Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(17)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37687855

RESUMO

Herein, we developed a bio-functionalized solution-immersed silicon (SIS) sensor at the single-cell level to identify Erwinia amylovora (E. amylovora), a highly infectious bacterial pathogen responsible for fire blight, which is notorious for its rapid spread and destructive impact on apple and pear orchards. This method allows for ultra-sensitive measurements without pre-amplification or labeling compared to conventional methods. To detect a single cell of E. amylovora, we used Lipopolysaccharide Transporter E (LptE), which is involved in the assembly of lipopolysaccharide (LPS) at the surface of the outer membrane of E. amylovora, as a capture agent. We confirmed that LptE interacts with E. amylovora via LPS through in-house ELISA analysis, then used it to construct the sensor chip by immobilizing the capture molecule on the sensor surface modified with 3'-Aminopropyl triethoxysilane (APTES) and glutaraldehyde (GA). The LptE-based SIS sensor exhibited the sensitive and specific detection of the target bacterial cell in real time. The dose-response curve shows a linearity (R2 > 0.992) with wide dynamic ranges from 1 to 107 cells/mL for the target bacterial pathogen. The sensor showed the value change (dΨ) of approximately 0.008° for growing overlayer thickness induced from a single-cell E. amylovora, while no change in the control bacterial cell (Bacillus subtilis) was observed, or negligible change, if any. Furthermore, the bacterial sensor demonstrated a potential for the continuous detection of E. amylovora through simple surface regeneration, enabling its reusability. Taken together, our system has the potential to be applied in fields where early symptoms are not observed and where single-cell or ultra-sensitive detection is required, such as plant bacterial pathogen detection, foodborne pathogen monitoring and analysis, and pathogenic microbial diagnosis.


Assuntos
Erwinia amylovora , Lipopolissacarídeos , Bacillus subtilis , Ensaio de Imunoadsorção Enzimática
2.
Sensors (Basel) ; 21(9)2021 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-33922694

RESUMO

Early detection is critical to successfully eradicating a variety of cancers, so the development of a new cancer primary screening system is essential. Herein, we report an animal nose sensor system for the potential primary screening of lung cancer. To establish this, we developed an odor discrimination training device based on operant conditioning paradigms for detection of toluene, an odor indicator component of lung cancer. The rats (N = 15) were trained to jump onto a floating ledge in response to toluene-spiked breath samples. Twelve rats among 15 trained rats reached performance criterion in 12 consecutive successful tests within a given set, or over 12 sets, with a success rate of over 90%. Through a total of 1934 tests, the trained rats (N = 3) showed excellent performance for toluene detection with 82% accuracy, 83% sensitivity, 81% specificity, 80% positive predictive value (PPV) and 83% negative predictive value (NPV). The animals also acquired considerable performance for odor discrimination even in rigorous tests, validating odor specificity. Since environmental and long-term stability are important factors that can influence the sensing results, the performance of the trained rats was studied under specified temperature (20, 25, and 30 °C) and humidity (30%, 45%, and 60% RH) conditions, and monitored over a period of 45 days. At given conditions of temperature and humidity, the animal sensors showed an average accuracy within a deviation range of ±10%, indicating the excellent environmental stability of the detection rats. Surprisingly, the trained rats did not differ in retention of last odor discrimination when tested 45 days after training, denoting that the rats' memory for trained odor is still available over a long period of time. When taken together, these results indicate that our odor discrimination training system can be useful for non-invasive breath testing and potential primary screening of lung cancer.


Assuntos
Neoplasias Pulmonares , Tolueno , Animais , Detecção Precoce de Câncer , Neoplasias Pulmonares/diagnóstico , Odorantes , Ratos , Olfato
3.
Sensors (Basel) ; 21(11)2021 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-34073351

RESUMO

The discrimination learning of multiple odors, in which multi-odor can be associated with different responses, is important for responding quickly and accurately to changes in the external environment. However, very few studies have been done on multi-odor discrimination by animal sniffing. Herein, we report a novel multi-odor discrimination system by detection rats based on the combination of 2-Choice and Go/No-Go (GNG) tasks into a single paradigm, in which the Go response of GNG was replaced by 2-Choice, for detection of toluene and acetone, which are odor indicators of lung cancer and diabetes, respectively. Three of six trained rats reached performance criterion, in 12 consecutive successful tests within a given set or over 12 sets with a success rate of over 90%. Through a total of 1300 tests, the trained animals (N = 3) showed multi-odor sensing performance with 88% accuracy, 87% sensitivity and 90% specificity. In addition, a dependence of behavior response time on odor concentrations under given concentration conditions was observed, suggesting that the system could be used for quantitative measurements. Furthermore, the animals' multi-odor sensing performance has lasted for 45 days, indicating long-term stability of the learned multi-odor discrimination. These findings demonstrate that multi-odor discrimination can be achieved by rat sniffing, potentially providing insight into the rapid, accurate and cost-effective multi-odor monitoring in the lung cancer and diabetes.


Assuntos
Diabetes Mellitus , Neoplasias Pulmonares , Animais , Discriminação Psicológica , Neoplasias Pulmonares/diagnóstico , Odorantes , Ratos , Olfato
4.
Sensors (Basel) ; 18(1)2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29301263

RESUMO

A bioelectronic nose, an intelligent chemical sensor array system coupled with bio-receptors to identify gases and vapours, resembles mammalian olfaction by which many vertebrates can sniff out volatile organic compounds (VOCs) sensitively and specifically even at very low concentrations. Olfaction is undertaken by the olfactory system, which detects odorants that are inhaled through the nose where they come into contact with the olfactory epithelium containing olfactory receptors (ORs). Because of its ability to mimic biological olfaction, a bio-inspired electronic nose has been used to detect a variety of important compounds in complex environments. Recently, biosensor systems have been introduced that combine nanoelectronic technology and olfactory receptors themselves as a source of capturing elements for biosensing. In this article, we will present the latest advances in bioelectronic nose technology mimicking the olfactory system, including biological recognition elements, emerging detection systems, production and immobilization of sensing elements on sensor surface, and applications of bioelectronic noses. Furthermore, current research trends and future challenges in this field will be discussed.


Assuntos
Nariz , Animais , Técnicas Biossensoriais , Nariz Eletrônico , Odorantes , Receptores Odorantes , Olfato
5.
Biosensors (Basel) ; 13(8)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622868

RESUMO

In this study, we developed a highly sensitive and specific bimolecular fluorescence complementation (BiFC)-based influenza A virus (IAV)-sensing system by combining a galactose/glucose-binding protein (GGBP) with an N-terminal large domain (YN1-172) and a C-terminal small domain (YC173-239) made up of enhanced yellow fluorescence protein (eYFP). The GGBP-based BiFC reporter exhibits the fluorescence reconstitution as a result of conformational changes in GGBP when lactose, which was derived from 6'-silalyllactose and used as a substrate for neuraminidase (NA), binds to GGBP in the presence of IAV. The system showed a linear dynamic range extending from 1 × 100 to 1 × 107 TCID50/mL, and it had a detection limit of 1.1 × 100 TCID50/mL for IAV (H1N1), demonstrating ultra-high sensitivity. Our system exhibited fluorescence intensity enhancements in the presence of IAV, while it displayed weak fluorescence signals when exposed to NA-deficient viruses, such as RSV A, RSV B, adenovirus and rhinovirus, thereby indicating selective responses for IAV detection. Overall, our system provides a simple, highly sensitive and specific IAV detection platform based on BiFC that is capable of detecting ligand-induced protein conformational changes, obviating the need for virus culture or RNA extraction processes.


Assuntos
Vírus da Influenza A Subtipo H1N1 , Vírus da Influenza A , Fluorescência , Glucose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA