Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Sensors (Basel) ; 24(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38894317

RESUMO

Over the past two decades, there has been extensive research into surveillance methods for the post-endovascular repair of abdominal aortic aneurysms, highlighting the importance of these technologies in supplementing or even replacing conventional image-screening modalities. This review aims to provide an overview of the current status of alternative surveillance solutions for endovascular aneurysm repair, while also identifying potential aneurysm features that could be used to develop novel monitoring technologies. It offers a comprehensive review of these recent clinical advances, comparing new and standard clinical practices. After introducing the clinical understanding of abdominal aortic aneurysms and exploring current treatment procedures, the paper discusses the current surveillance methods for endovascular repair, contrasting them with recent pressure-sensing technologies. The literature on three commercial pressure-sensing devices for post-endovascular repair surveillance is analyzed. Various pre-clinical and clinical studies assessing the safety and efficacy of these devices are reviewed, providing a comparative summary of their outcomes. The review of the results from pre-clinical and clinical studies suggests a consistent trend of decreased blood pressure in the excluded aneurysm sac post-repair. However, despite successful pressure readings from the aneurysm sac, no strong link has been established to translate these measurements into the presence or absence of endoleaks. Furthermore, the results do not allow for a conclusive determination of ongoing aneurysm sac growth. Consequently, a strong clinical need persists for monitoring endoleaks and aneurysm growth following endovascular repair.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Pressão Sanguínea/fisiologia , Pressão , Próteses e Implantes , Correção Endovascular de Aneurisma
2.
Sensors (Basel) ; 24(10)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38794049

RESUMO

Abdominal aortic aneurysm (AAA) is a dilation of the aorta artery larger than its normal diameter (>3 cm). Endovascular aneurysm repair (EVAR) is a minimally invasive treatment option that involves the placement of a graft in the aneurysmal portion of the aorta artery. This treatment requires multiple follow-ups with medical imaging, which is expensive, time-consuming, and resource-demanding for healthcare systems. An alternative solution is the use of wireless implantable sensors (WIMSs) to monitor the growth of the aneurysm. A WIMS capable of monitoring aneurysm size longitudinally could serve as an alternative monitoring approach for post-EVAR patients. This study has developed and characterised a three-coil inductive read-out system to detect variations in the resonance frequency of the novel Z-shaped WIMS implanted within the AAA sac. Specifically, the spacing between the transmitter and the repeater inductors was optimised to maximise the detection of the sensor by the transmitter inductor. Moreover, an experimental evaluation was also performed for different orientations of the transmitter coil with reference to the WIMS. Finally, the FDA-approved material nitinol was used to develop the WIMS, the transmitter, and repeater inductors as a proof of concept for further studies. The findings of the characterisation from the air medium suggest that the read-out system can detect the WIMS up to 5 cm, regardless of the orientation of the Z-shape WIMS, with the detection range increasing as the orientation approaches 0°. This study provides sufficient evidence that the proposed WIMS and the read-out system can be used for AAA expansion over time.


Assuntos
Aneurisma da Aorta Abdominal , Tecnologia sem Fio , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tecnologia sem Fio/instrumentação , Humanos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Próteses e Implantes , Desenho de Equipamento
3.
Sensors (Basel) ; 24(11)2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38894148

RESUMO

Birth asphyxia is a potential cause of death that is also associated with acute and chronic morbidities. The traditional and immediate approach for monitoring birth asphyxia (i.e., arterial blood gas analysis) is highly invasive and intermittent. Additionally, alternative noninvasive approaches such as pulse oximeters can be problematic, due to the possibility of false and erroneous measurements. Therefore, further research is needed to explore alternative noninvasive and accurate monitoring methods for asphyxiated neonates. This study aims to investigate the prominent ECG features based on pH estimation that could potentially be used to explore the noninvasive, accurate, and continuous monitoring of asphyxiated neonates. The dataset used contained 274 segments of ECG and pH values recorded simultaneously. After preprocessing the data, principal component analysis and the Pan-Tompkins algorithm were used for each segment to determine the most significant ECG cycle and to compute the ECG features. Descriptive statistics were performed to describe the main properties of the processed dataset. A Kruskal-Wallis nonparametric test was then used to analyze differences between the asphyxiated and non-asphyxiated groups. Finally, a Dunn-Sidák post hoc test was used for individual comparison among the mean ranks of all groups. The findings of this study showed that ECG features (T/QRS, T Amplitude, Tslope, Tslope/T, Tslope/|T|, HR, QT, and QTc) based on pH estimation differed significantly (p < 0.05) in asphyxiated neonates. All these key ECG features were also found to be significantly different between the two groups.


Assuntos
Asfixia Neonatal , Eletrocardiografia , Humanos , Eletrocardiografia/métodos , Recém-Nascido , Concentração de Íons de Hidrogênio , Asfixia Neonatal/diagnóstico , Asfixia Neonatal/fisiopatologia , Algoritmos , Estudos de Viabilidade , Gasometria/métodos , Análise de Componente Principal , Feminino , Masculino
4.
BMC Anesthesiol ; 23(1): 239, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37454135

RESUMO

OBJECTIVES: To develop and assess a system for shared ventilation using clinically available components to individualize tidal volumes. DESIGN: Evaluation and in vitro validation study SETTING: Ventilator shortage during the SARS-CoV-2 pandemic. PARTICIPANTS: The team consisted of physicians, bioengineers, computer programmers, and medical technology professionals. METHODS: Using clinically available components, a system of ventilation consisting of two ventilatory limbs was assembled and connected to a ventilator. Monitors for each limb were developed using open-source software. Firstly, the effect of altering ventilator settings on tidal volumes delivered to each limb was determined. Secondly, the impact of altering the compliance and resistance of one limb on the tidal volumes delivered to both limbs was analysed. Experiments were repeated three times to determine system variability. RESULTS: The system permitted accurate and reproducible titration of tidal volumes to each limb over a range of ventilator settings and simulated lung conditions. Alteration of ventilator inspiratory pressures, of respiratory rates, and I:E ratio resulted in very similar tidal volumes delivered to each limb. Alteration of compliance and resistance in one limb resulted in reproducible alterations in tidal volume to that test lung, with little change to tidal volumes in the other lung. All tidal volumes delivered were reproducible. CONCLUSIONS: We demonstrate the reliability of a shared ventilation system assembled using commonly available clinical components that allows titration of individual tidal volumes. This system may be useful as a strategy of last resort for Covid-19, or other mass casualty situations, where the need for ventilators exceeds supply.


Assuntos
COVID-19 , Humanos , Volume de Ventilação Pulmonar , COVID-19/terapia , Reprodutibilidade dos Testes , SARS-CoV-2 , Ventiladores Mecânicos , Respiração Artificial/métodos
5.
J Cardiovasc Electrophysiol ; 33(9): 2050-2061, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35924470

RESUMO

BACKGROUND: Irreversible electroporation has emerged as a new modality to overcome issues associated with other energy sources for cardiac ablation. Strong evidence on the optimal, effective, and selective voltage threshold is lacking for both in vitro and preclinical in vivo studies. The aim of this study is to examine the optimal threshold for selective cell ablation on cardiac associated cell types. METHODS: Conventional monophasic and biphasic pulses of different field strength were delivered in a monolayer culture system of cardiomyocytes, neurons, and adipocytes. The dynamics of cell death mechanisms were examined at different time points. RESULTS: Neurons exhibit higher susceptibility to electroporation and cell death at higher field strength of 1250 V/cm in comparison to cardiomyocytes. Cardiac adipocytes showed lower susceptibility to electroporation in comparison to other cell types. A significant proportion of cardiomyocytes recovered after 24 h postelectroporation, while neuronal cell death remained consistent but with a significant delayed cell death at a higher voltage threshold. Caspase 3/7 activity was observed in both cardiomyocytes and neurons, with a higher level of activity in cardiomyocytes in response to electroporation. Biphasic and monophasic pulses showed no significant difference in both cell types, and significantly lower cell death in neurons when inter pulse interval was reduced. CONCLUSIONS: This study presents important findings on the differences in the susceptibility of neurons and cardiomyocytes to irreversible electroporation. Cell type alone yielded selective and different dynamics in terms of the evolution and signaling mechanism of cell death in response to electroporation.


Assuntos
Ablação por Cateter , Eletroporação , Frequência Cardíaca , Humanos
6.
Int J Hyperthermia ; 39(1): 1179-1194, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36096484

RESUMO

BACKGROUND AND OBJECTIVES: Adrenocortical neoplasms are the main causes of secondary hypertension and related comorbidities including hypokalemia and cardiovascular diseases. Conventional techniques for the management of this condition are often invasive and not resolutive. Recent studies proposed microwave thermal ablation (MWA) to eradicate adrenocortical adenomas arising in proximity to sensitive structures. This study explores a new MWA approach to selectively direct the electromagnetic energy into the target and shield the surrounding tissues. The new solution relies on the anatomical and dielectric characteristics of the adrenal gland and the surrounding fat capsule. METHODS: A 3 D model of the adrenal gland is developed, and a cooled microwave applicator is placed parallel to the interface between the fat and adrenal tissue. Numerical simulations are conducted at 2.45 GHz accounting for two energy delivery settings, two orientations of the applicator and blood perfusion of the tissues. Ex vivo and in vivo ablation procedures are conducted on ovine adrenal glands. Histology analysis completes the experimental studies. RESULTS: Numerical results show asymmetric ablation profiles in ex vivo and in vivo conditions. The asymmetry ratio is influenced by the procedure settings and orientation of the applicator. Ablation zones obtained experimentally agree with those predicted by the numerical simulations. Histology analysis confirms irreversible cellular changes only in the adrenal tissue close to the applicator. CONCLUSIONS: The outcomes show that the dielectric contrast between the fat layer and tissue target can be a tool in MWA to shape ablation zones to protect the surrounding structures from excessive temperature increases.


Assuntos
Adenoma , Adenoma Adrenocortical , Ablação por Radiofrequência , Animais , Fígado/cirurgia , Micro-Ondas/uso terapêutico , Ovinos
7.
Int J Hyperthermia ; 39(1): 1264-1275, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36137605

RESUMO

PURPOSE: To assess the feasibility of delivering microwave ablation for targeted treatment of aldosterone producing adenomas using image-based computational models. METHODS: We curated an anonymized dataset of diagnostic 11C-metomidate PET/CT images of 14 patients with aldosterone producing adenomas (APA). A semi-automated approach was developed to segment the APA, adrenal gland, and adjacent organs within 2 cm of the APA boundary. The segmented volumes were used to implement patient-specific 3D electromagnetic-bioheat transfer models of microwave ablation with a 2.45 GHz directional microwave ablation applicator. Ablation profiles were quantitatively assessed based on the extent of the APA target encompassed by an ablative thermal dose, while limiting thermal damage to the adjacent normal adrenal tissue and sensitive critical structures. RESULTS: Across the 14 patients, adrenal tumor volumes ranged between 393 mm3 and 2,395 mm3. On average, 70% of the adrenal tumor volumes received an ablative thermal dose of 240CEM43, while limiting thermal damage to non-target structures, and thermally sparing 83.5-96.4% of normal adrenal gland. Average ablation duration was 293 s (range: 60-600 s). Simulations indicated coverage of the APA with an ablative dose was limited when the axis of the ablation applicator was not well aligned with the major axis of the targeted APA. CONCLUSIONS: Image-based computational models demonstrate the potential for delivering microwave ablation to APA targets within the adrenal gland, while limiting thermal damage to surrounding non-target structures.


Assuntos
Adenoma , Neoplasias das Glândulas Suprarrenais , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/cirurgia , Aldosterona , Simulação por Computador , Computadores , Humanos , Micro-Ondas/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
8.
Int J Hyperthermia ; 39(1): 584-594, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35435078

RESUMO

PURPOSE: Bio-effects following thermal treatments are a function of the achieved temperature profile in tissue, which can be estimated across tumor volumes with real-time MRI thermometry (MRIT). Here, we report on expansion of a previously developed small-animal microwave hyperthermia system integrated with MRIT for delivering thermal ablation to subcutaneously implanted tumors in mice. METHODS: Computational models were employed to assess suitability of the 2.45 GHz microwave applicators for delivering ablation to subcutaneous tumor targets in mice. Phantoms and ex-vivo tissues were heated to temperatures in the range 47-67 °C with custom-made microwave applicators for validating MRIT with the proton resonance frequency shift method against fiberoptic thermometry. HAC15 tumors implanted in nude mice (n = 6) were ablated in vivo and monitored with MRIT in multiple planes. One day post ablation, animals were euthanized, and excised tumors were processed for viability assessment. RESULTS: Average absolute error between temperatures from fiberoptic sensors and MRIT was 0.6 °C across all ex-vivo ablations. During in-vivo experiments, tumors with volumes ranging between 5.4-35.9 mm3 (mean 14.2 mm3) were ablated (duration: 103-150 s) to achieve 55 °C at the tumor boundary. Thermal doses ≥240 CEM43 were achieved across 90.7-98.0% of tumor volumes for four cases. Ablations were incomplete for remaining cases, attributed to motion-affected thermometry. Thermal dose-based ablative tumor coverage agreed with viability assessment of excised tumors. CONCLUSIONS: We have developed a system for delivering microwave ablation to subcutaneous tumors in small animals under MRIT guidance and demonstrated its performance in-vivo.


Assuntos
Neoplasias , Termometria , Animais , Imageamento por Ressonância Magnética/métodos , Camundongos , Camundongos Nus , Micro-Ondas/uso terapêutico , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia
9.
Sensors (Basel) ; 22(23)2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36502019

RESUMO

Recent studies have shown that ablation techniques have the potential to eradicate adrenal adenomas while preserving the functionalities of the adrenal gland and the surrounding anatomical structures. This study explores a new microwave ablation (MWA) approach operating at 5.8 GHz and using anatomical and dielectric characteristics of the target tissue to create directional heating patterns. Numerical simulations are executed in planar and 3D adrenal models, considering two energy doses. The numerical study is refined accounting for the vaporization of the tissue water content. Ex vivo experimental evaluations on porcine adrenal models complete the study. The numerical and experimental results show that spherical ablation zones are able to cover the target for both energy doses considered. Nonetheless, most of the non-targeted tissues can be preserved from excessive heating when low energy level is used. Numerical models accounting for water vaporization are capable to foresee the experimental temperature values. This study shows that the proposed MWA directional approach operating at 5.8 GHz can be considered for creating effective and selective ablation zones.


Assuntos
Técnicas de Ablação , Ablação por Radiofrequência , Animais , Suínos , Micro-Ondas , Técnicas de Ablação/métodos , Temperatura , Água , Fígado/cirurgia
10.
Sensors (Basel) ; 22(19)2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36236269

RESUMO

The electrical properties of many biological tissues are freely available from the INRC and the IT'IS databases. However, particularly in lower frequency ranges, few studies have investigated the optimal measurement protocol or the key confounders that need to be controlled, monitored, and reported. However, preliminary work suggests that the contact force of the measurement probe on the tissue sample can affect the measurements. The aim of this paper is to investigate the conductivity change due to the probe contact force in detail. Twenty ex vivo bovine heart samples are used, and conductivity measurements are taken in the Left Atrial Appendage, a common target for medical device developments. The conductivity measurements reported in this work (between 0.14 S/m and 0.24 S/m) align with the literature. The average conductivity is observed to change by -21% as the contact force increases from 2 N to 10 N. In contrast, in conditions where the fluid concentration in the measurement area is expected to be lower, very small changes are observed (less than 2.5%). These results suggest that the LAA conductivity is affected by the contact force due to the fluid concentration in the tissue. This work suggests that contact force should be controlled for in all future experiments.


Assuntos
Apêndice Atrial , Animais , Bovinos , Condutividade Elétrica , Fenômenos Mecânicos
11.
Sensors (Basel) ; 21(23)2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34884050

RESUMO

Microwave breast imaging has seen increasing use in clinical investigations in the past decade with over eight systems having being trialled with patients. The majority of systems use radar-based algorithms to reconstruct the image shown to the clinician which requires an estimate of the dielectric properties of the breast to synthetically focus signals to reconstruct the image. Both simulated and experimental studies have shown that, even in simplified scenarios, misestimation of the dielectric properties can impair both the image quality and tumour detection. Many methods have been proposed to address the issue of the estimation of dielectric properties, but few have been tested with patient images. In this work, a leading approach for dielectric properties estimation based on the computation of many candidate images for microwave breast imaging is analysed with patient images for the first time. Using five clinical case studies of both healthy breasts and breasts with abnormalities, the advantages and disadvantages of computational patient-specific microwave breast image reconstruction are highlighted.


Assuntos
Neoplasias da Mama , Micro-Ondas , Algoritmos , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Radar
12.
Sensors (Basel) ; 20(14)2020 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-32708680

RESUMO

The dielectric characterization of tissue targets of microwave thermal ablation (MTA) have improved the efficacy and pre-procedural planning of treatment. In some clinical scenarios, the tissue target lies at the interface with an external layer of fat. The aim of this work is to investigate the influence of the dielectric contrast between fat and target tissue on the shape and size of the ablation zone. A 2.45 GHz monopole antenna is placed parallel to an interface modelled by fat and a tissue characterized by higher dielectric properties and powered at 30 and 60 W for 60 s. The performances of MTA are numerically investigated considering different interface scenarios (i.e., different widths of fat layer, shifts in the antenna alignment) and a homogeneous reference scenario. Experiments (N = 10) are conducted on ex vivo porcine tissue to validate the numerical results. Asymmetric heating patterns are obtained in the interface scenario, the ablation zone in the target tissue is two-fold to ten-fold the size of the zone in the adipose tissue, and up to four times larger than the homogenous scenario. The adipose tissue reflects the electromagnetic energy into the adjacent tissue target, reducing the heating in the opposite direction.


Assuntos
Técnicas de Ablação , Tecido Adiposo/cirurgia , Micro-Ondas , Animais , Temperatura Alta , Suínos
13.
Sensors (Basel) ; 20(21)2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33167562

RESUMO

Microwave tomography (MWT) can be used as an alternative modality for monitoring human bone health. Studies have found a significant dielectric contrast between healthy and diseased human trabecular bones. A set of diverse bone phantoms were developed based on single-pole Debye parameters of osteoporotic and osteoarthritis human trabecular bones. The bone phantoms were designed as a two-layered circular structure, where the outer layer mimics the dielectric properties of the cortical bone and the inner layer mimics the dielectric properties of the trabecular bone. The electromagnetic (EM) inverse scattering problem was solved using a distorted Born iterative method (DBIM). A compressed sensing-based linear inversion approach referred to as iterative method with adaptive thresholding for compressed sensing (IMATCS) has been employed for solving the underdetermined set of linear equations at each DBIM iteration. To overcome the challenges posed by the ill-posedness of the EM inverse scattering problem, the L2-based regularization approach was adopted in the amalgamation of the IMATCS approach. The simulation results showed that osteoporotic and osteoarthritis bones can be differentiated based on the reconstructed dielectric properties even for low values of the signal-to-noise ratio. These results show that the adopted approach can be used to monitor bone health based on the reconstructed dielectric properties.


Assuntos
Densidade Óssea , Osso e Ossos/diagnóstico por imagem , Imageamento de Micro-Ondas , Imagens de Fantasmas , Algoritmos , Humanos
14.
Sensors (Basel) ; 20(11)2020 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-32526983

RESUMO

The dielectric properties of biological tissues are typically measured using the open-ended coaxial probe technique, which is based on the assumption that the tissue sample is homogeneous. Therefore, for heterogeneous tissue samples, additional post-measurement sample processing is conducted. Specifically, post-measurement histological analysis may be performed in order to associate the measured dielectric properties with the tissue types present in a heterogeneous sample. Accurate post-measurement histological analysis enables identification of the constituent tissue types that contributed to the measured dielectric properties, and their relative distributions. There is no standard protocol for conducting post-measurement histological analysis, which leads to high numbers of excluded tissue samples and inconsistencies in the resulting reported data for heterogeneous tissues. To this extent, this study examines the post-measurement histological process and the challenges in associating the acquired dielectric properties with the different tissue types present in heterogeneous samples. The results demonstrate that the histological process inevitably alters the morphology of samples, thus introducing errors in the interpretation of the dielectric properties acquired from heterogeneous biological samples. Notably, sample size was seen to shrink by up to 90% through the histological process, meaning that sensing volume determined from fresh tissues is not directly applicable to histology images.


Assuntos
Técnicas Eletroquímicas , Técnicas Histológicas , Condutividade Elétrica , Humanos
15.
Sensors (Basel) ; 20(10)2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32466323

RESUMO

Electromagnetic-based hyperthermic therapies induce a controlled increase of temperature in a specific tissue target in order to increase the tissue perfusion or metabolism, or even to induce cell necrosis. These therapies require accurate knowledge of dielectric and thermal properties to optimise treatment plans. While dielectric properties have been well investigated, only a few studies have been conducted with the aim of understanding the changes of thermal properties as a function of temperature; i.e., thermal conductivity, volumetric heat capacity and thermal diffusivity. In this study, we experimentally investigate the thermal properties of ex vivo ovine liver in the hyperthermic temperature range, from 25 °C to 97 °C. A significant increase in thermal properties is observed only above 90 °C. An analytical model is developed to model the thermal properties as a function of temperature. Thermal properties are also investigated during the natural cooling of the heated tissue. A reversible phenomenon of the thermal properties is observed; during the cooling, thermal properties followed the same behaviour observed in the heating process. Additionally, tissue density and water content are evaluated at different temperatures. Density does not change with temperature; mass and volume losses change proportionally due to water vaporisation. A 30% water loss was observed above 90 °C.


Assuntos
Fenômenos Eletromagnéticos , Hipertermia Induzida , Fígado , Temperatura , Animais , Temperatura Alta , Fígado/fisiologia , Ovinos
16.
Sensors (Basel) ; 20(17)2020 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-32887340

RESUMO

We produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz-8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.


Assuntos
Neoplasias da Mama , Imageamento de Micro-Ondas , Imagens de Fantasmas , Axila , Neoplasias da Mama/diagnóstico por imagem , Humanos , Linfonodos , Tomografia Computadorizada por Raios X
17.
Int J Hyperthermia ; 36(1): 905-914, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31466482

RESUMO

Objective: To investigate the feasibility and efficacy of localized, subtotal, cortical-sparing microwave thermal ablation (MTA) as a potential curative management for primary aldosteronism. The study investigated with equal importance the selected ablation of small volumes of adrenal cortex while sparing adjacent cortex. Method: An in-vivo study was carried out in swine (n = 8) where MTA was applied under direct visualization, to the adrenal glands at 45 W or 70 W for 60 s, using a lateral, side-firing probe and a non-penetrative approach. Animals were survived for 48 h post-procedurally. Animals were investigated for markers of histological, immunohistochemical and biochemical evidence of adrenal function and adrenal damage by assessing samples drawn intra-operatively and at the time of euthanasia. Results: Selected MTA (70 W for 60 s) successfully ablated small adrenocortical volumes (∼0.8 cm3) characterized by coagulative necrosis and abnormal expression of functional markers (CYP11B1 and CYP17). Non-ablated, adjacent cortex was not affected and preserved normal expression of functional markers, without increased expression of markers of heat damage (HSP-70 and HMGB-1). Limited adrenal medullary damage was demonstrated histologically, clinically and biochemically. Conclusion: MTA offers potential as an efficient methodology for delivering targeted subtotal cortical-sparing adrenal ablation. Image-guided targeted MTA may also represent a safe future modality for curative management of PA, in the setting of both unilateral and bilateral disease.


Assuntos
Técnicas de Ablação , Hiperaldosteronismo/terapia , Hipertermia Induzida , Micro-Ondas/uso terapêutico , Córtex Suprarrenal/cirurgia , Hormônio Adrenocorticotrópico/sangue , Aldosterona/sangue , Animais , Hidrocortisona/sangue , Hiperaldosteronismo/sangue , Masculino , Metanefrina/sangue , Normetanefrina/sangue , Suínos
18.
J Stroke Cerebrovasc Dis ; 28(6): 1703-1709, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30878368

RESUMO

BACKGROUND: The association of lipid lowering therapy and intracerebral hemorrhage risk is controversial. METHODS: We performed a cumulative meta-analysis of lipid lowering trials that reported intracerebral hemorrhage. Statin, fibrate, ezetimibe, PCSK9, and CETP trials were included. We explored whether the association of lipid lowering therapy and risk of intracerebral hemorrhage may vary by baseline low-density lipoprotein (LDL) level, mean change in LDL or baseline cardiovascular risk of population. RESULTS: Among 39 trials (287,651 participants), lipid lowering therapy was not associated with a statistically significant increased risk of intracerebral hemorrhage (ICH) in primary and secondary prevention trials combined (odds ratio [OR], 1.12; 95% confidence interval [CI], .98-1.28). Lipid lowering was associated with an increased risk of ICH in secondary prevention trials (OR, 1.18; 95% CI, 1.00-1.38), but not in primary prevention trials (OR, 1.01; 95% CI, .78-1.30), but the test for interaction was not significant (P for interaction = .31). Meta-regression of baseline LDL or difference in LDL reduction between active and control did not explain significant heterogeneity between studies for ICH risk. Of 1000 individuals treated for 1 year for secondary prevention, we estimated 9.17 (95% CI, 5.78-12.66) fewer ischemic strokes and .48 (95% CI, .06-1.02) more ICH, and a net reduction of 8.69 in all stroke per 1000 person-years. CONCLUSIONS: The benefits of lipid lowering therapy in prevention of ischemic stroke greatly exceed the risk of ICH. Concern about ICH should not discourage stroke clinicians from prescribing lipid lowering therapy for secondary prevention of ischemic stroke.


Assuntos
Isquemia Encefálica/prevenção & controle , Hemorragia Cerebral/induzido quimicamente , Dislipidemias/tratamento farmacológico , Hipolipemiantes/efeitos adversos , Lipoproteínas LDL/sangue , Acidente Vascular Cerebral/prevenção & controle , Biomarcadores/sangue , Isquemia Encefálica/sangue , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/epidemiologia , Hemorragia Cerebral/diagnóstico , Hemorragia Cerebral/epidemiologia , Dislipidemias/sangue , Dislipidemias/diagnóstico , Dislipidemias/epidemiologia , Humanos , Prevenção Primária/métodos , Fatores de Proteção , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Prevenção Secundária/métodos , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Resultado do Tratamento
19.
Sensors (Basel) ; 18(6)2018 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-29882893

RESUMO

Confocal Microwave Imaging (CMI) for the early detection of breast cancer has been under development for over two decades and is currently going through early-phase clinical evaluation. The image reconstruction algorithm is a key signal processing component of any CMI-based breast imaging system and impacts the efficacy of CMI in detecting breast cancer. Several image reconstruction algorithms for CMI have been developed since its inception. These image reconstruction algorithms have been previously evaluated and compared, using both numerical and physical breast models, and healthy volunteer data. However, no study has been performed to evaluate the performance of image reconstruction algorithms using clinical patient data. In this study, a variety of imaging algorithms, including both data-independent and data-adaptive algorithms, were evaluated using data obtained from a small-scale patient study conducted at the University of Calgary. Six imaging algorithms were applied to reconstruct 3D images of five clinical patients. Reconstructed images for each algorithm and each patient were compared to the available clinical reports, in terms of abnormality detection and localisation. The imaging quality of each algorithm was evaluated using appropriate quality metrics. The results of the conventional Delay-and-Sum algorithm and the Delay-Multiply-and-Sum (DMAS) algorithm were found to be consistent with the clinical information, with DMAS producing better quality images compared to all other algorithms.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Micro-Ondas , Pacientes , Processamento de Sinais Assistido por Computador , Humanos
20.
Sensors (Basel) ; 17(12)2017 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-29211018

RESUMO

Inaccurate estimation of average dielectric properties can have a tangible impact on microwave radar-based breast images. Despite this, recent patient imaging studies have used a fixed estimate although this is known to vary from patient to patient. Parameter search algorithms are a promising technique for estimating the average dielectric properties from the reconstructed microwave images themselves without additional hardware. In this work, qualities of accurately reconstructed images are identified from point spread functions. As the qualities of accurately reconstructed microwave images are similar to the qualities of focused microscopic and photographic images, this work proposes the use of focal quality metrics for average dielectric property estimation. The robustness of the parameter search is evaluated using experimental dielectrically heterogeneous phantoms on the three-dimensional volumetric image. Based on a very broad initial estimate of the average dielectric properties, this paper shows how these metrics can be used as suitable fitness functions in parameter search algorithms to reconstruct clear and focused microwave radar images.


Assuntos
Micro-Ondas , Algoritmos , Mama , Neoplasias da Mama , Humanos , Imagens de Fantasmas , Radar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA