Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36916199

RESUMO

AIMS: The field of conduction system pacing (CSP) is evolving, and our aim was to obtain a contemporary picture of European CSP practice. METHODS AND RESULTS: A survey was devised by a European CSP Expert Group and sent electronically to cardiologists utilizing CSP. A total of 284 physicians were invited to contribute of which 171 physicians (60.2%; 85% electrophysiologists) responded. Most (77%) had experience with both His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP). Pacing indications ranked highest for CSP were atrioventricular block (irrespective of left ventricular ejection fraction) and when coronary sinus lead implantation failed. For patients with left bundle branch block (LBBB) and heart failure (HF), conventional biventricular pacing remained first-line treatment. For most indications, operators preferred LBBAP over HBP as a first-line approach. When HBP was attempted as an initial approach, reasons reported for transitioning to utilizing LBBAP were: (i) high threshold (reported as >2 V at 1 ms), (ii) failure to reverse bundle branch block, or (iii) > 30 min attempting to implant at His-bundle sites. Backup right ventricular lead use for HBP was low (median 20%) and predominated in pace-and-ablate scenarios. Twelve-lead electrocardiogram assessment was deemed highly important during follow-up. This, coupled with limitations from current capture management algorithms, limits remote monitoring for CSP patients. CONCLUSIONS: This survey provides a snapshot of CSP implementation in Europe. Currently, CSP is predominantly used for bradycardia indications. For HF patients with LBBB, most operators reserve CSP for biventricular implant failures. Left bundle branch area pacing ostensibly has practical advantages over HBP and is therefore preferred by many operators. Practical limitations remain, and large randomized clinical trial data are currently lacking.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Resultado do Tratamento , Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
2.
Artigo em Inglês | MEDLINE | ID: mdl-36652082

RESUMO

BACKGROUND: The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data. METHODS: Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less. RESULTS: Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months. CONCLUSIONS: The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04767516 .

3.
Europace ; 10(2): 161-3, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18208939

RESUMO

Pacemaker manufacturers have developed new algorithms to preserve intrinsic conduction in order to reduce unnecessary stimulation and looking for physiological pacing. This case report highlights some of the new challenges related to these algorithms which include possible ECG misinterpretations and inaccurate programming leading to potential negative consequences.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial/efeitos adversos , Idoso , Algoritmos , Bloqueio Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Falha de Equipamento , Reações Falso-Positivas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos
4.
Eur J Heart Fail ; 20(10): 1457-1468, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29806208

RESUMO

BACKGROUND: To date, there are no data from randomized controlled studies on the benefit of cardiac resynchronization therapy (CRT) when implanted as an upgrade in patients with a previous device as compared to de novo CRT. In the CRT Survey II we compared the baseline data of patients upgraded to CRT (CRT-P/CRT-D) from a previous pacemaker (PM) or implantable cardioverter-defibrillator (ICD) to de novo CRT implantation. METHODS AND RESULTS: In the European CRT Survey II, clinical practice data of patients undergoing CRT and/or ICD implantation across 42 European Society of Cardiology (ESC) countries were collected between October 2015 and December 2016. Out of a total of 11 088 patients, 2396 (23.2%) were upgraded from a previous PM or ICD and 7933 (76.8%) underwent de novo implantation. Compared to de novo implantations, upgraded patients were older, more often male, more frequently had ischaemic heart failure aetiology, atrial fibrillation, reduced renal function, worse heart failure symptoms, and higher N-terminal pro-B-type natriuretic peptide levels. Upgraded patients were more often PM-dependent and less frequently received CRT-D. Total peri-procedural, in-hospital complications and length of hospital stay were similar. Upgraded patients were less frequently treated with heart failure medication at discharge. CONCLUSION: Despite a lack of evidenced-based data, close to one quarter of all CRT implantations across 42 ESC countries were upgrades from a previous PM or ICD. Despite older age and worse symptoms, the CRT implantation procedures in upgraded patients were equally frequently successful and complications similar to de novo implantations. These results call for more studies.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Cardiologia , Insuficiência Cardíaca/terapia , Sociedades Médicas , Inquéritos e Questionários , Idoso , Europa (Continente)/epidemiologia , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento