RESUMO
Blood metal ion levels in 72 patients with large head metal-on-metal hip arthroplasty were studied to determine the correlation between the values measured in whole blood and urine. Urinary cobalt and chromium levels of 30µg and 21µg, respectively, adjusted to creatinine were found to correspond to the 7µg/l cut-off value that has been accepted in whole blood. Cobalt and chromium levels in whole blood and urine both significantly correlated with increased acetabular component inclination angle over 50 degrees and pain scores. There was no correlation with socket anteversion angle or femoral head diameter. The data support the use of urinary measurement of metal ions adjusted to creatinine to monitor patients with large head metal-on-metal total hip arthroplasty.
Assuntos
Artroplastia de Quadril/efeitos adversos , Cromo/sangue , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Acetábulo/patologia , Acetábulo/cirurgia , Adulto , Idoso , Líquidos Corporais/metabolismo , Cromo/urina , Cobalto/urina , Creatinina/sangue , Creatinina/urina , Feminino , Cabeça do Fêmur/patologia , Cabeça do Fêmur/cirurgia , Humanos , Íons/sangue , Íons/urina , Masculino , Pessoa de Meia-Idade , Alta do Paciente , Valor Preditivo dos Testes , Desenho de PróteseRESUMO
Alternative bearing surfaces for total hip arthroplasty, such as metal-on-metal and ceramic-on-ceramic, offer the potential to reduce mechanical wear and osteolysis. In the short and medium term, the second generation of metal-on-metal bearings demonstrated high systemic metal ion levels, whereas ceramic-on-ceramic bearings showed the lowest ones. We aimed to verify whether the long-term ion release in metal-on-metal subjects was still relevant at a median 10-year follow-up, and whether a fretting process at the modular junctions occurred in ceramic-on-ceramic patients and induced an ion dissemination. Serum levels were measured in 32 patients with alumina-on-alumina implants (group A), in 16 subjects with metal-on-metal implants (group B), and in 47 healthy subjects (group C). Group B results were compared with medium-term findings. Cobalt and chromium levels were significantly higher in metal-on-metal implants than in ceramic-on-ceramic ones and controls. Nevertheless, ion levels showed a tendency to decrease in comparison with medium-term content. In ceramic-on-ceramic implants, ion values were not significantly different from controls. Both in groups A and B, aluminum and titanium release were not significantly different from controls. In conclusion, negligible serum metal ion content was revealed in ceramic-on-ceramic patients. On the contrary, due to the higher ion release, metal-on-metal coupling must be prudently considered, especially in young patients, in order to obtain definitive conclusions.