Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Br J Anaesth ; 118(3): 355-362, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28186263

RESUMO

Background: During fluid challenge, volume expansion (VE)-induced increase in cardiac output (Δ VE CO) is seldom measured. Methods: In patients with shock undergoing strictly controlled mechanical ventilation and receiving VE, we assessed minimally invasive surrogates for Δ VE CO (by transthoracic echocardiography): fluid-induced increases in end-tidal carbon dioxide (Δ VE E'CO2 ); pulse (Δ VE PP), systolic (Δ VE SBP), and mean systemic blood pressure (Δ VE MBP); and femoral artery Doppler flow (Δ VE FemFlow). In the absence of arrhythmia, fluid-induced decrease in heart rate (Δ VE HR) and in pulse pressure respiratory variation (Δ VE PPV) were also evaluated. Areas under the receiver operating characteristic curves (AUC ROC s) reflect the ability to identify a response to VE (Δ VE CO ≥15%). Results: In 86 patients, Δ VE E'CO2 had an AUC ROC =0.82 [interquartile range 0.73-0.90], significantly higher than the AUC ROC for Δ VE PP, Δ VE SBP, Δ VE MBP, and Δ VE FemFlow (AUC ROC =0.61-0.65, all P <0.05). A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) had good positive (5.0 [2.6-9.8]) and fair negative (0.29 [0.2-0.5]) likelihood ratios. The 16 patients with arrhythmia had similar relationships between Δ VE E'CO2 and Δ VE CO to patients with regular rhythm ( r 2 =0.23 in both subgroups). In 60 patients with no arrhythmia, Δ VE E'CO2 (AUC ROC =0.84 [0.72-0.92]) outperformed Δ VE HR (AUC ROC =0.52 [0.39-0.66], P <0.05) and tended to outperform Δ VE PPV (AUC ROC =0.73 [0.60-0.84], P =0.21). In the 45 patients with no arrhythmia and receiving ventilation with tidal volume <8 ml kg -1 , Δ VE E'CO2 performed better than Δ VE PPV, with AUC ROC =0.86 [0.72-0.95] vs 0.66 [0.49-0.80], P =0.02. Conclusions: Δ VE E'CO2 outperformed Δ VE PP, Δ VE SBP, Δ VE MBP, Δ VE FemFlow, and Δ VE HR and, during protective ventilation, arrhythmia, or both, it also outperformed Δ VE PPV. A value of Δ VE E'CO2 >1 mm Hg (>0.13 kPa) indicated a likely response to VE.


Assuntos
Dióxido de Carbono/metabolismo , Baixo Débito Cardíaco/diagnóstico , Baixo Débito Cardíaco/metabolismo , Ecocardiografia/métodos , Hidratação , Idoso , Baixo Débito Cardíaco/fisiopatologia , Cuidados Críticos/métodos , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração Artificial , Volume de Ventilação Pulmonar
2.
Anaesthesia ; 72(6): 719-728, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28294285

RESUMO

Bronchoscopy during mechanical ventilation of patients' lungs significantly affects ventilation because of partial obstruction of the tracheal tube, and may thus be omitted in the most severely ill patients. It has not previously been possible to reduce the external diameter of the bronchoscope without reducing the diameter of the suction channel, thus reducing the suctioning capacity of the device. We believed that a better-designed bronchoscope could improve the safety of bronchoscopy in patients whose lungs were ventilated. We designed a flexible bronchoscope prototype with a drumstick-shaped head consisting of a long, thin proximal portion; a short and large distal portion for camera docking; and a large suction channel throughout the length of the device. The aims of our study were to test the impact of our prototype on mechanical ventilation when inserted into the tracheal tube, and to assess suctioning capacity. We first tested the efficiency of the suction channel, and demonstrated that the suction flow of the prototype was similar to that of conventional adult bronchoscopes. We next evaluated the consequences of bronchoscopy when using the prototype on minute ventilation and intrathoracic pressures during mechanical ventilation: firstly, in vitro using a breathing simulator; and secondly, in vivo using a porcine model of pulmonary ventilation. The insertion of adult bronchoscopes into the tracheal tube immediately impaired the protective ventilation strategy employed, whereas the prototype preserved it. For the first time, we have developed an innovative flexible bronchoscope designed for bronchoscopy during invasive mechanical ventilation, that both preserved the protective ventilation strategy, and enabled efficient suction flow.


Assuntos
Broncoscópios , Broncoscopia/instrumentação , Respiração Artificial/métodos , Adulto , Manuseio das Vias Aéreas , Animais , Simulação por Computador , Desenho de Equipamento , Feminino , Tecnologia de Fibra Óptica , Humanos , Intubação Intratraqueal , Masculino , Síndrome do Desconforto Respiratório/terapia , Sucção , Suínos
3.
Anaesthesia ; 71(2): 185-91, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26559154

RESUMO

Flexible bronchoscopy is essential for appropriate care during mechanical ventilation, but can significantly affect mechanical ventilation of the lungs, particularly for patients with acute respiratory distress syndrome. We aimed to describe the consequences of bronchoscopy during lung-protective ventilation in a bench study, and thereby to determine the optimal diameter of the bronchoscope for avoiding disruption of the protective-ventilation strategy during the procedure. Immediately following the insertion of the bronchoscope into the tracheal tube, either minute ventilation decreased significantly, or positive end-expiratory pressure increased substantially, according to the setting of the inspiratory pressure limit. The increase in end-expiratory pressure led to an equivalent increase in the plateau pressure, and lung-protective ventilation was significantly altered during the procedure. We showed that a bronchoscope with an external diameter of 4 mm (or less) would allow safer bronchoscopic interventions in patients with severe acute respiratory distress syndrome.


Assuntos
Broncoscopia/instrumentação , Modelos Biológicos , Respiração Artificial , Síndrome do Desconforto Respiratório/fisiopatologia , Adulto , Desenho de Equipamento , Tecnologia de Fibra Óptica , Humanos , Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório/terapia
6.
Ann Intensive Care ; 10(1): 62, 2020 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-32449053

RESUMO

BACKGROUND: No recommendation exists about the timing and setting for tracheal intubation and mechanical ventilation in septic shock. PATIENTS AND METHODS: This prospective multicenter observational study was conducted in 30 ICUs in France and Spain. All consecutive patients presenting with septic shock were eligible. The use of tracheal intubation was described across the participating ICUs. A multivariate analysis was performed to identify parameters associated with early intubation (before H8 following vasopressor onset). RESULTS: Eight hundred and fifty-nine patients were enrolled. Two hundred and nine patients were intubated early (24%, range 4.5-47%), across the 18 centers with at least 20 patients included. The cumulative intubation rate during the ICU stay was 324/859 (38%, range 14-65%). In the multivariate analysis, seven parameters were significantly associated with early intubation and ranked as follows by decreasing weight: Glasgow score, center effect, use of accessory respiratory muscles, lactate level, vasopressor dose, pH and inability to clear tracheal secretions. Global R-square of the model was only 60% indicating that 40% of the variability of the intubation process was related to other parameters than those entered in this analysis. CONCLUSION: Neurological, respiratory and hemodynamic parameters only partially explained the use of tracheal intubation in septic shock patients. Center effect was important. Finally, a vast part of the variability of intubation remained unexplained by patient characteristics. Trial registration Clinical trials NCT02780466, registered on May 23, 2016. https://clinicaltrials.gov/ct2/show/NCT02780466?term=intubatic&draw=2&rank=1.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA