Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 114(51): 13513-13518, 2017 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-29203653

RESUMO

Micronutrient deficiencies such as those of vitamin A and iron affect a third of the world's population with consequences such as night blindness, higher child mortality, anemia, poor pregnancy outcomes, and reduced work capacity. Many efforts to prevent or treat these deficiencies are hampered by the lack of adequate, accessible, and affordable diagnostic methods that can enable better targeting of interventions. In this work, we demonstrate a rapid diagnostic test and mobile enabled platform for simultaneously quantifying iron (ferritin), vitamin A (retinol-binding protein), and inflammation (C-reactive protein) status. Our approach, enabled by combining multiple florescent markers and immunoassay approaches on a single test, allows us to provide accurate quantification in 15 min even though the physiological range of the markers of interest varies over five orders of magnitude. We report sensitivities of 88%, 100%, and 80% and specificities of 97%, 100%, and 97% for iron deficiency (ferritin <15 ng/mL or 32 pmol/L), vitamin A deficiency (retinol-binding protein <14.7 µg/mL or 0.70 µmol/L) and inflammation status (C-reactive protein >3.0 µg/mL or 120 nmol/L), respectively. This technology is suitable for point-of-care use in both resource-rich and resource-limited settings and can be read either by a standard laptop computer or through our previously developed NutriPhone technology. If implemented as either a population-level screening or clinical diagnostic tool, we believe this platform can transform nutritional status assessment and monitoring globally.


Assuntos
Anemia Ferropriva/sangue , Técnicas de Diagnóstico Molecular/métodos , Testes Imediatos , Deficiência de Vitamina A/sangue , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Ferritinas/sangue , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Imunoensaio/normas , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/normas , Proteínas de Ligação ao Retinol/metabolismo , Smartphone
2.
Anal Chem ; 89(9): 5095-5100, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28388030

RESUMO

The quantification of analyte concentrations using lateral flow assays is a low-cost and user-friendly alternative to traditional lab-based assays. However, sandwich-type immunoassays are often limited by the high-dose hook effect, which causes falsely low results when analytes are present at very high concentrations. In this paper, we present a reaction kinetics-based technique that solves this problem, significantly increasing the dynamic range of these devices. With the use of a traditional sandwich lateral flow immunoassay, a portable imaging device, and a mobile interface, we demonstrate the technique by quantifying C-reactive protein concentrations in human serum over a large portion of the physiological range. The technique could be applied to any hook effect-limited sandwich lateral flow assay and has a high level of accuracy even in the hook effect range.


Assuntos
Proteína C-Reativa/análise , Imunoensaio/métodos , Anticorpos/imunologia , Proteína C-Reativa/imunologia , Ouro/química , Humanos , Cinética , Nanopartículas Metálicas/química , Fenômenos Físicos
3.
Nano Lett ; 15(2): 1414-20, 2015 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-25625877

RESUMO

Direct measurements of particle-surface interactions are important for characterizing the stability and behavior of colloidal and nanoparticle suspensions. Current techniques are limited in their ability to measure pico-Newton scale interaction forces on submicrometer particles due to signal detection limits and thermal noise. Here we present a new technique for making measurements in this regime, which we refer to as nanophotonic force microscopy. Using a photonic crystal resonator, we generate a strongly localized region of exponentially decaying, near-field light that allows us to confine small particles close to a surface. From the statistical distribution of the light intensity scattered by the particle we are able to map out the potential well of the trap and directly quantify the repulsive force between the nanoparticle and the surface. As shown in this Letter, our technique is not limited by thermal noise, and therefore, we are able to resolve interaction forces smaller than 1 pN on dielectric particles as small as 100 nm in diameter.


Assuntos
Microscopia/métodos , Nanopartículas , Propriedades de Superfície
4.
J Lightwave Technol ; 33(16): 3494-3502, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26855473

RESUMO

Nanoparticles are quickly becoming commonplace in many commercial and industrial products, ranging from cosmetics to pharmaceuticals to medical diagnostics. Predicting the stability of the engineered nanoparticles within these products a priori remains an important and difficult challenge. Here we describe our techniques for measuring the mechanical interactions between nanoparticles and surfaces using near-field light scattering. Particle-surface interfacial forces are measured by optically "pushing" a particle against a reference surface and observing its motion using scattered near-field light. Unlike atomic force microscopy, this technique is not limited by thermal noise, but instead takes advantage of it. The integrated waveguide and microfluidic architecture allow for high-throughput measurements of about 1000 particles per hour. We characterize the reproducibility of and experimental uncertainty in the measurements made using the NanoTweezer surface instrument. We report surface interaction studies on gold nanoparticles with 50 nm diameters, smaller than previously reported in the literature using similar techniques.

5.
EBioMedicine ; 42: 504-510, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30885726

RESUMO

BACKGROUND: Iron deficiency (ID) and anaemia are major health concerns, particularly in young children. Screening for ID based on haemoglobin (Hb) concentration alone has been shown to lack sensitivity and specificity. The American Academy of Pediatrics (AAP) recommends soluble transferrin receptor (sTfR) as a promising approach to screen for iron deficiency. However, in most settings, assessment of iron status requires access to centralized laboratories. There is an urgent need for rapid, sensitive, and affordable diagnostics for sTfR at the point-of-care. METHODS: An immunochromatographic assay-based point-of-care screening device was developed for rapid quantification of sTfR from a drop of serum within a few minutes. Performance optimization of the assay was done in sTfR-spiked buffer and commercially available sTfR calibrator, followed by a small-scale proof-of-concept validation with archived serum samples. FINDINGS: On preliminary testing with archived serum samples and comparison with Ramco ELISA, a correlation of 0.93 (P < 0.0001) was observed, demonstrating its potential for point-of-care assessment of iron status. INTERPRETATION: The analytical performance of the point-of-care sTfR screening device indicates the potential for application in home-use test kits and field settings, especially in low- and middle-income settings. An added advantage of sTfR quantification in combination with our previously reported serum ferritin diagnostics is in integration of Cook's equation as a quantitative and minimally-invasive indicator of total body iron stores. FUND: Thrasher Research Fund (Early Career Award #13379), NIH R03 EB 023190, NSF grant #1343058, and Nutrition International (project #10-8007-CORNE-01).


Assuntos
Anemia Ferropriva/sangue , Anemia Ferropriva/diagnóstico , Testes Imediatos , Receptores da Transferrina/sangue , Testes Diagnósticos de Rotina/instrumentação , Testes Diagnósticos de Rotina/métodos , Humanos , Nanotecnologia , Fitas Reagentes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Biosens Bioelectron ; 99: 115-121, 2018 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-28750335

RESUMO

Iron deficiency (ID) is an urgent public health problem that has devastating effects on maternal and child health. However, due to poor access and affordability, screening and diagnosis for ID is often limited to proxy hemoglobin measurements alone. Here, we report the development and validation of ironPhone, a mobile-device coupled portable diagnostics for quantification of serum ferritin concentrations, an iron status biomarker, within a few minutes, from a drop of fingerprick blood. The ironPhone diagnostic platform comprises of a smartphone accessory, an app, and a disposable lateral flow immunoassay test strip to quantify serum ferritin. For initial validation in the lab, we optimized and evaluated the performance of ironPhone with known ferritin concentrations in spiked buffer and serum samples. Following lab validation, we performed a human validation by collecting fingerprick whole blood samples from 20 participants to assess iron status using ironPhone and compared the results with the laboratory standard IMMULITE 2000 analyzer. Findings from the ironPhone for the buffer and spiked serum samples provided a calibration curve with R2 values of 0.97 (n=27) and 0.93 (n=12), respectively. On comparison with the laboratory standard IMMULITE analyzer in whole blood samples, a correlation of 0.92 (P<0.0001) was observed with a sensitivity of over 90% for predicting ID (ferritin<15.0µg/L) via the ironPhone, demonstrating its promise for iron status assessment at the point-of-care.


Assuntos
Técnicas Biossensoriais , Ferritinas/sangue , Ferro/sangue , Telefone Celular , Ferritinas/isolamento & purificação , Humanos , Ferro/isolamento & purificação
7.
JMIR Hum Factors ; 5(1): e9, 2018 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-29490894

RESUMO

BACKGROUND: Technological advances in personal informatics allow people to track their own health in a variety of ways, representing a dramatic change in individuals' control of their own wellness. However, research regarding patient interpretation of traditional medical tests highlights the risks in making complex medical data available to a general audience. OBJECTIVE: This study aimed to explore how people interpret medical test results, examined in the context of a mobile blood testing system developed to enable self-care and health management. METHODS: In a preliminary investigation and main study, we presented 27 and 303 adults, respectively, with hypothetical results from several blood tests via one of the several mobile interface designs: a number representing the raw measurement of the tested biomarker, natural language text indicating whether the biomarker's level was low or high, or a one-dimensional chart illustrating this level along a low-healthy axis. We measured respondents' correctness in evaluating these results and their confidence in their interpretations. Participants also told us about any follow-up actions they would take based on the result and how they envisioned, generally, using our proposed personal health system. RESULTS: We find that a majority of participants (242/328, 73.8%) were accurate in their interpretations of their diagnostic results. However, 135 of 328 participants (41.1%) expressed uncertainty and confusion about their ability to correctly interpret these results. We also find that demographics and interface design can impact interpretation accuracy, including false confidence, which we define as a respondent having above average confidence despite interpreting a result inaccurately. Specifically, participants who saw a natural language design were the least likely (421.47 times, P=.02) to exhibit false confidence, and women who saw a graph design were less likely (8.67 times, P=.04) to have false confidence. On the other hand, false confidence was more likely among participants who self-identified as Asian (25.30 times, P=.02), white (13.99 times, P=.01), and Hispanic (6.19 times, P=.04). Finally, with the natural language design, participants who were more educated were, for each one-unit increase in education level, more likely (3.06 times, P=.02) to have false confidence. CONCLUSIONS: Our findings illustrate both promises and challenges of interpreting medical data outside of a clinical setting and suggest instances where personal informatics may be inappropriate. In surfacing these tensions, we outline concrete interface design strategies that are more sensitive to users' capabilities and conditions.

8.
JMIR Hum Factors ; 4(4): e29, 2017 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-29162559

RESUMO

BACKGROUND: In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. OBJECTIVE: The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. METHODS: An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. RESULTS: Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. CONCLUSIONS: This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests that the reader is usable among and can benefit a wide group of potential users, including in POC contexts. Generally, the methodology of this study demonstrates the importance of testing these types of systems with potential users and exemplifies how iterative design processes can be employed by multidisciplinary research teams to produce compelling technological solutions.

9.
Phys Rev Appl ; 62016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30417030

RESUMO

The behavior of a nanoparticle in solution depends strongly on the particle's physical and chemical characteristics, most notably the particle size and the surface properties. Accurately characterizing these properties is critical for quality control in a wide variety of industries. To understand a complex and polydisperse nanoparticle suspension, however, ensemble averaging is not sufficient, and there is a great need for direct measurements of size and surface properties at the individual nanoparticle level. In this work, we present an analysis technique for simultaneous characterization of particle-surface interactions and size using near-field light scattering and verify it using Brownian-dynamics simulations. Using a nanophotonic waveguide, single particles can be stably held near the waveguide's surface by strongly localized optical forces. By tracking the dynamic 3D motion of the particle under the influence of these forces using an optical microscope, it is possible to extract the particle-surface interaction forces, as well as to estimate the size and refractive index of the nanoparticle. Because of the strong light-scattering signal, this method is viable for high-throughput characterization of particles as small as 100 nm in only a few seconds each.

10.
Phys Rev E ; 93(6): 062139, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27415240

RESUMO

Here we measure the hindered diffusion of an optically confined nanoparticle in the direction normal to a surface, and we use this to determine the particle-surface interaction profile in terms of the absolute height. These studies are performed using the evanescent field of an optically excited single-mode silicon nitride waveguide, where the particle is confined in a height-dependent potential energy well generated from the balance of optical gradient and surface forces. Using a high-speed cmos camera, we demonstrate the ability to capture the short time-scale diffusion dominated motion for 800-nm-diam polystyrene particles, with measurement times of only a few seconds per particle. Using established theory, we show how this information can be used to estimate the equilibrium separation of the particle from the surface. As this measurement can be made simultaneously with equilibrium statistical mechanical measurements of the particle-surface interaction energy landscape, we demonstrate the ability to determine these in terms of the absolute rather than relative separation height. This enables the comparison of potential energy landscapes of particle-surface interactions measured under different experimental conditions, enhancing the utility of this technique.


Assuntos
Nanopartículas/química , Poliestirenos/química , Difusão , Movimento (Física) , Tamanho da Partícula , Propriedades de Superfície
11.
Sci Rep ; 6: 28237, 2016 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-27301282

RESUMO

Vitamin B12 is necessary for formation of red blood cells, DNA synthesis, neural myelination, brain development, and growth. Vitamin B12 deficiency is often asymptomatic early in its course; however, once it manifests, particularly with neurological symptoms, reversal by dietary changes or supplementation becomes less effective. Access to easy, low cost, and personalized nutritional diagnostics could enable individuals to better understand their own deficiencies as well as track the effects of dietary changes. In this work, we present the NutriPhone, a mobile platform for the analysis of blood vitamin B12 levels in 15 minutes. The NutriPhone technology comprises of a smartphone accessory, an app, and a competitive-type lateral flow test strip that quantifies vitamin B12 levels. To achieve the detection of sub-nmol/L physiological levels of vitamin B12, our assay incorporates an innovative "spacer pad" for increasing the duration of the key competitive binding reaction and uses silver amplification of the initial signal. We demonstrate the efficacy of our NutriPhone system by quantifying physiologically relevant levels of vitamin B12 and performing human trials where it was used to accurately evaluate blood vitamin B12 status of 12 participants from just a drop (~40 µl) of finger prick blood.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Smartphone , Vitamina B 12/sangue , Humanos , Sistemas Automatizados de Assistência Junto ao Leito/economia , Deficiência de Vitamina B 12/diagnóstico
12.
Sci Rep ; 5: 12087, 2015 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-26160194

RESUMO

Biomolecular interactions, such as antibody-antigen binding, are fundamental to many biological processes. At present, most techniques for analyzing these interactions require immobilizing one or both of the interacting molecules on an assay plate or a sensor surface. This is convenient experimentally but can constrain the natural binding affinity and capacity of the molecules, resulting in data that can deviate from the natural free-solution behavior. Here we demonstrate a label-free method for analyzing free-solution interactions between a single influenza virus and specific antibodies at the single particle level using near-field optical trapping and light-scattering techniques. We determine the number of specific antibodies binding to an optically trapped influenza virus by analyzing the change of the Brownian fluctuations of the virus. We develop an analytical model that determines the increased size of the virus resulting from antibodies binding to the virus membrane with uncertainty of ± 1-2 nm. We present stoichiometric results of 26 ± 4 (6.8 ± 1.1 attogram) anti-influenza antibodies binding to an H1N1 influenza virus. Our technique can be applied to a wide range of molecular interactions because the nanophotonic tweezer can handle molecules from tens to thousands of nanometers in diameter.


Assuntos
Anticorpos Antivirais/química , Anticorpos Antivirais/imunologia , Reações Antígeno-Anticorpo/imunologia , Vírus da Influenza A Subtipo H1N1/química , Vírus da Influenza A Subtipo H1N1/imunologia , Nanotecnologia/métodos , Difusão Dinâmica da Luz/métodos , Pinças Ópticas , Coloração e Rotulagem/métodos
13.
Sci Rep ; 4: 6707, 2014 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-25330911

RESUMO

Chemical reactions can be described by an energy diagram along a reaction coordinate in which an activation barrier limits the rate at which reactants can be transformed into products. This reaction impedance can be overcome by reducing the magnitude of the barrier through the use of catalysis, increasing the thermal energy of the system, or through macroscopic mechanical processes. Here, we demonstrate direct molecular-scale control of a reaction through the precise application of opto-mechanical work. The method uses optical gradient forces generated in the evanescent field surrounding hybrid photonic-plasmonic structures to drive an otherwise unlikely adsorption reaction between proteins and carbon nanotubes. The adsorption of immunoglobulins on carbon nanotubes is used as a model reaction and investigated with an extended DLVO theory. The technique is also used to force a Förster resonance energy transfer between fluorophores on mismatched immunoglobulin proteins and is expected to lead to novel forms of chemical synthesis.


Assuntos
Adsorção , Imunoglobulinas/química , Nanotubos de Carbono/química , Proteínas/química , Catálise , Transferência Ressonante de Energia de Fluorescência , Fótons
14.
Lab Chip ; 14(17): 3159-64, 2014 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-24700127

RESUMO

The rapid expansion of mobile technology is transforming the biomedical landscape. By 2016 there will be 260 M active smartphones in the US and millions of health accessories and software "apps" running off them. In parallel with this have come major technical achievements in lab-on-a-chip technology leading to incredible new biochemical sensors and molecular diagnostic devices. Despite these advancements, the uptake of lab-on-a-chip technologies at the consumer level has been somewhat limited. We believe that the widespread availability of smartphone technology and the capabilities they offer in terms of computation, communication, social networking, and imaging will be transformative to the deployment of lab-on-a-chip type technology both in the developed and developing world. In this paper we outline why we believe this is the case, the new business models that may emerge, and detail some specific application areas in which this synergy will have long term impact, namely: nutrition monitoring and disease diagnostics in limited resource settings.


Assuntos
Telefone Celular , Dispositivos Lab-On-A-Chip , Diagnóstico , Humanos , Monitorização Fisiológica/instrumentação , Telemedicina
15.
Lab Chip ; 13(16): 3232-8, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-23784453

RESUMO

The mobile health market is rapidly expanding and portable diagnostics tools offer an opportunity to decrease costs and increase the availability of healthcare. Here we present a smartphone based accessory and method for the rapid colorimetric detection of pH in sweat and saliva. Sweat pH can be correlated to sodium concentration and sweat rate in order to indicate to users the proper time to hydrate during physical exercise and avoid the risk of muscle cramps. Salivary pH below a critical threshold is correlated with enamel decalcification, an acidic breakdown of calcium in the teeth. We conduct a number of human trials with the device on a treadmill to demonstrate the ability to monitor changes in sweat pH due to exercise and electrolyte intake and predict optimal hydration. Additionally, we perform trials to measure salivary pH over time to monitor the effects of diet on oral health risks.


Assuntos
Telefone Celular , Colorimetria/métodos , Atenção à Saúde/métodos , Saliva/química , Suor/química , Adulto , Biomarcadores/análise , Dieta , Eletrólitos/análise , Humanos , Masculino , Aplicativos Móveis , Atividade Motora , Saúde Bucal , Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA