores de 55 años, así como sus factores asociados; analizar el impacto que genera en la calidad de vida de estas personas y el que se puede generar a nivel personal y poblacional (tanto en el ámbito sociológico como económico) si se persigue una intervención temprana en estos pacientes. (AU)


At this time, we still do not have adequate knowledge and awareness of the consequences of hearing loss in the elderly on quality of life. Similarly, there is also insufficient information on the relationship of presbycusis and balance disorders with other comorbidities. Such knowledge can contribute to improve both prevention and treatment of these pathologies, to reduce their impact on other areas such as cognition or autonomy, as well as to have more accurate information on the economic impact they generate in society and in the health system.Therefore, with this review article we aim to update the information on the type of hearing loss and balance disorders in people over 55 years of age, and their associated factors; to analyze the impact on the quality of life of these people and the one which can be generated at a personal and population level (both sociological and economic) if an early intervention in these patients is pursued. (AU)


Assuntos
Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Presbiacusia , Perda Auditiva , Cognição , Otolaringologia , Presbiacusia/prevenção & controle , Perda Auditiva/complicações , Perda Auditiva/terapia
18.
Acta Otolaryngol ; 132(10): 1084-94, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22667256

RESUMO

CONCLUSION: The use of a hearing aid (HA) in combination with a cochlear implant (CI) significantly improved performance for speech perception in quiet, in noise, and for localization compared with monaural conditions. No significant differences in functional performance were observed following optimization of HA fitting. OBJECTIVES: To evaluate the binaural benefits derived from using a contralateral HA in conjunction with a CI in subjects with significant functional hearing in the nonimplanted ear and the effects of HA fitting optimization. METHODS: Fifteen adult CI users, intra-subject controls, were enrolled in a prospective repeated-measure multicenter study. Evaluation of performance for speech understanding, localization, and subjective impressions was conducted before and following HA fitting optimization for CI alone, HA alone, and CI + HA. RESULTS: For speech testing in quiet, bimodal scores were significantly better than for HA alone and CI alone conditions (p < 0.01). For speech and noise (S0N0) at 0° azimuth the scores were significantly better in the bimodal condition than for CI alone (p = 0.01), indicating binaural summation. When noise was presented to the HA side (S0NHA) bimodal scores were significantly better than for CI alone (p < 0.01 and p < 0.05, respectively), suggesting a significant binaural squelch effect. Sound localization ability was significantly improved in the bimodal condition compared with the CI alone condition (p = 0.002).


Assuntos
Limiar Auditivo/fisiologia , Implantes Cocleares , Auxiliares de Audição , Perda Auditiva Bilateral/terapia , Localização de Som , Percepção da Fala , Adulto , Idoso , Audiometria de Tons Puros , Audiometria da Fala/métodos , Estudos de Casos e Controles , Implante Coclear/métodos , Terapia Combinada , Feminino , Seguimentos , Perda Auditiva Bilateral/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Adulto Jovem
19.
Acta Otorrinolaringol Esp ; 61(3): 180-3, 2010.
Artigo em Espanhol | MEDLINE | ID: mdl-20223435

RESUMO

INTRODUCTION: Acute mastoiditis (AM) is a paediatric infectious complication that raises a specific problem in case of implanted patients. OBJECTIVE: To review the cases of AM in a paediatric cochlear implant (CI) programme to study its incidence and associated problems. MATERIALS AND METHODS: A retrospective study was conducted on 248 children aged between 8 months and 14 years who underwent CI from 1994 to 2009. The demographics, clinical data and their treatment were analyzed. RESULTS: Five patients developed acute mastoiditis (2.01%), three of them with subperiosteal abscess (1.21%). The mean age of implantation was 2 years and 4 months, and the complication presented between 1 and 33 months post-implantation (mean, 11.6 months). Four patients had episodes of serous otitis preimplantation. The mean age of AM patients was of 3 years and 4 months. The CI type was nucleus in all cases. CONCLUSIONS: Conservative management is suggested for AM and subperiosteal abscess in children with cochlear implants. Surgical treatment should be avoided to prevent CI contamination. The first option is intravenous antibiotics and simple puncture of the abscess. If surgical drainage is needed, radiological study should be performed to locate the CI electrodes.


Assuntos
Implantes Cocleares , Mastoidite , Doença Aguda , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Mastoidite/diagnóstico , Mastoidite/epidemiologia , Mastoidite/terapia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA