Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Cochrane Database Syst Rev ; 6: CD010735, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-37369549

RESUMO

BACKGROUND: Cataract is the leading cause of blindness in the world and, as such, cataract surgery is one of the most commonly performed operations globally. Surgical techniques have changed dramatically over the past half century with associated improvements in outcomes and safety. Femtosecond lasers can be used to perform the key steps in cataract surgery, such as corneal incisions, lens capsulotomy and fragmentation. The potential advantage of femtosecond laser-assisted cataract surgery (FLACS) is greater precision and reproducibility of these steps compared to manual techniques. The disadvantages are the costs associated with FLACS technology. OBJECTIVES: To compare the effectiveness and safety of FLACS with standard ultrasound phacoemulsification cataract surgery (PCS) by gathering evidence from randomised controlled trials (RCTs). SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL; which contains the Cochrane Eyes and Vision Trials Register; 2022, Issue 5); Ovid MEDLINE; Ovid Embase; LILACS; the ISRCTN registry; ClinicalTrials.gov; the WHO ICTRP and the US Food and Drug Administration (FDA) website. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 May 2022. SELECTION CRITERIA: We included RCTs where FLACS was compared to PCS. DATA COLLECTION AND ANALYSIS: Three review authors independently screened the search results, assessed risk of bias and extracted data using the standard methodological procedures expected by Cochrane. The primary outcome for this review was intraoperative complications in the operated eye, namely anterior capsule, and posterior capsule tears. The secondary outcomes included corrected distance visual acuity (CDVA), quality of vision (as measured by any validated patient-reported outcome measure (PROM)), postoperative cystoid macular oedema complications, endothelial cell loss and cost-effectiveness. We assessed the certainty of the evidence using GRADE. MAIN RESULTS: We included 42 RCTs conducted in Europe, North America, South America and Asia, which enrolled a total of 7298 eyes of 5831 adult participants. Overall, the studies were at unclear or high risk of bias. In 16 studies the authors reported financial links with the manufacturer of the laser platform evaluated in their studies. Thirteen of the studies were within-person (paired-eye) studies with one eye allocated to one procedure and the other eye allocated to the other procedure. These studies were reported ignoring the paired nature of the data. There was low-certainty evidence of little or no difference in the odds of developing anterior capsular tears when comparing FLACS and PCS (Peto odds ratio (OR) 0.83, 95% confidence interval (CI) 0.40 to 1.72; 5835 eyes, 27 studies) There was one fewer anterior capsule tear per 1000 operations in the FLACS group compared with the PCS group (95% CI 4 fewer to 3 more).  There was low-certainty evidence of lower odds of developing posterior capsular tears with FLACS compared to PCS (Peto OR 0.50, 95% CI 0.25 to 1.00; 5767 eyes, 26 studies). There were four fewer posterior capsule tears per 1000 operations in the FLACS group compared with the PCS group (95% CI 6 fewer to same).  There was moderate-certainty evidence of a very small advantage for the FLACS arm with regard to CDVA at six months or more follow-up, (mean difference (MD) -0.01 logMAR, 95% CI -0.02 to 0.00; 1323 eyes, 7 studies). This difference is equivalent to 1 logMAR letter between groups and is not thought to be clinically important. From the three studies (1205 participants) reporting a variety of PROMs (Cat-PROMS, EQ-5D, EQ-SD-3L, Catquest9-SF and patient survey) up to three months following surgery, there was moderate-certainty evidence of little or no difference in the various parameters between the two treatment arms. There was low-certainty evidence of little or no difference in the odds of developing cystoid macular oedema when comparing FLACS and PCS (Peto OR 0.84, 95% CI 0.56 to 1.28; 4441 eyes, 18 studies). There were three fewer cystoid macular oedema cases per 1000 operations in the FLACS group compared with the PCS group (95% CI 10 fewer to 6 more).  In one study the incremental cost-effectiveness ratio (ICER) (cost difference divided by quality-adjusted life year (QALY) difference) was GBP £167,620 when comparing FLACS to PCS. In another study, the ICER was EUR €10,703 saved per additional patient who had treatment success with PCS compared to FLACS. Duration ranged from three minutes in favour of FLACS to eight minutes in favour of PCS (I2 = 100%, 11 studies) (low-certainty evidence).  There was low-certainty evidence of little or no important difference in endothelial cell loss when comparing FLACS with PCS (MD 12 cells per mm2 in favour of FLACS, 95% CI -40 to 64; 1512 eyes, 10 studies).  AUTHORS' CONCLUSIONS: This review of 42 studies provides evidence that there is probably little or no difference between FLACS and PCS in terms of intraoperative and postoperative complications, postoperative visual acuity and quality of life. Evidence from two studies suggests that FLACS may be the less cost-effective option. Many of the included studies only investigated very specific outcome measures such as effective phacoemulsification time, endothelial cell count change or aqueous flare, rather than those directly related to patient outcomes. Standardised reporting of complications and visual and refractive outcomes for cataract surgery would facilitate future synthesis, and guidance on this has been recently published.


ANTECEDENTES: La catarata es la principal causa de ceguera en el mundo y, como tal, la cirugía de cataratas es una de las operaciones más realizadas en todo el mundo. Las técnicas quirúrgicas han cambiado radicalmente en el último medio siglo, con las consiguientes mejoras en los desenlaces y la seguridad. Los láseres de femtosegundo se pueden utilizar para realizar los pasos clave de la cirugía de cataratas, como las incisiones corneales, la capsulotomía y la fragmentación del cristalino. La ventaja potencial de la cirugía de cataratas asistida por láser de femtosegundo (FLACS por sus siglas en inglés) es la mayor precisión y reproducibilidad de estos pasos en comparación con las técnicas manuales. Las desventajas son los costes asociados con la tecnología FLACS. OBJETIVOS: Comparar la eficacia y la seguridad de la FLACS con la cirugía de cataratas estándar por facoemulsificación (PCS) con ultrasonido mediante la recopilación de evidencia de ensayos controlados aleatorizados (ECA). MÉTODOS DE BÚSQUEDA: Se realizaron búsquedas en el Registro Cochrane central de ensayos controlados (Cochrane Central Register of Controlled Trials [CENTRAL]; que contiene el Registro de ensayos del Grupo Cochrane de Salud ocular y de la visión [Cochrane Eyes and Vision]; 2022, número 5); en Ovid MEDLINE; Ovid Embase; LILACS; el registro ISRCTN; ClinicalTrials.gov; la ICTRP de la OMS y el sitio web de la Food and Drug Administration (FDA) de los EE. UU. No se aplicaron restricciones de fecha ni de idioma en las búsquedas electrónicas de ensayos. La última búsqueda en las bases de datos electrónicas se realizó el 10 de mayo de 2022. CRITERIOS DE SELECCIÓN: Se incluyeron los ECA en los que la FLACS se comparó con la PCS. OBTENCIÓN Y ANÁLISIS DE LOS DATOS: Tres autores de la revisión examinaron de forma independiente los resultados de la búsqueda, evaluaron el riesgo de sesgo y extrajeron los datos mediante los procedimientos metodológicos estándar previstos por Cochrane. El desenlace principal de esta revisión fueron las complicaciones intraoperatorias en el ojo operado, concretamente, desgarros de la cápsula anterior y posterior. Los desenlaces secundarios incluyeron la agudeza visual corregida a distancia (AVCD), la calidad de la visión (medida por cualquier medida de desenlace notificada por el paciente [PROM] validada), las complicaciones posoperatorias del edema macular cistoide, la pérdida de células endoteliales y la coste­efectividad. La certeza de la evidencia se evaluó mediante el método GRADE. RESULTADOS PRINCIPALES: Se incluyeron 42 ECA realizados en Europa, Norteamérica, Sudamérica y Asia, que reclutaron un total de 7298 ojos de 5831 participantes adultos. En general, los estudios tuvieron riesgo de sesgo incierto o alto. En 16 estudios, los autores informaron vínculos financieros con el fabricante de la plataforma láser evaluada en sus estudios. Trece de los estudios fueron estudios intrapersonales (ojo pareado) con un ojo asignado a un procedimiento y el otro ojo asignado al otro procedimiento. El informe de estos estudios no consideró la naturaleza pareada de los datos. Hubo evidencia de certeza baja de poca o ninguna diferencia en las probabilidades de desarrollar desgarros de la cápsula anterior al comparar FLACS y PCS (odds ratio [OR] de Peto 0,83; intervalo de confianza [IC] del 95%: 0,40 a 1,72; 5835 ojos, 27 estudios). Hubo un desgarro de la cápsula anterior menos por cada 1000 cirugías en el grupo de FLACS en comparación con el grupo de PCS (IC del 95%: 4 menos a 3 más).  Hubo evidencia de certeza baja de menores probabilidades de desarrollar desgarros de la cápsula posterior con FLACS en comparación con PCS (OR de Peto 0,50; IC del 95%: 0,25 a 1,00; 5767 ojos, 26 estudios). Hubo cuatro desgarros de la cápsula posterior menos por cada 1000 cirugías en el grupo de FLACS en comparación con el grupo de PCS (IC del 95%: 6 menos a igual).  Hubo evidencia de certeza moderada de una ventaja muy pequeña en el grupo de FLACS con respecto a la AVCD a los seis meses o más de seguimiento, (diferencia de medias [DM] ­0,01 logMAR; IC del 95%: ­0,02 a 0,00; 1323 ojos, siete estudios). Esta diferencia equivale a 1 letra logMAR entre los grupos y no se considera clínicamente importante. De los tres estudios (1205 participantes) que informaron sobre una variedad de PROM (Cat­PROMS, EQ­5D, EQ­SD­3L, Catquest9­SF y encuesta de pacientes) hasta tres meses después de la cirugía, hubo evidencia de certeza moderada de poca o ninguna diferencia en los diversos parámetros entre los dos grupos de tratamiento. Hubo evidencia de certeza baja de poca o ninguna diferencia en las probabilidades de desarrollar edema macular cistoide al comparar FLACS y PCS (OR de Peto 0,84; IC del 95%: 0,56 a 1,28; 4441 ojos, 18 estudios). Hubo tres casos menos de edema macular cistoide por cada 1000 cirugías en el grupo de FLACS en comparación con el grupo de PCS (IC del 95%: 10 menos a 6 más).  En un estudio, el cociente coste­efectividad incremental (ICER) (diferencia de coste dividida por la diferencia de años de vida ajustados por la calidad [AVAC]) fue de 167 620 GBP al comparar FLACS con SCP. En otro estudio, el ICER fue de 10 703 euros ahorrados por paciente adicional que tuvo un tratamiento exitoso con PCS en comparación con FLACS. La duración varió entre tres minutos a favor de FLACS y ocho minutos a favor de PCS (I 2 = 100%, 11 estudios) (evidencia de certeza baja).  Hubo evidencia de certeza baja de poca o ninguna diferencia importante en la pérdida de células endoteliales al comparar la FLACS con la PCS (DM 12 células por mm 2 a favor de la FLACS; IC del 95%: ­40 a 64; 1512 ojos, 10 estudios).  CONCLUSIONES DE LOS AUTORES: Esta revisión de 42 estudios aporta evidencia de que probablemente haya poca o ninguna diferencia entre la FLACS y la PCS en cuanto a las complicaciones intraoperatorias y posoperatorias, la agudeza visual posoperatoria y la calidad de vida. La evidencia de dos estudios indica que la FLACS podría ser la opción menos coste­efectiva. Muchos de los estudios incluidos solo investigaron medidas de desenlace muy específicas, como el tiempo efectivo de facoemulsificación, el cambio en el recuento de células endoteliales o el brote acuoso, en lugar de las directamente relacionadas con los desenlaces de los pacientes. La notificación estandarizada de las complicaciones y los desenlaces visuales y refractarios de la cirugía de cataratas facilitaría la síntesis futura, y recientemente se han publicado guías al respecto.


Assuntos
Extração de Catarata , Catarata , Edema Macular , Facoemulsificação , Humanos , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Edema Macular/etiologia , Extração de Catarata/efeitos adversos , Catarata/complicações , Lasers
2.
Ophthalmology ; 124(10): 1485-1495, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28532974

RESUMO

PURPOSE: To evaluate the cost effectiveness of corneal collagen crosslinking (CXL) for progressive keratoconus from the healthcare payer's perspective. DESIGN: A probabilistic Markov-type model using data from published clinical trials and cohort studies. PARTICIPANTS: Two identical cohorts, each comprising 1000 virtual patients with progressive bilateral keratoconus, were modeled; one cohort underwent CXL and the other cohort received no intervention. METHODS: Both cohorts were modeled and evaluated annually over a lifetime. Quality-adjusted life years (QALYs), total cost, disease progression, and the probability of corneal transplantation, graft failure, or both were calculated based on data from published trials and cohort studies. These outcomes were compared between the 2 cohorts. In our base scenario, the stabilizing effect of CXL was assumed to be 10 years; however, longer durations also were analyzed. One-way sensitivity analyses were performed to test the robustness of the outcomes. MAIN OUTCOME MEASURE: Incremental cost-effectiveness ratio (ICER), defined as euros per QALY. RESULTS: Assuming a 10-year effect of CXL, the ICER was €54 384/QALY ($59 822/QALY). When we adjusted the effect of CXL to a lifelong stabilizing effect, the ICER decreased to €10 149/QALY ($11 163/QALY). Other sensitivity and scenario analyses that had a relevant impact on ICER included the discount rate, visual acuity before CXL, and healthcare costs. CONCLUSIONS: Corneal collagen crosslinking for progressive keratoconus is cost effective at a willingness-to-pay threshold of 3 times the current gross domestic product (GDP) per capita. Moreover, a longer stabilizing effect of CXL increases cost effectiveness. If CXL had a stabilizing effect on keratoconus of 15 years or longer, then the ICER would be less than the 1 × GDP per capita threshold and thus very cost effective.


Assuntos
Colágeno/metabolismo , Substância Própria/metabolismo , Análise Custo-Benefício , Reagentes de Ligações Cruzadas/economia , Ceratocone/economia , Fotoquimioterapia/economia , Fármacos Fotossensibilizantes/economia , Adulto , Transplante de Córnea , Progressão da Doença , Seguimentos , Custos de Cuidados de Saúde , Humanos , Ceratocone/tratamento farmacológico , Ceratocone/metabolismo , Cadeias de Markov , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida , Riboflavina/economia , Raios Ultravioleta , Acuidade Visual/fisiologia , Adulto Jovem
3.
Exp Eye Res ; 153: 141-151, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27765574

RESUMO

The aim of this study was to investigate corneal enzymatic resistance following epithelium off and on riboflavin/UVA cross-linking (CXL). One hundred and fourteen porcine eyes were divided into four non-irradiated control groups and seven CXL groups. The latter comprised; (i) epithelium-off, 0.1% iso-osmolar riboflavin, 9 mW UVA irradiation for 10 min, (ii) disrupted epithelium, 0.1% hypo-osmolar riboflavin, 9 mW UVA for 10 min, (iii) epithelium-on, 0.25% hypo-osmolar riboflavin with 0.01% benzylalkonium chloride (BACS), 9 mW UVA for 10 min, (iv) epithelium-on, 5 min iontophoresis at 0.1 mA for 5 min with 0.1% riboflavin solution, 9 mW UVA for 10 min or (v) 12.5 min, (vi) epithelium-on, prolonged iontophoresis protocol of 25 min with 1.0 mA for 5 min and 0.5 mA for 5 min with 0.25% riboflavin with 0.01% BACS, 9 mW UVA for 10 min or (vii) 12.5 min. Enzymatic resistance was assessed by daily measurement of a corneal button placed in pepsin solution and measurement of corneal button dry weight after 11 days of digestion. This study revealed that the enzymatic resistance was greater in CXL corneas than non-irradiated corneas (p < 0.0001). Epithelium-off CXL showed the greatest enzymatic resistance (p < 0.0001). The prolonged iontophoresis protocol was found to be superior to all other trans-epithelial protocols (p < 0.0001). A 25% increase in UVA radiance significantly increased corneal enzymatic resistance (p < 0.0001). In conclusion, although epithelium-on CXL appears to be inferior to epithelium-off CXL in terms of enzymatic resistance to pepsin digestion, the outcome of epithelium-on CXL may be significantly improved through the use of higher concentrations of riboflavin solution, a longer duration of iontophoresis and an increase in UVA radiance.


Assuntos
Reagentes de Ligações Cruzadas/uso terapêutico , Resistência a Medicamentos , Epitélio Corneano/efeitos dos fármacos , Ceratocone/tratamento farmacológico , Pepsina A/farmacologia , Fotoquimioterapia/métodos , Riboflavina/farmacologia , Animais , Modelos Animais de Doenças , Epitélio Corneano/metabolismo , Epitélio Corneano/patologia , Ceratocone/metabolismo , Ceratocone/patologia , Fármacos Fotossensibilizantes/farmacologia , Suínos
4.
Eye Vis (Lond) ; 11(1): 8, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38414033

RESUMO

BACKGROUND: Corneal cross-linking (CXL) using riboflavin and ultraviolet-A light (UVA) is a treatment used to prevent progression of keratoconus. This ex vivo study assesses the impact on CXL effectiveness, as measured by tissue enzymatic resistance and confocal microscopy, of including a pre-UVA corneal surface rinse with balanced salt solution (BSS) as part of the epithelium-off treatment protocol. METHODS: Sixty-eight porcine eyes, after epithelial debridement, were assigned to six groups in three experimental runs. Group 1 remained untreated. Groups 2-6 received a 16-min application of 0.1% riboflavin/Hydroxypropyl methylcellulose (HPMC) drops, after which Group 3 was exposed to 9 mW/cm2 UVA for 10 min, and Groups 4-6 underwent corneal surface rinsing with 0.25 mL, 1 mL or 10 mL BSS followed by 9 mW/cm2 UVA exposure for 10 min. Central corneal thickness (CCT) was recorded at each stage. Central 8.0 mm corneal buttons from all eyes were subjected to 0.3% collagenase digestion at 37 °C and the time required for complete digestion determined. A further 15 eyes underwent fluorescence confocal microscopy to assess the impact of rinsing on stromal riboflavin concentration. RESULTS: Application of riboflavin/HPMC solution led to an increase in CCT of 73 ± 14 µm (P < 0.01) after 16 min. All CXL-treated corneas displayed a 2-4 fold greater resistance to collagenase digestion than non-irradiated corneas. There was no difference in resistance between corneas that received no BSS rinse and those that received a 0.25 mL or 1 mL pre-UVA rinse, but each showed a greater level of resistance than those that received a 10 mL pre-UVA rinse (P < 0.05). Confocal microscopy demonstrated reduced stromal riboflavin fluorescence after rinsing. CONCLUSIONS: All protocols, with and without rinsing, were effective at enhancing the resistance to collagenase digestion, although resistance was significantly decreased, and stromal riboflavin fluorescence reduced with a 10 mL rinse. This suggests that a 10 mL surface rinse can reduce the efficacy of CXL through the dilution of the stromal riboflavin concentration.

5.
Eye (Lond) ; 38(1): 76-81, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37355756

RESUMO

OBJECTIVES: To investigate patient understanding of, and attitudes to, premium (toric, extended depth of focus/multifocal) intraocular lenses (premIOLs) in public health sector patients undergoing cataract surgery (CS) in the UK. METHODS: A 12 question survey with Likert scale questions was designed, to assess patient attitudes to post-operative spectacle dependence, refractive target and desirability of spectacle independence whilst considering possible complications of dysphotopsias and need for premIOL exchange/adjustment. RESULTS: 360 surveys were collected. CS had not been performed in 66.5%. Separate spectacles were worn for reading and distance in 28.8%, 19.2% had varifocals, 11.2% bifocals, 22.9% reading glasses only and 1.6% computer glasses only. Contact lenses were not worn in 95.7%. Only 41.6% were drivers. Most patients (85.8%) did not mind wearing glasses after CS, with 78.9% preferring reading glasses, compared with 29.7% preferring distance glasses. Most patients (75.3%) were not familiar with premIOLs, with 58.9% not willing to consider them in the context of a 2% risk of debilitating dysphotopsia and 54.2% rejecting a 5% risk of second surgery. CONCLUSIONS: There is a lack of awareness of premIOLs in public health sector (NHS) patients in the UK, suggesting limitations in the "fully informed" consent process for CS. Most NHS CS patients are currently willing to wear spectacles after CS, especially reading glasses. There is reluctance in such patients to consider premIOLs on a background of small risks of debilitating dysphotopsias and increased risks of a second operation.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Humanos , Saúde Pública , Acuidade Visual
6.
J Clin Med ; 12(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37297881

RESUMO

We read with interest your article describing a new objective method for evaluating glistenings in intraocular lenses (IOLs) in vivo [...].

7.
Int J Ophthalmol ; 16(8): 1237-1242, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37602355

RESUMO

AIM: To assess the performance of a bespoke software for automated counting of intraocular lens (IOL) glistenings in slit-lamp images. METHODS: IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software. The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading. A second set of 63 images, selected using randomised stratified sampling from 290 images, were used for software validation. The images were obtained using a previously described protocol. Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists. RESULTS: A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set. Using this threshold value, only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images (κ=0.104, 95%CI, 0.040-0.168). Ten images (15.9%) had glistenings counts that agreed between the software and manual counting. There were 49 images (77.8%) where the software overestimated the number of glistenings. CONCLUSION: The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application. Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement. The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.

8.
Cornea ; 42(4): 507-519, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36525340

RESUMO

ABSTRACT: Emerging monoclonal antibody therapies are assuming greater importance in the management of severe and refractory forms of immunity-driven and oncological disorders. However, some have been found to induce adverse ocular events (AOEs) leading to discontinuation of treatment or additional multidisciplinary management. We present the current knowledge concerning AOEs associated with 3 monoclonal antibody therapies: dupilumab, tralokinumab, and belantamab mafodotin. We examine the manifestations of their AOEs, proposed pathophysiological mechanisms, and current treatment recommendations. We identified and reviewed all studies for dupilumab, tralokinumab, and belantamab mafodotin using the keywords "dupilumab," "tralokinumab," "belantamab mafodotin," "conjunctivitis," and "keratopathy" from January 2016 to November 2021. Conjunctivitis was the most frequently reported AOE in patients with atopic dermatitis receiving dupilumab or tralokinumab. Mild cases were managed with warm compresses for associated meibomian gland dysfunction, artificial tears, and antihistamine/mast cell stabilizer eye drops. In more severe cases, additional anti-inflammatory therapy, with corticosteroid eye drops or ointments, or topical calcineurin inhibitors-such as tacrolimus or ciclosporin-were required. Patients with resistant or refractory multiple myeloma treated with belantamab mafodotin often developed keratopathy, which could necessitate contact lens fitting, or for cycles of belantamab mafodotin to be delayed.


Assuntos
Anticorpos Monoclonais , Conjuntivite , Humanos , Incidência , Anticorpos Monoclonais/efeitos adversos , Conjuntivite/induzido quimicamente , Soluções Oftálmicas/efeitos adversos
9.
Eye (Lond) ; 37(12): 2511-2517, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36539601

RESUMO

OBJECTIVE: To provide an insight into trends in corneal cross-linking (CXL) practice in the UK, including criteria for progression of corneal ectasia, identification of patients for CXL, the CXL procedure itself and post-operative management. METHODS: All ophthalmologist members of the UK Cross-linking (UK-CXL) Consortium were invited to complete an online survey about CXL practice for the year 2019. The data collected was anonymised by site and analysed with descriptive statistics. RESULTS: Responses were received from 16 individual CXL centres (16/38; 42% response rate) and the data represented ~2,000 CXL procedures performed in the UK in 2019. The commonest indication for CXL was progressive keratoconus. Between centres, there were variations in diagnostic evaluation, patient selection for CXL, the CXL procedure and the pre- and post-operative monitoring of patients. CONCLUSION: Consistent with the wide number of CXL treatment techniques described in the published literature world-wide, variations in the monitoring of corneal ectasia, indications for CXL, CXL practice and post-CXL follow-up were found to exist between UK-based CXL centres.


Assuntos
Ceratocone , Fotoquimioterapia , Humanos , Fármacos Fotossensibilizantes/uso terapêutico , Crosslinking Corneano , Riboflavina/uso terapêutico , Raios Ultravioleta , Dilatação Patológica/tratamento farmacológico , Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/diagnóstico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Reino Unido , Topografia da Córnea
10.
Int J Ophthalmol ; 16(7): 1084-1092, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37465507

RESUMO

AIM: To evaluate corneal astigmatic outcomes of femtosecond laser-assisted arcuate keratotomies (FAKs) combined with femtosecond-laser assisted cataract surgery (FLACS) over 12mo follow-up. METHODS: Totally 145 patients with bilateral cataracts and no ocular co-morbidities were recruited to a single-centre, single-masked, prospective randomized controlled trial (RCT) comparing two monofocal hydrophobic acrylic intraocular lenses. Eyes with corneal astigmatism (CA) of >0.8 dioptres (D) received unpaired, unopened, surface penetrating FAKs at the time of FLACS. Visual acuity, subjective refraction and Scheimpflug tomography were recorded at 1, 6, and 12mo. Alpins vectoral analyses were performed. RESULTS: Fifty-one patients (61 eyes), mean age 68.2±9.6y [standard deviation (SD)], received FAKs. Sixty eyes were available for analysis, except at 12mo when 59 attended. There were no complications due to FAKs. Mean pre-operative CA was 1.13±0.20 D. There was a reduction of astigmatism at all post-operative visits (residual CA 1mo: 0.85±0.42 D, P=0.0001; 6mo: 0.86±0.35 D, P=0001; and 12mo: 0.90±0.39, P=0.0001). Alpins indices remained stable over 12mo. Overall, the cohort was under-corrected at all time points. At 12mo, 61% of eyes were within ±15 degrees of pre-operative astigmatic meridian. CONCLUSION: Unpaired unopened penetrating FAKs combined with on-axis phacoemulsification are safe but minimally effective. CA is largely under-corrected in this cohort using an existing unmodified nomogram. The effect of arcuate keratotomies on CA remained stable over 12mo.

11.
Eye (Lond) ; 37(3): 440-445, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35115718

RESUMO

BACKGROUND/OBJECTIVES: During the COVID-19, elective cataract surgery (CS) was significantly curtailed. We investigated whether consequent reduction of micro-surgical skills practice might lead to higher operative complications. METHODS: Single-centre, electronic note review of consecutive patients undergoing CS during three periods: 1st February 2019 to 13th January 2020 (P1) prior to pandemic; 3rd June 2020 to 11th January 2021 after 1st lockdown (P2); and 25th January to 30th July 2021 (P3) after/during second lockdown. RESULTS: 2276 operations occurred during P1, 999 during P2, 846 during P3. During P1, posterior capsular rupture (PCR) rate was 1.67%, similar to P2 (1.30%, p = 0.54), but lower than P3 (3.55%, p = 0.002). There was no difference in PCR risk percentage scores between routine and PCR cases during P1 (1.90% vs 2.03%, p = 0.83), P2 (2% vs 2.18%, p = 0.18), or P3 (1.87% vs. 2.71%, p = 0.08). During P2 and P3, there was a higher rate of cystoid macular oedema (CMO) compared with P1 (4.9% and 6.86% vs. 1.93%, p = 0.0001), with no differences in proportion of diabetics or cases with CMO in combination with PCR. There was no difference in surgeons grade experiencing PCR. CONCLUSIONS: In P3 following 9 months of curtailed elective CS, PCR rates were increased across all surgeon grades, occurring in cases with similar risk percentage scores. CMO rates were increased during COVID and not related to proportion of diabetics or increased PCR rates. The reduction in elective CS during the pandemic was associated with more complications, perhaps due to attenuation of microsurgical skills.


Assuntos
COVID-19 , Catarata , Edema Macular , Humanos , Edema Macular/etiologia , Pandemias , COVID-19/complicações , Controle de Doenças Transmissíveis , Catarata/complicações
12.
Eye (Lond) ; 37(18): 3751-3756, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37277612

RESUMO

BACKGROUND: To compare productivity of National Health Service cataract lists performing unilateral cataract (UC) surgery vs Immediate Sequential Bilateral Cataract Surgery (ISBCS). METHODS: Five 4-hour lists with ISBCS cases and five with UC were observed using time and motion studies (TMS). Individual tasks and timings of each staff member in theatre was recorded by two observers. All operations were performed by consultant surgeons under local anaesthesia (LA). RESULTS: Median number of eyes operated per 4-hour list was 8 (range 6-8) in the ISBCS group and 5 (5-7) in the UC group (p = 0.028). Mean total theatre time (defined as time between the entry of the first patient and the exit of the last patient from theatre) was 177.12 (SD 73.62) minutes in the ISBCS group and 139.16 (SD 47.73) minutes in the UC group (p = 0.36). Mean time to complete two consecutive unilateral cataract surgery operations was 48.71 minutes compared to 42.23 minutes for a single ISBCS case (13.30% time saved). Based on our collected TMS data, a possible 5 consecutive ISBCS cases and 1 UC (total 11 cataract surgeries) could be performed during a four-hour theatre session, with a theatre utilisation quotient of 97.20%, contrasting to nine consecutive UC, with a theatre utilisation quotient of 90.40%. DISCUSSION: Performing consecutive ISBCS cases under LA on routine cataract surgery lists can increase surgical efficiency. TMS are a useful way to investigate surgical productivity and test theoretical models for efficiency improvements.


Assuntos
Extração de Catarata , Catarata , Humanos , Medicina Estatal , Estudos de Tempo e Movimento , Olho
13.
Eye (Lond) ; 36(9): 1761-1766, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34363047

RESUMO

OBJECTIVES: Cataract surgeons may periodically take time away from operating which can lead to skills fade. There is a paucity of research investigating the experiences of returning cataract surgeons and how different individual circumstances impact on their return. Our aim was to investigate the subjective experiences of UK ophthalmologists simultaneously returning to surgery following the nationwide elective surgical hiatus due to the Covid-19 pandemic. METHODS: An online survey was nationally distributed between 01/09/2020 and 29/10/2020 to registered UK ophthalmologists. Participants indicating a surgical hiatus of 8 weeks or more were included. RESULTS: 232 of 264 responses were analysed. Covid-19 was the most frequent reason for a surgical hiatus (median 15 weeks). Perceived operating difficulties were found in 29.1%. Transient anxiety (51.7%), reduced confidence, and perceived increased surgical time were commonplace. Trainees and females were more likely to encounter negative experiences (p < 0.001) and barriers to resource accessibility. Eyesi® and online videos were the most available and accessed pre-return resources. Childcare was five times more likely to present as a barrier to resource access for females than males. CONCLUSIONS: Technical skills fade such as capsulorhexis difficulties were commonly perceived by trainee surgeons in addition to transient anxiety, reported in more than half of all surgeons following a hiatus as short as 8 weeks. Eyesi® simulation offers the potential to negate technical de-skilling. Few had formal return plans or awareness of RCOphth guidance. We believe there is scope for more specialised and targeted support for future returning cataract surgeons thereby optimising patient care.


Assuntos
COVID-19 , Catarata , COVID-19/epidemiologia , Catarata/epidemiologia , Competência Clínica , Feminino , Humanos , Masculino , Pandemias , Reino Unido/epidemiologia
14.
Eye (Lond) ; 35(9): 2482-2498, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33927353

RESUMO

The aim of this review was to discuss frequently encountered themes such as cataract surgery in presence of age-related macular degeneration (AMD), dementia, Immediate Sequential Bilateral Cataract Surgery (ISBCS), discussing non-standard intraocular lens (IOL) options during consultation in the National Health Services (NHS) and the choice of the biometric formulae based on axial length. Individual groups of authors worked independently on each topic. We found that cataract surgery does improve visual acuity in AMD patients but the need for cataract surgery should be individualised. In patients with dementia, cataract surgery should be considered 'sooner rather than later' as progression may prevent individuals presenting for surgery. This should be planned after discussion of patients' best interests with any carers; multifocal IOLs are not proven to be the best option in these patients. ISBCS gives comparable outcomes to delayed sequential surgeries with a low risk of bilateral endophthalmitis and it can be cost-saving and efficient. Patients are entitled to know all suitable IOL options that can improve their quality of life. Deliberately withholding this information or pressuring patients to choose a non-standard IOL is inappropriate. However, one should be mindful of the not spending inappropriate amounts of time discussing these in the NHS setting which may affect care of other NHS patients. Evidence suggests Hoffer Q, Haigis, Hill-RBF and Kane formulae for shorter eyes; Barrett Universal II (BU II), Holladay II, Haigis and Kane formulae for longer eyes and BU II, Hill-RBF and Kane formulae for medium axial length eyes.


Assuntos
Catarata , Lentes Intraoculares , Biometria , Humanos , Implante de Lente Intraocular , Recidiva Local de Neoplasia , Óptica e Fotônica , Qualidade de Vida , Refração Ocular , Estudos Retrospectivos
15.
Br J Ophthalmol ; 105(5): 631-638, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32699049

RESUMO

AIMS: To report 12-month outcomes of randomised controlled trial comparing conventional phacoemulsification surgery (CPS) with femtosecond laser-assisted cataract surgery (FLACS). METHODS: This was a single-centre, prospective single-masked randomised case-controlled trial. Four hundred patients were randomised to CPS or FLACS with the LenSx platform (Alcon Laboratories Inc.). Visual acuity, refraction, central corneal thickness, endothelial cell loss (ECL), adverse events and quality of life outcomes, using EuroQOL 5-dimensions (EQ-5D-3 L) and cataract surgery patient-reported outcome measures (PROMs) questionnaires (Cat-PROM5), were recorded. RESULTS: Two hundred and thirty four patients (58.5%) attended 12-month follow-up (116 FLACS, 118 CPS). Mean LogMAR unaided distance visual acuity) (±SD) was 0.12 (0.18) with FLACS and 0.13 (0.19) with CPS (p=0.68; 95% Confidence Interval [CI]-0.06,0.04). Mean spherical equivalent (SE) refraction was -0.1±0.6 diopters (D) with FLACS and -0.2±0.6 D with CPS (p=0.44; 95% CI -0.09, 0.21). Mean corrected distance visual acuity (±SD) was -0.01 (0.1) with FLACS and 0(0.1) with CPS (p=0.45; 95% CI -0.04,0.02). Two patients per group underwent YAG laser capsulotomy for posterior capsular opacification (p=1). Mean ECL (per mm2±SD) was 301±320 with FLACS and 228±303 with CPS (p=0.07; 95% CI -7.26, 153.26). Mean Cat-PROM scores (±SD) were -5.5 (2.6) with FLACS and -5.8 (2.5) with CPS (p=0.3; 95% CI 0.31,1.01). EQ5-3DL mean index score (±SD) was 0.92 (0.13) with FLACS and 0.89 (0.14) with CPS (p=0.1; 95% CI -0.1, 0.01). Vector analysis comparing manual limbal relaxing incisions (LRIs) and intrastromal femtosecond laser-assisted astigmatic keratotomies (iFAKs) showed a greater correction index (p=0.02; 95% CI 0.06 to 0.60) and smaller difference vector (p=0.046; 95% CI -0.54, -0.01) with iFAK. CONCLUSIONS: There were no differences in vision, refraction, adverse postoperative events or PROMs between FLACS and CPS groups at 12 months. iFAKs may provide more effective astigmatic correction compared to LRIs, 12 months postoperatively.


Assuntos
Terapia a Laser/métodos , Facoemulsificação/métodos , Qualidade de Vida , Refração Ocular/fisiologia , Acuidade Visual , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Método Simples-Cego
16.
Eur J Ophthalmol ; 30(5): 840-855, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32515220

RESUMO

AIM: To review published literature concerning cataract surgery and dry eye disease (DED). METHODS: A search was undertaken using the following: PubMed (all years), Web of Science (all years), Ovid MEDLINE(R) (1946 to 12 December 2019), Ovid MEDLINE(R) Daily Update 10 December 2019, MEDLINE and MEDLINE non-indexed items, Embase (1974-2019, week 49), Ovid MEDLINE (R) and Epub Ahead of Print, In-Process and Other Non-Indexed Citations and Daily (1946 to 12 December 2019), CENTRAL (including Cochrane Eyes and Vision Trials Register; Cochrane Library: Issue 12 of 12 December 2019), metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and WHO International Clinical Trials Registry Platform (www.who.int/ictrp/search/en). Search terms included 'cataract surgery', 'phacoemulsification' and 'cataract extraction', combined with 'dry eyes' and 'ocular surface'. Relevant in-article references not returned in our searches were also considered. RESULTS: Publications identified included systematic reviews, meta-analysis, randomized controlled trials, cohort studies, case series and laboratory-based studies. Published data highlighting the burden of DED both prior and following cataract surgery were reviewed as well as studies highlighting the effects of cataract surgery on the ocular surface, intra-operative measures to reduce deleterious effects on the ocular surface and current evidence on the management options of post-operative DED. CONCLUSIONS: DED is common and can be exacerbated by cataract surgery. Ophthalmologists need to assess for pre-existing DED and instigate treatment before surgery; be aware of reduced accuracy of measurements for surgical planning in the presence of DED; limit intra-operative surgical factors damaging to the ocular surface; and consider management to reduce DED post-operatively.


Assuntos
Extração de Catarata/efeitos adversos , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/fisiopatologia , Humanos
17.
Eur J Ophthalmol ; 30(5): 823-839, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31387387

RESUMO

PURPOSE: To review the published scientific literature concerning clinical and material degradations of intraocular lenses after implantation in cataract surgery. METHODS: A search was undertaken using the following databases: CENTRAL (including Cochrane Eyes and Vision Trials Register; The Cochrane Library: Issue 2 of 12 February 2019), Ovid MEDLINE (R) without Revisions (1996 to February week 2, 2019), Ovid MEDLINE (R) (1946 to February week 2, 2019), Ovid MEDLINE (R) Daily Update 19 February 2019, MEDLINE and MEDLINE non-indexed items, Embase (1980-2019, week 7), Embase (1974-2019, 19 February), Ovid MEDLINE (R) and Epub Ahead of Print, in-Process & Other Non-Indexed Citations and Daily (1946 to 19 February 2019), Web of Science (all years), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and the WHO International Clinical Trials Registry Platform (www.who.int/ictrp/search/en). Only published articles in English were selected. Search terms/keywords included 'IOL' or 'intraocular lens', combined with 'opacification', degradation, glistenings, nanoglistenings, whitening, transmittance, light scatter, discolouration/discoloration, performance, quality, material, biocompatibility, calcification, explantation and ultraviolet/UV radiation. Relevant in-article references not returned in our searches were also considered. RESULTS: After review of the available articles, the authors included 122 publications in this review, based on the quality of their methodology and their originality. The studies included in this review were randomized controlled trials, cohort studies, case-controlled studies, case series, case reports, laboratory studies and review papers. Differing material degradations of intraocular lenses have been described and their associated pathophysiology studied. Reported anomalies include photochemical alterations, water vacuoles, internal and surface calcific deposits, surface coatings and discolouration. The nature of such changes has been shown to depend on the type of intraocular lenses material used and/or manufacturing processes and storage conditions employed. Changes in the intraocular lens can also be influenced by surgical technique, coexisting ocular pathologies and topical and systemic medications. The clinical significance of these degradations is variable, with some resulting in significant visual disturbance and the need for intraocular lens explantation and others producing only minimal visual impairments. Failure to recognize the precise nature of the problem may lead to unnecessary laser capsulotomy procedures. CONCLUSION: Clinical degradations of intraocular lenses are uncommon but have been reported following the implantation of intraocular lenses made of differing biomaterials. Their correct identification and thorough investigation to determine the underlying cause is necessary for optimal patient management and the prevention of such problems. Choosing a lens made of a particular material may be important in patients with certain ocular conditions.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Falha de Prótese/etiologia , Materiais Biocompatíveis , Humanos , Polímeros
18.
BMJ Open Ophthalmol ; 5(1): e000426, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32617415

RESUMO

OBJECTIVE: To test a hypothesis that operating room (OR) productivity in the National Health Service (NHS) can be improved with the introduction of immediately sequential bilateral cataract surgery (ISBCS). METHODS AND ANALYSIS: Previously published time and motion data of 140 unilateral cataract surgeries conducted at five different NHS locations were reanalysed to construct a hypothetical model where only ISBCS (±one unilateral case) were conducted while maintaining time durations of all key tasks previously studied. Possible time efficiency savings were calculated for the ISBCS model and percentage increases in numbers of eyes operated per 4-hour theatre session calculated. Gains in efficiency were correlated with factors from the baseline data to predict which settings could improve efficiency most by undertaking ISBCS. RESULTS: Based on remodelling our time and motion study (TMS) data as hypothetical ISBCS cases, we could expect a mean 16% reduction (range 9.8%-17.8%) in the time taken for two cataract operations, translating into a mean 54% improvement (range 38%-67%) in number of cases currently performed per list and an 18% improvement (range 9%-28%) even if the number of unilateral cases per list had been fully maximised. An average number of four ISBCS cases per list (range 3-6) were required to achieve sufficient time savings to allow an extra unilateral surgery to be conducted. CONCLUSION: The introduction of routine ISBCS has the potential to improve the productivity of cataract surgery within the NHS, with efficiencies being possible in both high-volume and low-volume surgical models.

19.
Eur J Ophthalmol ; 30(3): 417-429, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31801354

RESUMO

PURPOSE: Review scientific literature concerning femtosecond laser-assisted cataract surgery. METHODS: Following databases were searched: CENTRAL (Cochrane Eyes and Vision Trials Register; Cochrane Library: Issue 2 of 12, June 2019), Ovid MEDLINE® without Revisions (1996 to June 2019), Ovid MEDLINE® (1946 to June 2019), Ovid MEDLINE® Daily Update June 2019, MEDLINE and MEDLINE Non-Indexed Items, Embase (1980-2019), Embase (1974 to June 2019), Ovid MEDLINE® and Epub Ahead of Print, in-Process & Other Non-Indexed Citations and Daily (1946 to June 2019), Web of Science (all years), the metaRegister of Controlled Trials ( www.controlled-trials.com ), ClinicalTrials.gov ( www.clinicaltrial.gov ) and World Health Organization International Clinical Trials Registry Platform ( www.who.int/ictrp/search/en ). Search terms/keywords included 'Femtosecond laser' combined with 'cataract', 'cataract surgery'. RESULTS: Based on quality of their methodology and their originality, 121 articles were reviewed, including randomised controlled trials, cohort studies, case-controlled studies, case series, case reports and laboratory studies. Each step of the femtosecond laser-assisted cataract surgery procedure (corneal incisions, arcuate keratotomies, capsulotomy and lens fragmentation) has been discussed with relevance to published outcomes, as well as complication rates of femtosecond laser-assisted cataract surgery, and what we can learn from the larger studies/meta-analyses and the economics of femtosecond laser-assisted cataract surgery within different healthcare settings. CONCLUSION: Studies suggest that the current clinical outcomes of femtosecond laser-assisted cataract surgery are not different to conventional phacoemulsification surgery and it is not cost effective when compared with conventional phacoemulsification surgery. In its current technological form, it is a useful surgical tool in specific complex cataract scenarios, but its usage has not been shown to translate into better clinical outcomes.


Assuntos
Extração de Catarata , Catarata/etiologia , Terapia a Laser/métodos , Extração de Catarata/economia , Extração de Catarata/métodos , Análise Custo-Benefício , Bases de Dados Factuais , Humanos , Terapia a Laser/economia , Facoemulsificação/métodos , Resultado do Tratamento , Acuidade Visual/fisiologia
20.
BMJ Open Ophthalmol ; 5(1): e000399, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32154371

RESUMO

AIMS: To compare the characteristics of glistenings and forward light scatter between the Alcon Acrysof SN60WF and Santen Eternity Natural Uni NW-60 intraocular lenses (IOLs). METHODS: Five Acrysof SN60WF and five Eternity Natural Uni NW-60 IOLs were studied. All IOLs were single piece blue blockers with the same dioptric power (20D) and optic diameter (6.0 mm). Glistenings were induced by a thermal accelerated ageing process. Glistenings were objectively quantified using bespoke image processing software. The angular distribution of forward light scatter was measured using an optical bench system and the straylight parameter calculated from the light scatter function. RESULTS: The median increase in the number of glistenings was 15 and 525 for the Eternity and Acrysof IOLs, respectively, which was statistically significantly different (p=0.012). Median glistenings diameter was 23.8 µm (Acrysof) and 32.8 µm (Eternity). Four (80%) of the Acrysof lenses had straylight values higher than a 20-year-old CIE standard glare observer and in two cases the straylight exceeded that of the 70-year-old CIE standard glare observer. None of the Eternity lenses had straylight values that exceeded the value for the 20-year-old CIE standard glare observer. CONCLUSIONS: The Eternity Natural Uni NW-60 IOLs resisted the induction of glistenings more than the Acrysof SN60WF IOLs. Although the Acrysof IOLs developed smaller glistenings than the Eternity IOLs, there were sufficient numbers to produce a higher straylight parameter.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA