1.
J Appl Clin Med Phys ; 23(8): e13645, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35789532

RESUMO

We aim to evaluate the basic characteristics of SRS MapCHECK (SRSMC) for CyberKnife (CK) and establish a dose verification system using SRSMC for the tumor-tracking irradiation for CK. The field size and angular dependence of SRSMC were evaluated for basic characterization. The output factors (OPFs) and absolute doses measured by SRSMC were compared with those measured using microDiamond and microchamber detectors and those calculated by the treatment planning system (TPS). The angular dependence was evaluated by comparing the SRSMC with a microchamber. The tumor-tracking dose verification system consists of SRSMC and a moving platform. The doses measured using SRSMC were compared with the doses measured using a microchamber and radiochromic film. The OPFs and absolute doses of SRSMC were within ±3.0% error for almost all field sizes, and the angular dependence was within ±2.0% for all incidence angles. The absolute dose errors between SRSMC and TPS tended to increase when the field size was smaller than 10 mm. The absolute doses of the tumor-tracking irradiation measured using SRSMC and those measured using a microchamber agreed within 1.0%, and the gamma pass rates of SRSMC in comparison with those of the radiochromic film were greater than 95%. The basic characteristics of SRSMC for CK presented acceptable results for clinical use. The results of the tumor-tracking dose verification system realized using SRSMC were equivalent to those of conventional methods, and this system is expected to contribute toward improving the efficiency of quality control in many facilities.


Assuntos
Neoplasias , Radiocirurgia , Humanos , Neoplasias/radioterapia , Neoplasias/cirurgia , Radiometria/métodos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Artigo em Japonês | MEDLINE | ID: mdl-32963134

RESUMO

AIM: The aim of this work was to evaluate the coincidence between light and X-ray field width in air. BACKGROUND: Light fields are often used for confirmation of irradiation position to superficial tumors and final confirmation of the patient's irradiation position. To guarantee collation by the light field, the light and X-ray fields must coincide. Currently, the light field width is determined mainly by visual evaluation using manual methods, such as use of graph paper and rulers. The light field width is difficult to visually recognize a definite position at the edge of the light field. MATERIALS AND METHODS: We quantified the width of light fields emitted from a linear accelerator using a light probe detector and compared the results with those of X-ray fields. In-air measurements were conducted at the same position in the light field with the light probe detector and X-ray field using an ionization chamber installed in an emptied three-dimensional water phantom. RESULTS: The radiation field in air was approximately 2 mm larger than the light field, and we found some influence of transmission and scattered rays on the penumbra region. Before and after exchanging crosshair sheets, the fields also exhibited differences in uniformity. CONCLUSIONS: The proposed method quantifies the light field using a photodetector and can be used to compare the light field with the X-ray field, conforming a useful tool for evaluating the accuracy of treatment devices in an objective and systematic manner.


Assuntos
Aceleradores de Partículas , Radiometria , Humanos , Imagens de Fantasmas , Radiografia , Raios X
3.
Artigo em Japonês | MEDLINE | ID: mdl-32201416

RESUMO

INTRODUCTION: External electron beams have excellent distributions in treatment for superficial tumors while suppressing influence deeper normal tissue. However, the skin surface cannot be given a sufficient dose due to the build-up effect. In this study, we have investigated the combination of electron beams to expand the treatment region by keeping the dose gradient beyond dmax. MATERIALS AND METHODS: The percentage depth doses of different electron beams were superimposed on a spreadsheet to determine the combinations of electron beams so that the treatment range was maximized. Based on the obtained weight for electron beams, dose distributions were calculated using a treatment planning system and examined for potential clinical application. RESULTS: With the combination of 4 MeV and 9 MeV electron beams, the 90% treatment range in the depth direction increased by 8.0 mm, and with 4 MeV and 12 MeV beams, it increased by 4.0 mm, with the same maximum dose depth and halfdose depth of the absorbed dose. The dose calculations were performed using the treatment planning system yielded similar results with a matching degree of ±1.5%. CONCLUSIONS: Although the influences of low monitor unit values and daily output differences remain to be considered, the results suggest that the proposed approach can be clinically applied to expand treatment regions easily.


Assuntos
Elétrons , Radiometria , Estudos de Viabilidade , Método de Monte Carlo , Dosagem Radioterapêutica
4.
Nagoya J Med Sci ; 78(3): 313-21, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27578915

RESUMO

The application of neoadjuvant androgen deprivation (NAD) in prostate cancer leads to a reduction in prostate volume, and the trends in volume reduction differ according to the treatment duration of NAD. A reduction in volume during external beam radiation therapy may lead to the exposure of normal tissues to an unexpected dose. In fact, prostate volume reductions have primarily been reported in European and American institutions. Although the prostate volume of Japanese patients is known to be small, the trends in prostate volume change during radiation therapy remain unclear. In the present study, we aimed to evaluate the changes in prostate volume of Japanese patients during intensity-modulated radiation therapy (IMRT) with NAD. Nineteen Japanese patients with prostate cancer underwent IMRT with NAD. Kilovoltage computed tomography (CT) images were obtained for treatment planning and verification of the treatment position for each treatment fraction. The patients were divided into 3 groups based on the duration of NAD, as follows: NAD < 3 months (short NAD: S-NAD), 3 months ≤ NAD < 6 months (middle NAD: M-NAD), and NAD ≥ 6 months (long NAD: L-NAD). The prostate volume reductions at the 36th treatment fraction, relative to the planning CT, were 7.8%, 2.0%, and 1.7% for the S-NAD, M-NAD, and L-NAD groups, respectively. Prostate volume shrunk greater in the S-NAD group than in the M-NAD and L-NAD groups; this finding was consistent with those of previous studies. The prostate volume changes in Japanese patients were smaller compared to those in European and American patients.


Assuntos
Terapia Neoadjuvante , Antagonistas de Androgênios , Humanos , Masculino , Antígeno Prostático Específico , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Estudos Retrospectivos
5.
J Appl Clin Med Phys ; 17(1): 234-245, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894359

RESUMO

Metal dental restoration materials cause dose enhancement upstream and dose disturbance downstream of the high-density inhomogeneous regions in which these materials are used. In this study, we evaluated the impact of a dental metallic crown (DMC) on intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for head and neck cancer. Additionally, the possibility of sparing the oral mucosa from dose enhancement using an individual intraoral mouthpiece was evaluated. An experimental oral phantom was designed to verify the dosimetric impact of a DMC. We evaluated the effect on single beam, parallel opposing beam, arc beam, IMRT, and VMAT treatment plans. To evaluate the utility of a 3-mm-thick intraoral mouthpiece, the doses across the mouthpiece were measured. For single beam irradiation, the measured doses at the entrance and exit planes of the DMC were 51% higher and 21% lower than the calculated dose by the treatment planning system, respectively. The maximum dose enhancements were 22% and 46% for parallel opposing beams and the 90° arc rotation beam, respectively. For IMRT and VMAT, the measured doses adjacent to the DMC were 12.2% ± 6.3% (mean ± 1.96SD) and 12.7% ± 2.5% higher than the calculated doses, respectively. With regard to the performance of the intraoral mouthpiece for the IMRT and VMAT cases, the disagreement between measured and calculated doses at the outermost surface of the mouthpieces were -2.0%, and 2.0%, respectively. Dose enhancements caused by DMC-mediated radiation scattering occurred during IMRT and VMAT. Because it is difficult to accurately estimate the dose perturbations, careful consideration is necessary when planning head and neck cancer treatments in patients with DMCs. To spare the oral mucosa from dose enhancement, the use of an individual intraoral mouthpiece should be considered.


Assuntos
Coroas/efeitos adversos , Neoplasias de Cabeça e Pescoço/radioterapia , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(4): 313-320, 2023 Apr 20.
Artigo em Japonês | MEDLINE | ID: mdl-36792203

RESUMO

INTRODUCTION: X-ray penumbral width depends on the size of the detector in the off-axis ratio of medical linear accelerators. The use of detectors with appropriate sizes according to the irradiation field is recommended. However, when measuring dose distributions, the shape of the off-axis ratio differs depending on detectors even if the dose distribution remains unchanged. This study aims to calculate the penumbral width using multiple detectors and obtain the independent penumbral width according to irradiation size. MATERIALS AND METHODS: Using the X-ray output from a medical linear accelerator, off-axis ratios in water were measured using nine types of detectors. Penumbral width was calculated from each measured off-axis ratio by linear approximation and determining the intercept for analysis. The experimental irradiation fields were square areas (1×1 cm2 to 10×10 cm2). Penumbral widths were obtained from three types of detectors with different sensitive region widths of at least 1.2 mm. RESULTS: The values estimated from the nine detectors were 2.51-4.07 and 2.93-4.70 mm for 6 and 10 MV X-rays, respectively. The penumbral width and variation due to detector size increased with the irradiation field. The results estimated from the three selected detectors varied within ±0.5 mm compared with those from the nine detectors and were generally consistent. The reliability of the results was evaluated by comparing with the results from past studies and Monte Carlo simulations. CONCLUSION: Calculation of the penumbral width can be done regardless of size for various detectors. Thus, dose distributions can be compared for the linear accelerator at different facilities.


Assuntos
Aceleradores de Partículas , Radiometria , Raios X , Reprodutibilidade dos Testes , Radiografia , Método de Monte Carlo , Fótons
7.
Radiol Phys Technol ; 16(4): 578-583, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37801216

RESUMO

This study presents two cases of tumors in contact with the inferior vena cava during radiotherapy, and introduces a clinically useful technique for identifying tumor boundaries adjacent to blood vessels by adjusting the position of the field-of-view (FOV) to enhance the inflow effect in magnetic resonance imaging. We named this technique "Shifting-FOV." This method consists of three steps: (1) remove the upper and lower saturation pulses outside the FOV, (2) align the FOV to position the lower edge of the imaging slab as close to the tumor as possible, and (3) manually adjust the table position to locate the tumor at the center of the magnetic field. The proposed method allowed for accurate identification of the tumor/vessel boundaries in both cases. This is a useful technique that can be readily applied to other facilities. Furthermore, images obtained using this technique may enable accurate tumor contouring in radiotherapy treatment planning.


Assuntos
Neoplasias , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Campos Magnéticos
8.
Biomed Phys Eng Express ; 10(1)2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37948761

RESUMO

Objective. Precise monitoring of the position and dwell time of iridium-192 (Ir-192) during high-dose-rate (HDR) brachytherapy is crucial to avoid serious damage to normal tissues. Source imaging using a compact gamma camera is a potential approach for monitoring. However, images from the gamma camera are affected by blurring and statistical noise, which impact the accuracy of source position monitoring. This study aimed to develop a deep-learning approach for estimating ideal source images that reduce the effect of blurring and statistical noise from experimental images captured using a compact gamma camera.Approach. A double pix2pix model was trained using the simulated gamma camera images of an Ir-192 source. The first model was responsible for denoising the Ir-192 images, whereas the second model performed super resolution. Trained models were then applied to the experimental images to estimate the ideal images.Main results. At a distance of 100 mm between the compact gamma camera and the Ir-192 source, the difference in full width at half maximum (FWHM) between the estimated and actual source sizes was approximately 0.5 mm for a measurement time of 1.5 s. This difference has been improved from approximately 2.7 mm without the use of DL. Even with a measurement time of 0.1 s, the ideal images could be estimated as accurately as in the 1.5 s measurements. This method consistently achieved accurate estimations of the source images at any position within the field of view; however, the difference increased with the distance between the Ir-192 source and the compact gamma camera.Significance. The proposed method successfully provided estimated images from the experimental images within errors smaller than 0.5 mm at 100 mm. This method is promising for reducing blurring and statistical noise from the experimental images, enabling precise real-time monitoring of Ir-192 sources during HDR brachytherapy.


Assuntos
Braquiterapia , Aprendizado Profundo , Radioisótopos de Irídio , Braquiterapia/métodos , Câmaras gama
9.
Nagoya J Med Sci ; 85(3): 504-517, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37829483

RESUMO

Prostatic urethra identification is crucial in prostate stereotactic body radiotherapy (SBRT) to reduce the risk of urinary toxicity. Although computed tomography (CT) with a catheter is commonly employed, it is invasive, and catheter placement may displace the urethral position, resulting in possible planning inaccuracies. However, magnetic resonance imaging (MRI) can overcome these weaknesses. Accurate urethral identification and minimal daily variation could ensure a highly accurate SBRT. In this study, we investigated the usefulness of a three-dimensional (3D) T2-weighted (T2W) sequence for urethral identification, and the interfractional motion of the prostatic urethra on CT with a catheter and MRI without a catheter for implementing noninvasive SBRT. Thirty-two patients were divided into three groups. The first group underwent MRI without a catheter to evaluate urethral identification by two-dimensional (2D)- and 3D-T2W sequences using mean slice-wise Hausdorff distance (MSHD) and Dice similarity coefficient (DSC) of the contouring by two operators and using visual assessment. The second group provided 3-day MRI data without a catheter using 3D-T2W, and the third provided 3-day CT data with a catheter to evaluate the interfractional motion using MSHD, DSC, and displacement distance (Dd). The MSHD and DSC for the interoperator variability in urethral identification and visual assessment were superior in 3D-T2W than in 2D-T2W. Regarding interfractional motion, the Dd value for prostatic urethra was smaller in MRI than in CT. These findings indicate that the 3D-T2W yielded adequate prostatic urethral identification, and catheter-free MRI resulted in less interfractional motion, suggesting that 3D-T2W MRI without a catheter is a feasible noninvasive approach to performing prostate SBRT.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Radiocirurgia/métodos , Uretra/diagnóstico por imagem , Uretra/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Imageamento por Ressonância Magnética/métodos
10.
F1000Res ; 12: 798, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38204487

RESUMO

Background: Currently, the standard curative treatment for ventricular tachycardia (VT) and ventricular fibrillation (VF) is radiofrequency catheter ablation. However, when the VT circuit is deep in the myocardium, the catheter may not be delivered, and a new, minimally invasive treatment using different energies is desired. Methods: This is a protocol paper for a feasibility study designed to provide stereotactic radiotherapy for refractory VT not cured by catheter ablation after at least one catheter ablation. The primary end point is to evaluate the short-term safety of this treatment and the secondary endpoint is to evaluate its efficacy as assessed by the reduction in VT episode. Cyberknife M6 radiosurgery system will be used for treatment, and the prescribed dose to the target will be 25Gy in one fraction. The study will be conducted on three patients. Conclusion: Since catheter ablation is the only treatment option for VT that is covered by insurance in Japan, there is currently no other treatment for VT/VF that cannot be cured by catheter ablation. We hope that this feasibility study will provide hope for patients who are currently under the stress of ICD activation. Trial registration: The study has been registered in the Japan Registry of Clinical Trials (jRCTs042230030).


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Catéteres , Japão , Miocárdio , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Ensaios Clínicos como Assunto
11.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(7): 699-710, 2022 Jul 20.
Artigo em Japonês | MEDLINE | ID: mdl-35718465

RESUMO

INTRODUCTION: In electron beam radiotherapy, an irradiation field is created with a cutout block using a low melting point lead alloy. The block can be replaced with a lead plate as a shield. Dose distribution is expected to be affected by differences in the material and thickness of the shield. Thus, this study aimed to investigate the cause of differences in dose distribution by reproducing the electron beam irradiation condition via Monte Carlo simulation, comparing dose distribution when each shield is used and analyzing energy fluence distribution. MATERIALS AND METHODS: Radiation interaction in the treatment device manufactured by Varian was assessed using the general-purpose simulation code, and the dose distribution in the water was calculated. Electron energy fluence and incident angle of the electron fluence incident on the water surface were analyzed, and the effect of the difference in the shield was investigated in the irradiation field limited to 3 cm or less. RESULTS: Regarding dose distribution, the deviation in the buildup area became larger when the lead plate was made thinner. A difference of 1.6-6.8% was observed on an average when comparing the buildup region of depth dose distributions except for 1×1 cm2 field. In electron energy fluence, the lower the lead thickness, the higher the low energy component, which affected the buildup region. The effect was greater as the electron beam energy increased. CONCLUSION: It was possible to evaluate the difference in scattered radiation between the low melting point lead alloy and the lead plate by MC simulation. Based on the study findings, the effect of scattered electrons generated from the block was strong as a factor.


Assuntos
Elétrons , Radiometria , Ligas , Simulação por Computador , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Água
12.
Radiol Phys Technol ; 15(4): 291-297, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35932415

RESUMO

Current dosimetry protocols specify an effective point of measurement (EPOM) shift of 0.6r for a cylindrical ionization chamber in photon beams. However, prior studies have reported that this shift was excessively large. The objective of this study was to experimentally evaluate the EPOM shifts in photon beams for cylindrical ionization chambers, which are widely used in clinical practice, and thus determine the appropriate EPOM shift. A microdiamond detector, which is a semiconductor detector with a small sensitive volume, was used as a reference detector, and the EPOM shifts of 11 types of cylindrical ionization chambers were evaluated at 6 MV and 10 MV. The depth shift from the percent depth dose (PDD) of the reference detector to that of the evaluated chamber was calculated using the least-squares method and was defined as the EPOM shift. The EPOM shift of the 10 MV condition was slightly larger than that of the 6 MV condition. However, because this trend was not observed for all chambers, the results of the two energies were averaged, and the EPOM shifts were determined to be 0.33r-0.43r (± 0.05) for 10 types of ionization chambers, and 0.03r (± 0.03) for the A1SL chamber. The shifts for all ionization chambers were smaller than 0.6r, indicating that the recommended EPOM shifts were overestimated and the absorbed dose was underestimated at the calibration depth. Hence, the appropriate EPOM shift of the 10 types of ionization chambers was 0.4r (the geometric center of the A1SL chamber), with a dose uncertainty of 0.05%.


Assuntos
Elétrons , Radiometria , Radiometria/métodos , Fótons , Incerteza
13.
Cureus ; 14(7): e27269, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36039267

RESUMO

Magnetic resonance imaging (MRI) is now essential in stereotactic radiotherapy (SRT) planning for brain tumors because of its excellence in soft-tissue contrast and high spatial resolution. However, MRI distortion is sometimes difficult to recognize, and it may cause large misalignments in radiotherapy planning. In this case report, we will show how much difference in the dose distribution of SRT can be made by using MRI without distortion correction.

14.
Nagoya J Med Sci ; 84(1): 29-41, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35391999

RESUMO

We propose two methods to evaluate system-related distortion in magnetic resonance imaging (MRI) in radiation therapy treatment planning (RTP) and demonstrate the importance of three-dimensional (3D) distortion correction (DC) by quantitatively measuring the distortion magnitude. First, a small pin phantom was scanned at multiple positions using an external laser guide for accurate phantom placement and combined into one image encompassing a large area. Direct plane images were used for evaluating in-plane distortion and multiplanar reconstruction images for through-plane distortion with no DC, two-dimensional (2D) DC, and 3D DC. Second, a large grid sheet was scanned as the direct plane of the phantom placement. The distortion magnitude was determined by measuring the displacement between the MRI and reference coordinates. The measured distortions were compared between in- and through-plane when applying DC and between the two methods. The small pin phantom method can be used to evaluate a wide range of distortions, whereas data from the entire plane can be obtained with a single scan using the grid sheet without a laser guide. The mean distortion magnitudes differed between the methods. Furthermore, the 3D DC reduced in- and through-plane distortions. In conclusion, the small pin phantom method can be used to evaluate a wide range of distortions by creating a combined image, whereas the grid sheet method is simpler, accurate, repeatable, and does not require a special-order phantom or laser guide. As 3D DC reduces both in- and through-plane distortions, it can be used to improve RTP quality.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
15.
Med Phys ; 49(8): 5409-5416, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35670250

RESUMO

OBJECTIVE: Dose distribution measurements of high-energy X-rays from medical linear accelerators (LINAC) in water are important for quality control (QC) of the system. Although Cherenkov-light imaging is a useful method for measuring the high-energy X-ray dose distribution, depth profiles have an underestimated dose at increased depths due to the angular dependency of the Cherenkov light generated in water. In this study, we use a linear polarizer to separate the majority of polarized components from the majority of unpolarized components of Cherenkov-light images in water and then use this information to correct for angular dependencies. METHODS: A water phantom, a cooled charge-coupled device (CCD) camera, and a polarizer were installed in a black box. Then, the water phantom was irradiated from the upper side with 6 or 10 MV X-rays, and the Cherenkov light generated in water was imaged with the polarizer axis at both parallel and perpendicular orientations to the beam. By using these images from the two orientations relative to the beam, we corrected the angular dependency of the Cherenkov light. RESULTS: By subtracting the images measured with the polarizer perpendicular to the beams from the images measured with the polarizer parallel to the beams, we could obtain images with only the polarized components. Using these images, we could calculate the images with non-polarized components that had similar depth profiles to those calculated with a planning system. The average difference between corrected depth profiles and those calculated with the planning system was less than 1%, while that between uncorrected depth profiles and the planning system was more than 8.3% in depths of water from 20 to 100 mm. CONCLUSION: We conclude that the use of the polarizer has the potential to improve the accuracy of dose distribution in Cherenkov-light imaging of water using high-energy X-rays.


Assuntos
Aceleradores de Partículas , Água , Imagens de Fantasmas , Radiometria , Planejamento da Radioterapia Assistida por Computador/métodos , Raios X
16.
Phys Med ; 95: 9-15, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35063796

RESUMO

PURPOSE: Gold fiducial markers are used to guide liver stereotactic body radiation therapy (SBRT) and are hard to detect by magnetic resonance imaging (MRI). In this study, the parameters of the three-dimensional T1-weighted turbo gradient-echo (3D T1W-GRE) sequence were optimized for gold marker detection without degrading tumor delineation. METHODS: Custom-made phantoms mimicking tumor and normal liver parenchyma were prepared and embedded with a gold marker. The 3D T1W-GRE was scanned by varying echo time (TE), bandwidth (BW), flip angle (FA), and base matrix size. The signal-to-noise ratio (SNR), contrast ratio (CR), and relative standard deviation (RSD) of the signal intensity in the area including the gold marker were evaluated, and the parameters were optimized accordingly. The modified 3D T1W-GRE (called HYBRID) was compared with the conventional T1W-GRE- and T2*-sequences in both phantom and clinical studies. In the clinical study of six patients with primary liver tumors, two observers visually assessed marker detection, tumor delineation, and overall image quality on a four-point scale. RESULTS: In the phantom study, HYBRID showed significantly higher SNR and RSD than those of conventional T1W-GRE (P < 0.001). In the clinical study, HYBRID yielded significantly higher scores than conventional T1W-GRE did in terms of marker detection (P < 0.001). The scores of both sequences were not statistically different in terms of tumor delineation and overall image quality (P = 0.56 and P = 0.32). CONCLUSIONS: The proposed HYBRID sequence improved gold fiducial marker detection without degrading tumor delineation in MRI for SBRT of primary liver tumor.


Assuntos
Neoplasias Hepáticas , Radiocirurgia , Meios de Contraste , Marcadores Fiduciais , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética/métodos
17.
Phys Med ; 103: 66-73, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36244135

RESUMO

PURPOSE: Although real-time imaging of the high-activity iridium-192 (Ir-192) source position during high-dose-rate (HDR) brachytherapy using a high-energy gamma camera system is a promising approach, the energy window was not optimized for spatial resolution or scatter fraction. METHODS: By using a list-mode data-acquisition system that can acquire energy information of a cerium-doped yttrium aluminum perovskite (YA1O3: YAP(Ce)) gamma camera, we tried to optimize the energy window's setting to improve the spatial resolution and reduce scatter fraction. RESULTS: The spatial resolution was highest for the central energy of the window at ∼300 keV. The scatter fraction was also smallest for the central energy of the window at ∼300 keV, and the scatter fraction was more than 48 % smaller than that for the full energy window. CONCLUSIONS: We clarified that the spatial resolution can be improved and the scatter fraction can be reduced through optimizing the energy window of the YAP(Ce) gamma camera by setting the central energy of the window to ∼300 keV for HDR brachytherapy.


Assuntos
Braquiterapia , Câmaras gama , Radioisótopos de Irídio/uso terapêutico , Imagens de Fantasmas
18.
Med Phys ; 49(12): 7703-7714, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36063027

RESUMO

PURPOSE: Measurement of the dwell time and moving speed of a high-activity iridium-192 (Ir-192) source used for high-dose-rate (HDR) brachytherapy is important for estimating the precise dose delivery to a tumor. For this purpose, we used a cerium-doped yttrium aluminum perovskite (YA1O3 :YAP(Ce)) gamma camera system, combined with a list-mode data acquisition system that can acquire short-time sequential images, and measured the dwell times and moving speeds of the Ir-192 source. METHODS: Gamma photon imaging was conducted using the gamma camera in list mode for the Ir-192 source of HDR brachytherapy with fixed dwell times and positions. The acquired list-mode images were sorted to millisecond-order interval time sequential images to evaluate the dwell time at each position. Time count rate curves were derived to calculate the dwell time at each source position and moving speed of the source. RESULTS: We could measure the millisecond-order time sequential images for the Ir-192 source. The measured times for the preset dwell times of 2 s and 10 s were 1.98 to 2.00 s full width at half maximum (FWHM) and 10.0 s FWHM, respectively. The dwell times at the first dwell position were larger than those at other positions. We also measured the moving speeds of the source after the dwells while moving back to the afterloader and found the speed increased with the distance from the edge of the field of view to the last dwell position. CONCLUSION: We conclude that millisecond-order time sequential imaging of the Ir-192 source is possible by using a gamma camera and is useful for evaluating the dwell times and moving speeds of the Ir-192 source.


Assuntos
Braquiterapia , Dosagem Radioterapêutica , Braquiterapia/métodos , Radioisótopos de Irídio/uso terapêutico , Diagnóstico por Imagem
19.
Igaku Butsuri ; 41(1): 1-9, 2021.
Artigo em Japonês | MEDLINE | ID: mdl-33853977

RESUMO

PURPOSE: The in-room laser which is used for patient positioning in radiotherapy is generally projected on the radiation isocenter determined by the Winston-Lutz test and so on. In this study, a couch-mounted verification device was developed that could evaluate all in-room lasers' alignment including the horizontality and verticality at one time. The device has the function to perform the light/radiation field coincidence test and the Winston-Lutz test at the same time. The aim of this report was to introduce the verification procedure for two tests, using the newly developed software and device, and to present the tuning flow of the in-room laser. Moreover, the analysis accuracy of the developed software was evaluated in comparison with commercial software. METHODS: First, the light/radiation field was evaluated by using tungsten markers on the central surface of the device. Next, after aligning the long-carved lines on the front and sides of the device with the in-room lasers, the Winston-Lutz test was carried out by using the tungsten sphere in the center of the device. The acquired images were collectively analyzed using the developed software equipped with the reporting function. Additionally, the result of this Winston-Lutz test was compared with the result from commercial software. RESULTS: A series of the light/radiation field coincidence test and the Winston-Lutz test were analyzed using the developed device and software. The results could be easily confirmed using the reporting function of the software. Regarding the result of the Winston-Lutz test, most of the analysis differences between the developed software and commercially available software were within the pixel size (0.22 mm). DISCUSSIONS: Since the accuracy of the radiation field affects the result of the Winston-Lutz test, the presented procedure of performing the light/radiation coincidence field test in advance facilitates the interpretation of the error of the Winston-Lutz test. Based on the results of the Winston-Lutz test, we were able to demonstrate the tuning flow of all in-room lasers including the horizontality and verticality by using the developed device. CONCLUSIONS: We have developed a couch-mounted verification device and software that can evaluate the light/radiation coincidence field test and the alignment including the horizontality and verticality of the in-room laser used for patient positioning in radiotherapy, and reported its usefulness. The analysis accuracy of the developed software was comparable to that of commercially available software. The use of this device and the developed software would contribute to not only the efficiency of adjusting all in-room lasers' alignment including the horizontality and verticality but also reflect accurately the result of the Winston-Lutz test.


Assuntos
Lasers , Software , Humanos , Aceleradores de Partículas , Imagens de Fantasmas
20.
Med Phys ; 48(1): 488-499, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33216999

RESUMO

PURPOSE: We developed a novel and simple method to measure the source positions in applicators directly for high-dose-rate (HDR) brachytherapy based on Cherenkov emission imaging, and evaluated the performance. METHODS: The light emission from plastic applicators used in cervical cancer treatments, irradiated by an 192 Ir γ-ray source, was captured using a charge-coupled device camera. Moreover, we attached plastics of different shapes, including tapes, tubes, and plates to a metal applicator, to use as screens for the Cherenkov imaging. We determined the source positions and dwell intervals from the light profiles along with the applicator and compared these with preset values and dummy marker measurements. RESULTS: The source positions and dwell intervals measured from the light images were comparable to the dummy marker measurements and preset values. The distance from the applicator tip to the first source positions agreed with the dummy marker measurements within 0.2 mm for the plastic tandem. The dwell intervals measured using the Cherenkov method agreed with the preset values within 0.6 mm. The distances measured with three plastic types on the metal applicator also agreed with the dummy marker measurements within 0.2 mm. The dwell intervals measured using the plastic tape agreed with the preset values within 0.7 mm. CONCLUSIONS: The proposed method should be suitable for rapid and easy quality assurance (QA) investigations in HDR brachytherapy, as it enables source position using a single image. The method allows for real-time, filmless measurements of the source positions to be obtained and is useful for rapid feedback in QA procedures.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Diagnóstico por Imagem , Feminino , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador