Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
World J Urol ; 40(7): 1873-1878, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35445335

RESUMO

PURPOSE: To investigate the effect of prolonged laser activation on irrigation fluid temperature by varying the power settings flow rate (10-30 ml/min). MATERIALS AND METHODS: An experimental study using a 20 ml syringe, 12/14 ureteral access sheath, a dual-lumen catheter and a thermocouple was performed. The laser was fired with 12 W (0.3 J × 40 Hz), 40 W (1 J × 40 Hz), 60 W (1.5 J × 40 Hz) using Quanta Ho 150 W (Quanta System, Samarate, Italy). All trials were performed with fluid outflow rate of 10, 20 and 30 ml/min with the fixed fluid volume at 10 ml. RESULTS: Continuous laser activation for 10 min with the outflow rate of 10 ml/min using only 12 W resulted to continuous temperature rise to as high as 83 °C. Similar rise of temperatures were observed for 40 W and 60 W with 10 ml/min outflow rate with intermittent laser activation. With 20 and 30 ml/min outflow rates the maximum temperatures for all power settings were below the threshold (< 43 °C). However, the time to reach the same total emitted energy was 60% and 40% shorter 60 W and 40 W, respectively. CONCLUSION: Our study found that continuous laser activation with as less as 12 W using 10 ml/min outflow rate increased the irrigation fluid temperature above the threshold only after 1 min. In the current experimental setup, with the fluid outflow rate of 20 and 30 ml/min safe laser activation with 60 W and 40 W (temperature < 43 °C) can be achieved reaching the same total emitted energy as with 12 W in significantly shorter time period.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Ureter , Temperatura Alta , Humanos , Litotripsia a Laser/métodos , Temperatura
2.
Urol Ann ; 15(2): 191-196, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304519

RESUMO

Purpose: The purpose of this study was to evaluate renal parenchymal trauma of two-step dilation compared to the conventional Amplatz gradual dilation during percutaneous nephrolithotomy on a porcine model. Materials and Methods: A nonpapillary percutaneous access tract was established under fluoroscopic guidance in both kidneys of four female pigs. On the right kidney of each pig, gradual dilation was performed using an Amplatz dilator set with a gradual dilation to 30 Fr, whereas on the left, a two-step dilation was utilized using only 16 Fr and 30 Fr dilators. Two of the animals were euthanized immediately after the procedure and the remaining two 1 month later. The pigs that were kept alive underwent a contrast-enhanced computed tomography immediately, 15, and 30 days postoperatively. A dimercaptosuccinic acid (DMSA) scintigraphy and single-photon emission computed tomography-computed tomography (CT) were also performed after the last CT and afterward, the pigs were sacrificed. All kidneys were harvested for pathohistological examination. Results: The follow-up radiologic imaging showed similar parenchymal damage caused by the compared dilation techniques and an expected reduction in scar size in the later scans. No scar was identified by DMSA in any kidney. Gross and microscopic examinations conducted both on the kidneys that were harvested immediately after the procedure and the ones from the animals that were left to heal, revealed no significant differences in tissue damage, grade of fibrosis, or inflammation depending on the dilation method. Conclusions: Our study showed no inferior outcomes caused by two-step dilation compared to gradual dilation regarding renal parenchymal damage following a nonpapillary puncture. In fact, postoperative imaging findings suggested a trend toward better healing and less scar tissue when the two-step method was used.

3.
Urology ; 170: 53-59, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36115430

RESUMO

OBJECTIVE: To investigate the effect of the diameter of laser fiber, pelvis volume, presence and type of the stone on irrigation fluid temperature rise. MATERIAL AND METHODS: A 20ml syringe, 12/14 ureteral access sheath(UAS), a dual-lumen catheter and a thermocouple were used.  The 12/14Fr UAS(Cook Ireland Ltd., Limerick, Ireland) and the Thermocouple(SE001, Pico Technologies, Cambridgeshire, UK) were inserted in the syringe. The syringe was closed allowing outflow from the UAS with rate at 10ml/min. The Quanta Ho 150W(Quanta System, Samarate, Italy) laser was used and fired with 10W(2Jx5Hz), 20W(2 × 10 Hz), 40W(2 × 20 Hz), 60W(2 × 30 Hz). These power settings were tested in different conditions: fibers(200µm, 365µm and 550µm), volumes(5ml, 10ml and 20ml) and artificial stones(soft, hard). The laser was activated for 30 seconds and reactivation was performed when the temperature reached below 26 °C. RESULTS: For all trials 60W of energy resulted in higher temperature rise. No differences were observed when different fibers were used. The highest temperatures (up to 80 °C) for 60W were reported in 5ml syringe and the lowest (<45 °C) with 20ml.  The maximal temperature of >59°C was recorded for the power of 60W(1Jx60Hz). The temperature exceeded 43 °C when power settings >40W were applied. CONCLUSION: Increasing the overall power, increases the irrigation fluid temperature significantly. The smaller the volume of the pelvis, the greater the temperature elevation. The fiber size did not affect the temperature increase pattern. The presence of artificial stones was associated with the absorption of energy emitted by the laser.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Ureter , Humanos , Litotripsia a Laser/métodos , Temperatura , Lasers de Estado Sólido/uso terapêutico , Temperatura Alta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA