Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Med Imaging (Bellingham) ; 7(3): 034501, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32613029

RESUMO

Purpose: Diabetic retinopathy is the leading cause of blindness, affecting over 93 million people. An automated clinical retinal screening process would be highly beneficial and provide a valuable second opinion for doctors worldwide. A computer-aided system to detect and grade the retinal images would enhance the workflow of endocrinologists. Approach: For this research, we make use of a publicly available dataset comprised of 3662 images. We present a hybrid machine learning architecture to detect and grade the level of diabetic retinopathy (DR) severity. We also present and compare simple transfer learning-based approaches using established networks such as AlexNet, VGG16, ResNet, Inception-v3, NASNet, DenseNet, and GoogLeNet for DR detection. For the grading stage (mild, moderate, proliferative, or severe), we present an approach of combining various convolutional neural networks with principal component analysis for dimensionality reduction and a support vector machine classifier. We study the performance of these networks under different preprocessing conditions. Results: We compare these results with various existing state-of-the-art approaches, which include single-stage architectures. We demonstrate that this architecture is more robust to limited training data and class imbalance. We achieve an accuracy of 98.4% for DR detection and an accuracy of 96.3% for distinguishing severity of DR, thereby setting a benchmark for future research efforts using a limited set of training images. Conclusions: Results obtained using the proposed approach serve as a benchmark for future research efforts. We demonstrate as a proof-of-concept that an automated detection and grading system could be developed with a limited set of images and labels. This type of independent architecture for detection and grading could be used in areas with a scarcity of trained clinicians based on the necessity.

2.
J Med Imaging (Bellingham) ; 5(1): 014504, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29487880

RESUMO

We study the performance of a computer-aided detection (CAD) system for lung nodules in computed tomography (CT) as a function of slice thickness. In addition, we propose and compare three different training methodologies for utilizing nonhomogeneous thickness training data (i.e., composed of cases with different slice thicknesses). These methods are (1) aggregate training using the entire suite of data at their native thickness, (2) homogeneous subset training that uses only the subset of training data that matches each testing case, and (3) resampling all training and testing cases to a common thickness. We believe this study has important implications for how CT is acquired, processed, and stored. We make use of 192 CT cases acquired at a thickness of 1.25 mm and 283 cases at 2.5 mm. These data are from the publicly available Lung Nodule Analysis 2016 dataset. In our study, CAD performance at 2.5 mm is comparable with that at 1.25 mm and is much better than at higher thicknesses. Also, resampling all training and testing cases to 2.5 mm provides the best performance among the three training methods compared in terms of accuracy, memory consumption, and computational time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA